CINXE.COM
Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays | Research Square
<!DOCTYPE html><html lang="en"><head><meta charSet="utf-8"/><meta name="twitter:card" content="summary"/><meta name="twitter:site" content="@researchsquare"/><meta name="twitter:creator" content="@researchsquare"/><meta property="og:url" content="https://www.researchsquare.com"/><meta property="og:type" content="website"/><meta property="og:image:alt" content="Research Square"/><meta property="og:image:width" content="1280"/><meta property="og:image:height" content="720"/><meta property="og:locale" content="en_US"/><title>Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays | Research Square</title><meta name="robots" content="index,follow"/><meta property="og:title" content="Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays"/><meta property="og:description" content="Owing to their ability to reliably detect even very rare antigen-specific B cells in cellular isolates such as peripheral blood mononuclear cells (PBMC), and doing so robustly in a high throughput-compatible manner, B cell ELISPOT/FluoroSpot (collectively &ldquo;B cell ImmunoSpot&rdquo;) tests..."/><meta property="og:image" content=""/><meta name="viewport" content="width=device-width, initial-scale=1"/><meta name="apple-mobile-web-app-title" content="Research Square"/><meta name="application-name" content="Research Square"/><link rel="shortcut icon" type="image/x-icon" href="/static/favicons/favicon.ico"/><link rel="apple-touch-icon" sizes="180x180" href="/static/favicons/apple-touch-icon.png"/><link rel="icon" type="image/png" sizes="32x32" href="/static/favicons/favicon-32x32.png"/><link rel="icon" type="image/png" sizes="16x16" href="/static/favicons/favicon-16x16.png"/><link rel="manifest" href="/static/favicons/site.webmanifest"/><link rel="mask-icon" href="/static/favicons/safari-pinned-tab.svg" color="#244261"/><meta name="msapplication-config" content="/static/favicons/browserconfig.xml"/><meta name="msapplication-TileColor" content="#ffffff"/><meta name="theme-color" content="#ffffff"/><link rel="preconnect" href="https://fonts.gstatic.com/" crossorigin="anonymous"/><link rel="preconnect" href="https://www.googletagmanager.com" crossorigin="anonymous"/><link rel="preconnect" href="https://www.google-analytics.com" crossorigin="anonymous"/><link rel="preconnect" href="https://app.snipcart.com"/><link rel="preconnect" href="https://cdn.snipcart.com"/><link rel="canonical" href="https://www.researchsquare.com/article/rs-3994852/v1"/><meta name="description" content="Owing to their ability to reliably detect even very rare antigen-specific B cells in cellular isolates such as peripheral blood mononuclear cells (PBMC), and doing so robustly in a high throughput-compatible manner, B cell ELISPOT/FluoroSpot (collectively &ldquo;B cell ImmunoSpot&rdquo;) tests..."/><meta property="og:title" content="Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays"/><meta property="og:description" content="Owing to their ability to reliably detect even very rare antigen-specific B cells in cellular isolates such as peripheral blood mononuclear cells (PBMC), and doing so robustly in a high throughput-compatible manner, B cell ELISPOT/FluoroSpot (collectively &ldquo;B cell ImmunoSpot&rdquo;) tests..."/><meta property="og:url" content="https://www.researchsquare.com/article/rs-3994852/v1"/><meta property="og:type" content="article"/><meta name="twitter:title" content="Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays"/><meta name="twitter:description" content="Owing to their ability to reliably detect even very rare antigen-specific B cells in cellular isolates such as peripheral blood mononuclear cells (PBMC), and doing so robustly in a high throughput-compatible manner, B cell ELISPOT/FluoroSpot (collectively &ldquo;B cell ImmunoSpot&rdquo;) tests..."