CINXE.COM
Search results for: oxygen saturation
<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: oxygen saturation</title> <meta name="description" content="Search results for: oxygen saturation"> <meta name="keywords" content="oxygen saturation"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="oxygen saturation" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="oxygen saturation"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 1837</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: oxygen saturation</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1837</span> Blood Oxygen Saturation Measurement System Using Broad-Band Light Source with LabVIEW Program</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Myoung%20Ah%20Kim">Myoung Ah Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Dong%20Ho%20Sin"> Dong Ho Sin</a>, <a href="https://publications.waset.org/abstracts/search?q=Chul%20Gyu%20Song"> Chul Gyu Song</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Blood oxygen saturation system is a well-established, noninvasive photoplethysmographic method to monitor vital signs. Conventional blood oxygen saturation measurements for the two LED light source is the ambiguity of the oxygen saturation measurement principle and the measurement results greatly influenced and heat and motion artifact. A high accuracy in order to solve these problems blood oxygen saturation measuring method has been proposed using a broadband light source that can be easily understood by the algorithm. The measurement of blood oxygen saturation based on broad-band light source has advantage of simple testing facility and easy understanding. Broadband light source based on blood oxygen saturation measuring program proposed in this paper is a combination of LabVIEW and MATLAB. Using the wavelength range of 450 nm-750 nm using a floating light absorption of oxyhemoglobin and deoxyhemoglobin to measure the blood oxygen saturation. Hand movement is to fix the probe to the motor stage in order to prevent oxygen saturation measurement that affect the sample and probe kept constant interval. Experimental results show that the proposed method noticeably increases the accuracy and saves time compared with the conventional methods. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation" title="oxygen saturation">oxygen saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=broad-band%20light%20source" title=" broad-band light source"> broad-band light source</a>, <a href="https://publications.waset.org/abstracts/search?q=CCD" title=" CCD"> CCD</a>, <a href="https://publications.waset.org/abstracts/search?q=light%20reflectance%20theory" title=" light reflectance theory"> light reflectance theory</a> </p> <a href="https://publications.waset.org/abstracts/40627/blood-oxygen-saturation-measurement-system-using-broad-band-light-source-with-labview-program" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/40627.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">459</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1836</span> Development of Soft-Core System for Heart Rate and Oxygen Saturation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Caje%20F.%20Pinto">Caje F. Pinto</a>, <a href="https://publications.waset.org/abstracts/search?q=Jivan%20S.%20Parab"> Jivan S. Parab</a>, <a href="https://publications.waset.org/abstracts/search?q=Gourish%20M.%20Naik"> Gourish M. Naik</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper is about the development of non-invasive heart rate and oxygen saturation in human blood using Altera NIOS II soft-core processor system. In today's world, monitoring oxygen saturation and heart rate is very important in hospitals to keep track of low oxygen levels in blood. We have designed an Embedded System On Peripheral Chip (SOPC) reconfigurable system by interfacing two LED’s of different wavelengths (660 nm/940 nm) with a single photo-detector to measure the absorptions of hemoglobin species at different wavelengths. The implementation of the interface with Finger Probe and Liquid Crystal Display (LCD) was carried out using NIOS II soft-core system running on Altera NANO DE0 board having target as Cyclone IVE. This designed system is used to monitor oxygen saturation in blood and heart rate for different test subjects. The designed NIOS II processor based non-invasive heart rate and oxygen saturation was verified with another Operon Pulse oximeter for 50 measurements on 10 different subjects. It was found that the readings taken were very close to the Operon Pulse oximeter. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=heart%20rate" title="heart rate">heart rate</a>, <a href="https://publications.waset.org/abstracts/search?q=NIOS%20II" title=" NIOS II"> NIOS II</a>, <a href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation" title=" oxygen saturation"> oxygen saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=photoplethysmography" title=" photoplethysmography"> photoplethysmography</a>, <a href="https://publications.waset.org/abstracts/search?q=soft-core" title=" soft-core"> soft-core</a>, <a href="https://publications.waset.org/abstracts/search?q=SOPC" title=" SOPC"> SOPC</a> </p> <a href="https://publications.waset.org/abstracts/82788/development-of-soft-core-system-for-heart-rate-and-oxygen-saturation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/82788.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">195</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1835</span> Oxygen Transport in Blood Flows Pasts Staggered Fiber Arrays: A Computational Fluid Dynamics Study of an Oxygenator in Artificial Lung</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Yu-Chen%20Hsu">Yu-Chen Hsu</a>, <a href="https://publications.waset.org/abstracts/search?q=Kuang%20C.%20Lin"> Kuang C. Lin</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The artificial lung called extracorporeal membrane oxygenation (ECMO) is an important medical machine that supports persons whose heart and lungs dysfunction. Previously, investigation of steady deoxygenated blood flows passing through hollow fibers for oxygen transport was carried out experimentally and computationally. The present study computationally analyzes the effect of biological pulsatile flow on the oxygen transport in blood. A 2-D model with a pulsatile flow condition is employed. The power law model is used to describe the non-Newtonian flow and the Hill equation is utilized to simulate the oxygen saturation of hemoglobin. The dimensionless parameters for the physical model include Reynolds numbers (Re), Womersley parameters (α), pulsation amplitudes (A), Sherwood number (Sh) and Schmidt number (Sc). The present model with steady-state flow conditions is well validated against previous experiment and simulations. It is observed that pulsating flow amplitudes significantly influence the velocity profile, pressure of oxygen (PO2), saturation of oxygen (SO2) and the oxygen mass transfer rates (m ̇_O2). In comparison between steady-state and pulsating flows, our findings suggest that the consideration of pulsating flow in the computational model is needed when Re is raised from 2 to 10 in a typical range for flow in artificial lung. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=artificial%20lung" title="artificial lung">artificial lung</a>, <a href="https://publications.waset.org/abstracts/search?q=oxygen%20transport" title=" oxygen transport"> oxygen transport</a>, <a href="https://publications.waset.org/abstracts/search?q=non-Newtonian%20flows" title=" non-Newtonian flows"> non-Newtonian flows</a>, <a href="https://publications.waset.org/abstracts/search?q=pulsating%20flows" title=" pulsating flows"> pulsating flows</a> </p> <a href="https://publications.waset.org/abstracts/46560/oxygen-transport-in-blood-flows-pasts-staggered-fiber-arrays-a-computational-fluid-dynamics-study-of-an-oxygenator-in-artificial-lung" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/46560.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">311</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1834</span> Acute Effect of Street Dance Exercise on Blood Pressure, Heart Rate, Oxygen Saturation and Physical Fitness in Sedentary Subjects: A Pilot Study</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Taweesak%20%20Janyacharoen">Taweesak Janyacharoen</a>, <a href="https://publications.waset.org/abstracts/search?q=Lalita%20Pradubgool"> Lalita Pradubgool</a>, <a href="https://publications.waset.org/abstracts/search?q=Lalita%20Wongsorn"> Lalita Wongsorn</a>, <a href="https://publications.waset.org/abstracts/search?q=Pitchayapa%20%20Janyacharoen"> Pitchayapa Janyacharoen</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Street dance is a form of exercise that is classified as aerobic and is very suitable for teenagers. Street dance is a dance that can create new dance moves all the time. It often incorporates elements from gymnastics and is accompanied by fast-paced music that emphasizes excitement and energy. It is a combination of high-intensity and low-intensity activities. Few studies have looked at the effects of street dance on cardiovascular endurance, and previous studies have long-term effects. However, no research study in Thailand has studied acute effects before. This study was to investigate the acute effect of street dance exercise on blood pressure, heart rate, oxygen saturation and physical fitness in sedentary subjects. Subjects were divided into 2 groups: the control group (n=15) received health education and rest, and the experimental group (n=15) received street dance exercise. Both groups will measure their blood pressure (BP), mean arterial pressure (MAP), heart rate (HR), oxygen saturation (SpO₂) and six-minute walk test (6MWT) before and after completing the program. The results found that both groups had significantly different HR when comparing before and after the program (p<0.05). MAP, HR and SpO₂ had significantly different (p<0.05) when compared between groups. This study concluded that the acute effect of street dance exercise could be increased in HR while the SpO₂ decreased. In clinical, it was seen that the values that were changed are still within the range that is considered normal. Therefore, street dance exercises can be used as one choice of alternative exercise. