CINXE.COM

Search results for: CR-39 detector

<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: CR-39 detector</title> <meta name="description" content="Search results for: CR-39 detector"> <meta name="keywords" content="CR-39 detector"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="CR-39 detector" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="CR-39 detector"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 398</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: CR-39 detector</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">398</span> Development and Evaluation of a Portable Ammonia Gas Detector</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jaheon%20Gu">Jaheon Gu</a>, <a href="https://publications.waset.org/abstracts/search?q=Wooyong%20Chung"> Wooyong Chung</a>, <a href="https://publications.waset.org/abstracts/search?q=Mijung%20Koo"> Mijung Koo</a>, <a href="https://publications.waset.org/abstracts/search?q=Seonbok%20Lee"> Seonbok Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Gyoutae%20Park"> Gyoutae Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Sangguk%20Ahn"> Sangguk Ahn</a>, <a href="https://publications.waset.org/abstracts/search?q=Hiesik%20Kim"> Hiesik Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Jungil%20Park"> Jungil Park</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, we present a portable ammonia gas detector for performing the gas safety management efficiently. The display of the detector is separated from its body. The display module is received the data measured from the detector using ZigBee. The detector has a rechargeable li-ion battery which can be use for 11~12 hours, and a Bluetooth module for sending the data to the PC or the smart devices. The data are sent to the server and can access using the web browser or mobile application. The range of the detection concentration is 0~100ppm. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=ammonia" title="ammonia">ammonia</a>, <a href="https://publications.waset.org/abstracts/search?q=detector" title=" detector"> detector</a>, <a href="https://publications.waset.org/abstracts/search?q=gas" title=" gas"> gas</a>, <a href="https://publications.waset.org/abstracts/search?q=portable" title=" portable"> portable</a> </p> <a href="https://publications.waset.org/abstracts/48045/development-and-evaluation-of-a-portable-ammonia-gas-detector" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/48045.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">417</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">397</span> Investigation of the Effect of Pressure Changes on the Gas Proportional Detector</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=S.%20M.%20Golgoun">S. M. Golgoun</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20M.%20Taheri"> S. M. Taheri</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Investigation of radioactive contamination of personnel working in radiation centers to identify radioactive materials and then measure the potential contamination and eliminate it has always been considered. For this purpose, various ways have been proposed so far and different devices have been designed and built. Gas sealed proportional counter has special working conditions. In this research, a gas sealed detector of proportional counter type was made and then its various parameters were investigated. Some parameters are influential on their working conditions and one of these most important parameters is the internal pressure of the proportional gas-filled detector. In this experimental research, we produced software for examination and altering high voltage, registering data, and calculating efficiency. By this, we investigated different gas pressure effects on detector efficiency and proposed optimizing working conditions of this detector. After reviewing the results, we suggested a range between 20-30 mbar pressure for this gas sealed detector. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=gas%20sealed" title="gas sealed">gas sealed</a>, <a href="https://publications.waset.org/abstracts/search?q=proportional%20detector" title=" proportional detector"> proportional detector</a>, <a href="https://publications.waset.org/abstracts/search?q=pressure" title=" pressure"> pressure</a>, <a href="https://publications.waset.org/abstracts/search?q=counter" title=" counter"> counter</a> </p> <a href="https://publications.waset.org/abstracts/146316/investigation-of-the-effect-of-pressure-changes-on-the-gas-proportional-detector" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/146316.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">119</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">396</span> Determination of Unknown Radionuclides Using High Purity Germanium Detectors</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=O.%20G.%20Onuk">O. G. Onuk</a>, <a href="https://publications.waset.org/abstracts/search?q=L.%20S.%20Taura"> L. S. Taura</a>, <a href="https://publications.waset.org/abstracts/search?q=C.%20M.%20Eze"> C. M. Eze</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20M.%20Ngaram"> S. M. Ngaram</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The decay chain of radioactive elements in the laboratory and the verification of natural radioactivity of the human body was investigated using the High Purity Germanium (HPGe) detector. Properties of the HPGe detectors were also investigated. The efficiency and energy resolution of HPGe detector used in the laboratory was found to be excellent. The detector was calibrated three times so as to cover a wider energy range. Also the Centroid C of the detector was found to have a linear relationship with the energies of the known gamma-rays. Using the three calibrations of the detector, the energy of an unknown radionuclide was found to follow the decay chain of thorium-232 (232Th) and it was also found that an average adult has about 2.5g Potasium-40 (40K) in the body. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=detector" title="detector">detector</a>, <a href="https://publications.waset.org/abstracts/search?q=efficiency" title=" efficiency"> efficiency</a>, <a href="https://publications.waset.org/abstracts/search?q=energy" title=" energy"> energy</a>, <a href="https://publications.waset.org/abstracts/search?q=radionuclides" title=" radionuclides"> radionuclides</a>, <a href="https://publications.waset.org/abstracts/search?q=resolution" title=" resolution"> resolution</a> </p> <a href="https://publications.waset.org/abstracts/83964/determination-of-unknown-radionuclides-using-high-purity-germanium-detectors" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/83964.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">250</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">395</span> Cosmic Background Reduction in the Radiocarbon Measurements by Liquid Scintillation Spectrometry</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Natasa%20Todorovic">Natasa Todorovic</a>, <a href="https://publications.waset.org/abstracts/search?q=Jovana%20Nikolov">Jovana Nikolov</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Guard detector efficiency, cosmic background, and its variation were determinate using ultra low-level liquid scintillation spectrometer Quantulus 1220, equipped with an anti-Compton guard detector, in the surface laboratory at the University of Novi Sad, Serbia, Atmospheric pressure variation has an observable effect on the anti-Compton guard detector count rate. and the cosmic muon flux is lower during a high-pressure period. Also, the guard detector Compton continuum provides a good view of the level of gamma radiation in the laboratory environment. The efficiency of the guard detector in the channel interval from 750 to 1024 was assessed to 93.45%; efficiency in the entire window (channels 1 to 1024) was 75.23%, which is in good agreement with literature data. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cosmic%20radiation" title="cosmic radiation">cosmic radiation</a>, <a href="https://publications.waset.org/abstracts/search?q=background%20reduction" title=" background reduction"> background reduction</a>, <a href="https://publications.waset.org/abstracts/search?q=liquid%20scintillation%20counting" title=" liquid scintillation counting"> liquid scintillation counting</a>, <a href="https://publications.waset.org/abstracts/search?q=guard%20detector%20efficiency" title=" guard detector efficiency"> guard detector efficiency</a> </p> <a href="https://publications.waset.org/abstracts/140808/cosmic-background-reduction-in-the-radiocarbon-measurements-by-liquid-scintillation-spectrometry" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/140808.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">157</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">394</span> Performance Analysis of the Time-Based and Periodogram-Based Energy Detector for Spectrum Sensing</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sadaf%20Nawaz">Sadaf Nawaz</a>, <a href="https://publications.waset.org/abstracts/search?q=Adnan%20Ahmed%20Khan"> Adnan Ahmed Khan</a>, <a href="https://publications.waset.org/abstracts/search?q=Asad%20Mahmood"> Asad Mahmood</a>, <a href="https://publications.waset.org/abstracts/search?q=Chaudhary%20Farrukh%20Javed"> Chaudhary Farrukh Javed </a> </p> <p class="card-text"><strong>Abstract:</strong></p> Classically, an energy detector is implemented in time domain (TD). However, frequency domain (FD) based energy detector has demonstrated an improved performance. This paper presents a comparison between the two approaches as to analyze their pros and cons. A detailed performance analysis of the classical TD energy-detector and the periodogram based detector is performed. Exact and approximate mathematical expressions for probability of false alarm (Pf) and probability of detection (Pd) are derived for both approaches. The derived expressions naturally lead to an analytical as well as intuitive reasoning for the improved performance of (Pf) and (Pd) in different scenarios. Our analysis suggests the dependence improvement on buffer sizes. Pf is improved in FD, whereas Pd is enhanced in TD based energy detectors. Finally, Monte Carlo simulations results demonstrate the analysis reached by the derived expressions. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cognitive%20radio" title="cognitive radio">cognitive radio</a>, <a href="https://publications.waset.org/abstracts/search?q=energy%20detector" title=" energy detector"> energy detector</a>, <a href="https://publications.waset.org/abstracts/search?q=periodogram" title=" periodogram"> periodogram</a>, <a href="https://publications.waset.org/abstracts/search?q=spectrum%20sensing" title=" spectrum sensing"> spectrum sensing</a> </p> <a href="https://publications.waset.org/abstracts/63028/performance-analysis-of-the-time-based-and-periodogram-based-energy-detector-for-spectrum-sensing" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/63028.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">377</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">393</span> Using the Timepix Detector at CERN Accelerator Facilities</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Andrii%20Natochii">Andrii Natochii</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The UA9 collaboration in the last two years has installed two different types of detectors to investigate the channeling effect in the bent silicon crystals with high-energy particles beam on the CERN accelerator facilities: Cherenkov detector CpFM and silicon pixel detector Timepix. In the current work, we describe the main performances of the Timepix detector operation at the SPS and H8 extracted beamline at CERN. We are presenting some detector calibration results and tuning. Our research topics also cover a cluster analysis algorithm for the particle hits reconstruction. We describe the optimal acquisition setup for the Timepix device and the edges of its functionality for the high energy and flux beam monitoring. The measurements of the crystal parameters are very important for the future bent crystal applications and needs a track reconstruction apparatus. Thus, it was decided to construct a short range (1.2 m long) particle telescope based on the Timepix sensors and test it at H8 SPS extraction beamline. The obtained results will be shown as well. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=beam%20monitoring" title="beam monitoring">beam monitoring</a>, <a href="https://publications.waset.org/abstracts/search?q=channeling" title=" channeling"> channeling</a>, <a href="https://publications.waset.org/abstracts/search?q=particle%20tracking" title=" particle tracking"> particle tracking</a>, <a href="https://publications.waset.org/abstracts/search?q=Timepix%20detector" title=" Timepix detector"> Timepix detector</a> </p> <a href="https://publications.waset.org/abstracts/101942/using-the-timepix-detector-at-cern-accelerator-facilities" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/101942.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">180</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">392</span> Development of Alpha Spectroscopy Method with Solid State Nuclear Track Detector Using Aluminium Thin Films</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Nidal%20Dwaikat">Nidal Dwaikat</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This work presents the development of alpha spectroscopy method with Solid-state nuclear track detectors using aluminum thin films. The resolution of this method is high, and it is able to discriminate between alpha particles at different incident energy. It can measure the exact number of alpha particles at specific energy without needing a calibration of alpha track diameter versus alpha energy. This method was tested by using Cf-252 alpha standard source at energies 5.11 Mev, 3.86 MeV and 2.7 MeV, which produced by the variation of detector -standard source distance. On front side, two detectors were covered with two Aluminum thin films and the third detector was kept uncovered. The thickness of Aluminum thin films was selected carefully (using SRIM 2013) such that one of the films will block the lower two alpha particles (3.86 MeV and 2.7 MeV) and the alpha particles at higher energy (5.11 Mev) can penetrate the film and reach the detector’s surface. The second thin film will block alpha particles at lower energy of 2.7 MeV and allow alpha particles at higher two energies (5.11 Mev and 3.86 MeV) to penetrate and produce tracks. For uncovered detector, alpha particles at three different energies can produce tracks on it. For quality assurance and accuracy, the detectors were mounted on thick enough copper substrates to block exposure from the backside. The tracks on the first detector are due to alpha particles at energy of 5.11 MeV. The difference between the tracks number on the first detector and the tracks number on the second detector is due to alpha particles at energy of 3.8 MeV. Finally, by subtracting the tracks number on the second detector from the tracks number on the third detector (uncovered), we can find the tracks number due to alpha particles at energy 2.7 MeV. After knowing the efficiency calibration factor, we can exactly calculate the activity of standard source. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=aluminium%20thin%20film" title="aluminium thin film">aluminium thin film</a>, <a href="https://publications.waset.org/abstracts/search?q=alpha%20particles" title=" alpha particles"> alpha particles</a>, <a href="https://publications.waset.org/abstracts/search?q=copper%20substrate" title=" copper substrate"> copper substrate</a>, <a href="https://publications.waset.org/abstracts/search?q=CR-39%20detector" title=" CR-39 detector"> CR-39 detector</a> </p> <a href="https://publications.waset.org/abstracts/41596/development-of-alpha-spectroscopy-method-with-solid-state-nuclear-track-detector-using-aluminium-thin-films" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/41596.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">365</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">391</span> Determination of Full Energy Peak Efficiency and Resolution of Nai (Tl) Detector Using Gamma-ray Spectroscopy</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jibon%20Sharma">Jibon Sharma</a>, <a href="https://publications.waset.org/abstracts/search?q=Alakjyoti%20Patowary"> Alakjyoti Patowary</a>, <a href="https://publications.waset.org/abstracts/search?q=Moirangthem%20Nara%20Singh"> Moirangthem Nara Singh</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In experimental research it is very much essential to obtain the quality control of the system used for the experiment. NaI (Tl) scintillation detector is the most commonly used in radiation and medical physics for measurement of the gamma ray activity of various samples. In addition, the scintillation detector has a lot of applications in the elemental analysis of various compounds, alloys using activation analysis. In each application for quantitative analysis, it is very much essential to know the detection efficiency and resolution for different gamma energies. In this work, the energy dependence of efficiency and resolution of NaI (Tl) detector using gamma-ray spectroscopy are investigated. Different photon energies of 356.01 keV,511keV,661.60keV,1170 keV,1274.53 keV and 1330 keV are obtained from four radioactive sources (133Ba,22Na,137Cs and 60 Co) used in these studies. Values of full energy peak efficiencies of these gamma energies are found to be respectively 58.46%,10.15%,14.39%,1.4%,3.27% and 1.31%. The values of percent resolution for above different gamma ray energies are found to be 11.27%,7.27%,6.38%,5.17%,4.86% and 4.74% respectively. It was found that the efficiency of the detector exponentially decreases with energy and the resolution of the detector is directly proportional to the energy of gamma-ray. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=naI%20%28Tl%29%20gamma-ray%20spectrometer" title="naI (Tl) gamma-ray spectrometer">naI (Tl) gamma-ray spectrometer</a>, <a href="https://publications.waset.org/abstracts/search?q=resolution" title=" resolution"> resolution</a>, <a href="https://publications.waset.org/abstracts/search?q=full%20energy%20peak%20efficiency" title=" full energy peak efficiency"> full energy peak efficiency</a>, <a href="https://publications.waset.org/abstracts/search?q=radioactive%20sources" title=" radioactive sources"> radioactive sources</a> </p> <a href="https://publications.waset.org/abstracts/158239/determination-of-full-energy-peak-efficiency-and-resolution-of-nai-tl-detector-using-gamma-ray-spectroscopy" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/158239.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">104</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">390</span> Day/Night Detector for Vehicle Tracking in Traffic Monitoring Systems</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Taha">M. Taha</a>, <a href="https://publications.waset.org/abstracts/search?q=Hala%20H.%20Zayed"> Hala H. Zayed</a>, <a href="https://publications.waset.org/abstracts/search?q=T.