/><meta name="citation_publication_date" content="2024-02-29"/><meta property="citation_author" content="Paul V. Lehmann"/><meta property="citation_author" content="Alexey Y. Karulin"/><meta property="citation_author" content="Noémi Becza"/><meta property="citation_author" content="Lingling Yao"/><meta property="citation_author" content="Zhigang Liu"/><meta property="citation_author" content="Jack Chepke"/><meta property="citation_author" content="Andrea Maul-Pavicic"/><meta property="citation_author" content="Carla Wolf"/><meta property="citation_author" content="Sebastian Köppert"/><meta property="citation_author" content="Alexis V. Valente"/><meta property="citation_author" content="Anton V. Gorbachev"/><meta property="citation_author" content="Magdalena Tary-Lehmann"/><meta property="citation_author" content="Greg A. Kirchenbaum"/><meta name="citation_title" content="Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays"/><meta name="citation_doi" content="10.21203/rs.3.rs-3994852/v1"/><meta name="citation_pdf_url" content="https://www.researchsquare.com/article/rs-3994852/latest.pdf"/><script async="">(function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src='https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);})(window,document,'script','dataLayer','GTM-K279D39R');</script><meta name="next-head-count" content="58"/><script async="" src="https://polyfill-fastly.io/v3/polyfill.min.js?flags=gated&features=String.prototype.startsWith%2CString.prototype.endsWith%2CArray.prototype.forEach%2CSet%2CArray.prototype.includes%2CString.prototype.includes%2CArray.prototype.find%2CMap%2CObject.values"></script><link rel="prefetch stylesheet" href="https://cdnjs.cloudflare.com/ajax/libs/font-awesome/5.11.2/css/all.min.css" integrity="sha256-+N4/V/SbAFiW1MPBCXnfnP9QSN3+Keu+NlB+0ev/YKQ=" crossorigin="anonymous"/><link rel="preconnect" href="https://app.snipcart.com"/><link rel="preconnect" href="https://cdn.snipcart.com"/><link rel="prefetch stylesheet" href="https://cdn.snipcart.com/themes/v3.3.0/default/snipcart.css"/><script async="" src="https://cdn.snipcart.com/themes/v3.3.0/default/snipcart.js"></script><link data-next-font="" rel="preconnect" href="/" crossorigin="anonymous"/><link rel="preload" href="/_next/static/css/feb0ee85c456a5c1.css" as="style"/><link rel="stylesheet" href="/_next/static/css/feb0ee85c456a5c1.css" data-n-g=""/><link rel="preload" href="/_next/static/css/56ce4858aa7b85f8.css" as="style"/><link rel="stylesheet" href="/_next/static/css/56ce4858aa7b85f8.css"/><noscript data-n-css=""></noscript><script defer="" nomodule="" src="/_next/static/chunks/polyfills-c67a75d1b6f99dc8.js"></script><script defer="" src="/_next/static/chunks/2b7b2d2a-6e50b533a3c532c7.js"></script><script defer="" src="/_next/static/chunks/4454-a821deae589edb63.js"></script><script defer="" src="/_next/static/chunks/6436.d14751611bf763e5.js"></script><script src="/_next/static/chunks/webpack-1e3962e672b4914d.js" defer=""></script><script src="/_next/static/chunks/framework-918963c1d31953b8.js" defer=""></script><script src="/_next/static/chunks/main-67d640b647b43c0d.js" defer=""></script><script src="/_next/static/chunks/pages/_app-d0d21e458e192a22.js" defer=""></script><script src="/_next/static/chunks/75fc9c18-02b28d24f737c2ca.js" defer=""></script><script src="/_next/static/chunks/d6e1aeb5-b9df3beef41be048.js" defer=""></script><script src="/_next/static/chunks/4265-d3a87a268de73026.js" defer=""></script><script src="/_next/static/chunks/724-c9bf7ca8e2d58080.js" defer=""></script><script src="/_next/static/chunks/7206-fe2705e68e48482b.js" defer=""></script><script src="/_next/static/chunks/4197-b29b86f3dbefb262.js" defer=""></script><script src="/_next/static/chunks/9679-2f75d2099ae6893d.js" defer=""></script><script src="/_next/static/chunks/4522-4b049b185fffc8ef.js" defer=""></script><script src="/_next/static/chunks/5598-f6406abe053d9088.js" defer=""></script><script src="/_next/static/chunks/3883-27b9e22a816fd373.js" defer=""></script><script src="/_next/static/chunks/3120-cd163c5358cfe36c.js" defer=""></script><script src="/_next/static/chunks/2380-b4b6b8155f94a760.js" defer=""></script><script src="/_next/static/chunks/pages/article/%5Bidentity%5D/%5B%5B...version%5D%5D-62a48461fc1b6186.js" defer=""></script><script src="/_next/static/BY0jLfL5JqTU-Xr7tfWvz/_buildManifest.js" defer=""></script><script