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=street%20dance" title="street dance">street dance</a>, <a href="https://publications.waset.org/abstracts/search?q=exercise" title=" exercise"> exercise</a>, <a href="https://publications.waset.org/abstracts/search?q=blood%20pressure" title=" blood pressure"> blood pressure</a>, <a href="https://publications.waset.org/abstracts/search?q=heart%20rate" title=" heart rate"> heart rate</a>, <a href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation" title=" oxygen saturation"> oxygen saturation</a> </p> <a href="https://publications.waset.org/abstracts/187076/acute-effect-of-street-dance-exercise-on-blood-pressure-heart-rate-oxygen-saturation-and-physical-fitness-in-sedentary-subjects-a-pilot-study" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/187076.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">39</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1833</span> O2 Saturation Comparison Between Breast Milk Feeding and Tube Feeding in Very Low Birth Weight Neonates</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ashraf%20Mohammadzadeh">Ashraf Mohammadzadeh</a>, <a href="https://publications.waset.org/abstracts/search?q=Ahmad%20Shah%20Farhat"> Ahmad Shah Farhat</a>, <a href="https://publications.waset.org/abstracts/search?q=Azin%20Vaezi"> Azin Vaezi</a>, <a href="https://publications.waset.org/abstracts/search?q=Aradokht%20Vaezi"> Aradokht Vaezi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background & Aim: Preterm infants born at less than 34 weeks postconceptional age are not as neurologically mature as their term counterparts and thus have difficulty coordinating sucking, swallowing and breathing. As a result, they are traditionally gavage fed until they are able to oral feed successfully. The aim of study was to evaluate comparative effect of orogastric and breast feeding on oxygen saturation in very low birth weight infant (<1500gm). Patients and Methods: In this clinical trial all babies admitted in the Neonatal Research Center of Imamreza Hospital, Mashhad during a 4 months period were elected. Criteria for entrance to study included birth weight ≤ 1500 grams, exclusive breastfeeding, having no special problem after 48 hours, receivinge only routine care and intake of milk was 100cc/kg/day. Each neonate received two rounds of orogastric and breast feeding in the morning and in the afternoon, during which mean oxygen saturation was measured by pulse-oxymetry. During the study the heart rate and temperature of the neonates were monitored, and in case of hypothermia, bradycardia(less than 100 per minute) or apnea the feeding was discontinued and the study was repeated the following day. Data analysis was carried out using SPSS. Results: Fifty neonates were studied. The average birth weight was 1267.20±165.42 grams and average gestational age was 31.81±1.92 and female/male ratio was 1.2. There was no significant statistical difference in arterial oxygen saturation in orogastric and breast feeding in the morning and in the afternoon. (p=0.16 in the morning and p=0.6 in the afternoon). There was no complication of apnea, hypothermia or bradycardia. Conclusion: There was no significant statistical difference between the two methods in arterial oxygen saturation. It seems that oral feeding (which is a natural route) and skin contact between the mother and neonate causes a strong emotional bonding between the two and brings about better social adaptation for the neonate. Also shorter period of stay in hospital is more preferred, and breast feeding should be started at the earliest possible time after birth. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Very%20low%20birth%20weight%20%28V.L.B.W%29" title="Very low birth weight (V.L.B.W)">Very low birth weight (V.L.B.W)</a>, <a href="https://publications.waset.org/abstracts/search?q=O2%20Saturation" title=" O2 Saturation"> O2 Saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=Breast%20Feeding" title=" Breast Feeding"> Breast Feeding</a>, <a href="https://publications.waset.org/abstracts/search?q=Tube%20Feeding" title=" Tube Feeding"> Tube Feeding</a> </p> <a href="https://publications.waset.org/abstracts/162000/o2-saturation-comparison-between-breast-milk-feeding-and-tube-feeding-in-very-low-birth-weight-neonates" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/162000.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">86</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1832</span> Muscle and Cerebral Regional Oxygenation in Preterm Infants with Shock Using Near-Infrared Spectroscopy</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Virany%20Diana">Virany Diana</a>, <a href="https://publications.waset.org/abstracts/search?q=Martono%20Tri%20Utomo"> Martono Tri Utomo</a>, <a href="https://publications.waset.org/abstracts/search?q=Risa%20Etika"> Risa Etika</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Shock is one severe condition that can be a major cause of morbidity and mortality in the Neonatal Intensive Care Unit. Preterm infants are very susceptible to shock caused by many complications such as asphyxia, patent ductus arteriosus, intra ventricle haemorrhage, necrotizing enterocolitis, persistent pulmonal hypertension of the newborn, and septicaemia. Limited hemodynamic monitoring for early detection of shock causes delayed intervention and comprises the outcomes. Clinical parameters still used in neonatal shock detection, such as Capillary Refill Time, heart rate, cold extremity, and urine production. Blood pressure is most frequently used to evaluate preterm's circulation, but hypotension indicates uncompensated shock. Near-infrared spectroscopy (NIRS) is known as a noninvasive tool for monitoring and detecting the state of inadequate tissue perfusion. Muscle oxygen saturation shows decreased cardiac output earlier than systemic parameters of tissue oxygenation when cerebral regional oxygen saturation is still stabilized by autoregulation. However, to our best knowledge, until now, no study has analyzed the decrease of muscle oxygen regional saturation (mRSO₂) and the ratio of muscle and cerebral oxygen regional saturation (mRSO₂/cRSO₂) by NIRS in preterm with shock. Purpose: The purpose of this study is to analyze the decrease of mRSO₂ and ratio of muscle to cerebral oxygen regional saturation (mRSO₂/cRSO₂) by NIRS in preterm with shock. Patients and Methods: This cross-sectional study was conducted on preterm infants with 28-34 weeks gestational age, admitted to the NICU of Dr. Soetomo Hospital from November to January 2022. Patients were classified into two groups: shock and non-shock. The diagnosis of shock is based on clinical criteria (tachycardia, prolonged CRT, cold extremity, decreased urine production, and MAP Blood Pressure less than GA in weeks). Measurement of mRSO₂ and cRSO₂ by NIRS was performed by the doctor in charge when the patient came to NICU. Results: We enrolled 40 preterm infants. The initial conventional hemodynamic parameter as the basic diagnosis of shock showed significant differences in all variables. Preterm with shock had higher mean HR (186.45±1.5), lower MAP (29.8±2.1), and lower SBP (45.1±4.28) than non-shock children, and most had a prolonged CRT. The patients’ outcome was not a significant difference between shock and non-shock patients. The mean mRSO₂ in the shock and non-shock groups were 33,65 ± 11,32 vs. 69,15 ± 3,96 (p=0.001), and the mean ratio mRSO₂/cRSO₂ 0,45 ± 0,12 vs. 0,84 ± 0,43 (p=0,001), were significantly different. The mean cRSO₂ in the shock and non-shock groups were 71,60 ± 4,90 vs. 81,85 ± 7,85 (p 0.082), not significantly different. Conclusion: The decrease of mRSO₂ and ratio of mRSO₂/cRSO₂ can differentiate between shock and non-shock in the preterm infant when cRSO₂ is still normal. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=preterm%20infant" title="preterm infant">preterm infant</a>, <a href="https://publications.waset.org/abstracts/search?q=regional%20muscle%20oxygen%20saturation" title=" regional muscle oxygen saturation"> regional muscle oxygen saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=regional%20cerebral%20oxygen%20saturation" title=" regional cerebral oxygen saturation"> regional cerebral oxygen saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=NIRS" title=" NIRS"> NIRS</a>, <a href="https://publications.waset.org/abstracts/search?q=shock" title=" shock"> shock</a> </p> <a href="https://publications.waset.org/abstracts/162277/muscle-and-cerebral-regional-oxygenation-in-preterm-infants-with-shock-using-near-infrared-spectroscopy" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/162277.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">91</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1831</span> Assessment of Petrophysical Parameters Using Well Log and Core Data</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Khulud%20M.%20Rahuma">Khulud M. Rahuma</a>, <a href="https://publications.waset.org/abstracts/search?q=Ibrahim%20B.%20Younis"> Ibrahim B. Younis</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Assessment of petrophysical parameters are very essential for reservoir engineer. Three techniques can be used to predict reservoir properties: well logging, well testing, and core analysis. Cementation factor and saturation exponent are very required for calculation, and their values role a great effect on water saturation estimation. In this study a sensitive analysis was performed to investigate the influence of cementation factor and saturation exponent variation applying logs, and core analysis. Measurements of water saturation resulted in a maximum difference around fifteen percent. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=porosity" title="porosity">porosity</a>, <a href="https://publications.waset.org/abstracts/search?q=cementation%20factor" title=" cementation factor"> cementation factor</a>, <a href="https://publications.waset.org/abstracts/search?q=saturation%20exponent" title=" saturation exponent"> saturation exponent</a>, <a href="https://publications.waset.org/abstracts/search?q=formation%20factor" title=" formation factor"> formation factor</a>, <a href="https://publications.waset.org/abstracts/search?q=water%20saturation" title=" water saturation"> water saturation</a> </p> <a href="https://publications.waset.org/abstracts/11077/assessment-of-petrophysical-parameters-using-well-log-and-core-data" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/11077.