CINXE.COM

Search results for: tendon transfer

<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: tendon transfer</title> <meta name="description" content="Search results for: tendon transfer"> <meta name="keywords" content="tendon transfer"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="tendon transfer" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="tendon transfer"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 2858</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: tendon transfer</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2858</span> An Inherent Risk to Damage the Popliteus Tendon by Some Femoral Component Designs: A Pilot Study in Indian Knees</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Rajendra%20Kanojia">Rajendra Kanojia</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Femoral components with inbuilt rotation require thicker flexion resection of the lateral femoral condyle and could potential risk to damage the popliteus tendon especially in the smaller Asian knees. We prospectively evaluated 10 patients with bilateral varus osteoarthritis knee to size the cuts and their location in relation to the popliteus tendon. Two different types of implant were used on either side, one side requires resection in 3° external rotation (group A) and other side femoral component with inbuilt external roation (group B). We had popliteus tendon injury in 3 knees all from group B. Risk of damaging the popliteus tendon was found higher in group B. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=popliteaus%20tendon%20injury" title="popliteaus tendon injury">popliteaus tendon injury</a>, <a href="https://publications.waset.org/abstracts/search?q=TKA" title=" TKA"> TKA</a>, <a href="https://publications.waset.org/abstracts/search?q=orthopaedic%20surgery" title=" orthopaedic surgery"> orthopaedic surgery</a>, <a href="https://publications.waset.org/abstracts/search?q=biomechanics%20and%20clinical%20applications" title=" biomechanics and clinical applications"> biomechanics and clinical applications</a> </p> <a href="https://publications.waset.org/abstracts/19811/an-inherent-risk-to-damage-the-popliteus-tendon-by-some-femoral-component-designs-a-pilot-study-in-indian-knees" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/19811.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">334</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2857</span> A Fundamental Study on the Anchor Performance of Non-Surface Treated Multi CFRP Tendons</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Woo-tai%20Jung">Woo-tai Jung</a>, <a href="https://publications.waset.org/abstracts/search?q=Jong-sup%20Park"> Jong-sup Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Jae-yoon%20Kang"> Jae-yoon Kang</a>, <a href="https://publications.waset.org/abstracts/search?q=Moon-seoung%20Keum"> Moon-seoung Keum</a> </p> <p class="card-text"><strong>Abstract:</strong></p> CFRP (Carbon Fiber Reinforced Polymer) is mainly used as reinforcing material for degraded structures owing to its advantages including its non-corrodibility, high strength, and lightweight properties. Recently, dedicated studies focused not only on its simple bonding but also on its tensioning. The tension necessary for prestressing requires the anchoring of multi-CFRP tendons with high capacity and the surface treatment of the CFRP tendons may also constitute an important issue according to the type of anchor. The wedge type, swage type or bonded type anchor can be used to anchor the CFRP tendon. The bonded type anchor presents the disadvantage to lengthen the length of the anchor due to the low bond strength of the CFRP tendon without surface treatment. This study intends to overcome this drawback through the application of a method enlarging the bond area at the end of the CFRP tendon. This method enlarges the bond area by splitting the end of the CFRP tendon along its length and can be applied when CFRP is produced by pultrusion. The application of this method shows that the mono-CFRP tendon and 3-multi CFRP tendon secured the anchor performance corresponding to the tensile performance of the CFRP tendon and that the 7-multi tendon secured anchor performance corresponding to 90% of the tensile strength due to the occurrence of buckling in the steel tube anchorage. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=carbon%20fiber%20reinforced%20polymer%20%28CFRP%29" title="carbon fiber reinforced polymer (CFRP)">carbon fiber reinforced polymer (CFRP)</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=anchor" title=" anchor"> anchor</a>, <a href="https://publications.waset.org/abstracts/search?q=tensile%20property" title=" tensile property"> tensile property</a>, <a href="https://publications.waset.org/abstracts/search?q=bond%20strength" title=" bond strength"> bond strength</a> </p> <a href="https://publications.waset.org/abstracts/1828/a-fundamental-study-on-the-anchor-performance-of-non-surface-treated-multi-cfrp-tendons" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/1828.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">247</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2856</span> Glenoid Osteotomy with Various Tendon Transfers for Brachial Plexus Birth Palsy: Clinical Outcomes</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ramin%20Zargarbashi">Ramin Zargarbashi</a>, <a href="https://publications.waset.org/abstracts/search?q=Hamid%20Rabie"> Hamid Rabie</a>, <a href="https://publications.waset.org/abstracts/search?q=Behnam%20Panjavi"> Behnam Panjavi</a>, <a href="https://publications.waset.org/abstracts/search?q=Hooman%20Kamran"> Hooman Kamran</a>, <a href="https://publications.waset.org/abstracts/search?q=Seyedarad%20Mosalamiaghili"> Seyedarad Mosalamiaghili</a>, <a href="https://publications.waset.org/abstracts/search?q=Zohre%20Erfani"> Zohre Erfani</a>, <a href="https://publications.waset.org/abstracts/search?q=Seyed%20Peyman%20Mirghaderi"> Seyed Peyman Mirghaderi</a>, <a href="https://publications.waset.org/abstracts/search?q=Maryam%20Salimi"> Maryam Salimi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Posterior shoulder dislocation is one of the disabling complications of brachial plexus birth injury (BPBI), and various treatment options, including capsule and surrounding muscles release for open reduction, humeral derotational osteotomy, and tendon transfers, have been recommended to manage it. In the present study, we aimed to determine the clinical outcome of open reduction with soft tissue release, tendon transfer, and glenoid osteotomy inpatients with BPBI and posterior shoulder dislocation or subluxation. Methods: From 2018 to 2020, 33 patients that underwent open reduction, glenoid osteotomy, and tendon transfer were included. The glenohumeral deformity was classified according to the Waters radiographic classification. Functional assessment was performed using the Mallet grading system before and at least two years after the surgery. Results: The patients were monitored for 26.88± 5.47 months. Their average age was 27.5±14 months. Significant improvement was seen in the overall Mallet score (from 13.5 to 18.91 points) and its segments, including hand to mouth, hand to the neck, global abduction, global external rotation, abduction degree, and external rotation degree. Hand-to-back score and the presence of trumpet sign were significantly decreased in the post-operation phase (all p values<0.001). The above-mentioned variables significantly changed for both infantile and non-infantile dislocations. Conclusion: Our study demonstrated that open reduction along with glenoid osteotomy improves retroversion, and muscle strengthening with different muscle transfers is an effective technique for BPBI. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=birth%20injuries" title="birth injuries">birth injuries</a>, <a href="https://publications.waset.org/abstracts/search?q=nerve%20injury" title=" nerve injury"> nerve injury</a>, <a href="https://publications.waset.org/abstracts/search?q=brachial%20plexus%20birth%20palsy" title=" brachial plexus birth palsy"> brachial plexus birth palsy</a>, <a href="https://publications.waset.org/abstracts/search?q=Erb%20palsy" title=" Erb palsy"> Erb palsy</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon%20transfer" title=" tendon transfer"> tendon transfer</a> </p> <a href="https://publications.waset.org/abstracts/154524/glenoid-osteotomy-with-various-tendon-transfers-for-brachial-plexus-birth-palsy-clinical-outcomes" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/154524.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">96</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2855</span> Modified Tendon Model Considered Structural Nonlinearity in PSC Structures</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Yangsu%20Kwon">Yangsu Kwon</a>, <a href="https://publications.waset.org/abstracts/search?q=Hyo-Gyoung%20Kwak"> Hyo-Gyoung Kwak</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Nonlinear tendon constitutive model for nonlinear analysis of pre-stressed concrete structures are presented. Since the post-cracking behavior of concrete structures, in which bonded reinforcements such as tendons and/or reinforcing steels are embedded, depends on many influencing factors(the tensile strength of concrete, anchorage length of reinforcements, concrete cover, and steel spacing) that are deeply related to the bond characteristics between concrete and reinforcements, consideration of the tension stiffening effect on the basis of the bond-slip mechanism is necessary to evaluate ultimate resisting capacity of structures. In this paper, an improved tendon model, which considering the slip effect between concrete and tendon, and effect of tension stiffening, is suggested. The validity of the proposed models is established by comparing between the analytical results and experimental results in pre-stressed concrete beams. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=bond-slip" title="bond-slip">bond-slip</a>, <a href="https://publications.waset.org/abstracts/search?q=prestressed%20concrete" title=" prestressed concrete"> prestressed concrete</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=ultimate%20strength" title=" ultimate strength"> ultimate strength</a> </p> <a href="https://publications.waset.org/abstracts/17409/modified-tendon-model-considered-structural-nonlinearity-in-psc-structures" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/17409.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">493</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2854</span> Mouse Knockouts for Elucidating the Role of Cysteine-Rich Angiogenic Inducer 61 in Tendon Development and Maintenance</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Josephine%20Hai">Josephine Hai</a>, <a href="https://publications.waset.org/abstracts/search?q=Jie%20Jiang"> Jie Jiang</a>, <a href="https://publications.waset.org/abstracts/search?q=Karen%20M.