CINXE.COM

Search results for: 3D treatment planning

<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: 3D treatment planning</title> <meta name="description" content="Search results for: 3D treatment planning"> <meta name="keywords" content="3D treatment planning"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="3D treatment planning" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="3D treatment planning"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 11431</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: 3D treatment planning</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11431</span> Rationality and Evidence of Pre-Prepared Treatment Plan in Oesophageal HDR Brachytherapy</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jim%20S.%20Meng">Jim S. Meng</a>, <a href="https://publications.waset.org/abstracts/search?q=Mammo%20H.%20Yewondwossen"> Mammo H. Yewondwossen</a> </p> <p class="card-text"><strong>Abstract:</strong></p> As a part of routine oesophageal HDR brachytherapy procedure, treatment planning takes about 45 minutes while patients are under light sedation. Some patients may suffer gagging and/or spasms, and the treatment may need to be aborted. A pre-prepared plan generated before the patient’s sedation may reduce the brachytherapy procedure time by forty minutes. This paper reports the rationality and evidence of pre-prepared treatment plans. A retrospective study of 28 patients confirm that all of the pre-prepared plans would be acceptable. The rationality of pre-prepared HDR brachytherapy plans is further confirmed by a systemic study with a wide range of applicator curvature and treatment volume. Detailed comparison between CT based treatment plans and pre-prepared plans are discussed. This argument holds also for endobronchial HDR brachytherapy. With the above evidence, pre-prepared plans have been used for all oesophagus and bronchus HDR brachytherapy cases in our clinic. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=HDR%20brachytherapy" title="HDR brachytherapy">HDR brachytherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=treatment%20planning" title=" treatment planning"> treatment planning</a>, <a href="https://publications.waset.org/abstracts/search?q=oesophageal%20carcinoma" title=" oesophageal carcinoma"> oesophageal carcinoma</a>, <a href="https://publications.waset.org/abstracts/search?q=pre-planning" title=" pre-planning "> pre-planning </a> </p> <a href="https://publications.waset.org/abstracts/2471/rationality-and-evidence-of-pre-prepared-treatment-plan-in-oesophageal-hdr-brachytherapy" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/2471.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">395</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11430</span> Using Digitally Reconstructed Radiographs from Magnetic Resonance Images to Localize Pelvic Lymph Nodes on 2D X-Ray Simulator-Based Brachytherapy Treatment Planning</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohammad%20Ali%20Oghabian">Mohammad Ali Oghabian</a>, <a href="https://publications.waset.org/abstracts/search?q=Reza%20Reiazi"> Reza Reiazi</a>, <a href="https://publications.waset.org/abstracts/search?q=Esmaeel%20Parsai"> Esmaeel Parsai</a>, <a href="https://publications.waset.org/abstracts/search?q=Mehdi%20Aghili"> Mehdi Aghili</a>, <a href="https://publications.waset.org/abstracts/search?q=Ramin%20Jaberi"> Ramin Jaberi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this project a new procedure has been introduced for utilizing digitally reconstructed radiograph from MRI images in Brachytherapy treatment planning. This procedure enables us to localize the tumor volume and delineate the extent of critical structures in vicinity of tumor volume. The aim of this project was to improve the accuracy of dose delivered to targets of interest in 2D treatment planning system. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=brachytherapy" title="brachytherapy">brachytherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=cervix" title=" cervix"> cervix</a>, <a href="https://publications.waset.org/abstracts/search?q=digitally%20reconstructed%20radiographs" title=" digitally reconstructed radiographs"> digitally reconstructed radiographs</a>, <a href="https://publications.waset.org/abstracts/search?q=lymph%20node" title=" lymph node"> lymph node</a> </p> <a href="https://publications.waset.org/abstracts/17959/using-digitally-reconstructed-radiographs-from-magnetic-resonance-images-to-localize-pelvic-lymph-nodes-on-2d-x-ray-simulator-based-brachytherapy-treatment-planning" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/17959.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">530</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11429</span> Computation of Radiotherapy Treatment Plans Based on CT to ED Conversion Curves</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=B.%20Petrovi%C4%87">B. Petrović</a>, <a href="https://publications.waset.org/abstracts/search?q=L.%20Rutonjski"> L. Rutonjski</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Baucal"> M. Baucal</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Teodorovi%C4%87"> M. Teodorović</a>, <a href="https://publications.waset.org/abstracts/search?q=O.%20%C4%8Cudi%C4%87"> O. Čudić</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Basari%C4%87"> B. Basarić</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Radiotherapy treatment planning computers use CT data of the patient. For the computation of a treatment plan, treatment planning system must have an information on electron densities of tissues scanned by CT. This information is given by the conversion curve CT (CT number) to ED (electron density), or simply calibration curve. Every treatment planning system (TPS) has built in default CT to ED conversion curves, for the CTs of different manufacturers. However, it is always recommended to verify the CT to ED conversion curve before actual clinical use. Objective of this study was to check how the default curve already provided matches the curve actually measured on a specific CT, and how much it influences the calculation of a treatment planning computer. The examined CT scanners were from the same manufacturer, but four different scanners from three generations. The measurements of all calibration curves were done with the dedicated phantom CIRS 062M Electron Density Phantom. The phantom was scanned, and according to real HU values read at the CT console computer, CT to ED conversion curves were generated for different materials, for same tube voltage 140 kV. Another phantom, CIRS Thorax 002 LFC which represents an average human torso in proportion, density and two-dimensional structure, was used for verification. The treatment planning was done on CT slices of scanned CIRS LFC 002 phantom, for selected cases. Interest points were set in the lungs, and in the spinal cord, and doses recorded in TPS. The overall calculated treatment times for four scanners and default scanner did not differ more than 0.8%. Overall interest point dose in bone differed max 0.6% while for single fields was maximum 2.7% (lateral field). Overall interest point dose in lungs differed max 1.1% while for single fields was maximum 2.6% (lateral field). It is known that user should verify the CT to ED conversion curve, but often, developing countries are facing lack of QA equipment, and often use default data provided. We have concluded that the CT to ED curves obtained differ in certain points of a curve, generally in the region of higher densities. This influences the treatment planning result which is not significant, but definitely does make difference in the calculated dose. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Computation%20of%20treatment%20plan" title="Computation of treatment plan">Computation of treatment plan</a>, <a href="https://publications.waset.org/abstracts/search?q=conversion%20curve" title=" conversion curve"> conversion curve</a>, <a href="https://publications.waset.org/abstracts/search?q=radiotherapy" title=" radiotherapy"> radiotherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=electron%20density" title=" electron density"> electron density</a> </p> <a href="https://publications.waset.org/abstracts/7887/computation-of-radiotherapy-treatment-plans-based-on-ct-to-ed-conversion-curves" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/7887.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">486</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11428</span> Most Important Educational Planning Issues in the Developing Countries </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Naeem%20Khan">Naeem Khan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In 1971 Williams in his essay titled "What Educational Planning is About in Higher Education" defined educational planning as "planning in education, as in anything else consist essentially of deciding, in advance, what you want, to do and how you are going to do in". In the “World Year book of Education”. While Anderson and Bowman in 1976 in their joint article titled "Theoretical Considerations in Educational Planning" defined it as "the process of preparing a set of decisions for future action pertaining in education". There are so many other definitions which are related to educational planning in which every one stress on the importance of educational planning. But developing countries face a lot of problems related to the educational planning and this paper is to discuss few of them. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=educational%20planning" title="educational planning">educational planning</a>, <a href="https://publications.waset.org/abstracts/search?q=problems" title=" problems"> problems</a>, <a href="https://publications.waset.org/abstracts/search?q=developing%20countries" title=" developing countries"> developing countries</a>, <a href="https://publications.waset.org/abstracts/search?q=education%20system" title=" education system"> education system</a>, <a href="https://publications.waset.org/abstracts/search?q=" title=" "> </a> </p> <a href="https://publications.waset.org/abstracts/22287/most-important-educational-planning-issues-in-the-developing-countries" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/22287.