%20Nazmy"> T. Nazmy</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Khalifa"> M. Khalifa</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Recently, traffic monitoring has attracted the attention of computer vision researchers. Many algorithms have been developed to detect and track moving vehicles. In fact, vehicle tracking in daytime and in nighttime cannot be approached with the same techniques, due to the extreme different illumination conditions. Consequently, traffic-monitoring systems are in need of having a component to differentiate between daytime and nighttime scenes. In this paper, a HSV-based day/night detector is proposed for traffic monitoring scenes. The detector employs the hue-histogram and the value-histogram on the top half of the image frame. Experimental results show that the extraction of the brightness features along with the color features within the top region of the image is effective for classifying traffic scenes. In addition, the detector achieves high precision and recall rates along with it is feasible for real time applications. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=day%2Fnight%20detector" title="day/night detector">day/night detector</a>, <a href="https://publications.waset.org/abstracts/search?q=daytime%2Fnighttime%20classification" title=" daytime/nighttime classification"> daytime/nighttime classification</a>, <a href="https://publications.waset.org/abstracts/search?q=image%20classification" title=" image classification"> image classification</a>, <a href="https://publications.waset.org/abstracts/search?q=vehicle%20tracking" title=" vehicle tracking"> vehicle tracking</a>, <a href="https://publications.waset.org/abstracts/search?q=traffic%20monitoring" title=" traffic monitoring"> traffic monitoring</a> </p> <a href="https://publications.waset.org/abstracts/34948/daynight-detector-for-vehicle-tracking-in-traffic-monitoring-systems" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/34948.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">555</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">389</span> The Next Generation Neutrinoless Double-Beta Decay Experiment nEXO</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ryan%20Maclellan">Ryan Maclellan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The nEXO Collaboration is designing a very large detector for neutrinoless double beta decay of Xe-136. The nEXO detector is rooted in the current EXO-200 program, which has reached a sensitivity for the half-life of the decay of 1.9x10^25 years with an exposure of 99.8 kg-y. The baseline nEXO design assumes 5 tonnes of liquid xenon, enriched in the mass 136 isotope, within a time projection chamber. The detector is being designed to reach a half-life sensitivity of > 5x10^27 years covering the inverted neutrino mass hierarchy, with 5 years of data. We present the nEXO detector design, the current status of R&D efforts, and the physics case for the experiment. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=double-beta" title="double-beta">double-beta</a>, <a href="https://publications.waset.org/abstracts/search?q=Majorana" title=" Majorana"> Majorana</a>, <a href="https://publications.waset.org/abstracts/search?q=neutrino" title=" neutrino"> neutrino</a>, <a href="https://publications.waset.org/abstracts/search?q=neutrinoless" title=" neutrinoless"> neutrinoless</a> </p> <a href="https://publications.waset.org/abstracts/34405/the-next-generation-neutrinoless-double-beta-decay-experiment-nexo" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/34405.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">423</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">388</span> Basic Study of Mammographic Image Magnification System with Eye-Detector and Simple EEG Scanner</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Aika%20Umemuro">Aika Umemuro</a>, <a href="https://publications.waset.org/abstracts/search?q=Mitsuru%20Sato"> Mitsuru Sato</a>, <a href="https://publications.waset.org/abstracts/search?q=Mizuki%20Narita"> Mizuki Narita</a>, <a href="https://publications.waset.org/abstracts/search?q=Saya%20Hori"> Saya Hori</a>, <a href="https://publications.waset.org/abstracts/search?q=Saya%20Sakurai"> Saya Sakurai</a>, <a href="https://publications.waset.org/abstracts/search?q=Tomomi%20Nakayama"> Tomomi Nakayama</a>, <a href="https://publications.waset.org/abstracts/search?q=Ayano%20Nakazawa"> Ayano Nakazawa</a>, <a href="https://publications.waset.org/abstracts/search?q=Toshihiro%20Ogura"> Toshihiro Ogura</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Mammography requires the detection of very small calcifications, and physicians search for microcalcifications by magnifying the images as they read them. The mouse is necessary to zoom in on the images, but this can be tiring and distracting when many images are read in a single day. Therefore, an image magnification system combining an eye-detector and a simple electroencephalograph (EEG) scanner was devised, and its operability was evaluated. Two experiments were conducted in this study: the measurement of eye-detection error using an eye-detector and the measurement of the time required for image magnification using a simple EEG scanner. Eye-detector validation showed that the mean distance of eye-detection error ranged from 0.64 cm to 2.17 cm, with an overall mean of 1.24 ± 0.81 cm for the observers. The results showed that the eye detection error was small enough for the magnified area of the mammographic image. The average time required for point magnification in the verification of the simple EEG scanner ranged from 5.85 to 16.73 seconds, and individual differences were observed. The reason for this may be that the size of the simple EEG scanner used was not adjustable, so it did not fit well for some subjects. The use of a simple EEG scanner with size adjustment would solve this problem. Therefore, the image magnification system using the eye-detector and the simple EEG scanner is useful. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=EEG%20scanner" title="EEG scanner">EEG scanner</a>, <a href="https://publications.waset.org/abstracts/search?q=eye-detector" title=" eye-detector"> eye-detector</a>, <a href="https://publications.waset.org/abstracts/search?q=mammography" title=" mammography"> mammography</a>, <a href="https://publications.waset.org/abstracts/search?q=observers" title=" observers"> observers</a> </p> <a href="https://publications.waset.org/abstracts/155822/basic-study-of-mammographic-image-magnification-system-with-eye-detector-and-simple-eeg-scanner" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/155822.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">215</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">387</span> A Large Ion Collider Experiment (ALICE) Diffractive Detector Control System for RUN-II at the Large Hadron Collider </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=J.%20C.%20Cabanillas-Noris">J. C. Cabanillas-Noris</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20I.%20Mart%C3%ADnez-Hern%C3%A1ndez"> M. I. Martínez-Hernández</a>, <a href="https://publications.waset.org/abstracts/search?q=I.%20Le%C3%B3n-Monz%C3%B3n"> I. León-Monzón</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The selection of diffractive events in the ALICE experiment during the first data taking period (RUN-I) of the Large Hadron Collider (LHC) was limited by the range over which rapidity gaps occur. It would be possible to achieve better measurements by expanding the range in which the production of particles can be detected. For this purpose, the ALICE Diffractive (AD0) detector has been installed and commissioned for the second phase (RUN-II). Any new detector should be able to take the data synchronously with all other detectors and be operated through the ALICE central systems. One of the key elements that must be developed for the AD0 detector is the Detector Control System (DCS). The DCS must be designed to operate safely and correctly this detector. Furthermore, the DCS must also provide optimum operating conditions for the acquisition and storage of physics data and ensure these are of the highest quality. The operation of AD0 implies the configuration of about 200 parameters, from electronics settings and power supply levels to the archiving of operating conditions data and the generation of safety alerts. It also includes the automation of procedures to get the AD0 detector ready for taking data in the appropriate conditions for the different run types in ALICE. The performance of AD0 detector depends on a certain number of parameters such as the nominal voltages for each photomultiplier tube (PMT), their threshold levels to accept or reject the incoming pulses, the definition of triggers, etc. All these parameters define the efficiency of AD0 and they have to be monitored and controlled through AD0 DCS. Finally, AD0 DCS provides the operator with multiple interfaces to execute these tasks. They are realized as operating panels and scripts running in the background. These features are implemented on a SCADA software platform as a distributed control system which integrates to the global control system of the ALICE experiment. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=AD0" title="AD0">AD0</a>, <a href="https://publications.waset.org/abstracts/search?q=ALICE" title=" ALICE"> ALICE</a>, <a href="https://publications.waset.org/abstracts/search?q=DCS" title=" DCS"> DCS</a>, <a href="https://publications.waset.org/abstracts/search?q=LHC" title=" LHC"> LHC</a> </p> <a href="https://publications.waset.org/abstracts/41006/a-large-ion-collider-experiment-alice-diffractive-detector-control-system-for-run-ii-at-the-large-hadron-collider" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/41006.