%20Lyons"> Karen M. Lyons</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Of the musculoskeletal tissues, tendon is least understood in terms of biological development. The current study examines Cysteine-rich angiogenic inducer 61, or CCN1, a member of the CCN family of secreted matricellular proteins that regulate cell behavior via intercellular signaling. Though CCN1 is notable in limiting fibrosis by inducing senescence in fibroblasts, little is known about its role in normal fibrous tissue, where it may be essential to the development of ECM-rich structures like tendons. We found that CCN1 knockout mice (using limb-specific Prx1-Cre) exhibited clubfoot and waddling gaits, a unique phenotype not described in any other mutant to date. Histological analysis showed that the Achilles and patellar tendons, where we previously found high CCN1 expression in adult reporter mice, were thicker and denser in the Prx1-Cre knockouts than in their wildtype littermates. We then hypothesized that CCN1 is required directly in tendon progenitor cells for normal tendon development and generated tendon-specific CCN1 knockout mice using Scx-Cre. We observed similar Achilles/patellar tendon morphology among the Scx-Cre and Prx1-Cre mutants, indicating that the phenotype is a direct result of CCN1’s loss in tendon. To further study phenotype onset and progression, we will histologically characterize these tendons across different developmental time-points. We will also perform RNA-seq and qPCR to analyze tenocyte gene expression and expect fibrotic marker upregulation in the Scx-Cre mutants if CCN1 is required to maintain a normal tendon phenotype. Thus, our study aims to elucidate the molecular mechanisms underlying tendon formation and maintenance. Understanding tendons at the most basic level invites novel approaches to tendon repair. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=development" title="development">development</a>, <a href="https://publications.waset.org/abstracts/search?q=matricellular" title=" matricellular"> matricellular</a>, <a href="https://publications.waset.org/abstracts/search?q=musculoskeletal" title=" musculoskeletal"> musculoskeletal</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a> </p> <a href="https://publications.waset.org/abstracts/94497/mouse-knockouts-for-elucidating-the-role-of-cysteine-rich-angiogenic-inducer-61-in-tendon-development-and-maintenance" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/94497.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">181</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2853</span> A Study of Influence of Freezing on Mechanical Properties of Tendon Fascicles </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Martyna%20Ekiert">Martyna Ekiert</a>, <a href="https://publications.waset.org/abstracts/search?q=Andrzej%20Mlyniec"> Andrzej Mlyniec</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Tendons are the biological structures, which primary function is to transfer force generated by muscles to the bones. Unfortunately, damages of tendons are also one of the most common injuries of the human musculoskeletal system. For the most severe cases of tendon rupture, such as the tear of calcaneus tendon or anterior cruciate ligament of the knee, a surgical procedure is the only possible way of full recovery. Tendons used as biological grafts are usually subjected to the process of deep freezing and subsequent thawing. This, in particular for multiple freezing/thawing cycles, may result in changes of tendon internal structure causing deterioration of mechanical properties of the tissue. Therefore, studies on the influence of freezing on tendons biomechanics, including internal water content in soft tissue, seems to be greatly needed. An experimental study of the influence of freezing on mechanical properties of the tendon was performed on fascicles samples dissected form bovine flexor tendons. The preparation procedure was performed with the presence of 0.9% saline solution in order to prevent an excessive tissue drying. All prepared samples were subjected to the different number of freezing/thawing cycles. For freezing part of the protocol we used -80°C temperature while for slow thawing we used fridge temperature (4°C) combined with equalizing temperatures in the standard state (25°C). After final thawing, the mechanical properties of each sample was examined using cyclic loading test. Our results may contribute for better understanding of negative effects of soft tissues freezing, resulting from abnormal thermal expansion of water. This also may help to determine the limit of freezing/thawing cycles disqualifying tissue for surgical purposes and thus help optimize tissues storage conditions. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=freezing" title="freezing">freezing</a>, <a href="https://publications.waset.org/abstracts/search?q=soft%20tissue" title=" soft tissue"> soft tissue</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=bovine%20fascicles" title=" bovine fascicles"> bovine fascicles</a> </p> <a href="https://publications.waset.org/abstracts/91166/a-study-of-influence-of-freezing-on-mechanical-properties-of-tendon-fascicles" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/91166.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">219</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2852</span> Effect of Two Bouts of Eccentric Exercise on Knee Flexors Changes in Muscle-Tendon Lengths</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Shang-Hen%20Wu">Shang-Hen Wu</a>, <a href="https://publications.waset.org/abstracts/search?q=Yung-Chen%20Lin"> Yung-Chen Lin</a>, <a href="https://publications.waset.org/abstracts/search?q=Wei-Song%20Chang"> Wei-Song Chang</a>, <a href="https://publications.waset.org/abstracts/search?q=Ming-Ju%20Lin"> Ming-Ju Lin</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study investigated whether the repeated bout effect (RBE) of knee flexors (KF) eccentric exercise would be changed in muscle-tendon lengths. Eight healthy university male students used their KF of non-dominant leg and performed a bout of 60 maximal isokinetic (30°/s) eccentric contractions (MaxECC1). A week after MaxECC1, all subjects used the same KF to perform a subsequent bout of MaxECC2. Changes in maximal isokinetic voluntary contraction torque (MVC-CON), muscle soreness (SOR), relaxed knee joint angle (RANG), leg circumference (CIR), and ultrasound images (UI; muscle-tendon length and muscle angle) were measured before, immediately after, 1-5 days after each bout. Two-way ANOVA was used to analyze all the dependent variables. After MaxECC1, all the dependent variables (e.g. MVC-CON: ↓30%, muscle-tendon length: ↑24%, muscle angle: ↑15%) showed significantly change. Following MaxECC2, all the above dependent variables (e.g. MVC-CON:↓21%, tendon length: ↑16%, muscle angle: ↑6%) were significantly smaller than those of MaxECC1. These results of this study found that protective effect conferred by MaxECC1 against MaxECC2, and changes in muscle damage indicators, muscle-tendon length and muscle angle following MaxECC2 were smaller than MaxECC1. Thus, the amount of shift of muscle-tendon length and muscle angle was related to the RBE. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=eccentric%20exercise" title="eccentric exercise">eccentric exercise</a>, <a href="https://publications.waset.org/abstracts/search?q=maximal%20isokinetic%20voluntary%20contraction%20torque" title=" maximal isokinetic voluntary contraction torque"> maximal isokinetic voluntary contraction torque</a>, <a href="https://publications.waset.org/abstracts/search?q=repeated%20bout%20effect" title=" repeated bout effect"> repeated bout effect</a>, <a href="https://publications.waset.org/abstracts/search?q=ultrasound" title=" ultrasound"> ultrasound</a> </p> <a href="https://publications.waset.org/abstracts/70166/effect-of-two-bouts-of-eccentric-exercise-on-knee-flexors-changes-in-muscle-tendon-lengths" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/70166.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">331</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2851</span> Tensile Test of Corroded Strand and Maintenance of Corroded Prestressed Concrete Girders</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jeon%20Chi-Ho">Jeon Chi-Ho</a>, <a href="https://publications.waset.org/abstracts/search?q=Lee%20Jae-Bin"> Lee Jae-Bin</a>, <a href="https://publications.waset.org/abstracts/search?q=Shim%20Chang-Su"> Shim Chang-Su</a> </p> <p class="card-text"><strong>Abstract:</strong></p> National bridge inventory in Korea shows that the number of old prestressed concrete (PSC) bridgeover 30 years of service life is rapidly increasing. Recently tendon corrosion is one of the most critical issues in the maintenance of PSC bridges. In this paper, mechanical properties of corroded strands, which were removed from old bridges, were evaluated using tensile test. In the result, the equations to express the mechanical behavior of corroded strand were derived and compared to existing equation. For the decision of tendon replacement, it is necessary to evaluate the effect of corrosion level on strength and ductility of the structure. Considerations on analysis of PSC girders were introduced, and decision making on tendon replacement was also proposed. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=prestressed%20concrete%20bridge" title="prestressed concrete bridge">prestressed concrete bridge</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=corrosion" title=" corrosion"> corrosion</a>, <a href="https://publications.waset.org/abstracts/search?q=strength" title=" strength"> strength</a>, <a href="https://publications.waset.org/abstracts/search?q=ductility" title=" ductility"> ductility</a> </p> <a href="https://publications.waset.org/abstracts/80108/tensile-test-of-corroded-strand-and-maintenance-of-corroded-prestressed-concrete-girders" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/80108.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">256</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2850</span> The Tendon Reflexes on the Performance of Flanker Task in the Subjects of Cerebrovascular Accidents</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Harshdeep%20Singh">Harshdeep Singh</a>, <a href="https://publications.waset.org/abstracts/search?q=Kuljeet%20Singh%20Anand"> Kuljeet Singh Anand</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Cerebrovascular Accidents (CVA) cause abnormal or asymmetrical tendon reflexes contributing to motor impairments. Since the tendon reflexes are mediated by the spinal cord, their effects on cognitive performances are overlooked. This study aims to find the contributions of tendon reflexes on the performance of the Flanker task. Methods: A total population of 46 mixed subjects with movement disorders were recruited for the study. Deep tendon reflexes (DTR) of the biceps, triceps and brachioradialis were assessed for both upper extremities. Later, the Flanker task was performed on all the subjects, and the mean Reaction Time (RT) along with both the congruent and incongruent stimuli were evaluated. For the final analysis, the Kruskal Wallis test was performed to see the difference between the DTR and the performance of the Flanker Task. Results: The Kruskal Wallis test results showed a significant difference between the DTR scores, X²(2) = 11.328, p= 0.023 with the mean RT of the flanker task and X²(2) = 9.531, p= 0.049 with mean RT of the Incongruent Stimuli. Whereas the result found a non-significant difference in the mean RT of the Congruent Stimuli. Conclusion: Each DTR score is distributed differently with the mean RT of the flanker task and for the incongruent stimuli as well. Therefore, the tendon reflexes in PD may be contributing to the performance of the Flanker Task and may be an indicator of abnormal cognitive performance. Further research is needed to evaluate how the RTs are distributed with each DTR score. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cerebrovascular%20accidents" title="cerebrovascular accidents">cerebrovascular accidents</a>, <a href="https://publications.waset.org/abstracts/search?q=deep%20tendon%20reflexes" title=" deep tendon reflexes"> deep tendon reflexes</a>, <a href="https://publications.waset.org/abstracts/search?q=flanker%20task" title=" flanker task"> flanker task</a>, <a href="https://publications.waset.org/abstracts/search?q=reaction%20time" title=" reaction time"> reaction time</a>, <a href="https://publications.waset.org/abstracts/search?q=congruent%20stimuli" title=" congruent stimuli"> congruent stimuli</a>, <a href="https://publications.waset.org/abstracts/search?q=incongruent%20stimuli" title=" incongruent stimuli"> incongruent stimuli</a> </p> <a href="https://publications.waset.org/abstracts/162752/the-tendon-reflexes-on-the-performance-of-flanker-task-in-the-subjects-of-cerebrovascular-accidents" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/162752.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">102</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2849</span> Increasing Access to Upper Limb Reconstruction in Cervical Spinal Cord Injury</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Michelle%20Jennett">Michelle Jennett</a>, <a href="https://publications.waset.org/abstracts/search?q=Jana%20Dengler"> Jana Dengler</a>, <a href="https://publications.waset.org/abstracts/search?q=Maytal%20Perlman"> Maytal Perlman</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Cervical spinal cord injury (SCI) is a devastating event that results in upper limb paralysis, loss of independence, and disability. People living with cervical SCI have identified improvement of upper limb function as a top priority. Nerve and tendon transfer surgery has successfully restored upper limb function in cervical SCI but is not universally used or available to all eligible individuals. This exploratory mixed-methods study used an implementation science approach to better understand these factors that influence access to upper limb reconstruction in the Canadian context and design an intervention to increase access to care. Methods: Data from the Canadian Institute for Health Information’s Discharge Abstracts Database (CIHI-DAD) and the National Ambulatory Care Reporting System (NACRS) were used to determine the annual rate of nerve transfer and tendon transfer surgeries performed in cervical SCI in Canada over the last 15 years. Semi-structured interviews informed by the consolidated framework for implementation research (CFIR) were used to explore Ontario healthcare provider knowledge and practices around upper limb reconstruction. An inductive, iterative constant comparative process involving descriptive and interpretive analyses was used to identify themes that emerged from the data. Results: Healthcare providers (n = 10 upper extremity surgeons, n = 10 SCI physiatrists, n = 12 physical and occupational therapists working with individuals with SCI) were interviewed about their knowledge and perceptions of upper limb reconstruction and their current practices and discussions around upper limb reconstruction. Data analysis is currently underway and will be presented. Regional variation in rates of upper limb reconstruction and trends over time are also currently being analyzed. Conclusions: Utilization of nerve and tendon transfer surgery to improve upper limb reconstruction in Canada remains low. There are a complex array of interrelated individual-, provider- and system-level barriers that prevent individuals with cervical SCI from accessing upper limb reconstruction. In order to offer equitable access to care, a multi-modal approach addressing current barriers is required. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cervical%20spinal%20cord%20injury" title="cervical spinal cord injury">cervical spinal cord injury</a>, <a href="https://publications.waset.org/abstracts/search?q=nerve%20and%20tendon%20transfer%20surgery" title=" nerve and tendon transfer surgery"> nerve and tendon transfer surgery</a>, <a href="https://publications.waset.org/abstracts/search?q=spinal%20cord%20injury" title=" spinal cord injury"> spinal cord injury</a>, <a href="https://publications.waset.org/abstracts/search?q=upper%20extremity%20reconstruction" title=" upper extremity reconstruction"> upper extremity reconstruction</a> </p> <a href="https://publications.waset.org/abstracts/137972/increasing-access-to-upper-limb-reconstruction-in-cervical-spinal-cord-injury" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/137972.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">97</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2848</span> Efficacy of Light-Emitting Diode-Mediated Photobiomodulation in Tendon Healing in a Murine Model</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sukwoong%20Kang">Sukwoong Kang</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: The application of light-emitting diode (LED)-dependent photobiomodulation (PBM) in promoting post-tendon injury healing has been recently reported. Despite the establishment of a theoretical basis for ligament restoration through PBM, the lack of any empirical evidence deems this therapeutic strategy contentious. Therefore, the aim of this study was to investigate the potency of LED-based PBM in facilitating tendon healing in a murine model. Methods: Migration kinetics were analyzed at two specific wavelengths: 630 and 880 nm. The Achilles tendon in the hind limbs of Balb/c mice was severed via Achilles tendon transection. Subsequently, the mice were randomized into LED non-irradiation and LED irradiation groups. Mice with intact tendons were employed as healthy controls. The wounds were LED-irradiated for 20 min daily for two days. Histological properties, tendon healing mediators, and inflammatory mediators were screened on day 14. Results: The roundness of the nuclei and fiber structure, indicating the degree of infiltrated inflammatory cells and severity of fiber fragmentation, respectively, were considerably lower in the LED irradiation group than in the LED non-irradiation group. Immunohistochemical analysis depicted an increase in tenocytes (SCX+ cells) and a recovery of wounds with reduced fibrosis (lower collagen 3 and TGF-β1) in the LED irradiation group during healing; conversely, the LED non-irradiation group exhibited tissue fibrosis. The ratio of M2 macrophages to total macrophages was higher in the LED irradiation group than in the injured group. Conclusion: LED-based PBM in the Achilles tendon rupture murine model effectuated a rapid restoration of histological and immunochemical outcomes. The aforementioned findings suggest that LED-based PBM presents remarkable potential as an adjunct therapeutic for tendon healing and warrants further research to standardize various parameters to advance and establish it as a reliable treatment regime. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=photobiomodulation" title="photobiomodulation">photobiomodulation</a>, <a href="https://publications.waset.org/abstracts/search?q=light-emitting%20diode" title=" light-emitting diode"> light-emitting diode</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=regeneration" title=" regeneration"> regeneration</a> </p> <a href="https://publications.waset.org/abstracts/185349/efficacy-of-light-emitting-diode-mediated-photobiomodulation-in-tendon-healing-in-a-murine-model" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/185349.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">44</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2847</span> Operative Technique of Glenoid Anteversion Osteotomy and Soft Tissue Rebalancing for Brachial Plexus Birth Palsy</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Michael%20Zaidman">Michael Zaidman</a>, <a href="https://publications.waset.org/abstracts/search?q=Naum%20Simanovsky"> Naum Simanovsky</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The most of brachial birth palsies are transient. Children with incomplete recovery almost always develop an internal rotation and adduction contracture. The muscle imbalance around the shoulder results in glenohumeral joint deformity and functional limitations. Natural history of glenohumeral deformity is it’s progression with worsening of function. Anteversion glenoid osteotomy with latissimus dorsi and teres major tendon transfers could be an alternative procedure of proximal humeral external rotation osteotomy for patients with severe glenohumeral dysplasia secondary to brachial plexus birth palsy. We will discuss pre-operative planning and stepped operative technique of the procedure on clinical example. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=obstetric%20brachial%20plexus%20palsy" title="obstetric brachial plexus palsy">obstetric brachial plexus palsy</a>, <a href="https://publications.waset.org/abstracts/search?q=glenoid%20anteversion%20osteotomy" title=" glenoid anteversion osteotomy"> glenoid anteversion osteotomy</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon%20transfer" title=" tendon transfer"> tendon transfer</a>, <a href="https://publications.waset.org/abstracts/search?q=operative%20technique" title=" operative technique"> operative technique</a> </p> <a href="https://publications.waset.org/abstracts/174911/operative-technique-of-glenoid-anteversion-osteotomy-and-soft-tissue-rebalancing-for-brachial-plexus-birth-palsy" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/174911.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">73</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2846</span> A Hyperflexion Hallux Mallet Injury: A Case Report</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Tan%20G.%20K.%20Y.">Tan G. K. Y.</a>, <a href="https://publications.waset.org/abstracts/search?q=Chew%20M.%20S.%20J."> Chew M. S. J.</a>, <a href="https://publications.waset.org/abstracts/search?q=Sajeev%20S."> Sajeev S.</a>, <a href="https://publications.waset.org/abstracts/search?q=Vellasamy%20A."