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">554</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11427</span> The Epigenetic Background Depended Treatment Planning for Glioblastoma Multiforme</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Rasime%20Kalkan">Rasime Kalkan</a>, <a href="https://publications.waset.org/abstracts/search?q=Emine%20Ikbal%20Atli"> Emine Ikbal Atli</a>, <a href="https://publications.waset.org/abstracts/search?q=Ali%20Arslanta%C5%9F"> Ali Arslantaş</a>, <a href="https://publications.waset.org/abstracts/search?q=Muhsin%20%C3%96zdemir"> Muhsin Özdemir</a>, <a href="https://publications.waset.org/abstracts/search?q=Sevilhan%20Artan"> Sevilhan Artan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Glioblastoma (WHO grade IV), is the malignant form of brain tumor, the genetic background of the GBM is highly variable. The tumor mass of a GBM is multilayered and every tumor layer shows distinct characteristics with a different cell population. The treatment planning of GBM should be focused on the tumor genetic characteristics. We screened primary glioblastoma multiforme (GBM) in a population-based study for MGMT and RARβ methylation and IDH1 mutation correlated them with clinical data and treatment. There was no correlation between MGMT-promoter methylation and overall survival. The overall survival time of the patients with methylated RARβ was statically (OS;p<0,05) significance between the patients who were treated with chemotherapy and radiotherapy. Here we showed the status of IDH1 gene associatied with younger age. We demonstrated that the together with MGMT gene the RARβ gene should be used as a potantial treatment decision marker for GBMs. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=RAR%CE%B2" title="RARβ">RARβ</a>, <a href="https://publications.waset.org/abstracts/search?q=primary%20glioblastoma%20multiforme" title=" primary glioblastoma multiforme"> primary glioblastoma multiforme</a>, <a href="https://publications.waset.org/abstracts/search?q=methylation" title=" methylation"> methylation</a>, <a href="https://publications.waset.org/abstracts/search?q=MGMT" title=" MGMT"> MGMT</a> </p> <a href="https://publications.waset.org/abstracts/66871/the-epigenetic-background-depended-treatment-planning-for-glioblastoma-multiforme" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/66871.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">345</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11426</span> Patient Scheduling Improvement in a Cancer Treatment Clinic Using Optimization Techniques</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Maryam%20Haghi">Maryam Haghi</a>, <a href="https://publications.waset.org/abstracts/search?q=Ivan%20Contreras"> Ivan Contreras</a>, <a href="https://publications.waset.org/abstracts/search?q=Nadia%20%20Bhuiyan"> Nadia Bhuiyan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Chemotherapy is one of the most popular and effective cancer treatments offered to patients in outpatient oncology centers. In such clinics, patients first consult with an oncologist and the oncologist may prescribe a chemotherapy treatment plan for the patient based on the blood test results and the examination of the health status. Then, when the plan is determined, a set of chemotherapy and consultation appointments should be scheduled for the patient. In this work, a comprehensive mathematical formulation for planning and scheduling different types of chemotherapy patients over a planning horizon considering blood test, consultation, pharmacy and treatment stages has been proposed. To be more realistic and to provide an applicable model, this study is focused on a case study related to a major outpatient cancer treatment clinic in Montreal, Canada. Comparing the results of the proposed model with the current practice of the clinic under study shows significant improvements regarding different performance measures. These major improvements in the patients’ schedules reveal that using optimization techniques in planning and scheduling of patients in such highly demanded cancer treatment clinics is an essential step to provide a good coordination between different involved stages which ultimately increases the efficiency of the entire system and promotes the staff and patients' satisfaction. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=chemotherapy%20patients%20scheduling" title="chemotherapy patients scheduling">chemotherapy patients scheduling</a>, <a href="https://publications.waset.org/abstracts/search?q=integer%20programming" title=" integer programming"> integer programming</a>, <a href="https://publications.waset.org/abstracts/search?q=integrated%20scheduling" title=" integrated scheduling"> integrated scheduling</a>, <a href="https://publications.waset.org/abstracts/search?q=staff%20balancing" title=" staff balancing"> staff balancing</a> </p> <a href="https://publications.waset.org/abstracts/101042/patient-scheduling-improvement-in-a-cancer-treatment-clinic-using-optimization-techniques" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/101042.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">175</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11425</span> Strategic Planning in South African Higher Education </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Noxolo%20Mafu">Noxolo Mafu</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study presents an overview of strategic planning in South African higher education institutions by tracing its trends and mystique in order to identify its impact. Over the democratic decades, strategic planning has become integral to institutional survival. It has been used as a potent tool by several institutions to catch up and surpass counterparts. While planning has always been part of higher education, strategic planning should be considered different. Strategic planning is primarily about development and maintenance of a strategic fitting between an institution and its dynamic opportunities. This presupposes existence of sets of stages that institutions pursue of which, can be regarded for assessment of the impact of strategic planning in an institution. The network theory serves guides the study in demystifying apparent organisational networks in strategic planning processes. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=network%20theory" title="network theory">network theory</a>, <a href="https://publications.waset.org/abstracts/search?q=strategy" title=" strategy"> strategy</a>, <a href="https://publications.waset.org/abstracts/search?q=planning" title=" planning"> planning</a>, <a href="https://publications.waset.org/abstracts/search?q=strategic%20planning" title=" strategic planning"> strategic planning</a>, <a href="https://publications.waset.org/abstracts/search?q=assessment" title=" assessment"> assessment</a>, <a href="https://publications.waset.org/abstracts/search?q=impact" title=" impact"> impact</a> </p> <a href="https://publications.waset.org/abstracts/57681/strategic-planning-in-south-african-higher-education" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/57681.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">562</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11424</span> Determination of the Economic Planning Depth for Assembly Process Planning</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=A.%20Kampker">A. Kampker</a>, <a href="https://publications.waset.org/abstracts/search?q=P.%20Burggr%C3%A4f"> P. Burggräf</a>, <a href="https://publications.waset.org/abstracts/search?q=Y.%20B%C3%A4umers"> Y. Bäumers </a> </p> <p class="card-text"><strong>Abstract:</strong></p> In order to be competitive, companies have to reduce their production costs while meeting increasing quality requirements. Therefore, companies try to plan their assembly processes as detailed as possible. However, increasing product individualization leading to a higher number of variants, smaller batch sizes and shorter product life cycles raise the question to what extent the effort of detailed planning is still justified. An important approach in this field of research is the concept of determining the economic planning depth for assembly process planning based on production specific influencing factors. In this paper, first solution hypotheses as well as a first draft of the resulting method will be presented. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=assembly%20process%20planning" title="assembly process planning">assembly process planning</a>, <a href="https://publications.waset.org/abstracts/search?q=economic%20planning%20depth" title=" economic planning depth"> economic planning depth</a>, <a href="https://publications.waset.org/abstracts/search?q=planning%20benefit" title=" planning benefit"> planning benefit</a>, <a href="https://publications.waset.org/abstracts/search?q=planning%20effort" title=" planning effort"> planning effort</a> </p> <a href="https://publications.waset.org/abstracts/30242/determination-of-the-economic-planning-depth-for-assembly-process-planning" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/30242.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">504</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11423</span> Analysis on the Development and Evolution of China’s Territorial Spatial Planning</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=He%20YuanYan">He YuanYan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In recent years, China has implemented the reform of land and space planning. As an important public policy, land and space planning plays a vital role in the construction and development of cities. Land and space planning throughout the country is in full swing, but there are still many disputes from all walks of life. The content, scope, and specific implementation process of land and space planning are also ambiguous, leading to the integration of multiple regulation problems such as unclear authority, unclear responsibilities, and poor planning results during the implementation of land and space planning. Therefore, it is necessary to sort out the development and evolution of domestic and foreign land space planning, clarify the problems and cruxes from the current situation of China's land space planning, and sort out the obstacles and countermeasures to the implementation of this policy, so as to deepen the understanding of the connotation of land space planning. It is of great practical significance for all planners to correctly understand and clarify the specific contents and methods of land space planning and to smoothly promote the implementation of land space planning at all levels. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=territorial%20spatial%20planning" title="territorial spatial planning">territorial spatial planning</a>, <a href="https://publications.waset.org/abstracts/search?q=public%20policy" title=" public policy"> public policy</a>, <a href="https://publications.waset.org/abstracts/search?q=land%20space" title=" land space"> land space</a>, <a href="https://publications.waset.org/abstracts/search?q=overall%20planning" title=" overall planning"> overall planning</a> </p> <a href="https://publications.waset.org/abstracts/159371/analysis-on-the-development-and-evolution-of-chinas-territorial-spatial-planning" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/159371.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">131</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11422</span> Evolution of Cord Absorbed Dose during Larynx Cancer Radiotherapy, with 3D Treatment Planning and Tissue Equivalent Phantom</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohammad%20Hassan%20Heidari">Mohammad Hassan Heidari</a>, <a href="https://publications.waset.org/abstracts/search?q=Amir%20Hossein%20Goodarzi"> Amir Hossein Goodarzi</a>, <a href="https://publications.waset.org/abstracts/search?q=Majid%20Azarniush"> Majid Azarniush</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Radiation doses to tissues and organs were measured using the anthropomorphic phantom as an equivalent to the human body. When high-energy X-rays are externally applied to treat laryngeal cancer, the absorbed dose at the laryngeal lumen is lower than given dose because of air space which it should pass through before reaching the lesion. Specially in case of high-energy X-rays, the loss of dose is considerable. Three-dimensional absorbed dose distributions have been computed for high-energy photon radiation therapy of laryngeal and hypo pharyngeal cancers, using a coaxial pair of opposing lateral beams in fixed positions. Treatment plans obtained under various conditions of irradiation. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning" title="3D treatment planning">3D treatment planning</a>, <a href="https://publications.waset.org/abstracts/search?q=anthropomorphic%20phantom" title=" anthropomorphic phantom"> anthropomorphic phantom</a>, <a href="https://publications.waset.org/abstracts/search?q=larynx%20cancer" title=" larynx cancer"> larynx cancer</a>, <a href="https://publications.waset.org/abstracts/search?q=radiotherapy" title=" radiotherapy "> radiotherapy </a> </p> <a href="https://publications.waset.org/abstracts/3432/evolution-of-cord-absorbed-dose-during-larynx-cancer-radiotherapy-with-3d-treatment-planning-and-tissue-equivalent-phantom" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/3432.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">547</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11421</span> [Keynote] Implementation of Quality Control Procedures in Radiotherapy CT Simulator </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=B.%20Petrovi%C4%87">B. Petrović</a>, <a href="https://publications.waset.org/abstracts/search?q=L.%20Rutonjski"> L. Rutonjski</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Baucal"> M. Baucal</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Teodorovi%C4%87"> M. Teodorović</a>, <a href="https://publications.waset.org/abstracts/search?q=O.%20%C4%8Cudi%C4%87"> O. Čudić</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Basari%C4%87"> B. Basarić</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Purpose/Objective: Radiotherapy treatment planning requires use of CT simulator, in order to acquire CT images. The overall performance of CT simulator determines the quality of radiotherapy treatment plan, and at the end, the outcome of treatment for every single patient. Therefore, it is strongly advised by international recommendations, to set up a quality control procedures for every machine involved in radiotherapy treatment planning process, including the CT scanner/ simulator. The overall process requires number of tests, which are used on daily, weekly, monthly or yearly basis, depending on the feature tested. Materials/Methods: Two phantoms were used: a dedicated phantom CIRS 062QA, and a QA phantom obtained with the CT simulator. The examined CT simulator was Siemens Somatom Definition as Open, dedicated for radiation therapy treatment planning. The CT simulator has a built in software, which enables fast and simple evaluation of CT QA parameters, using the phantom provided with the CT simulator. On the other hand, recommendations contain additional test, which were done with the CIRS phantom. Also, legislation on ionizing radiation protection requires CT testing in defined periods of time. Taking into account the requirements of law, built in tests of a CT simulator, and international recommendations, the intitutional QC programme for CT imulator is defined, and implemented. Results: The CT simulator parameters evaluated through the study were following: CT number accuracy, field uniformity, complete CT to ED conversion curve, spatial and contrast resolution, image noise, slice thickness, and patient table stability.The following limits are established and implemented: CT number accuracy limits are +/- 5 HU of the value at the comissioning. Field uniformity: +/- 10 HU in selected ROIs. Complete CT to ED curve for each tube voltage must comply with the curve obtained at comissioning, with deviations of not more than 5%. Spatial and contrast resultion tests must comply with the tests obtained at comissioning, otherwise machine requires service. Result of image noise test must fall within the limit of 20% difference of the base value. Slice thickness must meet manufacturer specifications, and patient stability with longitudinal transfer of loaded table must not differ of more than 2mm vertical deviation. Conclusion: The implemented QA tests gave overall basic understanding of CT simulator functionality and its clinical effectiveness in radiation treatment planning. The legal requirement to the clinic is to set up it’s own QA programme, with minimum testing, but it remains user’s decision whether additional testing, as recommended by international organizations, will be implemented, so to improve the overall quality of radiation treatment planning procedure, as the CT image quality used for radiation treatment planning, influences the delineation of a tumor and calculation accuracy of treatment planning system, and finally delivery of radiation treatment to a patient. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=CT%20simulator" title="CT simulator">CT simulator</a>, <a href="https://publications.waset.org/abstracts/search?q=radiotherapy" title=" radiotherapy"> radiotherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=quality%20control" title=" quality control"> quality control</a>, <a href="https://publications.waset.org/abstracts/search?q=QA%20programme" title=" QA programme"> QA programme</a> </p> <a href="https://publications.waset.org/abstracts/28168/keynote-implementation-of-quality-control-procedures-in-radiotherapy-ct-simulator" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/28168.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">534</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11420</span> Effective Retirement Planning: Exploring Financial Planning Behavior in Malaysia</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Stanley%20Yap%20Peng%20Lok">Stanley Yap Peng Lok</a>, <a href="https://publications.waset.org/abstracts/search?q=Chong%20Wei%20Ying"> Chong Wei Ying</a>, <a href="https://publications.waset.org/abstracts/search?q=Leow%20Hon%20Wei"> Leow Hon Wei</a>, <a href="https://publications.waset.org/abstracts/search?q=Fatemeh%20Kimiyaghalam"> Fatemeh Kimiyaghalam</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Purpose: This paper examines how people treat on the importance of financial planning for their retirement. There is lack of standard instrument that enable us to access the retirement planning behavior. This paper studies the reliability and validity of a proposed scale for accessing this behavior. Design/methodology/approach: The Retirement Planning Behavior scale (RPB) is developed from the results of reviewing different papers on this topic. A total of 900 Malaysians from the age of 18 and above are used as the sample. Findings: Our results show, firstly, the RPB meets all criteria from the instrument reliability and validity which based on the theory of planned behavior. Second, our findings propose two components for this RPB scale; attitude toward planning for retirement and intention towards retirement planning behavior. Practical implication: An effective retirement planning achieves financial independence after the retirement. Our findings have important implications for the scope and significance of the retirement planning behavior measurement, especially for retirees. Originality/value: This study proposes a new approach to cater consumers’ needs for retirement planning. Therefore, consumers are able to achieve financial independence in their retirement age. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=retirement%20planning%20behavior%20%28RPB%29%20scale" title="retirement planning behavior (RPB) scale">retirement planning behavior (RPB) scale</a>, <a href="https://publications.waset.org/abstracts/search?q=reliability" title=" reliability"> reliability</a>, <a href="https://publications.waset.org/abstracts/search?q=validity" title=" validity"> validity</a>, <a href="https://publications.waset.org/abstracts/search?q=retirement%20planning" title=" retirement planning"> retirement planning</a>, <a href="https://publications.waset.org/abstracts/search?q=financial%20independence" title=" financial independence"> financial independence</a> </p> <a href="https://publications.waset.org/abstracts/79083/effective-retirement-planning-exploring-financial-planning-behavior-in-malaysia" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/79083.