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">693</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1830</span> Research on the Aeration Systems’ Efficiency of a Lab-Scale Wastewater Treatment Plant</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Oliver%20Marun%C8%9B%C4%83lu">Oliver Marunțălu</a>, <a href="https://publications.waset.org/abstracts/search?q=Elena%20Elisabeta%20Manea"> Elena Elisabeta Manea</a>, <a href="https://publications.waset.org/abstracts/search?q=L%C4%83cr%C4%83mioara%20Diana%20Robescu"> Lăcrămioara Diana Robescu</a>, <a href="https://publications.waset.org/abstracts/search?q=Mihai%20Nec%C8%99oiu"> Mihai Necșoiu</a>, <a href="https://publications.waset.org/abstracts/search?q=Gheorghe%20L%C4%83z%C4%83roiu"> Gheorghe Lăzăroiu</a>, <a href="https://publications.waset.org/abstracts/search?q=Dana%20Andreya%20Bondrea"> Dana Andreya Bondrea</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In order to obtain efficient pollutants removal in small-scale wastewater treatment plants, uniform water flow has to be achieved. The experimental setup, designed for treating high-load wastewater (leachate), consists of two aerobic biological reactors and a lamellar settler. Both biological tanks were aerated by using three different types of aeration systems - perforated pipes, membrane air diffusers and tube ceramic diffusers. The possibility of homogenizing the water mass with each of the air diffusion systems was evaluated comparatively. The oxygen concentration was determined by optical sensors with data logging. The experimental data was analyzed comparatively for all three different air dispersion systems aiming to identify the oxygen concentration variation during different operational conditions. The Oxygenation Capacity was calculated for each of the three systems and used as performance and selection parameter. The global mass transfer coefficients were also evaluated as important tools in designing the aeration system. Even though using the tubular porous diffusers leads to higher oxygen concentration compared to the perforated pipe system (which provides medium-sized bubbles in the aqueous solution), it doesn’t achieve the threshold limit of 80% oxygen saturation in less than 30 minutes. The study has shown that the optimal solution for the studied configuration was the radial air diffusers which ensure an oxygen saturation of 80% in 20 minutes. An increment of the values was identified when the air flow was increased. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=flow" title="flow">flow</a>, <a href="https://publications.waset.org/abstracts/search?q=aeration" title=" aeration"> aeration</a>, <a href="https://publications.waset.org/abstracts/search?q=bioreactor" title=" bioreactor"> bioreactor</a>, <a href="https://publications.waset.org/abstracts/search?q=oxygen%20concentration" title=" oxygen concentration "> oxygen concentration </a> </p> <a href="https://publications.waset.org/abstracts/29016/research-on-the-aeration-systems-efficiency-of-a-lab-scale-wastewater-treatment-plant" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/29016.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">389</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1829</span> Remote Patient Monitoring for Covid-19</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Launcelot%20McGrath">Launcelot McGrath</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The Coronavirus disease 2019 (COVID-19) has spread rapidly around the world, resulting in high mortality rates and very large numbers of people requiring medical treatment in ICU. Management of patient hospitalisation is a critical aspect to control this disease and reduce chaos in the healthcare systems. Remote monitoring provides a solution to protect vulnerable and elderly high-risk patients. Continuous remote monitoring of oxygen saturation, respiratory rate, heart rate, and temperature, etc., provides medical systems with up-to-the-minute information about their patients' statuses. Remote monitoring also limits the spread of infection by reducing hospital overcrowding. This paper examines the potential of remote monitoring for Covid-19 to assist in the rapid identification of patients at risk, facilitate the detection of patient deterioration, and enable early interventions. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=remote%20monitoring" title="remote monitoring">remote monitoring</a>, <a href="https://publications.waset.org/abstracts/search?q=patient%20care" title=" patient care"> patient care</a>, <a href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation" title=" oxygen saturation"> oxygen saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=Covid-19" title=" Covid-19"> Covid-19</a>, <a href="https://publications.waset.org/abstracts/search?q=hospital%20management" title=" hospital management"> hospital management</a> </p> <a href="https://publications.waset.org/abstracts/158709/remote-patient-monitoring-for-covid-19" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/158709.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">108</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1828</span> Field Saturation Flow Measurement Using Dynamic Passenger Car Unit under Mixed Traffic Condition</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ramesh%20Chandra%20Majhi">Ramesh Chandra Majhi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Saturation flow is a very important input variable for the design of signalized intersections. Saturation flow measurement is well established for homogeneous traffic. However, saturation flow measurement and modeling is a challenging task in heterogeneous characterized by multiple vehicle types and non-lane based movement. Present study focuses on proposing a field procedure for Saturation flow measurement and the effect of typical mixed traffic behavior at the signal as far as non-lane based traffic movement is concerned. Data collected during peak and off-peak hour from five intersections with varying approach width is used for validating the saturation flow model. The insights from the study can be used for modeling saturation flow and delay at signalized intersection in heterogeneous traffic conditions. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=optimization" title="optimization">optimization</a>, <a href="https://publications.waset.org/abstracts/search?q=passenger%20car%20unit" title=" passenger car unit"> passenger car unit</a>, <a href="https://publications.waset.org/abstracts/search?q=saturation%20flow" title=" saturation flow"> saturation flow</a>, <a href="https://publications.waset.org/abstracts/search?q=signalized%20intersection" title=" signalized intersection"> signalized intersection</a> </p> <a href="https://publications.waset.org/abstracts/63968/field-saturation-flow-measurement-using-dynamic-passenger-car-unit-under-mixed-traffic-condition" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/63968.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">327</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1827</span> Introduction of Integrated Image Deep Learning Solution and How It Brought Laboratorial Level Heart Rate and Blood Oxygen Results to Everyone</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Zhuang%20Hou">Zhuang Hou</a>, <a href="https://publications.waset.org/abstracts/search?q=Xiaolei%20Cao"> Xiaolei Cao</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The general public and medical professionals recognized the importance of accurately measuring and storing blood oxygen levels and heart rate during the COVID-19 pandemic. The demand for accurate contactless devices was motivated by the need for cross-infection reduction and the shortage of conventional oximeters, partially due to the global supply chain issue. This paper evaluated a contactless mini program HealthyPai’s heart rate (HR) and oxygen saturation (SpO2) measurements compared with other wearable devices. In the HR study of 185 samples (81 in the laboratory environment, 104 in the real-life environment), the mean absolute error (MAE) ± standard deviation was 1.4827 ± 1.7452 in the lab, 6.9231 ± 5.6426 in the real-life setting. In the SpO2 study of 24 samples, the MAE ± standard deviation of the measurement was 1.0375 ± 0.7745. Our results validated that HealthyPai utilizing the Integrated Image Deep Learning Solution (IIDLS) framework, can accurately measure HR and SpO2, providing the test quality at least comparable to other FDA-approved wearable devices in the market and surpassing the consumer-grade and research-grade wearable standards. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=remote%20photoplethysmography" title="remote photoplethysmography">remote photoplethysmography</a>, <a href="https://publications.waset.org/abstracts/search?q=heart%20rate" title=" heart rate"> heart rate</a>, <a href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation" title=" oxygen saturation"> oxygen saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=contactless%20measurement" title=" contactless measurement"> contactless measurement</a>, <a href="https://publications.waset.org/abstracts/search?q=mini%20program" title=" mini program"> mini program</a> </p> <a href="https://publications.waset.org/abstracts/149992/introduction-of-integrated-image-deep-learning-solution-and-how-it-brought-laboratorial-level-heart-rate-and-blood-oxygen-results-to-everyone" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/149992.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">135</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1826</span> Anesthetic Considerations for Carotid Endarterectomy: Prospective Study Based on Clinical Trials</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20Yousef%20A.