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">306</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">386</span> Numerical Response of Planar HPGe Detector for 241Am Contamination of Various Shapes</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Manohari">M. Manohari</a>, <a href="https://publications.waset.org/abstracts/search?q=Himanshu%20Gupta"> Himanshu Gupta</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20Priyadharshini"> S. Priyadharshini</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20Santhanam"> R. Santhanam</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20Chandrasekaran"> S. Chandrasekaran</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Venkatraman"> B. Venkatraman</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Injection is one of the potential routes of intake in a radioactive facility. The internal dose due to this intake is monitored at the radiation emergency medical centre, IGCAR using a portable planar HPGe detector. The contaminated wound may be having different shapes. In a reprocessing potential of wound contamination with actinide is more. Efficiency is one of the input parameters for estimation of internal dose. Estimating these efficiencies experimentally would be tedious and cumbersome. Numerical estimation can be a supplement to experiment. As an initial step in this study 241Am contamination of different shapes are studied. In this study portable planar HPGe detector was modeled using Monte Carlo code FLUKA and the effect of different parameters like distance of the contamination from the detector, radius of the circular contamination were studied. Efficiency values for point and surface contamination located at different distances were estimated. The effect of efficiency on the radius of the surface source was more predominant when the source is at 1 cm distance compared to when the source to detector distance is 10 cm. At 1 cm the efficiency decreased quadratically as the radius increased and at 10 cm it decreased linearly. The point source efficiency varied exponentially with source to detector distance. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Planar%20HPGe" title="Planar HPGe">Planar HPGe</a>, <a href="https://publications.waset.org/abstracts/search?q=efficiency%20value" title=" efficiency value"> efficiency value</a>, <a href="https://publications.waset.org/abstracts/search?q=injection" title=" injection"> injection</a>, <a href="https://publications.waset.org/abstracts/search?q=surface%20source" title=" surface source"> surface source</a> </p> <a href="https://publications.waset.org/abstracts/185308/numerical-response-of-planar-hpge-detector-for-241am-contamination-of-various-shapes" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/185308.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">42</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">385</span> Design, Construction and Performance Evaluation of a HPGe Detector Shield</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Sharifi">M. Sharifi</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Mirzaii"> M. Mirzaii</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20Bolourinovin"> F. Bolourinovin</a>, <a href="https://publications.waset.org/abstracts/search?q=H.%20Yousefnia"> H. Yousefnia</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Akbari"> M. Akbari</a>, <a href="https://publications.waset.org/abstracts/search?q=K.%20Yousefi-Mojir"> K. Yousefi-Mojir</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A multilayer passive shield composed of low-activity lead (Pb), copper (Cu), tin (Sn) and iron (Fe) was designed and manufactured for a coaxial HPGe detector placed at a surface laboratory for reducing background radiation and radiation dose to the personnel. The performance of the shield was evaluated and efficiency curves of the detector were plotted by using of the various standard sources in different distances. Monte Carlo simulations and a set of TLD chips were used for dose estimation in two distances of 20 and 40 cm. The results show that the shield reduced background spectrum and the personnel dose more than 95%. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=HPGe%20shield" title="HPGe shield">HPGe shield</a>, <a href="https://publications.waset.org/abstracts/search?q=background%20count" title=" background count"> background count</a>, <a href="https://publications.waset.org/abstracts/search?q=personnel%20dose" title=" personnel dose"> personnel dose</a>, <a href="https://publications.waset.org/abstracts/search?q=efficiency%20curve" title=" efficiency curve"> efficiency curve</a> </p> <a href="https://publications.waset.org/abstracts/34295/design-construction-and-performance-evaluation-of-a-hpge-detector-shield" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/34295.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">456</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">384</span> Design of a Portable Shielding System for a Newly Installed NaI(Tl) Detector</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mayesha%20Tahsin">Mayesha Tahsin</a>, <a href="https://publications.waset.org/abstracts/search?q=A.S.%20Mollah"> A.S. Mollah</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Recently, a 1.5x1.5 inch NaI(Tl) detector based gamma-ray spectroscopy system has been installed in the laboratory of the Nuclear Science and Engineering Department of the Military Institute of Science and Technology for radioactivity detection purposes. The newly installed NaI(Tl) detector has a circular lead shield of 22 mm width. An important consideration of any gamma-ray spectroscopy is the minimization of natural background radiation not originating from the radioactive sample that is being measured. Natural background gamma-ray radiation comes from naturally occurring or man-made radionuclides in the environment or from cosmic sources. Moreover, the main problem with this system is that it is not suitable for measurements of radioactivity with a large sample container like Petridish or Marinelli beaker geometry. When any laboratory installs a new detector or/and new shield, it “must” first carry out quality and performance tests for the detector and shield. This paper describes a new portable shielding system with lead that can reduce the background radiation. Intensity of gamma radiation after passing the shielding will be calculated using shielding equation I=Ioe-µx where Io is initial intensity of the gamma source, I is intensity after passing through the shield, µ is linear attenuation coefficient of the shielding material, and x is the thickness of the shielding material. The height and width of the shielding will be selected in order to accommodate the large sample container. The detector will be surrounded by a 4π-geometry low activity lead shield. An additional 1.5 mm thick shield of tin and 1 mm thick shield of copper covering the inner part of the lead shielding will be added in order to remove the presence of characteristic X-rays from the lead shield. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=shield" title="shield">shield</a>, <a href="https://publications.waset.org/abstracts/search?q=NaI%20%28Tl%29%20detector" title=" NaI (Tl) detector"> NaI (Tl) detector</a>, <a href="https://publications.waset.org/abstracts/search?q=gamma%20radiation" title=" gamma radiation"> gamma radiation</a>, <a href="https://publications.waset.org/abstracts/search?q=intensity" title=" intensity"> intensity</a>, <a href="https://publications.waset.org/abstracts/search?q=linear%20attenuation%20coefficient" title=" linear attenuation coefficient"> linear attenuation coefficient</a> </p> <a href="https://publications.waset.org/abstracts/146333/design-of-a-portable-shielding-system-for-a-newly-installed-naitl-detector" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/146333.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">158</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">383</span> The MoEDAL-MAPP* Experiment - Expanding the Discovery Horizon of the Large Hadron Collider</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=James%20Pinfold">James Pinfold</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The MoEDAL (Monopole and Exotics Detector at the LHC) experiment deployed at IP8 on the Large Hadron Collider ring was the first dedicated search experiment to take data at the Large Hadron Collider (LHC) in 2010. It was designed to search for Highly Ionizing Particle (HIP) avatars of new physics such as magnetic monopoles, dyons, Q-balls, multiply charged particles, massive, slowly moving charged particles and long-lived massive charge SUSY particles. We shall report on our search at LHC’s Run-2 for Magnetic monopoles and dyons produced in p-p and photon-fusion. In more detail, we will report our most recent result in this arena: the search for magnetic monopoles via the Schwinger Mechanism in Pb-Pb collisions. The MoEDAL detector, originally the first dedicated search detector at the LHC, is being reinstalled for LHC’s Run-3 to continue the search for electrically and magnetically charged HIPs with enhanced instantaneous luminosity, detector efficiency and a factor of ten lower thresholds for HIPs. As part of this effort, we will search for massive l long-lived, singly and multiply charged particles from various scenarios for which MoEDAL has a competitive sensitivity. An upgrade to MoEDAL, the MoEDAL Apparatus for Penetrating Particles (MAPP), is now the LHC’s newest detector. The MAPP detector, positioned in UA83, expands the physics reach of MoEDAL to include sensitivity to feebly-charged particles with charge, or effective charge, as low as 10-3 e (where e is the electron charge). Also, In conjunction with MoEDAL’s trapping detector, the MAPP detector gives us a unique sensitivity to extremely long-lived charged particles. MAPP also has some sensitivity to long-lived neutral particles. The addition of an Outrigger detector for MAPP-1 to increase its acceptance for more massive milli-charged particles is currently in the Technical Proposal stage. Additionally, we will briefly report on the plans for the MAPP-2 upgrade to the MoEDAL-MAPP experiment for the High Luminosity LHC (HL-LHC). This experiment phase is designed to maximize MoEDAL-MAPP’s sensitivity to very long-lived neutral messengers of physics beyond the Standard Model. We envisage this detector being deployed in the UGC1 gallery near IP8. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=LHC" title="LHC">LHC</a>, <a href="https://publications.waset.org/abstracts/search?q=beyond%20the%20standard%20model" title=" beyond the standard model"> beyond the standard model</a>, <a href="https://publications.waset.org/abstracts/search?q=dedicated%20search%20experiment" title=" dedicated search experiment"> dedicated search experiment</a>, <a href="https://publications.waset.org/abstracts/search?q=highly%20ionizing%20particles" title=" highly ionizing particles"> highly ionizing particles</a>, <a href="https://publications.waset.org/abstracts/search?q=long-lived%20particles" title=" long-lived particles"> long-lived particles</a>, <a href="https://publications.waset.org/abstracts/search?q=milli-charged%20particles" title=" milli-charged particles"> milli-charged particles</a> </p> <a href="https://publications.waset.org/abstracts/167524/the-moedal-mapp-experiment-expanding-the-discovery-horizon-of-the-large-hadron-collider" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/167524.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">68</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">382</span> Consideration of Failed Fuel Detector Location through Computational Flow Dynamics Analysis on Primary Cooling System Flow with Two Outlets</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sanghoon%20Bae">Sanghoon Bae</a>, <a href="https://publications.waset.org/abstracts/search?q=Hanju%20Cha"> Hanju Cha</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Failed fuel detector (FFD) in research reactor is a very crucial instrument to detect the anomaly from failed fuels in the early stage around primary cooling system (PCS) outlet prior to the decay tank. FFD is considered as a mandatory sensor to ensure the integrity of fuel assemblies and mitigate the consequence from a failed fuel accident. For the effective function of FFD, the location of them should be determined by contemplating the effect from coolant flow around two outlets. For this, the analysis on computational flow dynamics (CFD) should be first performed how the coolant outlet flow including radioactive materials from failed fuels are mixed and discharged through the outlet plenum within certain seconds. The analysis result shows that the outlet flow is well mixed regardless of the position of failed fuel and ultimately illustrates the effect of detector location. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=computational%20flow%20dynamics%20%28CFD%29" title="computational flow dynamics (CFD)">computational flow dynamics (CFD)</a>, <a href="https://publications.waset.org/abstracts/search?q=failed%20fuel%20detector%20%28FFD%29" title=" failed fuel detector (FFD)"> failed fuel detector (FFD)</a>, <a href="https://publications.waset.org/abstracts/search?q=fresh%20fuel%20assembly%20%28FFA%29" title=" fresh fuel assembly (FFA)"> fresh fuel assembly (FFA)</a>, <a href="https://publications.waset.org/abstracts/search?q=spent%20fuel%20assembly%20%28SFA%29" title=" spent fuel assembly (SFA)"> spent fuel assembly (SFA)</a> </p> <a href="https://publications.waset.org/abstracts/73722/consideration-of-failed-fuel-detector-location-through-computational-flow-dynamics-analysis-on-primary-cooling-system-flow-with-two-outlets" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/73722.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">240</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">381</span> Reliability of Swine Estrous Detector Probe in Dairy Cattle Breeding</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=O.%20O.%20Leigh">O. O. Leigh</a>, <a href="https://publications.waset.org/abstracts/search?q=L.%20C.%20Agbugba"> L. C. Agbugba</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20O.%20Oyewunmi"> A. O. Oyewunmi</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20E.%20Ibiam"> A. E. Ibiam</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Hassan"> A. Hassan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Accuracy of insemination timing is a key determinant of high pregnancy rates in livestock breeding stations. The estrous detector probes are a recent introduction into the Nigerian livestock farming sector. Many of these probes are species-labeled and they measure changes in the vaginal mucus resistivity (VMR) during the stages of the estrous cycle. With respect to size and shaft conformation, the Draminski® swine estrous detector probe (sEDP) is quite similar to the bovine estrous detector probe. We investigated the reliability of the sEDP at insemination time on two farms designated as FM A and FM B. Cows (Bunaji, n=20 per farm) were evaluated for VMR at 16th h post standard OvSynch protocol, with concurrent insemination on FM B only. The difference in the mean VMR between FM A (221 ± 24.36) Ohms and FM B (254 ± 35.59) Ohms was not significant (p > 0.05). Sixteen cows (80%) at FM B were later (day 70) confirmed pregnant via rectal palpation and calved at term. These findings suggest consistency in VMR evaluated with sEDP at insemination as well as a high predictability for VMR associated with good pregnancy rates in dairy cattle. We conclude that Draminski® swine estrous detector probe is reliable in determining time of insemination in cattle breeding stations. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=dairy%20cattle" title="dairy cattle">dairy cattle</a>, <a href="https://publications.waset.org/abstracts/search?q=insemination" title=" insemination"> insemination</a>, <a href="https://publications.waset.org/abstracts/search?q=swine%20estrous%20probe" title=" swine estrous probe"> swine estrous probe</a>, <a href="https://publications.waset.org/abstracts/search?q=vaginal%20mucus%20resistivity" title=" vaginal mucus resistivity"> vaginal mucus resistivity</a> </p> <a href="https://publications.waset.org/abstracts/108250/reliability-of-swine-estrous-detector-probe-in-dairy-cattle-breeding" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/108250.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">124</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">380</span> Research on Development and Accuracy Improvement of an Explosion Proof Combustible Gas Leak Detector Using an IR Sensor</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Gyoutae%20Park">Gyoutae Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Seungho%20Han"> Seungho Han</a>, <a href="https://publications.waset.org/abstracts/search?q=Byungduk%20Kim"> Byungduk Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Youngdo%20Jo"> Youngdo Jo</a>, <a href="https://publications.waset.org/abstracts/search?q=Yongsop%20Shim"> Yongsop Shim</a>, <a href="https://publications.waset.org/abstracts/search?q=Yeonjae%20Lee"> Yeonjae Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Sangguk%20Ahn"> Sangguk Ahn</a>, <a href="https://publications.waset.org/abstracts/search?q=Hiesik%20Kim"> Hiesik Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Jungil%20Park"> Jungil Park </a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, we presented not only development technology of an explosion proof type and portable combustible gas leak detector but also algorithm to improve accuracy for measuring gas concentrations. The presented techniques are to apply the flame-proof enclosure and intrinsic safe explosion proof to an infrared gas leak detector at first in Korea and to improve accuracy using linearization recursion equation and Lagrange interpolation polynomial. Together, we tested sensor characteristics and calibrated suitable input gases and output voltages. Then, we advanced the performances of combustible gaseous detectors through reflecting demands of gas safety management fields. To check performances of two company&#39;s detectors, we achieved the measurement tests with eight standard gases made by Korea Gas Safety Corporation. We demonstrated our instruments better in detecting accuracy other than detectors through experimental results. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=accuracy%20improvement" title="accuracy improvement">accuracy improvement</a>, <a href="https://publications.waset.org/abstracts/search?q=IR%20gas%20sensor" title=" IR gas sensor"> IR gas sensor</a>, <a href="https://publications.waset.org/abstracts/search?q=gas%20leak" title=" gas leak"> gas leak</a>, <a href="https://publications.waset.org/abstracts/search?q=detector" title=" detector"> detector</a> </p> <a href="https://publications.waset.org/abstracts/47808/research-on-development-and-accuracy-improvement-of-an-explosion-proof-combustible-gas-leak-detector-using-an-ir-sensor" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/47808.