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">407</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11419</span> Verification of Dosimetric Commissioning Accuracy of Flattening Filter Free Intensity Modulated Radiation Therapy and Volumetric Modulated Therapy Delivery Using Task Group 119 Guidelines</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Arunai%20Nambi%20Raj%20N.">Arunai Nambi Raj N.</a>, <a href="https://publications.waset.org/abstracts/search?q=Kaviarasu%20Karunakaran"> Kaviarasu Karunakaran</a>, <a href="https://publications.waset.org/abstracts/search?q=Krishnamurthy%20K."> Krishnamurthy K.</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The purpose of this study was to create American Association of Physicist in Medicine (AAPM) Task Group 119 (TG 119) benchmark plans for flattening filter free beam (FFF) deliveries of intensity modulated radiation therapy (IMRT) and volumetric arc therapy (VMAT) in the Eclipse treatment planning system. The planning data were compared with the flattening filter (FF) IMRT & VMAT plan data to verify the dosimetric commissioning accuracy of FFF deliveries. AAPM TG 119 proposed a set of test cases called multi-target, mock prostate, mock head and neck, and C-shape to ascertain the overall accuracy of IMRT planning, measurement, and analysis. We used these test cases to investigate the performance of the Eclipse Treatment planning system for the flattening filter free beam deliveries. For these test cases, we generated two sets of treatment plans, the first plan using 7–9 IMRT fields and a second plan utilizing two arc VMAT technique for both the beam deliveries (6 MV FF, 6MV FFF, 10 MV FF and 10 MV FFF). The planning objectives and dose were set as described in TG 119. The dose prescriptions for multi-target, mock prostate, mock head and neck, and C-shape were taken as 50, 75.6, 50 and 50 Gy, respectively. The point dose (mean dose to the contoured chamber volume) at the specified positions/locations was measured using compact (CC‑13) ion chamber. The composite planar dose and per-field gamma analysis were measured with IMatriXX Evaluation 2D array with OmniPro IMRT Software (version 1.7b). FFF beam deliveries of IMRT and VMAT plans were comparable to flattening filter beam deliveries. Our planning and quality assurance results matched with TG 119 data. AAPM TG 119 test cases are useful to generate FFF benchmark plans. From the obtained data in this study, we conclude that the commissioning of FFF IMRT and FFF VMAT delivery were found within the limits of TG-119 and the performance of the Eclipse treatment planning system for FFF plans were found satisfactorily. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=flattening%20filter%20free%20beams" title="flattening filter free beams">flattening filter free beams</a>, <a href="https://publications.waset.org/abstracts/search?q=intensity%20modulated%20radiation%20therapy" title=" intensity modulated radiation therapy"> intensity modulated radiation therapy</a>, <a href="https://publications.waset.org/abstracts/search?q=task%20group%20119" title=" task group 119"> task group 119</a>, <a href="https://publications.waset.org/abstracts/search?q=volumetric%20modulated%20arc%20therapy" title=" volumetric modulated arc therapy"> volumetric modulated arc therapy</a> </p> <a href="https://publications.waset.org/abstracts/106771/verification-of-dosimetric-commissioning-accuracy-of-flattening-filter-free-intensity-modulated-radiation-therapy-and-volumetric-modulated-therapy-delivery-using-task-group-119-guidelines" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/106771.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">146</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11418</span> Comparison of an Anthropomorphic PRESAGE® Dosimeter and Radiochromic Film with a Commercial Radiation Treatment Planning System for Breast IMRT: A Feasibility Study</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Khalid%20Iqbal">Khalid Iqbal</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This work presents a comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film measurements with a commercial treatment planning system to determine the feasibility of PRESAGE® for 3D dosimetry in breast IMRT. An anthropomorphic PRESAGE® phantom was created in the shape of a breast phantom. A five-field IMRT plan was generated with a commercially available treatment planning system and delivered to the PRESAGE® phantom. The anthropomorphic PRESAGE® was scanned with the Duke midsized optical CT scanner (DMOS-RPC) and the OD distribution was converted to dose. Comparisons were performed between the dose distribution calculated with the Pinnacle3 treatment planning system, PRESAGE®, and EBT2 film measurements. DVHs, gamma maps, and line profiles were used to evaluate the agreement. Gamma map comparisons showed that Pinnacle3 agreed with PRESAGE® as greater than 95% of comparison points for the PTV passed a ± 3%/± 3 mm criterion when the outer 8 mm of phantom data were discluded. Edge artifacts were observed in the optical CT reconstruction, from the surface to approximately 8 mm depth. These artifacts resulted in dose differences between Pinnacle3 and PRESAGE® of up to 5% between the surface and a depth of 8 mm and decreased with increasing depth in the phantom. Line profile comparisons between all three independent measurements yielded a maximum difference of 2% within the central 80% of the field width. For the breast IMRT plan studied, the Pinnacle3 calculations agreed with PRESAGE® measurements to within the ±3%/± 3 mm gamma criterion. This work demonstrates the feasibility of the PRESAGE® to be fashioned into anthropomorphic shape, and establishes the accuracy of Pinnacle3 for breast IMRT. Furthermore, these data have established the groundwork for future investigations into 3D dosimetry with more complex anthropomorphic phantoms. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=3D%20dosimetry" title="3D dosimetry">3D dosimetry</a>, <a href="https://publications.waset.org/abstracts/search?q=PRESAGE%C2%AE" title=" PRESAGE®"> PRESAGE®</a>, <a href="https://publications.waset.org/abstracts/search?q=IMRT" title=" IMRT"> IMRT</a>, <a href="https://publications.waset.org/abstracts/search?q=QA" title=" QA"> QA</a>, <a href="https://publications.waset.org/abstracts/search?q=EBT2%20GAFCHROMIC%20film" title=" EBT2 GAFCHROMIC film"> EBT2 GAFCHROMIC film</a> </p> <a href="https://publications.waset.org/abstracts/5858/comparison-of-an-anthropomorphic-presage-dosimeter-and-radiochromic-film-with-a-commercial-radiation-treatment-planning-system-for-breast-imrt-a-feasibility-study" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/5858.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">416</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11417</span> Evaluating the Dosimetric Performance for 3D Treatment Planning System for Wedged and Off-Axis Fields</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Nashaat%20A.%20Deiab">Nashaat A. Deiab</a>, <a href="https://publications.waset.org/abstracts/search?q=Aida%20Radwan"> Aida Radwan</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20S.%20Yahiya"> Mohamed S. Yahiya</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20Elnagdy"> Mohamed Elnagdy</a>, <a href="https://publications.waset.org/abstracts/search?q=Rasha%20Moustafa"> Rasha Moustafa</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study is to evaluate the dosimetric performance of our institution's 3D treatment planning system for wedged and off-axis 6MV photon beams, guided by the recommended QA tests documented in the AAPM TG53; NCS report 15 test packages, IAEA TRS 430 and ESTRO booklet no.7. The study was performed for Elekta Precise linear accelerator designed for clinical range of 4, 6 and 15 MV photon beams with asymmetric jaws and fully integrated multileaf collimator that enables high conformance to target with sharp field edges. Ten tests were applied on solid water equivalent phantom along with 2D array dose detection system. The calculated doses using 3D treatment planning system PrecisePLAN were compared with measured doses to make sure that the dose calculations are accurate for simple situations such as square and elongated fields, different SSD, beam modifiers e.g. wedges, blocks, MLC-shaped fields and asymmetric collimator settings. The QA results showed dosimetric accuracy of the TPS within the specified tolerance limits. Except for large elongated wedged field, the central axis and outside central axis have errors of 0.2% and 0.5%, respectively, and off- planned and off-axis elongated fields the region outside the central axis of the beam errors are 0.2% and 1.1%, respectively. The dosimetric investigated results yielded differences within the accepted tolerance level as recommended. Differences between dose values predicted by the TPS and measured values at the same point are the result from limitations of the dose calculation, uncertainties in the measurement procedure, or fluctuations in the output of the accelerator. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=quality%20assurance" title="quality assurance">quality assurance</a>, <a href="https://publications.waset.org/abstracts/search?q=dose%20calculation" title=" dose calculation"> dose calculation</a>, <a href="https://publications.waset.org/abstracts/search?q=wedged%20fields" title=" wedged fields"> wedged fields</a>, <a href="https://publications.waset.org/abstracts/search?q=off-axis%20fields" title=" off-axis fields"> off-axis fields</a>, <a href="https://publications.waset.org/abstracts/search?q=3D%20treatment%0D%0Aplanning%20system" title=" 3D treatment planning system"> 3D treatment planning system</a>, <a href="https://publications.waset.org/abstracts/search?q=photon%20beam" title=" photon beam"> photon beam</a> </p> <a href="https://publications.waset.org/abstracts/11134/evaluating-the-dosimetric-performance-for-3d-treatment-planning-system-for-wedged-and-off-axis-fields" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/11134.