src="/_next/static/BY0jLfL5JqTU-Xr7tfWvz/_ssgManifest.js" defer=""></script><style id="__jsx-1810699180">.jsx-1810699180:export{white:#FFFFFF;grey10:#FAFAFA;grey20:#F2F2F3;grey30:#E5E6E8;grey40:#CCCFD2;grey50:#B2B7BC;grey60:#999FA6;grey65:#7F8790;grey70:#66707A;grey80:#33404E;grey90:#192837;black:#001122;g1:#F3FBF6;g2:#3AAE74;g3:#319767;g4:#268455;g5:#20734D;b1:#F2F6FB;b2:#186EC4;b3:#175089;b4:#1B4064;b5:#15324E;y1:#FFFCEB;y2:#EBCC5F;orange:#E9BE5C;}#search-button.jsx-1810699180{pointer-events:auto;}#search-input.jsx-1810699180{font-size:14px;padding-top:1rem;padding-bottom:1rem;-webkit-letter-spacing:0.3px;-moz-letter-spacing:0.3px;-ms-letter-spacing:0.3px;letter-spacing:0.3px;}#search-input.jsx-1810699180::-webkit-input-placeholder{color:#66707A;}#search-input.jsx-1810699180::-moz-placeholder{color:#66707A;}#search-input.jsx-1810699180:-ms-input-placeholder{color:#66707A;}#search-input.jsx-1810699180::placeholder{color:#66707A;}#search-button.jsx-1810699180{padding-bottom:0.3rem;}#search-button.jsx-1810699180:disabled{pointer-events:none;}#search-icon.jsx-1810699180{color:#CCCFD2;}#search-icon.jsx-1810699180:hover{color:#66707A;}#search-spinner.jsx-1810699180{color:#66707A;}</style></head><body><noscript><iframe src="https://www.googletagmanager.com/ns.html?id=GTM-K279D39R" height="0" width="0" style="display:none;visibility:hidden" /></noscript><div id="__next"><div class="no-scroll"><div class="original-css"><nav class="rs-navbar false false " role="navigation" aria-label="navigation"><div class="rs-container rs-ph"><div class="left"><div class="hamburger hamburger--squeeze false false" role="navigation"><div class="hamburger-box"><div class="hamburger-inner"></div></div></div><a href="/"><img class="logo-rs" src="/static/img/logos/logo-rs.svg" alt="Research Square"/></a><form class="jsx-1810699180 b-pl-10"><div class="jsx-1810699180 control has-icons-right lg:tw-w-96 md:tw-w-52"><input type="text" placeholder="Search preprints" id="search-input" class="jsx-1810699180 input"/><button disabled="" id="search-button" type="submit" class="jsx-1810699180 icon is-small is-right rounded-r-md"><i id="search-icon" class="jsx-1810699180 fas fa-search"></i></button></div></form></div><div class="right"><div class="nav-link"><h6>Browse</h6><i class="fas fa-caret-down"></i><div class="nav-dropdown"><div class=""><a href="/browse"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Preprints</h6></div></a></div><div class=""><a href="/coronavirus"><div class="nav-link "><h6 class="align" style="text-wrap:initial">COVID-19 Preprints</h6></div></a></div><div class=""><a href="/browse?journal=protocol-exchange"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Protocols</h6></div></a></div><div class=""><a href="/browse?articleType=Video"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Videos</h6></div></a></div><div class=""><a href="/journals"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Journals</h6></div></a></div><div class="b-mb-15"></div></div></div><div class="nav-link"><h6>Tools & Services</h6><i class="fas fa-caret-down"></i><div class="nav-dropdown"><div class=""><a href="/researchers/overview"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Overview</h6></div></a></div><div class=""><a href="/researchers/curie"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Curie</h6></div></a></div><div class=""><a href="/researchers/editing"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Professional Editing</h6></div></a></div><div class=""><a href="/researchers/promotion"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Research Promotion</h6></div></a></div><div class="b-mb-15"></div></div></div><div class="nav-link"><h6>About</h6><i class="fas fa-caret-down"></i><div class="nav-dropdown"><div class=""><a href="/researchers/preprints"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Preprint Platform</h6></div></a></div><div class=""><a href="/researchers/in-review"><div class="nav-link "><h6 class="align" style="text-wrap:initial">In Review</h6></div></a></div><div class=""><a href="/legal/editorial"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Editorial