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">391</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">379</span> Reliability Factors Based Fuzzy Logic Scheme for Spectrum Sensing</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Tallataf%20Rasheed">Tallataf Rasheed</a>, <a href="https://publications.waset.org/abstracts/search?q=Adnan%20Rashdi"> Adnan Rashdi</a>, <a href="https://publications.waset.org/abstracts/search?q=Ahmad%20Naeem%20Akhtar"> Ahmad Naeem Akhtar</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The accurate spectrum sensing is a fundamental requirement of dynamic spectrum access for deployment of Cognitive Radio Network (CRN). To acheive this requirement a Reliability factors based Fuzzy Logic (RFL) Scheme for Spectrum Sensing has been proposed in this paper. Cognitive Radio User (CRU) predicts the presence or absence of Primary User (PU) using energy detector and calculates the Reliability factors which are SNR of sensing node, threshold of energy detector and decision difference of each node with other nodes in a cooperative spectrum sensing environment. Then the decision of energy detector is combined with Reliability factors of sensing node using Fuzzy Logic. These Reliability Factors used in RFL Scheme describes the reliability of decision made by a CRU to improve the local spectrum sensing. This Fuzzy combining scheme provides the accuracy of decision made by sensornode. The simulation results have shown that the proposed technique provide better PU detection probability than existing Spectrum Sensing Techniques. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cognitive%20radio" title="cognitive radio">cognitive radio</a>, <a href="https://publications.waset.org/abstracts/search?q=spectrum%20sensing" title=" spectrum sensing"> spectrum sensing</a>, <a href="https://publications.waset.org/abstracts/search?q=energy%20detector" title=" energy detector"> energy detector</a>, <a href="https://publications.waset.org/abstracts/search?q=reliability%20factors" title=" reliability factors"> reliability factors</a>, <a href="https://publications.waset.org/abstracts/search?q=fuzzy%20logic" title=" fuzzy logic"> fuzzy logic</a> </p> <a href="https://publications.waset.org/abstracts/77586/reliability-factors-based-fuzzy-logic-scheme-for-spectrum-sensing" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/77586.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">486</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">378</span> Study on Beta-Ray Detection System in Water Using a MCNP Simulation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ki%20Hyun%20Park">Ki Hyun Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Hye%20Min%20Park"> Hye Min Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Jeong%20Ho%20Kim"> Jeong Ho Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Chan%20Jong%20Park"> Chan Jong Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Koan%20Sik%20Joo"> Koan Sik Joo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In the modern days, the use of radioactive substances is on the rise in the areas like chemical weaponry, industrial usage, and power plants. Although there are various technologies available to detect and monitor radioactive substances in the air, the technologies to detect underwater radioactive substances are scarce. In this study, computer simulation of the underwater detection system measuring beta-ray, a radioactive substance, has been done through MCNP. CaF₂, YAP(Ce) and YAG(Ce) have been used in the computer simulation to detect beta-ray as scintillator. Also, the source used in the computer simulation is Sr-90 and Y-90, both of them emitting only pure beta-ray. The distance between the source and the detector was shifted from 1mm to 10mm by 1 mm in the computer simulation. The result indicated that Sr-90 was impossible to measure below 1 mm since its emission energy is low while Y-90 was able to be measured up to 10mm underwater. In addition, the detector designed with CaF₂ had the highest efficiency among 3 scintillators used in the computer simulation. Since it was possible to verify the detectable range and the detection efficiency according to modeling through MCNP simulation, it is expected that such result will reduce the time and cost in building the actual beta-ray detector and evaluating its performances, thereby contributing the research and development. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Beta-ray" title="Beta-ray">Beta-ray</a>, <a href="https://publications.waset.org/abstracts/search?q=CaF%E2%82%82" title=" CaF₂"> CaF₂</a>, <a href="https://publications.waset.org/abstracts/search?q=detector" title=" detector"> detector</a>, <a href="https://publications.waset.org/abstracts/search?q=MCNP%20simulation" title=" MCNP simulation"> MCNP simulation</a>, <a href="https://publications.waset.org/abstracts/search?q=scintillator" title=" scintillator"> scintillator</a> </p> <a href="https://publications.waset.org/abstracts/53352/study-on-beta-ray-detection-system-in-water-using-a-mcnp-simulation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/53352.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">510</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">377</span> An Adaptive CFAR Algorithm Based on Automatic Censoring in Heterogeneous Environments</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Naime%20Boudemagh">Naime Boudemagh</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this work, we aim to improve the detection performances of radar systems. To this end, we propose and analyze a novel censoring technique of undesirable samples, of priori unknown positions, that may be present in the environment under investigation. Therefore, we consider heterogeneous backgrounds characterized by the presence of some irregularities such that clutter edge transitions and/or interfering targets. The proposed detector, termed automatic censoring constant false alarm (AC-CFAR), operates exclusively in a Gaussian background. It is built to allow the segmentation of the environment to regions and switch automatically to the appropriate detector; namely, the cell averaging CFAR (CA-CFAR), the censored mean level CFAR (CMLD-CFAR) or the order statistic CFAR (OS-CFAR). Monte Carlo simulations show that the AC-CFAR detector performs like the CA-CFAR in a homogeneous background. Moreover, the proposed processor exhibits considerable robustness in a heterogeneous background. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=CFAR" title="CFAR">CFAR</a>, <a href="https://publications.waset.org/abstracts/search?q=automatic%20censoring" title=" automatic censoring"> automatic censoring</a>, <a href="https://publications.waset.org/abstracts/search?q=heterogeneous%20environments" title=" heterogeneous environments"> heterogeneous environments</a>, <a href="https://publications.waset.org/abstracts/search?q=radar%20systems" title=" radar systems"> radar systems</a> </p> <a href="https://publications.waset.org/abstracts/28302/an-adaptive-cfar-algorithm-based-on-automatic-censoring-in-heterogeneous-environments" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/28302.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">602</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">376</span> Epileptic Seizure Onset Detection via Energy and Neural Synchronization Decision Fusion</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Marwa%20Qaraqe">Marwa Qaraqe</a>, <a href="https://publications.waset.org/abstracts/search?q=Muhammad%20Ismail"> Muhammad Ismail</a>, <a href="https://publications.waset.org/abstracts/search?q=Erchin%20Serpedin"> Erchin Serpedin</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents a novel architecture for a patient-specific epileptic seizure onset detector using scalp electroencephalography (EEG). The proposed architecture is based on the decision fusion calculated from energy and neural synchronization related features. Specifically, one level of the detector calculates the condition number (CN) of an EEG matrix to evaluate the amount of neural synchronization present within the EEG channels. On a parallel level, the detector evaluates the energy contained in four EEG frequency subbands. The information is then fed into two independent (parallel) classification units based on support vector machines to determine the onset of a seizure event. The decisions from the two classifiers are then combined together according to two fusion techniques to determine a global decision. Experimental results demonstrate that the detector based on the AND fusion technique outperforms existing detectors with a sensitivity of 100%, detection latency of 3 seconds, while it achieves a 2:76 false alarm rate per hour. The OR fusion technique achieves a sensitivity of 100%, and significantly improves delay latency (0:17 seconds), yet it achieves 12 false alarms per hour. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=epilepsy" title="epilepsy">epilepsy</a>, <a href="https://publications.waset.org/abstracts/search?q=EEG" title=" EEG"> EEG</a>, <a href="https://publications.waset.org/abstracts/search?q=seizure%20onset" title=" seizure onset"> seizure onset</a>, <a href="https://publications.waset.org/abstracts/search?q=electroencephalography" title=" electroencephalography"> electroencephalography</a>, <a href="https://publications.waset.org/abstracts/search?q=neuron" title=" neuron"> neuron</a>, <a href="https://publications.waset.org/abstracts/search?q=detection" title=" detection"> detection</a> </p> <a href="https://publications.waset.org/abstracts/24040/epileptic-seizure-onset-detection-via-energy-and-neural-synchronization-decision-fusion" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/24040.