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">446</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11416</span> Methodological Analysis and Exploration of Feminist Planning Research in the Field of Urban and Rural Planning</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Xi%20Zuo">Xi Zuo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> As a part of the urban population that cannot be ignored, women have long been less involved in urban planning due to socio-economic constraints. Urban planning and development have long been influenced by the mainstream "male standard," paying less attention to women's needs for space in the city. However, with the development of the economy and society and the improvement of women's social status, their participation in urban life is gradually increasing, and their needs for the city are diversifying. Therefore, different scholars, planning designers and governmental departments have explored this field in different degrees and directions. This paper summarizes the research on urban planning from women's perspectives and, discusses its strengths, weaknesses, and methodology with specific case studies, and then further discusses the direction of further research on this topic. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=urban%20planning" title="urban planning">urban planning</a>, <a href="https://publications.waset.org/abstracts/search?q=feminism" title=" feminism"> feminism</a>, <a href="https://publications.waset.org/abstracts/search?q=methodology" title=" methodology"> methodology</a>, <a href="https://publications.waset.org/abstracts/search?q=gender" title=" gender"> gender</a> </p> <a href="https://publications.waset.org/abstracts/183971/methodological-analysis-and-exploration-of-feminist-planning-research-in-the-field-of-urban-and-rural-planning" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/183971.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">80</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11415</span> Implementation-Oriented Discussion for Historical and Cultural Villages’ Conservation Planning</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Xing%20Zhang">Xing Zhang</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Since the State Council of China issued the Regulations on the Conservation of Historical Cultural Towns and Villages in 2008, formulation of conservation planning has been carried out in national, provincial and municipal historical and cultural villages for protection needs, which provides a legal basis for inheritance of historical culture and protection of historical resources. Although the quantity and content of the conservation planning are continually increasing, the implementation and application are still ambiguous. To solve the aforementioned problems, this paper explores methods to enhance the implementation of conservation planning from the perspective of planning formulation. Specifically, the technical framework of &quot;overall objectives planning - sub-objectives planning - zoning guidelines - implementation by stages&quot; is proposed to implement the planning objectives in different classifications and stages. Then combined with details of the Qiqiao historical and cultural village conservation planning project in Ningbo, five sub-objectives are set, which are implemented through the village zoning guidelines. At the same time, the key points and specific projects in the near-term, medium-term and long-term work are clarified, and the spatial planning is transformed into the action plan with time scale. The proposed framework and method provide a reference for the implementation and management of the conservation planning of historical and cultural villages in the future. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=conservation%20planning" title="conservation planning">conservation planning</a>, <a href="https://publications.waset.org/abstracts/search?q=planning%20by%20stages" title=" planning by stages"> planning by stages</a>, <a href="https://publications.waset.org/abstracts/search?q=planning%20implementation" title=" planning implementation"> planning implementation</a>, <a href="https://publications.waset.org/abstracts/search?q=zoning%20guidelines" title=" zoning guidelines"> zoning guidelines</a> </p> <a href="https://publications.waset.org/abstracts/99602/implementation-oriented-discussion-for-historical-and-cultural-villages-conservation-planning" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/99602.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">240</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11414</span> On the Differentiation of Strategic Spatial Planning Making Mechanisms in New Era: between Melbourne and Tianjin</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Z.%20Liu">Z. Liu</a>, <a href="https://publications.waset.org/abstracts/search?q=K.%20Cao"> K. Cao</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Strategic spatial planning, which is taken as an effective and competitive way for the governors of the city to improve the development and management level of a city, has been blooming in recent years all over the world. In the context of globalization and informatization, strategic spatial planning must transfer its focus on three different levels: global, regional and urban. Internal and external changes in environmental conditions lead to new advances in strategic planning both theoretically and practically. However, such advances or changes respond differently to cities on account of different dynamic mechanisms. This article aims at two cities of Tianjin in China and Melbourne in Australia, through a comparative study on strategic planning, to explore the differentiation of mechanisms in urban planning making. By comparison and exploration, the purpose of this article is to exhibit two different planning worlds between western and Chinese in a new way nowadays. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=differentiation" title="differentiation">differentiation</a>, <a href="https://publications.waset.org/abstracts/search?q=Tianjin%20China" title=" Tianjin China"> Tianjin China</a>, <a href="https://publications.waset.org/abstracts/search?q=Melbourne%20Australia" title=" Melbourne Australia"> Melbourne Australia</a>, <a href="https://publications.waset.org/abstracts/search?q=strategic%20planning" title=" strategic planning"> strategic planning</a> </p> <a href="https://publications.waset.org/abstracts/7791/on-the-differentiation-of-strategic-spatial-planning-making-mechanisms-in-new-era-between-melbourne-and-tianjin" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/7791.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">620</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11413</span> Evaluation of Golden Beam Data for the Commissioning of 6 and 18 MV Photons Beams in Varian Linear Accelerator</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Shoukat%20Ali">Shoukat Ali</a>, <a href="https://publications.waset.org/abstracts/search?q=Abdul%20Qadir%20Jandga"> Abdul Qadir Jandga</a>, <a href="https://publications.waset.org/abstracts/search?q=Amjad%20Hussain"> Amjad Hussain</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Objective: The main purpose of this study is to compare the Percent Depth dose (PDD) and In-plane and cross-plane profiles of Varian Golden beam data to the measured data of 6 and 18 MV photons for the commissioning of Eclipse treatment planning system. Introduction: Commissioning of treatment planning system requires an extensive acquisition of beam data for the clinical use of linear accelerators. Accurate dose delivery require to enter the PDDs, Profiles and dose rate tables for open and wedges fields into treatment planning system, enabling to calculate the MUs and dose distribution. Varian offers a generic set of beam data as a reference data, however not recommend for clinical use. In this study, we compared the generic beam data with the measured beam data to evaluate the reliability of generic beam data to be used for the clinical purpose. Methods and Material: PDDs and Profiles of Open and Wedge fields for different field sizes and at different depths measured as per Varian’s algorithm commissioning guideline. The measurement performed with PTW 3D-scanning water phantom with semi-flex ion chamber and MEPHYSTO software. The online available Varian Golden Beam Data compared with the measured data to evaluate the accuracy of the golden beam data to be used for the commissioning of Eclipse treatment planning system. Results: The deviation between measured vs. golden beam data was in the range of 2% max. In PDDs, the deviation increases more in the deeper depths than the shallower depths. Similarly, profiles have the same trend of increasing deviation at large field sizes and increasing depths. Conclusion: Study shows that the percentage deviation between measured and golden beam data is within the acceptable tolerance and therefore can be used for the commissioning process; however, verification of small subset of acquired data with the golden beam data should be mandatory before clinical use. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=percent%20depth%20dose" title="percent depth dose">percent depth dose</a>, <a href="https://publications.waset.org/abstracts/search?q=flatness" title=" flatness"> flatness</a>, <a href="https://publications.waset.org/abstracts/search?q=symmetry" title=" symmetry"> symmetry</a>, <a href="https://publications.waset.org/abstracts/search?q=golden%20beam%20data" title=" golden beam data"> golden beam data</a> </p> <a href="https://publications.waset.org/abstracts/22976/evaluation-of-golden-beam-data-for-the-commissioning-of-6-and-18-mv-photons-beams-in-varian-linear-accelerator" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/22976.