Policies</h6></div></a></div><div class=""><a href="/research-quality-evaluation"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Research Quality Evaluation </h6></div></a></div><div class=""><a href="/about"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Our Team</h6></div></a></div><div class=""><a href="/advisory-board"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Advisory Board</h6></div></a></div><div class=""><a href="https://support.researchsquare.com" target="_blank" rel="noopener noreferrer"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Help Center</h6></div></a></div><div class="b-mb-15"></div></div></div><div class=""><a href="/login"><div class="nav-link "><h6 class="align" style="text-wrap:initial">Sign In</h6></div></a></div><div class="b-pl-10"><a class="button color-button-g3 " href="/submit"><i class="button-icon fas fa-plus"></i>Submit a Preprint</a></div></div></div></nav></div><div class="rs-container"><div class="tw-mt-12 "><div class=""><div class="tw-max-w-[1600px] tw-mx-auto"><div class="lg:tw-grid lg:tw-grid-cols-10 lg:tw-grid-flow-col"><div class="tw-min-h-screen tw-col-span-6"><div class="tw-flex tw-justify-center lg:tw-justify-start lg:tw-border-r-2 lg:tw-border-gray-50"><div class="tw-max-w-reading tw-w-full tw-overflow-x-scroll _rs-scrollbar lg:tw-pb-20 lg:tw-px-4 lg:tw-pt-2 xl:tw-px-8"><div class="tw-flex tw-pr-4 lg:tw-pr-0 tw-mt-4 lg:tw-hidden tw-pl-3 tw-justify-end"><div class="tw-pr-3"><div class="tw-relative tw-inline-block tw-text-left"><div><button class="tw-group tw-inline-flex tw-items-center tw-px-3 tw-py-2 tw-transition-all tw-border-2 tw-rounded-md tw-group tw-bg-white tw-border-gray-100 hover:tw-bg-gray-100 focus:tw-outline-none" id="headlessui-menu-button-:Rk9l6:" type="button" aria-haspopup="true" aria-expanded="false"><svg xmlns="http://www.w3.org/2000/svg" class="tw-w-5 tw-h-5 tw-text-gray-600" fill="none" viewBox="0 0 24 24" stroke="currentColor"><path d="M16.6187 6.07577C17.6476 6.07404 18.4714 6.44992 19.09 7.20342C19.6858 7.97982 19.9846 8.89392 19.9864 9.94571C19.9879 10.8146 19.8292 11.6266 19.5103 12.3816C19.1915 13.1367 18.7925 13.8234 18.3134 14.4415C17.8114 15.0597 17.2864 15.5979 16.7385 16.0562C16.1676 16.5373 15.6424 16.9383 15.1628 17.2592C14.6832 17.603 14.2949 17.8552 13.998 18.0158C13.6781 18.1763 13.5296 18.2566 13.5525 18.2566L12.7619 17.1947C12.9675 17.1029 13.2416 16.9195 13.5841 16.6446C13.9266 16.3925 14.2691 16.0832 14.6114 15.7168C14.9309 15.3504 15.2161 14.9498 15.4668 14.5149C15.7177 14.1029 15.8427 13.7026 15.8421 13.3139C15.8417 13.0852 15.7041 12.8568 15.4294 12.6286C15.1546 12.4233 14.857 12.1723 14.5363 11.8756C14.2158 11.6017 13.9179 11.2593 13.6429 10.8482C13.3678 10.4599 13.2298 9.97999 13.2289 9.40837C13.228 8.90534 13.3301 8.44786 13.5352 8.03595C13.7175 7.62407 13.9684 7.26924 14.288 6.97145C14.5848 6.69657 14.9388 6.47875 15.3501 6.318C15.7614 6.15725 16.1843 6.07651 16.6187 6.07577ZM7.29256 6.02144C7.81845 6.02055 8.29881 6.13406 8.73363 6.36198C9.16845 6.58989 9.54624 6.89793 9.86701 7.28609C10.1878 7.67426 10.44 8.1197 10.6238 8.62242C10.7848 9.14805 10.8657 9.7081 10.8667 10.3026C10.8687 11.4916 10.6191 12.5895 10.1178 13.5964C9.5936 14.6262 9.02346 15.5075 8.40734 16.2402C7.67713 17.1103 6.84389 17.9006 5.90763 18.611L4.91144 17.6866C5.11699 17.5491 5.36814 17.3314 5.66488 17.0337C5.93876 16.736 6.20111 16.3811 6.45192 15.9691C6.67992 15.5801 6.88501 15.1681 7.06719 14.7334C7.22651 14.2987 7.30583 13.8756 7.30513 13.464C7.30467 13.1896 7.13279 12.9612 6.78951 12.7789C6.44623 12.5966 6.06857 12.3686 5.65653 12.0949C5.2445 11.8212 4.86663 11.4674 4.52292 11.0336C4.17925 10.6226 4.00678 10.0398 4.00551 9.28526C4.00473 8.82796 4.09548 8.4048 4.27774 8.01579C4.46 7.62677 4.71094 7.28337 5.03055 6.98559C5.32729 6.68784 5.68129 6.44716 6.09255 6.26355C6.48099 6.10283 6.88099 6.02213 7.29256 6.02144Z" stroke="currentColor" fill="currentColor"></path></svg><p class="tw-antialiased tw-hidden tw-ml-2 tw-text-sm tw-font-bold tw-text-gray-700 group-hover:tw-underline md:tw-block lg:tw-hidden xl:tw-block">Cite</p></button></div></div></div><div class="last:tw-pr-0"><div