> Vellasamy A.</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Injuries of the extensor hallucis longus (EHL) tendon are a rare phenomenon, with most occurring due to lacerations or penetrating injuries. Closed traumatic ruptures of the EHL are described as “Mallet injuries of the toe”. These can be classified as bony or soft mallet injuries depending on the presence or absence of a fracture at the insertion site of the EHL tendon in the distal phalanx. We present a case of a 33-year-old woman who presented with a hyperflexion injury to the left big toe with an inability to extend the big toe. Ultrasound showed a complete rupture of the EHL tendon with retraction proximal to the hallucal interphalangeal joint of the big toe. The patient was treated through transarticular pinning and repair using the Arthrex Mini Bio-Suture Tak with a 2-0 fibre wire. Six months postoperatively, the patient had symmetrical EHL power and full range of motion of the toe. The lessons to be drawn from this case report are that isolated hallux mallet injuries are rare and can be easily missed in the absence of penetrating wounds. Patients who have such injuries should be investigated early with the appropriate imaging techniques, such as ultrasound or MRI, and treated surgically. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hallux%20mallet" title="hallux mallet">hallux mallet</a>, <a href="https://publications.waset.org/abstracts/search?q=extensor%20hallucis%20longus%20tendon" title=" extensor hallucis longus tendon"> extensor hallucis longus tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=extensor%20hallucis%20longus" title=" extensor hallucis longus"> extensor hallucis longus</a> </p> <a href="https://publications.waset.org/abstracts/174228/a-hyperflexion-hallux-mallet-injury-a-case-report" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/174228.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">79</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2845</span> The Acute Effects of Higher Versus Lower Load Duration and Intensity on Morphological and Mechanical Properties of the Healthy Achilles Tendon: A Randomized Crossover Trial</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Eman%20Merza">Eman Merza</a>, <a href="https://publications.waset.org/abstracts/search?q=Stephen%20Pearson"> Stephen Pearson</a>, <a href="https://publications.waset.org/abstracts/search?q=Glen%20Lichtwark"> Glen Lichtwark</a>, <a href="https://publications.waset.org/abstracts/search?q=Peter%20Malliaras"> Peter Malliaras</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The Achilles tendon (AT) exhibits volume changes related to fluid flow under acute load which may be linked to changes in stiffness. Fluid flow provides a mechanical signal for cellular activity and may be one mechanism that facilitates tendon adaptation. This study aimed to investigate whether isometric intervention involving a high level of load duration and intensity could maximize the immediate reduction in AT volume and stiffness compared to interventions involving a lower level of load duration and intensity. Sixteen healthy participants (12 males, 4 females; age= 24.4 ± 9.4 years; body mass= 70.9 ± 16.1 kg; height= 1.7 ± 0.1 m) performed three isometric interventions of varying levels of load duration (2 s and 8 s) and intensity (35% and 75% maximal voluntary isometric contraction) over a 3 week period. Freehand 3D ultrasound was used to measure free AT volume (at rest) and length (at 35%, 55%, and 75% of maximum plantarflexion force) pre- and post-interventions. The slope of the force-elongation curve over these force levels represented individual stiffness (N/mm). Large reductions in free AT volume and stiffness resulted in response to long-duration high-intensity loading whilst less reduction was produced with a lower load intensity. In contrast, no change in free AT volume and a small increase in AT stiffness occurred with lower load duration. These findings suggest that the applied load on the AT must be heavy and sustained for a long duration to maximize immediate volume reduction, which might be an acute response that enables optimal long-term tendon adaptation via mechanotransduction pathways. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Achilles%20tendon" title="Achilles tendon">Achilles tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=volume" title=" volume"> volume</a>, <a href="https://publications.waset.org/abstracts/search?q=stiffness" title=" stiffness"> stiffness</a>, <a href="https://publications.waset.org/abstracts/search?q=free%20tendon" title=" free tendon"> free tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=3d%20ultrasound" title=" 3d ultrasound"> 3d ultrasound</a> </p> <a href="https://publications.waset.org/abstracts/161744/the-acute-effects-of-higher-versus-lower-load-duration-and-intensity-on-morphological-and-mechanical-properties-of-the-healthy-achilles-tendon-a-randomized-crossover-trial" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/161744.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">99</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2844</span> Magnetic Resonance Imaging for Assessment of the Quadriceps Tendon Cross-Sectional Area as an Adjunctive Diagnostic Parameter in Patients with Patellofemoral Pain Syndrome</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jae%20Ni%20Jang">Jae Ni Jang</a>, <a href="https://publications.waset.org/abstracts/search?q=SoYoon%20Park"> SoYoon Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Sukhee%20Park"> Sukhee Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Yumin%20Song"> Yumin Song</a>, <a href="https://publications.waset.org/abstracts/search?q=Jae%20Won%20Kim"> Jae Won Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Keum%20Nae%20Kang"> Keum Nae Kang</a>, <a href="https://publications.waset.org/abstracts/search?q=Young%20Uk%20Kim"> Young Uk Kim</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Objectives: Patellofemoral pain syndrome (PFPS) is a common clinical condition characterized by anterior knee pain. Here, we investigated the quadriceps tendon cross-sectional area (QTCSA) as a novel predictor for the diagnosis of PFPS. By examining the association between the QTCSA and PFPS, we aimed to provide a more valuable diagnostic parameter and more equivocal assessment of the diagnostic potential of PFPS by comparing the QTCSA with the quadriceps tendon thickness (QTT), a traditional measure of quadriceps tendon hypertrophy. Patients and Methods: This retrospective study included 30 patients with PFPS and 30 healthy participants who underwent knee magnetic resonance imaging. T1-weighted turbo spin echo transverse magnetic resonance images were obtained. The QTCSA was measured on the axial-angled phases of the images by drawing outlines, and the QTT was measured at the most hypertrophied quadriceps tendon. Results: The average QTT and QTCSA for patients with PFPS (6.33±0.80 mm and 155.77±36.60 mm², respectively) were significantly greater than those for healthy participants (5.77±0.36 mm and 111.90±24.10 mm2, respectively; both P<0.001). We used a receiver operating characteristic curve to confirm the sensitivities and specificities for both the QTT and QTCSA as predictors of PFPS. The optimal diagnostic cutoff value for QTT was 5.98 mm, with a sensitivity of 66.7%, a specificity of 70.0%, and an area under the curve of 0.75 (0.62–0.88). The optimal diagnostic cutoff value for QTCSA was 121.04 mm², with a sensitivity of 73.3%, a specificity of 70.0%, and an area under the curve of 0.83 (0.74–0.93). Conclusion: The QTCSA was found to be a more reliable diagnostic indicator for PFPS than QTT. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=patellofemoral%20pain%20syndrome" title="patellofemoral pain syndrome">patellofemoral pain syndrome</a>, <a href="https://publications.waset.org/abstracts/search?q=quadriceps%20muscle" title=" quadriceps muscle"> quadriceps muscle</a>, <a href="https://publications.waset.org/abstracts/search?q=hypertrophy" title=" hypertrophy"> hypertrophy</a>, <a href="https://publications.waset.org/abstracts/search?q=magnetic%20resonance%20imaging" title=" magnetic resonance imaging"> magnetic resonance imaging</a> </p> <a href="https://publications.waset.org/abstracts/186367/magnetic-resonance-imaging-for-assessment-of-the-quadriceps-tendon-cross-sectional-area-as-an-adjunctive-diagnostic-parameter-in-patients-with-patellofemoral-pain-syndrome" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/186367.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">50</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2843</span> Simultaneous Bilateral Patella Tendon Rupture: A Systematic Review</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Andr%C3%A9%20Rui%20Coelho%20Fernandes">André Rui Coelho Fernandes</a>, <a href="https://publications.waset.org/abstracts/search?q=Mariana%20Rufino"> Mariana Rufino</a>, <a href="https://publications.waset.org/abstracts/search?q=Divakar%20Hamal"> Divakar Hamal</a>, <a href="https://publications.waset.org/abstracts/search?q=Amr%20Sousa"> Amr Sousa</a>, <a href="https://publications.waset.org/abstracts/search?q=Emma%20Fossett"> Emma Fossett</a>, <a href="https://publications.waset.org/abstracts/search?q=Kamalpreet%20Cheema"> Kamalpreet Cheema</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Aim: A single patella tendon rupture is relatively uncommon, but a simultaneous bilateral event is a rare occurrence and has been scarcely reviewed in the literature. This review was carried out to analyse the existing literature on this event, with the aim of proposing a standardised approach to the diagnosis and management of this injury. Methods: A systematic review was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Three independent reviewers conducted searches in PubMed, OvidSP for Medline and Embase, as well as Cochrane Library using the same search strategy. From a total of 183 studies, 45 were included, i.e. 90 patellas. Results: 46 patellas had a Type 1 Rupture equating to 51%, with Type 3 being the least common, with only 7 patellas sustaining this injury. The mean Insall-Salvio ratio for each knee was 1.62 (R) and 1.60 (L) Direct Primary Repair was the most common surgical technique compared to Tendon Reconstruction, with End to End and Transosseous techniques split almost equally. Brace immobilisation was preferred over cast, with a mean start to weight-bearing of 3.23 weeks post-op. Conclusions: Bilateral patellar tendon rupture is a rare injury that should be considered in patients with knee extensor mechanism disruption. The key limitation of this study was the low number of patients encompassed by the eligible literature. There is space for a higher level of evidence study, specifically regarding surgical treatment choice and methods, as well as post-operative management, which could potentially improve the outcomes in the management of this injury. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=trauma%20and%20orthopaedic%20surgery" title="trauma and orthopaedic surgery">trauma and orthopaedic surgery</a>, <a href="https://publications.waset.org/abstracts/search?q=bilateral%20patella" title=" bilateral patella"> bilateral patella</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon%20rupture" title=" tendon rupture"> tendon rupture</a>, <a href="https://publications.waset.org/abstracts/search?q=trauma" title=" trauma"> trauma</a> </p> <a href="https://publications.waset.org/abstracts/159750/simultaneous-bilateral-patella-tendon-rupture-a-systematic-review" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/159750.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">135</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2842</span> The Rupture of Tendon Achilles During the Recreative and Sports Activities</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jasmin%20S.%20Nurkovic">Jasmin S. Nurkovic</a>, <a href="https://publications.waset.org/abstracts/search?q=Ljubisa%20Dj.%20Jovasevic"> Ljubisa Dj. Jovasevic</a>, <a href="https://publications.waset.org/abstracts/search?q=Zana%20C.%20Dolicanin"> Zana C. Dolicanin</a>, <a href="https://publications.waset.org/abstracts/search?q=Zoran%20S.%20Bajin"> Zoran S. Bajin</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Ruptured muscles and tendons very often must be repatriated by open operation in young persons. In young, muscles are ruptured more often than tendons, at the sane time in older persons are more exposed to rupture than muscles. Ruptured of the calcaneus are the most present of all ruptures. Sometime the rupture is complete, but very often the incomplete rupture can be noticed. During six years, from 2006 to 2012, we treated nineteen male patients and three female patients with the rupture of tendon Achilles. The youngest patient was aged thirty two, and the oldest was also managed sixty four. The youngest female patient was forty one and the oldest was forty six. One of our patients who was under corticosteroid treatment did not take any part in sport activities but she was, as she told us, going for a long walk, the same was with other two patients one man and one woman. We had nineteen male patients age 32 to 64 and three female patients age 41, 44 and 46. Conservative treatment by cast was applied in five patients and very good results were in three of them. In two patients surgical treatment failed in patient’s age 53 and 64. Only one of all patients treated by surgery had healing problems because of necrotic changes of the skin where incision was made. One of our female patients age 45 was under steroid treatment for almost 20 years because of asthmatic problems. We suggested her wearing boots with 8cm long heels by day and by night eight weeks. The final results were satisfactory and all the time she was able to work and to walk. It was the only case we had with bilateral tendon rupture. After eight weeks the cast is removed and psychiatric treatment started, patient is using crutches with partial weight bearing over a period of two weeks. Quite the same treatment conservative treatment, only the cast is not removed after two but after four weeks. Everyday activities after the surgical treatment started ten weeks and sport activities can start after fourteen to sixteen weeks. An increased activity of our patient without previous preparing for forces activity can result, as we already see, with tendon rupture. Treatment is very long and very often surgical. We find that surgical treatment resulted as safer and better solution for patients. We also had a patient with spontaneous rupture of tendon during longer walking but this patient was under prolonged corticosteroid treatment. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=tendon" title="tendon">tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=Achilles" title=" Achilles"> Achilles</a>, <a href="https://publications.waset.org/abstracts/search?q=rupture" title=" rupture"> rupture</a>, <a href="https://publications.waset.org/abstracts/search?q=sport" title=" sport"> sport</a> </p> <a href="https://publications.waset.org/abstracts/12841/the-rupture-of-tendon-achilles-during-the-recreative-and-sports-activities" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/12841.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">247</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2841</span> Soft Robotic Exoskeletal Glove with Single Motor-Driven Tendon-Based Differential Drive</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Naveed%20Akhter">M. Naveed Akhter</a>, <a href="https://publications.waset.org/abstracts/search?q=Jawad%20Aslam"> Jawad Aslam</a>, <a href="https://publications.waset.org/abstracts/search?q=Omer%20Gillani"> Omer Gillani</a> </p> <p class="card-text"><strong>Abstract:</strong></p> To aid and rehabilitate increasing number of patients suffering from spinal cord injury (SCI) and stroke, a lightweight, wearable, and 3D printable exoskeletal glove has been developed. Unlike previously developed metal or fabric-based exoskeletons, this research presents the development of soft exoskeletal glove made of thermoplastic polyurethane (TPU). The drive mechanism consists of a single motor-driven antagonistic tendon to perform extension or flexion of middle and index finger. The tendon-based differential drive has been incorporated to allow for grasping of irregularly shaped objects. The design features easy 3D-printability with TPU without a need for supports. The overall weight of the glove and the actuation unit is approximately 500g. Performance of the glove was tested on a custom test-bench with integrated load cells, and the grip strength was tested to be around 30N per finger while grasping objects of irregular shape. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=3D%20printable" title="3D printable">3D printable</a>, <a href="https://publications.waset.org/abstracts/search?q=differential%20drive" title=" differential drive"> differential drive</a>, <a href="https://publications.waset.org/abstracts/search?q=exoskeletal%20glove" title=" exoskeletal glove"> exoskeletal glove</a>, <a href="https://publications.waset.org/abstracts/search?q=rehabilitation" title=" rehabilitation"> rehabilitation</a>, <a href="https://publications.waset.org/abstracts/search?q=single%20motor%20driven" title=" single motor driven"> single motor driven</a> </p> <a href="https://publications.waset.org/abstracts/111299/soft-robotic-exoskeletal-glove-with-single-motor-driven-tendon-based-differential-drive" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/111299.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">143</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2840</span> Treatment of Full-Thickness Rotator Cuff Tendon Tear Using Umbilical Cord Blood-Derived Mesenchymal Stem Cells and Polydeoxyribonucleotides in a Rabbit Model</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sang%20Chul%20Lee">Sang Chul Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Gi-Young%20Park"> Gi-Young Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Dong%20Rak%20Kwon"> Dong Rak Kwon</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Objective: The aim of this study was to investigate regenerative effects of ultrasound (US)-guided injection with human umbilical cord blood-derived mesenchymal stem cells (UCB-MSCs) and/or polydeoxyribonucleotide (PDRN) injection in a chronic traumatic full-thickness rotator cuff tendon tear (FTRCTT) in a rabbit model. Material and Methods: Rabbits (n = 32) were allocated into 4 groups. After a 5-mm sized FTRCTT just proximal to the insertion site on the subscapularis tendon was created by excision, the wound was immediately covered by silicone tube to prevent natural healing. After 6 weeks, 4 injections (0.2 mL normal saline, G1; 0.2 mL PDRN, G2; 0.2 mL UCB-MSCs, G3; and 0.2 mL UCB-MSCs with 0.2ml PDRN, G4) were injected into FTRCTT under US guidance. We evaluated gross morphologic changes on all rabbits after sacrifice. Masson’s trichrome, anti-type 1 collagen antibody, bromodeoxyuridine, proliferating cell nuclear antigen, vascular endothelial growth factor and platelet endothelial cell adhesion molecule stain were performed to evaluate histological changes. Motion analysis was also performed. Results: The gross morphologic mean tendon tear size in G3 and 4 was significantly smaller than that of G1 and 2 (p < .05). However, there were no significant differences in tendon tear size between G3 and 4. In G4, newly regenerated collagen type 1 fibers, proliferating cells activity, angiogenesis, walking distance, fast walking time, and mean walking speed were greater than in the other three groups on histological examination and motion analysis. Conclusion: Co-injection of UCB-MSCs and PDRN was more effective than UCB-MSCs injection alone in histological and motion analysis in a rabbit model of chronic traumatic FTRCTT. However, there was no significant difference in gross morphologic change of tendon tear between UCB-MSCs with/without PDRN injection. The results of this study regarding the combination of UCB-MSCs and PDRN are worth additional investigations. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=mesenchymal%20stem%20cell" title="mesenchymal stem cell">mesenchymal stem cell</a>, <a href="https://publications.waset.org/abstracts/search?q=umbilical%20cord" title=" umbilical cord"> umbilical cord</a>, <a href="https://publications.waset.org/abstracts/search?q=polydeoxyribonucleotides" title=" polydeoxyribonucleotides"> polydeoxyribonucleotides</a>, <a href="https://publications.waset.org/abstracts/search?q=shoulder" title=" shoulder"> shoulder</a>, <a href="https://publications.waset.org/abstracts/search?q=rotator%20cuff" title=" rotator cuff"> rotator cuff</a>, <a href="https://publications.waset.org/abstracts/search?q=ultrasonography" title=" ultrasonography"> ultrasonography</a>, <a href="https://publications.waset.org/abstracts/search?q=injections" title=" injections"> injections</a> </p> <a href="https://publications.waset.org/abstracts/88770/treatment-of-full-thickness-rotator-cuff-tendon-tear-using-umbilical-cord-blood-derived-mesenchymal-stem-cells-and-polydeoxyribonucleotides-in-a-rabbit-model" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/88770.