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">489</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11412</span> The Validation of RadCalc for Clinical Use: An Independent Monitor Unit Verification Software</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Junior%20Akunzi">Junior Akunzi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In the matter of patient treatment planning quality assurance in 3D conformational therapy (3D-CRT) and volumetric arc therapy (VMAT or RapidArc), the independent monitor unit verification calculation (MUVC) is an indispensable part of the process. Concerning 3D-CRT treatment planning, the MUVC can be performed manually applying the standard ESTRO formalism. However, due to the complex shape and the amount of beams in advanced treatment planning technic such as RapidArc, the manual independent MUVC is inadequate. Therefore, commercially available software such as RadCalc can be used to perform the MUVC in complex treatment planning been. Indeed, RadCalc (version 6.3 LifeLine Inc.) uses a simplified Clarkson algorithm to compute the dose contribution for individual RapidArc fields to the isocenter. The purpose of this project is the validation of RadCalc in 3D-CRT and RapidArc for treatment planning dosimetry quality assurance at Antoine Lacassagne center (Nice, France). Firstly, the interfaces between RadCalc and our treatment planning systems (TPS) Isogray (version 4.2) and Eclipse (version13.6) were checked for data transfer accuracy. Secondly, we created test plans in both Isogray and Eclipse featuring open fields, wedges fields, and irregular MLC fields. These test plans were transferred from TPSs according to the radiotherapy protocol of DICOM RT to RadCalc and the linac via Mosaiq (version 2.5). Measurements were performed in water phantom using a PTW cylindrical semiflex ionisation chamber (0.3 cm³, 31010) and compared with the TPSs and RadCalc calculation. Finally, 30 3D-CRT plans and 40 RapidArc plans created with patients CT scan were recalculated using the CT scan of a solid PMMA water equivalent phantom for 3D-CRT and the Octavius II phantom (PTW) CT scan for RapidArc. Next, we measure the doses delivered into these phantoms for each plan with a 0.3 cm³ PTW 31010 cylindrical semiflex ionisation chamber (3D-CRT) and 0.015 cm³ PTW PinPoint ionisation chamber (Rapidarc). For our test plans, good agreements were found between calculation (RadCalc and TPSs) and measurement (mean: 1.3%; standard deviation: ± 0.8%). Regarding the patient plans, the measured doses were compared to the calculation in RadCalc and in our TPSs. Moreover, RadCalc calculations were compared to Isogray and Eclispse ones. Agreements better than (2.8%; ± 1.2%) were found between RadCalc and TPSs. As for the comparison between calculation and measurement the agreement for all of our plans was better than (2.3%; ± 1.1%). The independent MU verification calculation software RadCal has been validated for clinical use and for both 3D-CRT and RapidArc techniques. The perspective of this project includes the validation of RadCal for the Tomotherapy machine installed at centre Antoine Lacassagne. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=3D%20conformational%20radiotherapy" title="3D conformational radiotherapy">3D conformational radiotherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=intensity%20modulated%20radiotherapy" title=" intensity modulated radiotherapy"> intensity modulated radiotherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=monitor%20unit%20calculation" title=" monitor unit calculation"> monitor unit calculation</a>, <a href="https://publications.waset.org/abstracts/search?q=dosimetry%20quality%20assurance" title=" dosimetry quality assurance"> dosimetry quality assurance</a> </p> <a href="https://publications.waset.org/abstracts/78071/the-validation-of-radcalc-for-clinical-use-an-independent-monitor-unit-verification-software" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/78071.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">216</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11411</span> Agile Succession Planning in the Post-Covid World</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ashneel%20Kumar%20Singh">Ashneel Kumar Singh</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The COVID-19 pandemic has dramatically transformed the global workforce, leading to significant challenges in staffing and employment. The shift to remote work, the health risks posed by the virus, and the phenomenon known as ‘The Great Termination’ have all contributed to the disruption of traditional succession planning methods. This paper explores how agile succession planning can be effectively implemented in the post-COVID world to retain top talent and ensure organizational resilience. Through a review of the literature and practical examples, the paper discusses the difficulties of succession planning in the current environment and the importance of adopting an agile approach and offers recommendations for businesses to navigate the complexities of succession planning in a rapidly changing landscape. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=agile%20succession%20planning" title="agile succession planning">agile succession planning</a>, <a href="https://publications.waset.org/abstracts/search?q=adopt%20a%20culture%20of%20continuous%20learning" title=" adopt a culture of continuous learning"> adopt a culture of continuous learning</a>, <a href="https://publications.waset.org/abstracts/search?q=create%20a%20multi-successor%20planning%20approach" title=" create a multi-successor planning approach"> create a multi-successor planning approach</a>, <a href="https://publications.waset.org/abstracts/search?q=the%20great%20termination" title=" the great termination"> the great termination</a> </p> <a href="https://publications.waset.org/abstracts/190099/agile-succession-planning-in-the-post-covid-world" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/190099.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">33</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11410</span> Automatic Segmentation of 3D Tomographic Images Contours at Radiotherapy Planning in Low Cost Solution </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=D.%20F.%20Carvalho">D. F. Carvalho</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20O.%20Uscamayta"> A. O. Uscamayta</a>, <a href="https://publications.waset.org/abstracts/search?q=J.%20C.%20Guerrero"> J. C. Guerrero</a>, <a href="https://publications.waset.org/abstracts/search?q=H.%20F.%20Oliveira"> H. F. Oliveira</a>, <a href="https://publications.waset.org/abstracts/search?q=P.%20M.%20Azevedo-Marques"> P. M. Azevedo-Marques</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The creation of vector contours slices (ROIs) on body silhouettes in oncologic patients is an important step during the radiotherapy planning in clinic and hospitals to ensure the accuracy of oncologic treatment. The radiotherapy planning of patients is performed by complex softwares focused on analysis of tumor regions, protection of organs at risk (OARs) and calculation of radiation doses for anomalies (tumors). These softwares are supplied for a few manufacturers and run over sophisticated workstations with vector processing presenting a cost of approximately twenty thousand dollars. The Brazilian project SIPRAD (Radiotherapy Planning System) presents a proposal adapted to the emerging countries reality that generally does not have the monetary conditions to acquire some radiotherapy planning workstations, resulting in waiting queues for new patients treatment. The SIPRAD project is composed by a set of integrated and interoperabilities softwares that are able to execute all stages of radiotherapy planning on simple personal computers (PCs) in replace to the workstations. The goal of this work is to present an image processing technique, computationally feasible, that is able to perform an automatic contour delineation in patient body silhouettes (SIPRAD-Body). The SIPRAD-Body technique is performed in tomography slices under grayscale images, extending their use with a greedy algorithm in three dimensions. SIPRAD-Body creates an irregular polyhedron with the Canny Edge adapted algorithm without the use of preprocessing filters, as contrast and brightness. In addition, comparing the technique SIPRAD-Body with existing current solutions is reached a contours similarity at least 78%. For this comparison is used four criteria: contour area, contour length, difference between the mass centers and Jaccard index technique. SIPRAD-Body was tested in a set of oncologic exams provided by the Clinical Hospital of the University of Sao Paulo (HCRP-USP). The exams were applied in patients with different conditions of ethnology, ages, tumor severities and body regions. Even in case of services that have already workstations, it is possible to have SIPRAD working together PCs because of the interoperability of communication between both systems through the DICOM protocol that provides an increase of workflow. Therefore, the conclusion is that SIPRAD-Body technique is feasible because of its degree of similarity in both new radiotherapy planning services and existing services. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=radiotherapy" title="radiotherapy">radiotherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=image%20processing" title=" image processing"> image processing</a>, <a href="https://publications.waset.org/abstracts/search?q=DICOM%20RT" title=" DICOM RT"> DICOM RT</a>, <a href="https://publications.waset.org/abstracts/search?q=Treatment%20Planning%20System%20%28TPS%29" title=" Treatment Planning System (TPS)"> Treatment Planning System (TPS)</a> </p> <a href="https://publications.waset.org/abstracts/75533/automatic-segmentation-of-3d-tomographic-images-contours-at-radiotherapy-planning-in-low-cost-solution" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/75533.