class="tw-relative tw-inline-block tw-text-left"><div><button class="tw-group tw-inline-flex tw-items-center tw-px-3 tw-py-2 tw-transition-all tw-border-2 tw-rounded-md tw-group tw-bg-white tw-border-gray-100 hover:tw-bg-gray-100 focus:tw-outline-none" id="headlessui-menu-button-:Rm9l6:" type="button" aria-haspopup="true" aria-expanded="false"><svg xmlns="http://www.w3.org/2000/svg" fill="none" viewBox="0 0 24 24" stroke-width="2" stroke="currentColor" aria-hidden="true" class="tw-w-5 tw-h-5 tw-text-gray-600"><path stroke-linecap="round" stroke-linejoin="round" d="M8.684 13.342C8.886 12.938 9 12.482 9 12c0-.482-.114-.938-.316-1.342m0 2.684a3 3 0 110-2.684m0 2.684l6.632 3.316m-6.632-6l6.632-3.316m0 0a3 3 0 105.367-2.684 3 3 0 00-5.367 2.684zm0 9.316a3 3 0 105.368 2.684 3 3 0 00-5.368-2.684z"></path></svg><p class="tw-antialiased tw-hidden tw-ml-2 tw-text-sm tw-font-bold tw-text-gray-700 group-hover:tw-underline md:tw-block lg:tw-hidden xl:tw-block">Share</p></button></div></div></div><a href="https://www.researchsquare.com/article/rs-3994852/v1.pdf?c=1709236367000" target="_blank" rel="noopener noreferrer" class="tw-text-blue-600 hover:tw-text-blue-800 hover:tw-underline tw-inline-flex tw-items-center tw-px-3.5 tw-py-1.5 tw-transition-all tw-border-2 tw-rounded-md tw-group tw-border-blue-50 tw-bg-blue-50 hover:tw-bg-blue-100 hover:tw-border-blue-100 focus:tw-outline-none tw-text-blue-600 hover:tw-text-blue-800 hover:tw-underline tw-ml-3"><svg xmlns="http://www.w3.org/2000/svg" fill="none" viewBox="0 0 24 24" stroke-width="2" stroke="currentColor" aria-hidden="true" class="tw-w-5 tw-h-5"><path stroke-linecap="round" stroke-linejoin="round" d="M12 10v6m0 0l-3-3m3 3l3-3m2 8H7a2 2 0 01-2-2V5a2 2 0 012-2h5.586a1 1 0 01.707.293l5.414 5.414a1 1 0 01.293.707V19a2 2 0 01-2 2z"></path></svg><span class="tw-antialiased tw-ml-2 tw-text-sm tw-font-bold"><span class="tw-hidden xl:tw-contents">Download</span> PDF</span></a></div><div class="tw-py-4 tw-border-b-2 tw-border-gray-100"><div class="tw-px-4"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black tw-pb-2">Method Article</p><h1 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-2xl sm:tw-text-3xl"><p><em>Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays</em></p></h1></div></div><div class="tw-px-4"><div class="tw-flex tw-items-start tw-justify-between"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-3 tw-w-full"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black">Paul V. Lehmann, Alexey Y. Karulin, Noémi Becza, Lingling Yao, and 9 more</p></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div></div><div class="tw-py-3 md:tw-px-1.5 tw-border-gray-100 tw-bg-gray-50 lg:tw-bg-white lg:tw-border-0 lg:tw-px-0 lg:tw-py-0"><div class="tw-mx-2.5 lg:tw-mx-0 tw-border-2 tw-border-gray-100 tw-bg-white tw-rounded-lg lg:tw-mb-1 tw-max-w-xl lg:tw-max-w-none"><div class="tw-px-4"><button type="button" class="tw-min-w-full focus:tw-outline-none tw-group"><div class="tw-flex tw-items-center tw-justify-between"><div class="tw-w-full tw-py-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-red-800 tw-font-bold">This is a preprint; it has not been peer reviewed by a journal.</p></div><div class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-red-700 tw-text-white tw-my-2 tw-flex tw-items-center tw-duration-300 tw-transform tw-bg-red-50 group-hover:tw-bg-red-100"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black tw-text-red-800 group-hover:tw-text-red-900 tw-flex"></p><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-text-red-800 group-hover:tw-text-red-900 tw-h-6 tw-w-6 tw-flex-shrink-0 tw-rounded-full tw-transform tw-duration-300"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-px-4"><div class="tw-border-t-2 tw-border-gray-100 tw-py-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black">https://doi.org/<!-- -->10.21203/rs.3.rs-3994852/v1</p><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black">This work is licensed under a <!-- -->CC BY 4.0<!