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">185</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2839</span> Mini-Open Repair Using Ring Forceps Show Similar Results to Repair Using Achillon Device in Acute Achilles Tendon Rupture</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Chul%20Hyun%20Park">Chul Hyun Park</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background:Repair using the Achillon deviceis a representative mini-open repair technique;however, the limitations of this technique includethe need for special instruments and decreasedrepair strength.A modifiedmini-open repair using ring forcepsmight overcome these limitations. Purpose:This study was performed to compare the Achillon device with ring forceps in mini-open repairsof acute Achilles tendon rupture. Study Design:This was a retrospective cohort study, and the level of evidence was3. Methods:Fifty patients (41 men and 9 women), withacute Achilles tendon rupture on one foot, were consecutively treated using mini-open repair techniques. The first 20 patients were treated using the Achillon device (Achillon group) and the subsequent 30 patients were treated using a ring forceps (Forcep group). Clinical, functional, and isokinetic results,and postoperative complications were compared between the two groups at the last follow-up. Clinical evaluations wereperformed using the American Orthopedic Foot and Ankle Society (AOFAS) score, Achilles tendon Total Rupture Score (ATRS), length of incision, and operation time. Functional evaluationsincludedactive range of motion (ROM) of the ankle joint, maximum calf circumference (MCC), hopping test, and single limb heel-rise (SLHR) test. Isokinetic evaluations were performed using the isokinetic test for ankle plantar flexion. Results:The AOFAS score (p=0.669), ATRS (p=0.753), and length of incision (p=0.305) were not significantly different between the groups. Operative times in the Achillon group were significantly shorter than that in the Forcep group (p<0.001).The maximum height of SLHR (p=0.023) and number of SLHRs (p=0.045) in the Forcep group were significantly greater than that in the Achillon group. No significant differences in the mean peak torques for plantar flexion at angular speeds of 30°/s (p=0.219) and 120°/s (p=0.656) were detected between the groups. There was no significant difference in the occurrence of postoperative complications between the groups (p=0.093). Conclusion:The ring forceps technique is comparable with the Achillon technique with respect to clinical, functional, and isokinetic results and the postoperative complications. Given that no special instrument is required, the ring forceps technique could be a better option for acute Achilles tendon rupture repair. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=achilles%20tendon" title="achilles tendon">achilles tendon</a>, <a href="https://publications.waset.org/abstracts/search?q=acute%20rupture" title=" acute rupture"> acute rupture</a>, <a href="https://publications.waset.org/abstracts/search?q=repair" title=" repair"> repair</a>, <a href="https://publications.waset.org/abstracts/search?q=mini-open" title=" mini-open"> mini-open</a> </p> <a href="https://publications.waset.org/abstracts/158646/mini-open-repair-using-ring-forceps-show-similar-results-to-repair-using-achillon-device-in-acute-achilles-tendon-rupture" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/158646.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">81</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2838</span> Determination of Johnson-Cook Material and Failure Model Constants for High Tensile Strength Tendon Steel in Post-Tensioned Concrete Members</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=I.%20Gkolfinopoulos">I. Gkolfinopoulos</a>, <a href="https://publications.waset.org/abstracts/search?q=N.%20Chijiwa"> N. Chijiwa</a> </p> <p class="card-text"><strong>Abstract:</strong></p> To evaluate the remaining capacity in concrete tensioned members, it is important to accurately estimate damage in precast concrete tendons. In this research Johnson-Cook model and damage parameters of high-strength steel material were calculated by static and dynamic uniaxial tensile tests. Replication of experimental results was achieved through finite element analysis for both single 8-noded three-dimensional element as well as the full-scale dob-bone shaped model and relevant model parameters are proposed. Finally, simulation results in terms of strain and deformation were verified using digital image correlation analysis. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=DIC%20analysis" title="DIC analysis">DIC analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=Johnson-Cook" title=" Johnson-Cook"> Johnson-Cook</a>, <a href="https://publications.waset.org/abstracts/search?q=quasi-static" title=" quasi-static"> quasi-static</a>, <a href="https://publications.waset.org/abstracts/search?q=dynamic" title=" dynamic"> dynamic</a>, <a href="https://publications.waset.org/abstracts/search?q=rupture" title=" rupture"> rupture</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a> </p> <a href="https://publications.waset.org/abstracts/152866/determination-of-johnson-cook-material-and-failure-model-constants-for-high-tensile-strength-tendon-steel-in-post-tensioned-concrete-members" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/152866.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">147</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2837</span> Determination of Activation Energy for Thermal Decomposition of Selected Soft Tissues Components</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Ekiert">M. Ekiert</a>, <a href="https://publications.waset.org/abstracts/search?q=T.%20Uhl"> T. Uhl</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Mlyniec"> A. Mlyniec</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Tendons are the biological soft tissue structures composed of collagen, proteoglycan, glycoproteins, water and cells of extracellular matrix (ECM). Tendons, which primary function is to transfer force generated by the muscles to the bones causing joints movement, are exposed to many micro and macro damages. In fact, tendons and ligaments trauma are one of the most numerous injuries of human musculoskeletal system, causing for many people (particularly for athletes and physically active people), recurring disorders, chronic pain or even inability of movement. The number of tendons reconstruction and transplantation procedures is increasing every year. Therefore, studies on soft tissues storage conditions (influencing i.e. tissue aging) seem to be an extremely important issue. In this study, an atomic-scale investigation on the kinetics of decomposition of two selected tendon components – collagen type I (which forms a 60-85% of a tendon dry mass) and elastin protein (which combine with ECM creates elastic fibers of connective tissues) is presented. A molecular model of collagen and elastin was developed based on crystal structure of triple-helical collagen-like 1QSU peptide and P15502 human elastin protein, respectively. Each model employed 4 linear strands collagen/elastin strands per unit cell, distributed in 2x2 matrix arrangement, placed in simulation box filled with water molecules. A decomposition phenomena was simulated with molecular dynamics (MD) method using ReaxFF force field and periodic boundary conditions. A set of NVT-MD runs was performed for 1000K temperature range in order to obtained temperature-depended rate of production of decomposition by-products. Based on calculated reaction rates activation energies and pre-exponential factors, required to formulate Arrhenius equations describing kinetics of decomposition of tested soft tissue components, were calculated. Moreover, by adjusting a model developed for collagen, system scalability and correct implementation of the periodic boundary conditions were evaluated. An obtained results provide a deeper insight into decomposition of selected tendon components. A developed methodology may also be easily transferred to other connective tissue elements and therefore might be used for further studies on soft tissues aging. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=decomposition" title="decomposition">decomposition</a>, <a href="https://publications.waset.org/abstracts/search?q=molecular%20dynamics" title=" molecular dynamics"> molecular dynamics</a>, <a href="https://publications.waset.org/abstracts/search?q=soft%20tissue" title=" soft tissue"> soft tissue</a>, <a href="https://publications.waset.org/abstracts/search?q=tendons" title=" tendons"> tendons</a> </p> <a href="https://publications.waset.org/abstracts/70222/determination-of-activation-energy-for-thermal-decomposition-of-selected-soft-tissues-components" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/70222.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">210</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2836</span> Partial Knowledge Transfer Between the Source Problem and the Target Problem in Genetic Algorithms</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Terence%20Soule">Terence Soule</a>, <a href="https://publications.waset.org/abstracts/search?q=Tami%20Al%20Ghamdi"> Tami Al Ghamdi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> To study how the partial knowledge transfer may affect the Genetic Algorithm (GA) performance, we model the Transfer Learning (TL) process using GA as the model solver. The objective of the TL is to transfer the knowledge from one problem to another related problem. This process imitates how humans think in their daily life. In this paper, we proposed to study a case where the knowledge transferred from the S problem has less information than what the T problem needs. We sampled the transferred population using different strategies of TL. The results showed transfer part of the knowledge is helpful and speeds the GA process of finding a solution to the problem. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=transfer%20learning" title="transfer learning">transfer learning</a>, <a href="https://publications.waset.org/abstracts/search?q=partial%20transfer" title=" partial transfer"> partial transfer</a>, <a href="https://publications.waset.org/abstracts/search?q=evolutionary%20computation" title=" evolutionary computation"> evolutionary computation</a>, <a href="https://publications.waset.org/abstracts/search?q=genetic%20algorithm" title=" genetic algorithm"> genetic algorithm</a> </p> <a href="https://publications.waset.org/abstracts/147924/partial-knowledge-transfer-between-the-source-problem-and-the-target-problem-in-genetic-algorithms" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/147924.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">132</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2835</span> A Constitutive Model of Ligaments and Tendons Accounting for Fiber-Matrix Interaction</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ratchada%20Sopakayang">Ratchada Sopakayang</a>, <a href="https://publications.waset.org/abstracts/search?q=Gerhard%20A.%20Holzapfel"> Gerhard A. Holzapfel</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this study, a new constitutive model is developed to describe the hyperelastic behavior of collagenous tissues with a parallel arrangement of collagen fibers such as ligaments and tendons. The model is formulated using a continuum approach incorporating the structural changes of the main tissue components: collagen fibers, proteoglycan-rich matrix and fiber-matrix interaction. The mechanical contribution of the interaction between the fibers and the matrix is simply expressed by a coupling term. The structural change of the collagen fibers is incorporated in the constitutive model to describe the activation of the fibers under tissue straining. Finally, the constitutive model can easily describe the stress-stretch nonlinearity which occurs when a ligament/tendon is axially stretched. This study shows that the interaction between the fibers and the matrix contributes to the mechanical tissue response. Therefore, the model may lead to a better understanding of the physiological mechanisms of ligaments and tendons under axial loading. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=constitutive%20model" title="constitutive model">constitutive model</a>, <a href="https://publications.waset.org/abstracts/search?q=fiber-matrix" title=" fiber-matrix"> fiber-matrix</a>, <a href="https://publications.waset.org/abstracts/search?q=hyperelasticity" title=" hyperelasticity"> hyperelasticity</a>, <a href="https://publications.waset.org/abstracts/search?q=interaction" title=" interaction"> interaction</a>, <a href="https://publications.waset.org/abstracts/search?q=ligament" title=" ligament"> ligament</a>, <a href="https://publications.waset.org/abstracts/search?q=tendon" title=" tendon"> tendon</a> </p> <a href="https://publications.waset.org/abstracts/67881/a-constitutive-model-of-ligaments-and-tendons-accounting-for-fiber-matrix-interaction" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/67881.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">299</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2834</span> University-Industry Technology Transfer and Technology Transfer Offices in Emerging Economies</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jos%C3%A9%20Carlos%20Rodr%C3%ADguez">José Carlos Rodríguez</a>, <a href="https://publications.waset.org/abstracts/search?q=Mario%20G%C3%B3mez"> Mario Gómez</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The aim of this paper is to get insight on the nature of university-industry technology transfer (UITT) and technology transfer offices (TTOs) activity at universities in the case of emerging economies. In relation to the process of transferring knowledge/technology in the case of emerging economies, knowledge/technology transfer in these economies are more reactive than in developed economies due to differences in maturity of technologies. It is assumed in this paper that knowledge/technology transfer is a complex phenomenon, and thus the paper contributes to get insight on the nature of UITT and TTOs creation in the case of emerging economies by using a system dynamics model of knowledge/technology transfer in these countries. The paper recognizes the differences between industrialized countries and emerging economies on these phenomena. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=university-industry%20technology%20transfer" title="university-industry technology transfer">university-industry technology transfer</a>, <a href="https://publications.waset.org/abstracts/search?q=technology%20transfer%20offices" title=" technology transfer offices"> technology transfer offices</a>, <a href="https://publications.waset.org/abstracts/search?q=technology%20transfer%20models" title=" technology transfer models"> technology transfer models</a>, <a href="https://publications.waset.org/abstracts/search?q=emerging%20economies" title=" emerging economies"> emerging economies</a> </p> <a href="https://publications.waset.org/abstracts/88464/university-industry-technology-transfer-and-technology-transfer-offices-in-emerging-economies" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/88464.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">250</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2833</span> A Computational Framework for Load Mediated Patellar Ligaments Damage at the Tropocollagen Level</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Fadi%20Al%20Khatib">Fadi Al Khatib</a>, <a href="https://publications.waset.org/abstracts/search?q=Raouf%20Mbarki"> Raouf Mbarki</a>, <a href="https://publications.waset.org/abstracts/search?q=Malek%20Adouni"> Malek Adouni</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In various sport and recreational activities, the patellofemoral joint undergoes large forces and moments while accommodating the significant knee joint movement. In doing so, this joint is commonly the source of anterior knee pain related to instability in normal patellar tracking and excessive pressure syndrome. One well-observed explanation of the instability of the normal patellar tracking is the patellofemoral ligaments and patellar tendon damage. Improved knowledge of the damage mechanism mediating ligaments and tendon injuries can be a great help not only in rehabilitation and prevention procedures but also in the design of better reconstruction systems in the management of knee joint disorders. This damage mechanism, specifically due to excessive mechanical loading, has been linked to the micro level of the fibred structure precisely to the tropocollagen molecules and their connection density. We argue defining a clear frame starting from the bottom (micro level) to up (macro level) in the hierarchies of the soft tissue may elucidate the essential underpinning on the state of the ligaments damage. To do so, in this study a multiscale fibril reinforced hyper elastoplastic Finite Element model that accounts for the synergy between molecular and continuum syntheses was developed to determine the short-term stresses/strains patellofemoral ligaments and tendon response. The plasticity of the proposed model is associated only with the uniaxial deformation of the collagen fibril. The yield strength of the fibril is a function of the cross-link density between tropocollagen molecules, defined here by a density function. This function obtained through a Coarse-graining procedure linking nanoscale collagen features and the tissue level materials properties using molecular dynamics simulations. The hierarchies of the soft tissues were implemented using the rule of mixtures. Thereafter, the model was calibrated using a statistical calibration procedure. The model then implemented into a real structure of patellofemoral ligaments and patellar tendon (OpenKnee) and simulated under realistic loading conditions. With the calibrated material parameters the calculated axial stress lies well with the experimental measurement with a coefficient of determination (R2) equal to 0.91 and 0.92 for the patellofemoral ligaments and the patellar tendon respectively. The ‘best’ prediction of the yielding strength and strain as compared with the reported experimental data yielded when the cross-link density between the tropocollagen molecule of the fibril equal to 5.5 ± 0.5 (patellofemoral ligaments) and 12 (patellar tendon). Damage initiation of the patellofemoral ligaments was located at the femoral insertions while the damage of the patellar tendon happened in the middle of the structure. These predicted finding showed a meaningful correlation between the cross-link density of the tropocollagen molecules and the stiffness of the connective tissues of the extensor mechanism. Also, damage initiation and propagation were documented with this model, which were in satisfactory agreement with earlier observation. To the best of our knowledge, this is the first attempt to model ligaments from the bottom up, predicted depending to the tropocollagen cross-link density. This approach appears more meaningful towards a realistic simulation of a damaging process or repair attempt compared with certain published studies. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=tropocollagen" title="tropocollagen">tropocollagen</a>, <a href="https://publications.waset.org/abstracts/search?q=multiscale%20model" title=" multiscale model"> multiscale model</a>, <a href="https://publications.waset.org/abstracts/search?q=fibrils" title=" fibrils"> fibrils</a>, <a href="https://publications.waset.org/abstracts/search?q=knee%20ligaments" title=" knee ligaments"> knee ligaments</a> </p> <a href="https://publications.waset.org/abstracts/98917/a-computational-framework-for-load-mediated-patellar-ligaments-damage-at-the-tropocollagen-level" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/98917.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">128</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2832</span> Quick off the Mark with Achilles Tendon Rupture</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Emily%20Moore">Emily Moore</a>, <a href="https://publications.waset.org/abstracts/search?q=Andrew%20Gaukroger"> Andrew Gaukroger</a>, <a href="https://publications.waset.org/abstracts/search?q=Matthew%20Solan"> Matthew Solan</a>, <a href="https://publications.waset.org/abstracts/search?q=Lucy%20Bailey"> Lucy Bailey</a>, <a href="https://publications.waset.org/abstracts/search?q=Alexandra%20Boxall"> Alexandra Boxall</a>, <a href="https://publications.waset.org/abstracts/search?q=Andrew%20Carne"> Andrew Carne</a>, <a href="https://publications.waset.org/abstracts/search?q=Chintu%20Gadamsetty"> Chintu Gadamsetty</a>, <a href="https://publications.waset.org/abstracts/search?q=Charlotte%20Morley"> Charlotte Morley</a>, <a href="https://publications.waset.org/abstracts/search?q=Katy%20Western"> Katy Western</a>, <a href="https://publications.waset.org/abstracts/search?q=Iwona%20Kolodziejczyk"> Iwona Kolodziejczyk</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: Rupture of the Achilles tendon is common and has a long recovery period. Most cases are managed non-operatively. Foot and Ankle Surgeons advise an ultrasound scan to check the gap between the torn ends. A large gap (with the ankle in equinus) is a relative indication for surgery. The definitive decision regarding surgical versus non-operative management can only be made once an ultrasound scan is undertaken and the patient is subsequently reviewed by a Foot and Ankle surgeon. To get to this point, the patient journey involves several hospital departments. In nearby trusts, patients reattend for a scan and go to the plaster room both before and after the ultrasound for removal and re-application of the cast. At a third visit to the hospital, the surgeon and patient discuss options for definitive treatment. It may take 2-3 weeks from the initial Emergency Department visit before the final treatment decision is made. This “wasted time” is ultimately added to the recovery period for the patient. In this hospital, Achilles rupture patients are seen in a weekly multidisciplinary OneStop Heel Pain clinic. This pathway was already efficient but subject to occasional frustrating delays if a key staff member was absent. A new pathway was introduced with the goal to reduce delays to a definitive treatment plan. Method: A retrospective series of Achilles tendon ruptures managed according to the 2019 protocol was identified. Time taken from the Emergency Department to have both an ultrasound scan and specialist Foot and Ankle surgical review were calculated. 