%20Al%20Sultan">Ahmed Yousef A. Al Sultan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: The aim of this review is based on clinical research that studies the changes in middle cerebral artery velocity using Transcranial Doppler (TCD) and cerebral oxygen saturation using cerebral oximetry in patients undergoing carotid endarterectomy (CEA) surgery under local anesthesia (LA). Patients with or without neurological symptoms during the surgery are taking a role in this study using triplet method of cerebral oximetry, transcranial doppler and awake test in detecting any cerebral ischemic symptoms. Methods: about one hundred patients took part during their CEA surgeries under local anesthesia, using triple assessment mentioned method, Patients requiring general anesthesia be excluded from analysis. All data were recorded at eight surgery stages separately to serve this study. Results: In total regional cerebral oxygen saturation (rSO2), middle cerebral artery (MCA) velocity, and pulsatility index were significantly decreased during carotid artery clamping step in CEA procedures on the targeted carotid side. With most observed changes in MCA velocity during the study. Discussion: Cerebral oxygen saturation and middle cerebral artery velocity were significantly decreased during clamping step of the procedures on the targeted side. The team with neurological symptoms during the procedures showed higher changes of rSO2 and MCA velocity than the team without neurological symptoms. Cerebral rSO2 and MCA velocity significantly increased directly after de-clamping of the internal carotid artery on the affected side. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=awake%20testing" title="awake testing">awake testing</a>, <a href="https://publications.waset.org/abstracts/search?q=carotid%20endarterectomy" title=" carotid endarterectomy"> carotid endarterectomy</a>, <a href="https://publications.waset.org/abstracts/search?q=cerebral%20oximetry" title=" cerebral oximetry"> cerebral oximetry</a>, <a href="https://publications.waset.org/abstracts/search?q=Tanscranial%20Doppler" title=" Tanscranial Doppler"> Tanscranial Doppler</a> </p> <a href="https://publications.waset.org/abstracts/85460/anesthetic-considerations-for-carotid-endarterectomy-prospective-study-based-on-clinical-trials" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/85460.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">169</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1825</span> Saturation Misbehavior and Field Activation of the Mobility in Polymer-Based OTFTs</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=L.%20Giraudet">L. Giraudet</a>, <a href="https://publications.waset.org/abstracts/search?q=O.%20Simonetti"> O. Simonetti</a>, <a href="https://publications.waset.org/abstracts/search?q=G.%20de%20Tournadre"> G. de Tournadre</a>, <a href="https://publications.waset.org/abstracts/search?q=N.%20Dumeli%C3%A9"> N. Dumelié</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Clarenc"> B. Clarenc</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20Reisdorffer"> F. Reisdorffer</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper we intend to give a comprehensive view of the saturation misbehavior of thin film transistors (TFTs) based on disordered semiconductors, such as most organic TFTs, and its link to the field activation of the mobility. Experimental evidence of the field activation of the mobility is given for disordered semiconductor based TFTs, when reducing the gate length. Saturation misbehavior is observed simultaneously. Advanced transport models have been implemented in a quasi-2D numerical TFT simulation software. From the numerical simulations it is clearly established that field activation of the mobility alone cannot explain the saturation misbehavior. Evidence is given that high longitudinal field gradient at the drain end of the channel is responsible for an excess charge accumulation, preventing saturation. The two combined effects allow reproducing the experimental output characteristics of short channel TFTs, with S-shaped characteristics and saturation failure. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=mobility%20field%20activation" title="mobility field activation">mobility field activation</a>, <a href="https://publications.waset.org/abstracts/search?q=numerical%20simulation" title=" numerical simulation"> numerical simulation</a>, <a href="https://publications.waset.org/abstracts/search?q=OTFT" title=" OTFT"> OTFT</a>, <a href="https://publications.waset.org/abstracts/search?q=saturation%20failure" title=" saturation failure "> saturation failure </a> </p> <a href="https://publications.waset.org/abstracts/19411/saturation-misbehavior-and-field-activation-of-the-mobility-in-polymer-based-otfts" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/19411.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">520</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1824</span> Behavior of Clay effect on Electrical Parameter of Reservoir Rock Using Global Hydraulic Elements (GHEs) Approach </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Noreddin%20Mousa">Noreddin Mousa</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The main objective of this study is to estimate which type of clay minerals that more effect on saturation exponent using Global Hydraulic Elements (GHEs) approach to estimating the distribution of saturation exponent factor. Two wells and seven core samples have been selected from various (GHEs) for detailed study. There are many factors affecting saturation exponent such as wettability, grain pattern pressure of certain authigenic clays, which may promote oil wet characteristics of history of fluid displacement. The saturation exponent is related to the texture and affected by wettability and clay minerals. Capillary pressure (mercury injection) has been used to confirm GHEs which are selected to define rock types; the porous plate method is used to derive the saturation exponent in the laboratory. The petrography is very important in order to study the mineralogy and texture. In this study the results showing excellent relation between saturation exponent and the type of clay minerals which was observed that the Global Hydraulic Elements GHE-2 and GHE-5 which are containing Chlorite is more affect on saturation exponent comparing with the other GHE’s. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=GHEs" title="GHEs">GHEs</a>, <a href="https://publications.waset.org/abstracts/search?q=wettability" title=" wettability"> wettability</a>, <a href="https://publications.waset.org/abstracts/search?q=global%20hydraulic%20elements" title=" global hydraulic elements"> global hydraulic elements</a>, <a href="https://publications.waset.org/abstracts/search?q=petrography" title=" petrography "> petrography </a> </p> <a href="https://publications.waset.org/abstracts/3162/behavior-of-clay-effect-on-electrical-parameter-of-reservoir-rock-using-global-hydraulic-elements-ghes-approach" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/3162.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">301</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1823</span> Effect of Traffic Composition on Delay and Saturation Flow at Signal Controlled Intersections</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Arpita%20Saha">Arpita Saha</a>, <a href="https://publications.waset.org/abstracts/search?q=Apoorv%20Jain"> Apoorv Jain</a>, <a href="https://publications.waset.org/abstracts/search?q=Satish%20Chandra"> Satish Chandra</a>, <a href="https://publications.waset.org/abstracts/search?q=Indrajit%20Ghosh"> Indrajit Ghosh</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Level of service at a signal controlled intersection is directly measured from the delay. Similarly, saturation flow rate is a fundamental parameter to measure the intersection capacity. The present study calculates vehicle arrival rate, departure rate, and queue length for every five seconds interval in each cycle. Based on the queue lengths, the total delay of the cycle has been calculated using Simpson’s 1/3rd rule. Saturation flow has been estimated in terms of veh/hr of green/lane for every five seconds interval of the green period until at least three vehicles are left to cross the stop line. Vehicle composition shows an immense effect on total delay and saturation flow rate. The increase in two-wheeler proportion increases the saturation flow rate and reduces the total delay per vehicle significantly. Additionally, an increase in the heavy vehicle proportion reduces the saturation flow rate and increases the total delay for each vehicle. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=delay" title="delay">delay</a>, <a href="https://publications.waset.org/abstracts/search?q=saturation%20flow" title=" saturation flow"> saturation flow</a>, <a href="https://publications.waset.org/abstracts/search?q=signalised%20intersection" title=" signalised intersection"> signalised intersection</a>, <a href="https://publications.waset.org/abstracts/search?q=vehicle%20composition" title=" vehicle composition"> vehicle composition</a> </p> <a href="https://publications.waset.org/abstracts/62341/effect-of-traffic-composition-on-delay-and-saturation-flow-at-signal-controlled-intersections" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/62341.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">464</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1822</span> Effect of Compaction and Degree of Saturation on the Unconsolidated Undrained Shear Strength of Sandy Clay</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Fatima%20Mehmood">Fatima Mehmood</a>, <a href="https://publications.waset.org/abstracts/search?q=Khalid%20Farooq"> Khalid Farooq</a>, <a href="https://publications.waset.org/abstracts/search?q=Rabeea%20Bakhtawer"> Rabeea Bakhtawer</a> </p> <p class="card-text"><strong>Abstract:</strong></p> For geotechnical engineers, one of the most important properties of soil to consider in various stability analyses is its shear strength which is governed by a number of factors. The objective of this research is to ascertain the effect of compaction and degree of saturation on the shear strength of fine-grained soil. For this purpose, three different dry densities such as in-situ, maximum standard proctor, and maximum modified proctor, were determined for the sandy clay soil. The soil samples were then prepared to keep dry density constant and varying degrees of saturation. These samples were tested for (UU) unconsolidated undrained shear strength in triaxial compression tests. The decrease in shear strength was observed with the decrease in density and increase in the saturation. The values of the angle of internal friction followed the same trend. However, the change in cohesion with the increase in saturation showed a different behavior, analogous to the compaction curve. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=compaction" title="compaction">compaction</a>, <a href="https://publications.waset.org/abstracts/search?q=degree%20of%20saturation" title=" degree of saturation"> degree of saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=dry%20density" title=" dry density"> dry density</a>, <a href="https://publications.waset.org/abstracts/search?q=geotechnical%20investigation" title=" geotechnical investigation"> geotechnical investigation</a>, <a href="https://publications.waset.org/abstracts/search?q=laboratory%20testing" title=" laboratory testing"> laboratory testing</a>, <a href="https://publications.waset.org/abstracts/search?q=shear%20strength" title=" shear strength"> shear strength</a> </p> <a href="https://publications.waset.org/abstracts/112365/effect-of-compaction-and-degree-of-saturation-on-the-unconsolidated-undrained-shear-strength-of-sandy-clay" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/112365.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">137</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1821</span> Different Response of Pure Arctic Char Salvelinus alpinus and Hybrid (Salvelinus alpinus vs. Salvelinus fontinalis Mitchill) to Various Hyperoxic Regimes</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=V.%20Stejskal">V. Stejskal</a>, <a href="https://publications.waset.org/abstracts/search?q=K.%20Lundova"> K. Lundova</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20Sebesta"> R. Sebesta</a>, <a href="https://publications.waset.org/abstracts/search?q=T.%20Vanina"> T. Vanina</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20Roje"> S. Roje</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Pure strain of Arctic char (AC) Salvelinus alpinus and hybrid (HB) Salvelinus alpinus vs. Salvelinus fontinalis Mitchill belong to fish, which with great potential for culture in recirculating aquaculture systems (RAS). Aquaculture of these fish currently use flow-through systems (FTS), especially in Nordic countries such as Iceland (biggest producer), Norway, Sweden, and Canada. Four different water saturation regimes included normoxia (NOR), permanent hyperoxia (HYP), intermittent hyperoxia (HYP ± ) and regimes where one day of normoxia was followed by one day of hyperoxia (HYP1/1) were tested during 63 days of experiment in both species in two parallel experiments. Fish were reared in two identical RAS system consisted of 24 plastic round tanks (300 L each), drum filter, biological filter with moving beads and submerged biofilter. The temperature was maintained using flow-through cooler during at level of 13.6 ± 0.8 °C. Different water saturation regimes were achieved by mixing of pure oxygen (O₂) with water in three (one for each hyperoxic regime) mixing tower equipped with flowmeter for regulation of gas inflow. The water in groups HYP, HYP1/1 and HYP± was enriched with oxygen up to saturation of 120-130%. In HYP group was this level kept during whole day. In HYP ± group was hyperoxia kept for daylight phase (08:00-20:00) only and during night time was applied normoxia in this group. The oxygen saturation of 80-90% in NOR group was created using intensive aeration in header tank. The fish were fed with commercial feed to slight excess at 2 h intervals within the light phase of the day. Water quality parameters like pH, temperature and level of oxygen was monitoring three times (7 am, 10 am and 6 pm) per day using handy multimeter. Ammonium, nitrite and nitrate were measured in two day interval using spectrophotometry. Initial body weight (BW) was 40.9 ± 8.7 g and 70.6 ± 14.8 in AC and HB group, respectively. Final survival of AC ranged from 96.3 ± 4.6 (HYP) to 100 ± 0.0% in all other groups without significant differences among these groups. Similarly very high survival was reached in trial with HB with levels from 99.2 ± 1.3 (HYP, HYP1/1 and NOR) to 100 ± 0.0% (HYP ± ). HB fish showed best growth performance in NOR group reached final body weight (BW) 180.4 ± 2.3 g. Fish growth under different hyperoxic regimes was significantly reduced and final BW was 164.4 ± 7.6, 162.1 ± 12.2 and 151.7 ± 6.8 g in groups HY1/1, HYP ± and HYP, respectively. AC showed different preference for hyperoxic regimes as there were no significant difference in BW among NOR, HY1/1 and HYP± group with final values of 72.3 ± 11.3, 68.3 ± 8.4 and 77.1 ± 6.1g. Significantly reduced growth (BW 61.8 ± 6.8 g) was observed in HYP group. It is evident from present study that there are differences between pure bred Arctic char and hybrid in relation to hyperoxic regimes. The study was supported by projects 'CENAKVA' (No. CZ.1.05/2.1.00/01.0024), 'CENAKVA II' (No. LO1205 under the NPU I program), NAZV (QJ1510077) and GAJU (No. 060/2016/Z). <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=recirculating%20aquaculture%20systems" title="recirculating aquaculture systems">recirculating aquaculture systems</a>, <a href="https://publications.waset.org/abstracts/search?q=Salmonidae" title=" Salmonidae"> Salmonidae</a>, <a href="https://publications.waset.org/abstracts/search?q=hyperoxia" title=" hyperoxia"> hyperoxia</a>, <a href="https://publications.waset.org/abstracts/search?q=abiotic%20factors" title=" abiotic factors"> abiotic factors</a> </p> <a href="https://publications.waset.org/abstracts/82768/different-response-of-pure-arctic-char-salvelinus-alpinus-and-hybrid-salvelinus-alpinus-vs-salvelinus-fontinalis-mitchill-to-various-hyperoxic-regimes" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/82768.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">182</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1820</span> Parallel Self Organizing Neural Network Based Estimation of Archie’s Parameters and Water Saturation in Sandstone Reservoir</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=G.%20M.%20Hamada">G. M. Hamada</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20A.%20Al-Gathe"> A. A. Al-Gathe</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20M.%20Al-Khudafi"> A. M. Al-Khudafi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Determination of water saturation in sandstone is a vital question to determine the initial oil or gas in place in reservoir rocks. Water saturation determination using electrical measurements is mainly on Archie’s formula. Consequently accuracy of Archie’s formula parameters affects water saturation values rigorously. Determination of Archie’s parameters a, m, and n is proceeded by three conventional techniques, Core Archie-Parameter Estimation (CAPE) and 3-D. This work introduces the hybrid system of parallel self-organizing neural network (PSONN) targeting accepted values of Archie’s parameters and, consequently, reliable water saturation values. This work focuses on Archie’s parameters determination techniques; conventional technique, CAPE technique, and 3-D technique, and then the calculation of water saturation using current. Using the same data, a hybrid parallel self-organizing neural network (PSONN) algorithm is used to estimate Archie’s parameters and predict water saturation. Results have shown that estimated Arche’s parameters m, a, and n are highly accepted with statistical analysis, indicating that the PSONN model has a lower statistical error and higher correlation coefficient. This study was conducted using a high number of measurement points for 144 core plugs from a sandstone reservoir. PSONN algorithm can provide reliable water saturation values, and it can supplement or even replace the conventional techniques to determine Archie’s parameters and thereby calculate water saturation profiles. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=water%20saturation" title="water saturation">water saturation</a>, <a href="https://publications.waset.org/abstracts/search?q=Archie%E2%80%99s%20parameters" title=" Archie’s parameters"> Archie’s parameters</a>, <a href="https://publications.waset.org/abstracts/search?q=artificial%20intelligence" title=" artificial intelligence"> artificial intelligence</a>, <a href="https://publications.waset.org/abstracts/search?q=PSONN" title=" PSONN"> PSONN</a>, <a href="https://publications.waset.org/abstracts/search?q=sandstone%20reservoir" title=" sandstone reservoir"> sandstone reservoir</a> </p> <a href="https://publications.waset.org/abstracts/149641/parallel-self-organizing-neural-network-based-estimation-of-archies-parameters-and-water-saturation-in-sandstone-reservoir" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/149641.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">128</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1819</span> Variability in Saturation Flow and Traffic Performance at Urban Signalized Intersection</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=P.%20N.%20Salini">P. N. Salini</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Anish%20Kini"> B. Anish Kini</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20Ashalatha"> R. Ashalatha</a> </p> <p class="card-text"><strong>Abstract:</strong></p> At signalized intersections with heterogeneous traffic, the percentage share of different vehicle categories have a bearing on the inter-vehicle space utilization, which eventually impacts the saturation flow. This paper analyzed the impact of the percentage share of various vehicle categories in the traffic stream on the saturation flow at signalized intersections by video graphing major intersections with varying geometry in Kerala, India. It was found that as the percentage share of two-wheelers increases, the saturation flow at signalized intersections increases and vice-versa for the percentage share of cars. The effect of bus blockage and parking maneuvers on the saturation flow were also studied. As the distance of bus blockage increases from the stop line, the effect on the saturation flow decreases, while with more buses stopping at the same bus stop, the saturation flow reduces further. The study revealed that with higher kerbside parking maneuvers on the upstream, the saturation flow reduces, and with an increase in the distance of the parking maneuver from the stop line, the effect on the saturation flow decreases. The adjustment factors for bus blockage due to bus stops within 75m downstream and parking maneuvers within 75m upstream of the intersection have been established for mixed traffic conditions. These adjustment factors could empower the urban planners, enforcement personnel and decision-makers to estimate the reduction in the capacity of signalized intersections for suggesting improvements in the form of parking restrictions/ bus stop relocation for existing intersections or make design changes for planned intersections. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=signalized%20intersection" title="signalized intersection">signalized intersection</a>, <a href="https://publications.waset.org/abstracts/search?q=saturation%20flow" title=" saturation flow"> saturation flow</a>, <a href="https://publications.waset.org/abstracts/search?q=adjustment%20factors" title=" adjustment factors"> adjustment factors</a>, <a href="https://publications.waset.org/abstracts/search?q=capacity" title=" capacity"> capacity</a> </p> <a href="https://publications.waset.org/abstracts/131466/variability-in-saturation-flow-and-traffic-performance-at-urban-signalized-intersection" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/131466.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">125</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1818</span> A Diurnal Light Based CO₂ Elevation Strategy for Up-Scaling Chlorella sp. Production by Minimizing Oxygen Accumulation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Venkateswara%20R.%20Naira">Venkateswara R. Naira</a>, <a href="https://publications.waset.org/abstracts/search?q=Debasish%20Das"> Debasish Das</a>, <a href="https://publications.waset.org/abstracts/search?q=Soumen%20K.%20Maiti"> Soumen K. Maiti</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Achieving high cell densities of microalgae under obligatory light-limiting and high light conditions of diurnal (low-high-low variations of daylight intensity) sunlight are further limited by CO₂ supply and dissolved oxygen (DO) accumulation in large-scale photobioreactors. High DO levels cause low growth due to photoinhibition and/or photorespiration. Hence, scalable elevated CO₂ levels (% in air) and their effect on DO accumulation in a 10 L cylindrical membrane photobioreactor (a vertical tubular type) are studied in the present study. The CO₂ elevation strategies; biomass-based, pH control based (types II & I) and diurnal light based, were explored to study the growth of Chlorella sp. FC2 IITG under single-sided LED lighting in the laboratory, mimicking diurnal sunlight. All the experiments were conducted in fed-batch mode by maintaining N and P sources at least 50% of initial concentrations of the optimized BG-11 medium. It was observed that biomass-based (2% - 1st day, 2.5% - 2nd day and 3% - thereafter) and well-known pH control based, type-I (5.8 pH throughout) strategies were found lethal for FC2 growth. In both strategies, the highest peak DO accumulation of 150% air saturation was resulted due to high photosynthetic activity caused by higher CO₂ levels. In the pH control based type-I strategy, automatically resulted CO₂ levels for pH control were recorded so high (beyond the inhibition range, 5%). However, pH control based type-II strategy (5.8 – 2 days, 6.3 – 3 days, 6.7 – thereafter) showed final biomass titer up to 4.45 ± 0.05 g L⁻¹ with peak DO of 122% air saturation; high CO₂ levels beyond 5% (in air) were recorded thereafter. Thus, it became sustainable for obtaining high biomass. Finally, a diurnal light based (2% - low light, 2.5 % - medium light and 3% - high light) strategy was applied on the basis of increasing/decreasing photosynthesis due to increase/decrease in diurnal light intensity. It has resulted in maximum final biomass titer of 5.33 ± 0.12 g L⁻¹, with total biomass productivity of 0.59 ± 0.01 g L⁻¹ day⁻¹. The values are remarkably higher than constant 2% CO₂ level (final biomass titer: 4.26 ± 0.09 g L⁻¹; biomass productivity: 0.27 ± 0.005 g L⁻¹ day⁻¹). However, 135% air saturation of peak DO was observed. Thus, the diurnal light based elevation should be further improved by using CO₂ enriched N₂ instead of air. To the best of knowledge, the light-based CO₂ elevation strategy is not reported elsewhere. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Chlorella%20sp." title="Chlorella sp.">Chlorella sp.</a>, <a href="https://publications.waset.org/abstracts/search?q=CO%E2%82%82%20elevation%20strategy" title=" CO₂ elevation strategy"> CO₂ elevation strategy</a>, <a href="https://publications.waset.org/abstracts/search?q=dissolved%20oxygen%20accumulation" title=" dissolved oxygen accumulation"> dissolved oxygen accumulation</a>, <a href="https://publications.waset.org/abstracts/search?q=diurnal%20light%20based%20CO%E2%82%82%20elevation" title=" diurnal light based CO₂ elevation"> diurnal light based CO₂ elevation</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20cell%20density" title=" high cell density"> high cell density</a>, <a href="https://publications.waset.org/abstracts/search?q=microalgae" title=" microalgae"> microalgae</a>, <a href="https://publications.waset.org/abstracts/search?q=scale-up" title=" scale-up"> scale-up</a> </p> <a href="https://publications.waset.org/abstracts/98393/a-diurnal-light-based-co2-elevation-strategy-for-up-scaling-chlorella-sp-production-by-minimizing-oxygen-accumulation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/98393.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">125</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1817</span> The Role of Rapid Maxillary Expansion in Managing Obstructive Sleep Apnea in Children: A Literature Review</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Suleman%20Maliha">Suleman Maliha</a>, <a href="https://publications.waset.org/abstracts/search?q=Suleman%20Sidra"> Suleman Sidra</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Obstructive sleep apnea (OSA) is a sleep disorder that can result in behavioral and psychomotor impairments in children. The classical treatment modalities for OSA have been continuous positive airway pressure and adenotonsillectomy. However, orthodontic intervention through rapid maxillary expansion (RME) has also been commonly used to manage skeletal transverse maxillary discrepancies. Aim and objectives: The aim of this study is to determine the efficacy of rapid maxillary expansion in paediatric patients with obstructive sleep apnea by assessing pre and post-treatment mean apnea-hypopnea index (AHI) and oxygen saturations. Methodology: Literature was identified through a rigorous search of the Embase, Pubmed, and CINAHL databases. Articles published from 2012 onwards were selected. The inclusion criteria consisted of patients aged 18 years and under with no systemic disease, adenotonsillar surgery, or hypertrophy who are undergoing RME with AHI measurements before and after treatment. In total, six suitable papers were identified. Results: Three studies assessed patients pre and post-RME at 12 months. The first study consisted of 15 patients with an average age of 7.5 years. Following treatment, they found that RME resulted in both higher oxygen saturations (+ 5.3%) and improved AHI (- 4.2 events). The second study assessed 11 patients aged 5–8 years and also noted improvements, with mean AHI reduction from 6.1 to 2.4 and oxygen saturations increasing from 93.1% to 96.8%. The third study reviewed 14 patients aged 6–9 years and similarly found an AHI reduction from 5.7 to 4.4 and an oxygen saturation increase from 89.8% to 95.5%. All modifications noted in these studies were statistically significant. A long-term study reviewed 23 patients aged 6–12 years post-RME treatment on an annual basis for 12 years. They found that the mean AHI reduced from 12.2 to 0.4, with improved oxygen saturations from 78.9% to 95.1%. Another study assessed 19 patients aged 9-12 years at two months into RME and four months post-treatment. Improvements were also noted at both stages, with an overall reduction of the mean AHI from 16.3 to 0.8 and an overall increase in oxygen saturations from 77.9% to 95.4%. The final study assessed 26 children aged 7-11 years on completion of individual treatment and found an AHI reduction from 6.9 to 5.3. However, the oxygen saturation remained stagnant at 96.0%, but this was not clinically significant. Conclusion: Overall, the current evidence suggests that RME is a promising treatment option for paediatric patients with OSA. It can provide efficient and conservative treatment; however, early diagnosis is crucial. As there are various factors that could be contributing to OSA, it is important that each case is treated on its individual merits. Going forward, there is a need for more randomized control trials with larger cohorts being studied. Research into the long-term effects of RME and potential relapse amongst cases would also be useful. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=orthodontics" title="orthodontics">orthodontics</a>, <a href="https://publications.waset.org/abstracts/search?q=sleep%20apnea" title=" sleep apnea"> sleep apnea</a>, <a href="https://publications.waset.org/abstracts/search?q=maxillary%20expansion" title=" maxillary expansion"> maxillary expansion</a>, <a href="https://publications.waset.org/abstracts/search?q=review" title=" review"> review</a> </p> <a href="https://publications.waset.org/abstracts/157849/the-role-of-rapid-maxillary-expansion-in-managing-obstructive-sleep-apnea-in-children-a-literature-review" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/157849.