-- --> License</p></div></div></div><div class="tw-mx-2.5 lg:tw-mx-0 tw-border-2 tw-border-gray-100 tw-bg-white tw-rounded-lg lg:tw-hidden tw-max-w-xl lg:tw-max-w-none tw-mt-3 tw-mb-0"><div class="tw-px-4"><button type="button" class="tw-min-w-full focus:tw-outline-none tw-group"><div class="tw-flex tw-items-center tw-justify-between"><div class="tw-w-full tw-py-2"><div class="tw-flex tw-items-center"><h3 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-base">Status:</h3><div class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700 tw-ml-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-color-gray-800">Posted</p></div></div></div><div class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700 tw-my-2 tw-flex tw-items-center tw-duration-300 tw-transform tw-bg-gray-100 group-hover:tw-bg-gray-200"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black tw-text-gray-800 group-hover:tw-text-gray-900 tw-flex"></p><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-text-gray-800 group-hover:tw-text-gray-900 tw-h-6 tw-w-6 tw-flex-shrink-0 tw-rounded-full tw-transform tw-duration-300"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-px-4 tw-border-t-2 tw-border-gray-100"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><div class="tw-py-2"><div class="tw-text-left"><h3 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-base">Version <!-- -->1</h3><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black tw-text-gray-700">posted<!-- --> </p></div></div></div><div class="tw-pt-1"><div class="tw-pb-1"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700 tw-flex tw-justify-center tw-w-full tw-mb-2">You are reading this <!-- -->latest<!-- --> <!-- -->preprint<!-- --> version</span></p></div></div></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">Abstract</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><p>Owing to their ability to reliably detect even very rare antigen-specific B cells in cellular isolates such as peripheral blood mononuclear cells (PBMC), and doing so robustly in a high throughput-compatible manner, B cell ELISPOT/FluoroSpot (collectively “B cell ImmunoSpot”) tests have become increasingly attractive for immune monitoring in regulated settings. Presently, there are no guidelines for the qualification and validation of B cell ImmunoSpot assay results. Here, we propose such guidelines, building on the experience acquired from T cell ImmunoSpot testing in an environment adhering to the requirements of regulatory bodies yet taking the unique features of B cell assays into account. A streamlined protocol is proposed that permits the performance of all tests needed for the formal validation of an antigen-specific B cell ImmunoSpot assay in only three experiments, utilizing 2.2 x 10<sup>7</sup> PBMC per donor. Subsequently, utilizing only 1–2 x 10<sup>6</sup> PBMC per sample (obtainable from 1–2 mL of blood), a validated multiplexed assay enables accurate quantification of the frequency of antigen-specific memory B cell-derived blasts secreting IgM, IgG, IgA or IgE antibodies. Collectively, such multiplexed B cell ImmunoSpot assays offer immense value for B cell immune monitoring programs due to their ease of implementation, scalability, applicability to essentially any antigenic system, economy of PBMC utilization, and last but not least, the high content information gained.</p></div></span></div><div class="tw-flex tw-flex-wrap tw-pb-3"><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><a href="/browse?subjectArea=Immunology" class="tw-text-blue-600 hover:tw-text-blue-800 hover:tw-underline"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-blue-50 hover:tw-bg-blue-100 tw-transition">Immunology</span></a></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">ELISPOT</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">FluoroSpot</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">B cells</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">immune monitoring</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">immune memory</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">Ig class</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">IgG subclass</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">high throughput</span></p></div><div