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">477</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">375</span> Developing Laser Spot Position Determination and PRF Code Detection with Quadrant Detector</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20Fathy%20Heweage">Mohamed Fathy Heweage</a>, <a href="https://publications.waset.org/abstracts/search?q=Xiao%20Wen"> Xiao Wen</a>, <a href="https://publications.waset.org/abstracts/search?q=Ayman%20Mokhtar"> Ayman Mokhtar</a>, <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20Eldamarawy"> Ahmed Eldamarawy</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, we are interested in modeling, simulation, and measurement of the laser spot position with a quadrant detector. We enhance detection and tracking of semi-laser weapon decoding system based on microcontroller. The system receives the reflected pulse through quadrant detector and processes the laser pulses through a processing circuit, a microcontroller decoding laser pulse reflected by the target. The seeker accuracy will be enhanced by the decoding system, the laser detection time based on the receiving pulses number is reduced, a gate is used to limit the laser pulse width. The model is implemented based on Pulse Repetition Frequency (PRF) technique with two microcontroller units (MCU). MCU1 generates laser pulses with different codes. MCU2 decodes the laser code and locks the system at the specific code. The codes EW selected based on the two selector switches. The system is implemented and tested in Proteus ISIS software. The implementation of the full position determination circuit with the detector is produced. General system for the spot position determination was performed with the laser PRF for incident radiation and the mechanical system for adjusting system at different angles. The system test results show that the system can detect the laser code with only three received pulses based on the narrow gate signal, and good agreement between simulation and measured system performance is obtained. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=four%20quadrant%20detector" title="four quadrant detector">four quadrant detector</a>, <a href="https://publications.waset.org/abstracts/search?q=pulse%20code%20detection" title=" pulse code detection"> pulse code detection</a>, <a href="https://publications.waset.org/abstracts/search?q=laser%20guided%20weapons" title=" laser guided weapons"> laser guided weapons</a>, <a href="https://publications.waset.org/abstracts/search?q=pulse%20repetition%20frequency%20%28PRF%29" title=" pulse repetition frequency (PRF)"> pulse repetition frequency (PRF)</a>, <a href="https://publications.waset.org/abstracts/search?q=Atmega%2032%20microcontrollers" title=" Atmega 32 microcontrollers"> Atmega 32 microcontrollers</a> </p> <a href="https://publications.waset.org/abstracts/66984/developing-laser-spot-position-determination-and-prf-code-detection-with-quadrant-detector" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/66984.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">390</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">374</span> Mechanical Study Printed Circuit Boards Bonding for Jefferson Laboratory Detector</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=F.%20Noto">F. Noto</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20De%20Persio"> F. De Persio</a>, <a href="https://publications.waset.org/abstracts/search?q=V.%20Bellini"> V. Bellini</a>, <a href="https://publications.waset.org/abstracts/search?q=G.%20Costa.%20F.%20Mammoliti"> G. Costa. F. Mammoliti</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20Meddi"> F. Meddi</a>, <a href="https://publications.waset.org/abstracts/search?q=C.%20Sutera"> C. Sutera</a>, <a href="https://publications.waset.org/abstracts/search?q=G.%20M.%20Urcioli"> G. M. Urcioli</a> </p> <p class="card-text"><strong>Abstract:</strong></p> One plane X and one plane Y of silicon microstrip detectors will constitute the front part of the Super Bigbite Spectrometer that is under construction and that will be installed in the experimental Hall A of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory), located in Newport News, Virgina, USA. Each plane will be made up by two nearly identical, 300 μm thick, 10 cm x 10.3 cm wide silicon microstrip detectors with 50 um pitch, whose electronic signals will be transferred to the front-end electronic based on APV25 chips through C-shaped FR4 Printed Circuit Boards (PCB). A total of about 10000 strips are read-out. This paper treats the optimization of the detector support structure, the materials used through a finite element simulation. A very important aspect of the study will also cover the optimization of the bonding parameters between detector and electronics. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=FEM%20analysis" title="FEM analysis">FEM analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=bonding" title=" bonding"> bonding</a>, <a href="https://publications.waset.org/abstracts/search?q=SBS%20tracker" title=" SBS tracker"> SBS tracker</a>, <a href="https://publications.waset.org/abstracts/search?q=mechanical%20structure" title=" mechanical structure"> mechanical structure</a> </p> <a href="https://publications.waset.org/abstracts/67695/mechanical-study-printed-circuit-boards-bonding-for-jefferson-laboratory-detector" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/67695.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">339</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">373</span> A Development of Portable Intrinsically Safe Explosion-Proof Type of Dual Gas Detector</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sangguk%20Ahn">Sangguk Ahn</a>, <a href="https://publications.waset.org/abstracts/search?q=Youngyu%20Kim"> Youngyu Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Jaheon%20Gu"> Jaheon Gu</a>, <a href="https://publications.waset.org/abstracts/search?q=Gyoutae%20Park"> Gyoutae Park</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, we developed a dual gas leak instrument to detect Hydrocarbon (HC) and Monoxide (CO) gases. To two kinds of gases, it is necessary to design compact structure for sensors. And then it is important to draw sensing circuits such as measuring, amplifying and filtering. After that, it should be well programmed with robust, systematic and module coding methods. In center of them, improvement of accuracy and initial response time are a matter of vital importance. To manufacture distinguished gas leak detector, we applied intrinsically safe explosion-proof structure to lithium ion battery, main circuits, a pump with motor, color LCD interfaces and sensing circuits. On software, to enhance measuring accuracy we used numerical analysis such as Lagrange and Neville interpolation. Performance test result is conducted by using standard Methane with seven different concentrations with three other products. We want raise risk prevention and efficiency of gas safe management through distributing to the field of gas safety. Acknowledgment: This study was supported by Small and Medium Business Administration under the research theme of ‘Commercialized Development of a portable intrinsically safe explosion-proof type dual gas leak detector’, (task number S2456036). <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=gas%20leak" title="gas leak">gas leak</a>, <a href="https://publications.waset.org/abstracts/search?q=dual%20gas%20detector" title=" dual gas detector"> dual gas detector</a>, <a href="https://publications.waset.org/abstracts/search?q=intrinsically%20safe" title=" intrinsically safe"> intrinsically safe</a>, <a href="https://publications.waset.org/abstracts/search?q=explosion%20proof" title=" explosion proof"> explosion proof</a> </p> <a href="https://publications.waset.org/abstracts/69836/a-development-of-portable-intrinsically-safe-explosion-proof-type-of-dual-gas-detector" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/69836.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">228</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">372</span> Development of Nondestructive Imaging Analysis Method Using Muonic X-Ray with a Double-Sided Silicon Strip Detector</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=I-Huan%20Chiu">I-Huan Chiu</a>, <a href="https://publications.waset.org/abstracts/search?q=Kazuhiko%20Ninomiya"> Kazuhiko Ninomiya</a>, <a href="https://publications.waset.org/abstracts/search?q=Shin%E2%80%99ichiro%20Takeda"> Shin’ichiro Takeda</a>, <a href="https://publications.waset.org/abstracts/search?q=Meito%20Kajino"> Meito Kajino</a>, <a href="https://publications.waset.org/abstracts/search?q=Miho%20Katsuragawa"> Miho Katsuragawa</a>, <a href="https://publications.waset.org/abstracts/search?q=Shunsaku%20Nagasawa"> Shunsaku Nagasawa</a>, <a href="https://publications.waset.org/abstracts/search?q=Atsushi%20Shinohara"> Atsushi Shinohara</a>, <a href="https://publications.waset.org/abstracts/search?q=Tadayuki%20Takahashi"> Tadayuki Takahashi</a>, <a href="https://publications.waset.org/abstracts/search?q=Ryota%20Tomaru"> Ryota Tomaru</a>, <a href="https://publications.waset.org/abstracts/search?q=Shin%20Watanabe"> Shin Watanabe</a>, <a href="https://publications.waset.org/abstracts/search?q=Goro%20Yabu"> Goro Yabu</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In recent years, a nondestructive elemental analysis method based on muonic X-ray measurements has been developed and applied for various samples. Muonic X-rays are emitted after the formation of a muonic atom, which occurs when a negatively charged muon is captured in a muon atomic orbit around the nucleus. Because muonic X-rays have higher energy than electronic X-rays due to the muon mass, they can be measured without being absorbed by a material. Thus, estimating the two-dimensional (2D) elemental distribution of a sample became possible using an X-ray imaging detector. In this work, we report a non-destructive imaging experiment using muonic X-rays at Japan Proton Accelerator Research Complex. The irradiated target consisted of polypropylene material, and a double-sided silicon strip detector, which was developed as an imaging detector for astronomical observation, was employed. A peak corresponding to muonic X-rays from the carbon atoms in the target was clearly observed in the energy spectrum at an energy of 14 keV, and 2D visualizations were successfully reconstructed to reveal the projection image from the target. This result demonstrates the potential of the non-destructive elemental imaging method that is based on muonic X-ray measurement. To obtain a higher position resolution for imaging a smaller target, a new detector system will be developed to improve the statistical analysis in further research. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=DSSD" title="DSSD">DSSD</a>, <a href="https://publications.waset.org/abstracts/search?q=muon" title=" muon"> muon</a>, <a href="https://publications.waset.org/abstracts/search?q=muonic%20X-ray" title=" muonic X-ray"> muonic X-ray</a>, <a href="https://publications.waset.org/abstracts/search?q=imaging" title=" imaging"> imaging</a>, <a href="https://publications.waset.org/abstracts/search?q=non-destructive%20analysis" title=" non-destructive analysis"> non-destructive analysis</a> </p> <a href="https://publications.waset.org/abstracts/137568/development-of-nondestructive-imaging-analysis-method-using-muonic-x-ray-with-a-double-sided-silicon-strip-detector" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/137568.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">205</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">371</span> Development of a Remote Testing System for Performance of Gas Leakage Detectors</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Gyoutae%20Park">Gyoutae Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Woosuk%20Kim"> Woosuk Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Sangguk%20Ahn"> Sangguk Ahn</a>, <a href="https://publications.waset.org/abstracts/search?q=Seungmo%20Kim"> Seungmo Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Minjun%20Kim"> Minjun Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Jinhan%20Lee"> Jinhan Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Youngdo%20Jo"> Youngdo Jo</a>, <a href="https://publications.waset.org/abstracts/search?q=Jongsam%20Moon"> Jongsam Moon</a>, <a href="https://publications.waset.org/abstracts/search?q=Hiesik%20Kim"> Hiesik Kim</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this research, we designed a remote system to test parameters of gas detectors such as gas concentration and initial response time. This testing system is available to measure two gas instruments simultaneously. First of all, we assembled an experimental jig with a square structure. Those parts are included with a glass flask, two high-quality cameras, and two Ethernet modems for transmitting data. This remote gas detector testing system extracts numerals from videos with continually various gas concentrations while LCDs show photographs from cameras. Extracted numeral data are received to a laptop computer through Ethernet modem. And then, the numerical data with gas concentrations and the measured initial response speeds are recorded and graphed. Our remote testing system will be diversely applied on gas detector&rsquo;s test and will be certificated in domestic and international countries. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=gas%20leak%20detector" title="gas leak detector">gas leak detector</a>, <a href="https://publications.waset.org/abstracts/search?q=inspection%20instrument" title=" inspection instrument"> inspection instrument</a>, <a href="https://publications.waset.org/abstracts/search?q=extracting%20numerals" title=" extracting numerals"> extracting numerals</a>, <a href="https://publications.waset.org/abstracts/search?q=concentration" title=" concentration"> concentration</a> </p> <a href="https://publications.waset.org/abstracts/65616/development-of-a-remote-testing-system-for-performance-of-gas-leakage-detectors" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/65616.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">374</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">370</span> Study of a Few Additional Posterior Projection Data to 180° Acquisition for Myocardial SPECT</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Yasuyuki%20Takahashi">Yasuyuki Takahashi</a>, <a href="https://publications.waset.org/abstracts/search?q=Hirotaka%20Shimada"> Hirotaka Shimada</a>, <a href="https://publications.waset.org/abstracts/search?q=Takao%20Kanzaki"> Takao Kanzaki</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A Dual-detector SPECT system is widely by use of myocardial SPECT studies. With 180-degree (180°) acquisition, reconstructed images are distorted in the posterior wall of myocardium due to the lack of sufficient data of posterior projection. We hypothesized that quality of myocardial SPECT images can be improved by the addition of data acquisition of only a few posterior projections to ordinary 180° acquisition. The proposed acquisition method (180° plus acquisition methods) uses the dual-detector SPECT system with a pair of detector arranged in 90° perpendicular. Sampling angle was 5°, and the acquisition range was 180° from 45° right anterior oblique to 45° left posterior oblique. After the acquisition of 180°, the detector moved to additional acquisition position of reverse side once for 2 projections, twice for 4 projections, or 3 times for 6 projections. Since these acquisition methods cannot be done in the present system, actual data acquisition was done by 360° with a sampling angle of 5°, and projection data corresponding to above acquisition position were extracted for reconstruction. We underwent the phantom studies and a clinical study. SPECT images were compared by profile curve analysis and also quantitatively by contrast ratio. The distortion was improved by 180° plus method. Profile curve analysis showed increased of cardiac cavity. Analysis with contrast ratio revealed that SPECT images of the phantoms and the clinical study were improved from 180° acquisition by the present methods. The difference in the contrast was not clearly recognized between 180° plus 2 projections, 180° plus 4 projections, and 180° plus 6 projections. 180° plus 2 projections method may be feasible for myocardial SPECT because distortion of the image and the contrast were improved. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=180%C2%B0%20plus%20acquisition%20method" title="180° plus acquisition method">180° plus acquisition method</a>, <a href="https://publications.waset.org/abstracts/search?q=a%20few%20posterior%20projections" title=" a few posterior projections"> a few posterior projections</a>, <a href="https://publications.waset.org/abstracts/search?q=dual-detector%20SPECT%20system" title=" dual-detector SPECT system"> dual-detector SPECT system</a>, <a href="https://publications.waset.org/abstracts/search?q=myocardial%20SPECT" title=" myocardial SPECT"> myocardial SPECT</a> </p> <a href="https://publications.waset.org/abstracts/32339/study-of-a-few-additional-posterior-projection-data-to-180-acquisition-for-myocardial-spect" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/32339.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">295</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">369</span> A DNA-Based Nano-biosensor for the Rapid Detection of the Dengue Virus in Mosquito </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Lilia%20M.%20Fernando">Lilia M. Fernando</a>, <a href="https://publications.waset.org/abstracts/search?q=Matthew%20K.%20Vasher"> Matthew K. Vasher</a>, <a href="https://publications.waset.org/abstracts/search?q=Evangelyn%20C.%20Alocilja"> Evangelyn C. Alocilja</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper describes the development of a DNA-based nanobiosensor to detect the dengue virus in mosquito using electrically active magnetic (EAM) nanoparticles as the concentrator and electrochemical transducer. The biosensor detection encompasses two sets of oligonucleotide probes that are specific to the dengue virus: the detector probe labeled with the EAM nanoparticles and the biotinylated capture probe. The DNA targets are double hybridized to the detector and the capture probes and concentrated from nonspecific DNA fragments by applying a magnetic field. Subsequently, the DNA sandwiched targets (EAM-detector probe–DNA target–capture probe-biotin) are captured on streptavidin modified screen printed carbon electrodes through the biotinylated capture probes. Detection is achieved electrochemically by measuring the oxidation–reduction signal of the EAM nanoparticles. Results indicate that the biosensor is able to detect the redox signal of the EAM nanoparticles at dengue DNA concentrations as low as 10 ng/ul. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=dengue" title="dengue">dengue</a>, <a href="https://publications.waset.org/abstracts/search?q=magnetic%20nanoparticles" title=" magnetic nanoparticles"> magnetic nanoparticles</a>, <a href="https://publications.waset.org/abstracts/search?q=mosquito" title=" mosquito"> mosquito</a>, <a href="https://publications.waset.org/abstracts/search?q=nanobiosensor" title=" nanobiosensor"> nanobiosensor</a> </p> <a href="https://publications.waset.org/abstracts/37690/a-dna-based-nano-biosensor-for-the-rapid-detection-of-the-dengue-virus-in-mosquito" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/37690.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">366</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">&lsaquo;</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=13">13</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=14">14</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=CR-39%20detector&amp;page=2" rel="next">&rsaquo;</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">&copy; 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">&times;</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>

Pages: 1 2 3 4 5 6 7 8 9 10