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">296</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11409</span> The Linkage of Urban and Energy Planning for Sustainable Cities: The Case of Denmark and Germany</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jens-Phillip%20Petersen">Jens-Phillip Petersen</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The reduction of GHG emissions in buildings is a focus area of national energy policies in Europe, because buildings are responsible for a major share of the final energy consumption. It is at local scale where policies to increase the share of renewable energies and energy efficiency measures get implemented. Municipalities, as local authorities and responsible entity for land-use planning, have a direct influence on urban patterns and energy use, which makes them key actors in the transition towards sustainable cities. Hence, synchronizing urban planning with energy planning offers great potential to increase society&rsquo;s energy-efficiency; this has a high significance to reach GHG-reduction targets. In this paper, the actual linkage of urban planning and energy planning in Denmark and Germany was assessed; substantive barriers preventing their integration and driving factors that lead to successful transitions towards a holistic urban energy planning procedures were identified. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=energy%20planning" title="energy planning">energy planning</a>, <a href="https://publications.waset.org/abstracts/search?q=urban%20planning" title=" urban planning"> urban planning</a>, <a href="https://publications.waset.org/abstracts/search?q=renewable%20energies" title=" renewable energies"> renewable energies</a>, <a href="https://publications.waset.org/abstracts/search?q=sustainable%20cities" title=" sustainable cities"> sustainable cities</a> </p> <a href="https://publications.waset.org/abstracts/42208/the-linkage-of-urban-and-energy-planning-for-sustainable-cities-the-case-of-denmark-and-germany" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/42208.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">351</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11408</span> Determination of the Risks of Heart Attack at the First Stage as Well as Their Control and Resource Planning with the Method of Data Mining</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=I%CC%87brahi%CC%87m%20Kara">İbrahi̇m Kara</a>, <a href="https://publications.waset.org/abstracts/search?q=Seher%20Arslankaya"> Seher Arslankaya</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Frequently preferred in the field of engineering in particular, data mining has now begun to be used in the field of health as well since the data in the health sector have reached great dimensions. With data mining, it is aimed to reveal models from the great amounts of raw data in agreement with the purpose and to search for the rules and relationships which will enable one to make predictions about the future from the large amount of data set. It helps the decision-maker to find the relationships among the data which form at the stage of decision-making. In this study, it is aimed to determine the risk of heart attack at the first stage, to control it, and to make its resource planning with the method of data mining. Through the early and correct diagnosis of heart attacks, it is aimed to reveal the factors which affect the diseases, to protect health and choose the right treatment methods, to reduce the costs in health expenditures, and to shorten the durations of patients’ stay at hospitals. In this way, the diagnosis and treatment costs of a heart attack will be scrutinized, which will be useful to determine the risk of the disease at the first stage, to control it, and to make its resource planning. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=data%20mining" title="data mining">data mining</a>, <a href="https://publications.waset.org/abstracts/search?q=decision%20support%20systems" title=" decision support systems"> decision support systems</a>, <a href="https://publications.waset.org/abstracts/search?q=heart%20attack" title=" heart attack"> heart attack</a>, <a href="https://publications.waset.org/abstracts/search?q=health%20sector" title=" health sector"> health sector</a> </p> <a href="https://publications.waset.org/abstracts/49600/determination-of-the-risks-of-heart-attack-at-the-first-stage-as-well-as-their-control-and-resource-planning-with-the-method-of-data-mining" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/49600.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">356</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11407</span> Application of Production Planning to Improve Operation in Local Factory</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Bashayer%20Al-Enezi">Bashayer Al-Enezi</a>, <a href="https://publications.waset.org/abstracts/search?q=Budoor%20Al-Sabti"> Budoor Al-Sabti</a>, <a href="https://publications.waset.org/abstracts/search?q=Eman%20Al-Durai"> Eman Al-Durai</a>, <a href="https://publications.waset.org/abstracts/search?q=Fatmah%20Kalban"> Fatmah Kalban</a>, <a href="https://publications.waset.org/abstracts/search?q=Meshael%20Ahmed"> Meshael Ahmed</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Production planning and control principles are concerned with planning, controlling and balancing all aspects of manufacturing including raw materials, finished goods, production schedules, and equipment requirements. Hence, an effective production planning and control system is very critical to the success of any factory. This project will focus on the application of production planning and control principles on “The National Canned Food Production and Trading Company (NCFP)” factory to find problems or areas for improvement. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=production%20planning" title="production planning">production planning</a>, <a href="https://publications.waset.org/abstracts/search?q=operations%20improvement" title=" operations improvement"> operations improvement</a>, <a href="https://publications.waset.org/abstracts/search?q=inventory%20management" title=" inventory management"> inventory management</a>, <a href="https://publications.waset.org/abstracts/search?q=National%20Canned%20Food%20Production%20and%20Trading%20Company%20%28NCFP%29" title=" National Canned Food Production and Trading Company (NCFP)"> National Canned Food Production and Trading Company (NCFP)</a> </p> <a href="https://publications.waset.org/abstracts/10770/application-of-production-planning-to-improve-operation-in-local-factory" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/10770.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">506</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11406</span> Audit of TPS photon beam dataset for small field output factors using OSLDs against RPC standard dataset</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Asad%20Yousuf">Asad Yousuf</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Purpose: The aim of the present study was to audit treatment planning system beam dataset for small field output factors against standard dataset produced by radiological physics center (RPC) from a multicenter study. Such data are crucial for validity of special techniques, i.e., IMRT or stereotactic radiosurgery. Materials/Method: In this study, multiple small field size output factor datasets were measured and calculated for 6 to 18 MV x-ray beams using the RPC recommend methods. These beam datasets were measured at 10 cm depth for 10 × 10 cm2 to 2 × 2 cm2 field sizes, defined by collimator jaws at 100 cm. The measurements were made with a Landauer’s nanoDot OSLDs whose volume is small enough to gather a full ionization reading even for the 1×1 cm2 field size. At our institute the beam data including output factors have been commissioned at 5 cm depth with an SAD setup. For comparison with the RPC data, the output factors were converted to an SSD setup using tissue phantom ratios. SSD setup also enables coverage of the ion chamber in 2×2 cm2 field size. The measured output factors were also compared with those calculated by Eclipse™ treatment planning software. Result: The measured and calculated output factors are in agreement with RPC dataset within 1% and 4% respectively. The large discrepancies in TPS reflect the increased challenge in converting measured data into a commissioned beam model for very small fields. Conclusion: OSLDs are simple, durable, and accurate tool to verify doses that delivered using small photon beam fields down to a 1x1 cm2 field sizes. The study emphasizes that the treatment planning system should always be evaluated for small field out factors for the accurate dose delivery in clinical setting. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=small%20field%20dosimetry" title="small field dosimetry">small field dosimetry</a>, <a href="https://publications.waset.org/abstracts/search?q=optically%20stimulated%20luminescence" title=" optically stimulated luminescence"> optically stimulated luminescence</a>, <a href="https://publications.waset.org/abstracts/search?q=audit%20treatment" title=" audit treatment"> audit treatment</a>, <a href="https://publications.waset.org/abstracts/search?q=radiological%20physics%20center" title=" radiological physics center"> radiological physics center</a> </p> <a href="https://publications.waset.org/abstracts/7998/audit-of-tps-photon-beam-dataset-for-small-field-output-factors-using-oslds-against-rpc-standard-dataset" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/7998.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">327</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11405</span> Open Fields&#039; Dosimetric Verification for a Commercially-Used 3D Treatment Planning System</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Nashaat%20A.%20Deiab">Nashaat A. Deiab</a>, <a href="https://publications.waset.org/abstracts/search?q=Aida%20Radwan"> Aida Radwan</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20Elnagdy"> Mohamed Elnagdy</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20S.