30 consecutive patients were treated with our new pathway and prospectively followed. The time taken for a scan and for specialist review were compared to the 30 consecutive cases from the 2019 (pre-COVID) cohort. The new pathway includes 1. A new contoured splint applied to the front of the injured limb held with a bandage. This can be removed and replaced (unlike a plaster cast) in the ultrasound department, removing the need for plaster room visits. 2. Urgent triage to a Foot and Ankle specialist. 3. Ultrasound scan for assessment of rupture gap and deep vein thrombosis check. 4. Early decision regarding surgery. Transfer to weight bearing in a prosthetic boot in equinuswithout waiting for the once-a-week clinic. 5. Extended oral VTE prophylaxis. Results: The time taken for a patient to have both an ultrasound scan and specialist review fell > 50%. All patients in the new pathway reached a definitive treatment decision within one week. There were no significant differences in patient demographics or rates of surgical vs non-operative treatment. The mean time from Emergency Department visit to specialist review and ultrasound scan fell from 8.7 days (old protocol) to 2.9 days (new pathway). The maximum time for this fell from 23 days (old protocol) to 6 days (new pathway). Conclusion: Teamwork and innovation have improved the experience for patients with an Achilles tendon rupture. The new pathway brings many advantages - reduced time in the Emergency Department, fewer hospital visits, less time using crutches and reduced overall recovery time. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=orthopaedics" title="orthopaedics">orthopaedics</a>, <a href="https://publications.waset.org/abstracts/search?q=achilles%20rupture" title=" achilles rupture"> achilles rupture</a>, <a href="https://publications.waset.org/abstracts/search?q=ultrasound" title=" ultrasound"> ultrasound</a>, <a href="https://publications.waset.org/abstracts/search?q=innovation" title=" innovation"> innovation</a> </p> <a href="https://publications.waset.org/abstracts/157093/quick-off-the-mark-with-achilles-tendon-rupture" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/157093.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">123</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2831</span> Jet Impingement Heat Transfer on a Rib-Roughened Flat Plate</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=A.%20H.%20Alenezi">A. H. Alenezi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Cooling by impingement jet is known to have a significant high local and average heat transfer coefficient which make it widely used in industrial cooling systems. The heat transfer characteristics of an impinging jet on rib-roughened flat plate has been investigated numerically. This paper was set out to investigate the effect of rib height on the heat transfer rate. Since the flow needs to have enough spacing after passing the rib to allow reattachment especially for high Reynolds numbers, this study focuses on finding the optimum rib height which would be the best to maximize the heat transfer rate downstream the plate. This investigation employs a round nozzle with hydraulic diameter (Dh) of 13.5 mm, Jet-to-target distance of (H/D) of 4, rib location=1.5D and and finally jet angels of 45˚ and 90˚ under the influence of Re =10,000. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=jet%20impingement" title="jet impingement">jet impingement</a>, <a href="https://publications.waset.org/abstracts/search?q=CFD" title=" CFD"> CFD</a>, <a href="https://publications.waset.org/abstracts/search?q=turbulence%20model" title=" turbulence model"> turbulence model</a>, <a href="https://publications.waset.org/abstracts/search?q=heat%20transfer" title=" heat transfer"> heat transfer</a> </p> <a href="https://publications.waset.org/abstracts/57530/jet-impingement-heat-transfer-on-a-rib-roughened-flat-plate" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/57530.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">351</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2830</span> A Multiple Freezing/Thawing Cycles Influence Internal Structure and Mechanical Properties of Achilles Tendon </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Martyna%20Ekiert">Martyna Ekiert</a>, <a href="https://publications.waset.org/abstracts/search?q=Natalia%20Grzechnik"> Natalia Grzechnik</a>, <a href="https://publications.waset.org/abstracts/search?q=Joanna%20Karbowniczek"> Joanna Karbowniczek</a>, <a href="https://publications.waset.org/abstracts/search?q=Urszula%20Stachewicz"> Urszula Stachewicz</a>, <a href="https://publications.waset.org/abstracts/search?q=Andrzej%20Mlyniec"> Andrzej Mlyniec</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Tendon grafting is a common procedure performed to treat tendon rupture. Before the surgical procedure, tissues intended for grafts (i.e., Achilles tendon) are stored in ultra-low temperatures for a long time and also may be subjected to unfavorable conditions, such as repetitive freezing (F) and thawing (T). Such storage protocols may highly influence the graft mechanical properties, decrease its functionality and thus increase the risk of complications during the transplant procedure. The literature reports on the influence of multiple F/T cycles on internal structure and mechanical properties of tendons stay inconclusive, confirming and denying the negative influence of multiple F/T at the same time. An inconsistent research methodology and lack of clear limit of F/T cycles, which disqualifies tissue for surgical graft purposes, encouraged us to investigate the issue of multiple F/T cycles by the mean of biomechanical tensile tests supported with Scanning Electron Microscope (SEM) imaging. The study was conducted on male bovine Achilles tendon-derived from the local abattoir. Fresh tendons were cleaned of excessive membranes and then sectioned to obtained fascicle bundles. Collected samples were randomly assigned to 6 groups subjected to 1, 2, 4, 6, 8 and 12 cycles of freezing-thawing (F/T), respectively. Each F/T cycle included deep freezing at -80°C temperature, followed by thawing at room temperature. After final thawing, thin slices of the side part of samples subjected to 1, 4, 8 and 12 F/T cycles were collected for SEM imaging. Then, the width and thickness of all samples were measured to calculate the cross-sectional area. Biomechanical tests were performed using the universal testing machine (model Instron 8872, INSTRON®, Norwood, Massachusetts, USA) using a load cell with a maximum capacity of 250 kN and standard atmospheric conditions. Both ends of each fascicle bundle were manually clamped in grasping clamps using abrasive paper and wet cellulose wadding swabs to prevent tissue slipping while clamping and testing. Samples were subjected to the testing procedure including pre-loading, pre-cycling, loading, holding and unloading steps to obtain stress-strain curves for representing tendon stretching and relaxation. The stiffness of AT fascicles bundle samples was evaluated in terms of modulus of elasticity (Young’s modulus), calculated from the slope of the linear region of stress-strain curves. SEM imaging was preceded by chemical sample preparation including 24hr fixation in 3% glutaraldehyde buffered with 0.1 M phosphate buffer, washing with 0.1 M phosphate buffer solution and dehydration in a graded ethanol solution. SEM images (Merlin Gemini II microscope, ZEISS®) were taken using 30 000x mag, which allowed measuring a diameter of collagen fibrils. The results confirm a decrease in fascicle bundles Young’s modulus as well as a decrease in the diameter of collagen fibrils. These results confirm the negative influence of multiple F/T cycles on the mechanical properties of tendon tissue. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=biomechanics" title="biomechanics">biomechanics</a>, <a href="https://publications.waset.org/abstracts/search?q=collagen" title=" collagen"> collagen</a>, <a href="https://publications.waset.org/abstracts/search?q=fascicle%20bundles" title=" fascicle bundles"> fascicle bundles</a>, <a href="https://publications.waset.org/abstracts/search?q=soft%20tissue" title=" soft tissue"> soft tissue</a> </p> <a href="https://publications.waset.org/abstracts/107911/a-multiple-freezingthawing-cycles-influence-internal-structure-and-mechanical-properties-of-achilles-tendon" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/107911.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">125</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">2829</span> Experimental Study of Heat Transfer Enhancement Using Protruded Rectangular Fin</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Tarique%20Jamil%20Khan">Tarique Jamil Khan</a>, <a href="https://publications.waset.org/abstracts/search?q=Swapnil%20Pande"> Swapnil Pande</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The investigation deals with the study of heat transfer enhancement using protruded square fin. This study is enough to determine whether protrusion in forced convection is enough to enhance the rate of heat transfer. It includes the results after performing experiments by using a plane rectangular fin of aluminum material and the same dimension rectangular fin of the same material but having protruded circular shape extended normally. The fins made by a sand casting method. The results clearly mentioned that the protruded surface is effective enough to enhance the rate of heat transfer. This research investigates a modern fin topologies heat transfer characteristics that will clearly outdated the conventional fin to increase the rate of heat transfer. Protruded fins improve the rate of heat transfer compared to solid fin by varying shape of the protrusion in diameter and height. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=heat%20transfer%20enhancement" title="heat transfer enhancement">heat transfer enhancement</a>, <a href="https://publications.waset.org/abstracts/search?q=forced%20convection" title=" forced convection"> forced convection</a>, <a href="https://publications.waset.org/abstracts/search?q=protruted%20fin" title=" protruted fin"> protruted fin</a>, <a href="https://publications.waset.org/abstracts/search?q=rectangular%20fin" title=" rectangular fin"> rectangular fin</a> </p> <a href="https://publications.waset.org/abstracts/56370/experimental-study-of-heat-transfer-enhancement-using-protruded-rectangular-fin" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/56370.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">362</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">&lsaquo;</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=95">95</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=96">96</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=tendon%20transfer&amp;page=2" rel="next">&rsaquo;</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">&copy; 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">&times;</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>

Pages: 1 2 3 4 5 6 7 8 9 10