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">82</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1816</span> A Novel Bio-ceramic Using Hyperthermia for Bone Cancer Therapy, Ferro-substituted Silicate Calcium Materials</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=hassan%20gheisari">hassan gheisari</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Ferro silicate calcium nano particles are prepared through the sol-gel method using polyvinyl alcohol (PVA) as a chelating agent. The powder, as prepared, is annealed at three different temperatures (900 ºC, 1000 ºC, and 1100 ºC) for 3 h. The XRD patterns of the samples indicate broad peaks, and the full width at half maximum decreased with increasing annealing temperature. FTIR spectra of the samples confirm the presence of metal - oxygen complexes within the structure. The average particle size obtained from PSA curve demonstrates ultrafine particles. SEM micrographs indicate the particles synthesized have spherical morphology. The saturation magnetization (Ms) and remnant magnetization (Mr) of the samples show dependence on particle size and crystallinity of the samples. The highest saturation magnetization is achieved for the sample annealed at 1100 ºC having maximum average particle size. The high saturation magnetization of the samples suggests the present method is suitable for obtaining nano particles magnetic ferro bioceramic, which is desirable for practical applications such as hyperthermia bone cancer therapy. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hyperthermia" title="hyperthermia">hyperthermia</a>, <a href="https://publications.waset.org/abstracts/search?q=bone%20cancer" title=" bone cancer"> bone cancer</a>, <a href="https://publications.waset.org/abstracts/search?q=bio%20ceramic%3B%20magnetic%20materials%3B%20sol%E2%80%93%20gel" title=" bio ceramic; magnetic materials; sol– gel"> bio ceramic; magnetic materials; sol– gel</a>, <a href="https://publications.waset.org/abstracts/search?q=silicate%20calcium" title=" silicate calcium"> silicate calcium</a> </p> <a href="https://publications.waset.org/abstracts/163836/a-novel-bio-ceramic-using-hyperthermia-for-bone-cancer-therapy-ferro-substituted-silicate-calcium-materials" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/163836.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">73</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1815</span> Ferro-Substituted Silicate Calcium Materials, a Novel Bio-Ceramic Using Hyperthermia for Bone Cancer Therapy</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hassan%20Gheisari">Hassan Gheisari</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Ferro silicate calcium nano particles are prepared through the sol-gel method using polyvinyl alcohol (PVA) as a chelating agent. The powder as prepared is annealed at three different temperatures (900 ºC, 1000 ºC and 1100 ºC) for 3 h. The XRD patterns of the samples indicate broad peaks and the full width at half maximum decreased with increasing annealing temperature. FTIR spectra of the samples confirm the presence of metal - oxygen complexes within the structure. The average particle size obtained from PSA curve demonstrates ultrafine particles. SEM micrographs indicate the particles synthesized have spherical morphology. The saturation magnetization (Ms) and remnant magnetization (Mr) of the samples show dependence on particle size and crystallinity of the samples. The highest saturation magnetization is achieved for the sample annealed at 1100 ºC having maximum average particle size. The high saturation magnetization of the samples suggests the present method is suitable for obtaining nano particles magnetic ferro bioceramic which is desirable for practical applications such as hyperthermia bone cancer therapy. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hyperthermia" title="hyperthermia">hyperthermia</a>, <a href="https://publications.waset.org/abstracts/search?q=bone%20cancer" title=" bone cancer"> bone cancer</a>, <a href="https://publications.waset.org/abstracts/search?q=bio%20ceramic" title=" bio ceramic"> bio ceramic</a>, <a href="https://publications.waset.org/abstracts/search?q=magnetic%20materials" title=" magnetic materials"> magnetic materials</a>, <a href="https://publications.waset.org/abstracts/search?q=sol%E2%80%93%20gel" title=" sol– gel"> sol– gel</a>, <a href="https://publications.waset.org/abstracts/search?q=silicate%20calcium" title=" silicate calcium"> silicate calcium</a> </p> <a href="https://publications.waset.org/abstracts/39463/ferro-substituted-silicate-calcium-materials-a-novel-bio-ceramic-using-hyperthermia-for-bone-cancer-therapy" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/39463.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">308</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1814</span> Assessment of the Physical and Chemical Characteristics of Ugbogui River, Edo State, Nigeria</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Iyagbaye%20O.%20Rich">Iyagbaye O. Rich</a>, <a href="https://publications.waset.org/abstracts/search?q=Omoigberale%20O.%20Michael"> Omoigberale O. Michael</a>, <a href="https://publications.waset.org/abstracts/search?q=Iyagbaye%20A.%20Louis"> Iyagbaye A. Louis</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The physical, chemical parameters and some trace contents of Ugbogui in Edo State, Nigeria were investigated from August 2015 to April 2016. Four stations were studied from upstream to downstream using standard methods. A total of thirty-three (33) physical and chemical characteristics and trace metal contents were examined; Air and water temperatures, depth, transparency, colour, turbidity, flow velocity, pH, total alkalinity, conductivity and dissolved solids etc. Other includes dissolved oxygen, oxygen saturation, biochemical oxygen demand, chloride, phosphate, sodium, nitrate, sulphate, potassium, calcium, magnesium, iron, lead, copper, zinc, nickel, cadmium, vanadium and chromium. Eleven (11) parameters exhibited clear seasonal variations. However, there were high significant differences (p < 0.01) in the values of depth, colour, total suspended solid, biochemical oxygen demand, chemical oxygen demand, chloride, bicarbonate, phosphate, sulphate, iron, manganese, zinc, copper, chromium and cadmium among the stations. The anthropogenic activities had negatively impacted at station 3 of the river, although most of the recorded values were still within permissible limits. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=anthropogenic%20activities" title="anthropogenic activities">anthropogenic activities</a>, <a href="https://publications.waset.org/abstracts/search?q=Nigeria" title=" Nigeria"> Nigeria</a>, <a href="https://publications.waset.org/abstracts/search?q=permissible%20limits" title=" permissible limits"> permissible limits</a>, <a href="https://publications.waset.org/abstracts/search?q=physical%20and%20chemical%20parameters" title=" physical and chemical parameters"> physical and chemical parameters</a>, <a href="https://publications.waset.org/abstracts/search?q=trace%20metal" title=" trace metal"> trace metal</a>, <a href="https://publications.waset.org/abstracts/search?q=water%20quality" title=" water quality"> water quality</a> </p> <a href="https://publications.waset.org/abstracts/97178/assessment-of-the-physical-and-chemical-characteristics-of-ugbogui-river-edo-state-nigeria" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/97178.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">126</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1813</span> Oil Displacement by Water in Hauterivian Sandstone Reservoir of Kashkari Oil Field</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=A.%20J.%20Nazari">A. J. Nazari</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20Honma"> S. Honma</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper evaluates oil displacement by water in Hauterivian sandstone reservoir of Kashkari oil field in North of Afghanistan. The core samples of this oil field were taken out from well No-21<sup>st</sup>, and the relative permeability and fractional flow are analyzed. Steady state flow laboratory experiments are performed to empirically obtain the fractional flow curves and relative permeability in different water saturation ratio. The relative permeability represents the simultaneous flow behavior in the reservoir. The fractional flow approach describes the individual phases as fractional of the total flow. The fractional flow curve interprets oil displacement by water, and from the tangent of fractional flow curve can find out the average saturation behind the water front flow saturation. Therefore, relative permeability and fractional flow curves are suitable for describing the displacement of oil by water in a petroleum reservoir. The effects of irreducible water saturation, residual oil saturation on the displaceable amount of oil are investigated through Buckley-Leveret analysis. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fractional%20flow" title="fractional flow">fractional flow</a>, <a href="https://publications.waset.org/abstracts/search?q=oil%20displacement" title=" oil displacement"> oil displacement</a>, <a href="https://publications.waset.org/abstracts/search?q=relative%20permeability" title=" relative permeability"> relative permeability</a>, <a href="https://publications.waset.org/abstracts/search?q=simultaneously%20flow" title=" simultaneously flow"> simultaneously flow</a> </p> <a href="https://publications.waset.org/abstracts/59190/oil-displacement-by-water-in-hauterivian-sandstone-reservoir-of-kashkari-oil-field" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/59190.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">392</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1812</span> Power MOSFET Models Including Quasi-Saturation Effect</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Abdelghafour%20Galadi">Abdelghafour Galadi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, accurate power MOSFET models including quasi-saturation effect are presented. These models have no internal node voltages determined by the circuit simulator and use one JFET or one depletion mode MOSFET transistors controlled by an “effective” gate voltage taking into account the quasi-saturation effect. The proposed models achieve accurate simulation results with an average error percentage less than 9%, which is an improvement of 21 percentage points compared to the commonly used standard power MOSFET model. In addition, the models can be integrated in any available commercial circuit simulators by using their analytical equations. A description of the models will be provided along with the parameter extraction procedure. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=power%20MOSFET" title="power MOSFET">power MOSFET</a>, <a href="https://publications.waset.org/abstracts/search?q=drift%20layer" title=" drift layer"> drift layer</a>, <a href="https://publications.waset.org/abstracts/search?q=quasi-saturation%20effect" title=" quasi-saturation effect"> quasi-saturation effect</a>, <a href="https://publications.waset.org/abstracts/search?q=SPICE%20model" title=" SPICE model"> SPICE model</a> </p> <a href="https://publications.waset.org/abstracts/54686/power-mosfet-models-including-quasi-saturation-effect" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/54686.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">194</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1811</span> A Method to Saturation Modeling of Synchronous Machines in d-q Axes</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20Arbi%20Khlifi">Mohamed Arbi Khlifi</a>, <a href="https://publications.waset.org/abstracts/search?q=Badr%20M.%20Alshammari"> Badr M. Alshammari</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper discusses the general methods to saturation in the steady-state, two axis (d & q) frame models of synchronous machines. In particular, the important role of the magnetic coupling between the d-q axes (cross-magnetizing phenomenon), is demonstrated. For that purpose, distinct methods of saturation modeling of dumper synchronous machine with cross-saturation are identified, and detailed models synthesis in d-q axes. A number of models are given in the final developed form. The procedure and the novel models are verified by a critical application to prove the validity of the method and the equivalence between all developed models is reported. Advantages of some of the models over the existing ones and their applicability are discussed. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cross-magnetizing" title="cross-magnetizing">cross-magnetizing</a>, <a href="https://publications.waset.org/abstracts/search?q=models%20synthesis" title=" models synthesis"> models synthesis</a>, <a href="https://publications.waset.org/abstracts/search?q=synchronous%20machine" title=" synchronous machine"> synchronous machine</a>, <a href="https://publications.waset.org/abstracts/search?q=saturated%20modeling" title=" saturated modeling"> saturated modeling</a>, <a href="https://publications.waset.org/abstracts/search?q=state-space%20vectors" title=" state-space vectors"> state-space vectors</a> </p> <a href="https://publications.waset.org/abstracts/31947/a-method-to-saturation-modeling-of-synchronous-machines-in-d-q-axes" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/31947.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">454</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1810</span> Effect of Inspiratory Muscle Training on Diaphragmatic Strength Following Coronary Revascularization</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Abeer%20Ahmed%20Abdelhamed"> Abeer Ahmed Abdelhamed</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: Postoperative pulmonary complications (PPCs) are the most common complications observed and managed after abdominal or cardiothoracic surgery. Hypoxemia, atelectasis, pleural effusion, or diaphragmatic dysfunction, are often a source of morbidity in cardiac surgery patients, and are more common in patients receiving unilateral or bilateral internal mammary artery (IMT) grafts than patients receiving saphenous vein (SV) grafts alone. Purpose: The aim of this work was to investigate the effect of Threshold load inspiratory muscle training on pulmonary gas exchange and maximum inspiratory pressure (MIP) in patient undergoing coronary revascularization. Subject: Thirty three male patients eligible for coronary revascularization were selected to participate in the study. Method: They were divided into two groups(17 patients in the intervention group and 16 patients in the control group), the interventional group received inspiratory muscle training at 30% of their maximum inspiratory pressure throughout the hospitalization period in addition to routine post operative care. Result: The results of this study showed a significant improvement on maximum inspiratory pressure(MIP), Arterial-alveolar pressure gradient (A-a gradient) and oxygen saturation in the intervention group. Conclusion: Inspiratory muscle training using threshold mode significantly improves maximum inspiratory pressure, pulmonary gas exchange tested by alveolar-arterial gradient and oxygen saturation in Patients undergoing coronary revascularization. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=coronary%20revascularization" title="coronary revascularization">coronary revascularization</a>, <a href="https://publications.waset.org/abstracts/search?q=inspiratory%20muscle%20training" title=" inspiratory muscle training"> inspiratory muscle training</a>, <a href="https://publications.waset.org/abstracts/search?q=maximum%20inspiratory%20pressure" title=" maximum inspiratory pressure"> maximum inspiratory pressure</a>, <a href="https://publications.waset.org/abstracts/search?q=pulmonary%20gas%20exchange" title=" pulmonary gas exchange"> pulmonary gas exchange</a> </p> <a href="https://publications.waset.org/abstracts/31159/effect-of-inspiratory-muscle-training-on-diaphragmatic-strength-following-coronary-revascularization" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/31159.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">300</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1809</span> Current Status of Nitrogen Saturation in the Upper Reaches of the Kanna River, Japan</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sakura%20Yoshii">Sakura Yoshii</a>, <a href="https://publications.waset.org/abstracts/search?q=Masakazu%20Abe"> Masakazu Abe</a>, <a href="https://publications.waset.org/abstracts/search?q=Akihiro%20Iijima"> Akihiro Iijima</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Nitrogen saturation has become one of the serious issues in the field of forest environment. The watershed protection forests located in the downwind hinterland of Tokyo Metropolitan Area are believed to be facing nitrogen saturation. In this study, we carefully focus on the balance of nitrogen between load and runoff. Annual nitrogen load via atmospheric deposition was estimated to 461.1 t-N/year in the upper reaches of the Kanna River. Annual nitrogen runoff to the forested headwater stream of the Kanna River was determined to 184.9 t-N/year, corresponding to 40.1% of the total nitrogen load. Clear seasonal change in NO3-N concentration was still observed. Therefore, watershed protection forest of the Kanna River is most likely to be in Stage-1 on the status of nitrogen saturation. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=atmospheric%20deposition" title="atmospheric deposition">atmospheric deposition</a>, <a href="https://publications.waset.org/abstracts/search?q=nitrogen%20accumulation" title=" nitrogen accumulation"> nitrogen accumulation</a>, <a href="https://publications.waset.org/abstracts/search?q=denitrification" title=" denitrification"> denitrification</a>, <a href="https://publications.waset.org/abstracts/search?q=forest%20ecosystems" title=" forest ecosystems"> forest ecosystems</a> </p> <a href="https://publications.waset.org/abstracts/3246/current-status-of-nitrogen-saturation-in-the-upper-reaches-of-the-kanna-river-japan" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/3246.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">276</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1808</span> The Amount of Organic Phosphates (Like DPG) Existing in Blood is Determining Factor of Mammal’s Bulk</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ramin%20Amirmardfar">Ramin Amirmardfar</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Throughout Necessary oxygen should be supplied for all cells of a mammal at any moment through blood to make it possible remain alive all cells the mammal’s body. In case a mammal’s bulk is large, there is a farther distance between cells in different tissues and mammals’ heart. Therefore red blood cells in bulky mammal’s body should be capable of conveying oxygen to farther distances. To make it practical, oxygen should be glued red blood cells tenaciously. In other words, cohesion strength of oxygen to red blood cell of bulky mammal’s blood should be much more than the same of small mammal’s blood. In mammal’s bodies, the controlling factor of amount of cohesion of oxygen to red blood cell, are organic phosphates (like DPG). The less DPG in red blood cells of a mammal, the more cohesion of oxygen to red blood cell (at the same rate). As much as oxygen is glued more tenacious to red blood cells, oxygen could been carried to farther distance and as much as oxygen could be conveyed to farther points of heart, bulk of mammal could be larger at the same rate. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=mammals%20size" title="mammals size">mammals size</a>, <a href="https://publications.waset.org/abstracts/search?q=animals%20size" title=" animals size"> animals size</a>, <a href="https://publications.waset.org/abstracts/search?q=organic%20phosphates" title=" organic phosphates"> organic phosphates</a>, <a href="https://publications.waset.org/abstracts/search?q=DPG" title=" DPG"> DPG</a>, <a href="https://publications.waset.org/abstracts/search?q=red%20blood%20cell" title=" red blood cell"> red blood cell</a>, <a href="https://publications.waset.org/abstracts/search?q=metabolism" title=" metabolism"> metabolism</a> </p> <a href="https://publications.waset.org/abstracts/12665/the-amount-of-organic-phosphates-like-dpg-existing-in-blood-is-determining-factor-of-mammals-bulk" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/12665.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">355</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">‹</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=61">61</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=62">62</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=oxygen%20saturation&page=2" rel="next">›</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">© 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">×</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>