%20Yahiya"> Mohamed S. Yahiya</a>, <a href="https://publications.waset.org/abstracts/search?q=Rasha%20Moustafa"> Rasha Moustafa</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study is to evaluate and investigate the dosimetric performance of our institution's 3D treatment planning system, Elekta PrecisePLAN, for open 6MV fields including square, rectangular, variation in SSD, centrally blocked, missing tissue, square MLC and MLC shaped fields guided by the recommended QA tests prescribed in AAPM TG53, NCS report 15 test packages, IAEA TRS 430 and ESTRO booklet no.7. The study was performed for Elekta Precise linear accelerator designed for clinical range of 4, 6 and 15 MV photon beams with asymmetric jaws and fully integrated multileaf collimator that enables high conformance to target with sharp field edges. Seven different tests were done applied on solid water equivalent phantom along with 2D array dose detection system, the calculated doses using 3D treatment planning system PrecisePLAN, compared with measured doses to make sure that the dose calculations are accurate for open fields including square, rectangular, variation in SSD, centrally blocked, missing tissue, square MLC and MLC shaped fields. The QA results showed dosimetric accuracy of the TPS for open fields within the specified tolerance limits. However large square (25cm x 25cm) and rectangular fields (20cm x 5cm) some points were out of tolerance in penumbra region (11.38 % and 10.9 %, respectively). For the test of SSD variation, the large field resulted from SSD 125 cm for 10cm x 10cm filed the results recorded an error of 0.2% at the central axis and 1.01% in penumbra. The results yielded differences within the accepted tolerance level as recommended. Large fields showed variations in penumbra. These differences between dose values predicted by the TPS and the measured values at the same point may result from limitations of the dose calculation, uncertainties in the measurement procedure, or fluctuations in the output of the accelerator. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=quality%20assurance" title="quality assurance">quality assurance</a>, <a href="https://publications.waset.org/abstracts/search?q=dose%20calculation" title=" dose calculation"> dose calculation</a>, <a href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning%20system" title=" 3D treatment planning system"> 3D treatment planning system</a>, <a href="https://publications.waset.org/abstracts/search?q=photon%20beam" title=" photon beam"> photon beam</a> </p> <a href="https://publications.waset.org/abstracts/11429/open-fields-dosimetric-verification-for-a-commercially-used-3d-treatment-planning-system" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/11429.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">517</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11404</span> Systematic Approach for Energy-Supply-Orientated Production Planning</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=F.%20Keller">F. Keller</a>, <a href="https://publications.waset.org/abstracts/search?q=G.%20Reinhart"> G. Reinhart</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The efficient and economic allocation of resources is one main goal in the field of production planning and control. Nowadays, a new variable gains in importance throughout the planning process: Energy. Energy-efficiency has already been widely discussed in literature, but with a strong focus on reducing the overall amount of energy used in production. This paper provides a brief systematic approach, how energy-supply-orientation can be used for an energy-cost-efficient production planning and thus combining the idea of energy-efficiency and energy-flexibility. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=production%20planning" title="production planning">production planning</a>, <a href="https://publications.waset.org/abstracts/search?q=production%20control" title=" production control"> production control</a>, <a href="https://publications.waset.org/abstracts/search?q=energy-efficiency" title=" energy-efficiency"> energy-efficiency</a>, <a href="https://publications.waset.org/abstracts/search?q=energy-flexibility" title=" energy-flexibility"> energy-flexibility</a>, <a href="https://publications.waset.org/abstracts/search?q=energy-supply" title=" energy-supply"> energy-supply</a> </p> <a href="https://publications.waset.org/abstracts/26038/systematic-approach-for-energy-supply-orientated-production-planning" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/26038.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">648</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11403</span> Analysis of Risk-Based Disaster Planning in Local Communities</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=R.%20A.%20Temah">R. A. Temah</a>, <a href="https://publications.waset.org/abstracts/search?q=L.%20A.%20Nkengla-Asi"> L. A. Nkengla-Asi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Planning for future disasters sets the stage for a variety of activities that may trigger multiple recurring operations and expose the community to opportunities to minimize risks. Local communities are increasingly embracing the necessity for planning based on local risks, but are also significantly challenged to effectively plan and response to disasters. This research examines basic risk-based disaster planning model and compares it with advanced risk-based planning that introduces the identification and alignment of varieties of local capabilities within and out of the local community that can be pivotal to facilitate the management of local risks and cascading effects prior to a disaster. A critical review shows that the identification and alignment of capabilities can potentially enhance risk-based disaster planning. A tailored holistic approach to risk based disaster planning is pivotal to enhance collective action and a reduction in disaster collective cost<em>.</em> <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=capabilities" title="capabilities">capabilities</a>, <a href="https://publications.waset.org/abstracts/search?q=disaster%20planning" title=" disaster planning"> disaster planning</a>, <a href="https://publications.waset.org/abstracts/search?q=hazards" title=" hazards"> hazards</a>, <a href="https://publications.waset.org/abstracts/search?q=local%20community" title=" local community"> local community</a>, <a href="https://publications.waset.org/abstracts/search?q=risk-based" title=" risk-based"> risk-based</a> </p> <a href="https://publications.waset.org/abstracts/103690/analysis-of-risk-based-disaster-planning-in-local-communities" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/103690.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">206</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">11402</span> Tourism Oriented Planning Experience in the Historical City Center of Trabzon (Turkey) with Strategic Spatial Planning Approach: Evaluation of Approach and Process</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Emrehan%20Ozcan">Emrehan Ozcan</a>, <a href="https://publications.waset.org/abstracts/search?q=Dilek%20Beyazl%C4%B1"> Dilek Beyazlı</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The development of tourism depends on an accurate planning approach as well as on the right planning process. This dependency is also a key factor in ensuring sustainability of tourism. The types of tourism, social expectations, planning practice, the socio-economic and the cultural structure of the region are determinants of planning approaches for tourism development. The tourism plans prepared for the historic city centers are usually based on the revitalization of cultural and historical values. The preservation and development of the tourism potentials of the historic city centers are important for providing an economic contribution to the locality, creating livable solutions for local residents and also the sustainability of tourism. This research is about experiencing and discussing a planning approach that will provide tourism development based on historical and cultural values. Historical and cultural values in the historical city center of Trabzon -which has a settlement history of approximately 4000 years, is located on the Black Sea coast of Turkey- wear out over years and lose their tourism potential. A planning study has been experienced with strategic spatial planning approach for Trabzon, which has not done a tourism-oriented planning study until now. The stages of the planning process provided by strategic spatial planning approach are an assessment of the current situation; vision, strategies, and actions; action planning; designing and implementation of actions and monitoring-evaluation. In the discussion section, the advantages, planning process, methods and techniques of the approach are discussed for the possibilities and constraints in terms of tourism planning. In this context, it is aimed to put forth tourism planning process, stages, and implementation tools within the scope of strategic spatial planning approach by comparing approaches used in the tourism-oriented/priority planning of historical city centers. Suggestions on the position and effect of the preferred planning approach in the existing spatial planning practice are the outputs of the study. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cultural%20heritage" title="cultural heritage">cultural heritage</a>, <a href="https://publications.waset.org/abstracts/search?q=tourism%20oriented%20planning" title=" tourism oriented planning"> tourism oriented planning</a>, <a href="https://publications.waset.org/abstracts/search?q=Trabzon" title=" Trabzon"> Trabzon</a>, <a href="https://publications.waset.org/abstracts/search?q=strategic%20spatial%20Planning" title=" strategic spatial Planning"> strategic spatial Planning</a> </p> <a href="https://publications.waset.org/abstracts/80244/tourism-oriented-planning-experience-in-the-historical-city-center-of-trabzon-turkey-with-strategic-spatial-planning-approach-evaluation-of-approach-and-process" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/80244.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">258</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">&lsaquo;</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=381">381</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=382">382</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=3D%20treatment%20planning&amp;page=2" rel="next">&rsaquo;</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">&copy; 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">&times;</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>

Pages: 1 2 3 4 5 6 7 8 9 10