class="tw-my-2 tw-mr-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700">antibody-secreting cell</span></p></div></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">1.0. Introduction</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><p>Despite the fact that the ELISPOT assay system was first developed for quantifying the abundance of antigen-specific antibody-secreting B cells (ASC) [<span citationid="CR1" class="CitationRef">1</span>, <span citationid="CR2" class="CitationRef">2</span>], it is the T cell ImmunoSpot assay (Note 1; a link to all “Notes” can be found at the end of this paper, under “<span refid="Sec37" class="InternalRef">Appendix</span>”) which were introduced much later [<span citationid="CR3" class="CitationRef">3</span>], that has become a mainstay for T cell immune monitoring [<span citationid="CR4" class="CitationRef">4</span>]. This happened after modification of the original T cell ELISPOT protocol enabled the assay to reliably reveal secretory footprints of individual antigen-specific T cells ([<span citationid="CR5" class="CitationRef">5</span>, <span citationid="CR6" class="CitationRef">6</span>], and Note 2), and the development of automated, objective, and validated machine reading approaches rendered the assay suitable for high throughput analysis and compliant with regulatory guidelines [<span citationid="CR7" class="CitationRef">7</span>, <span citationid="CR8" class="CitationRef">8</span>] (Note 3). The urgent need for measuring the contribution of the T cell compartment to immune responses, coupled with the ease of standardization, high sensitivity, and high throughput capacity together rendered T cell ImmunoSpot assays an attractive alternative to flow cytometry-based analysis (both being used initially for basic discovery, and now increasingly for clinical analysis [<span additionalcitationids="CR10 CR11 CR12" citationid="CR9" class="CitationRef">9</span>–<span citationid="CR13" class="CitationRef">13</span>].</p> <p>In contrast to T cell assays, to date, B cell ImmunoSpot assays have not been intensively exploited in either the basic research or clinical arenas. Perhaps the main technical reason for this is that the original B cell ImmunoSpot protocol was suitable for only a limited set of antigens. However, recently, this problem has been overcome with the implementation of an affinity capture coating approach [<span citationid="CR14" class="CitationRef">14</span>], which enables rapid development of ImmunoSpot assays for essentially any desired antigen. On the other hand, it is also likely that there was a major conceptual reason that B cell ImmunoSpot assays were not exploited: there has been the widely-held belief that sufficient information on B cell immunity could be obtained by simple measurements of serum antibodies, a notion that rendered it unnecessary to struggle with complex, fragile, and more difficult to preserve cell samples. However, this view is no longer tenable since we have learned that detection of memory B cells (B<sub>mem</sub>) reflects the existence of antigen-specific immunity in infectious- [<span citationid="CR15" class="CitationRef">15</span>, <span citationid="CR16" class="CitationRef">16</span>] and autoimmune- [<span citationid="CR17" class="CitationRef">17</span>] settings much more reliably than measurements of serum antibodies. Moreover, with serum antibodies possessing a half-life of only weeks (Note 4), and the plasma cells that replenish them apparently also having shorter lifespans than originally believed [<span citationid="CR18" class="CitationRef">18</span>], we now understand that in some instances serum antibodies only provide evidence of quite recent immune encounters [<span additionalcitationids="CR20 CR21" citationid="CR19" class="CitationRef">19</span>–<span citationid="CR22" class="CitationRef">22</span>]. In contrast, B<sub>mem</sub> are long-lived and thus not only enable a rapid antibody response upon antigen reencounter, but they can also undergo further refinement of their fine specificity to accelerate the response to new antigenic challenges, e.g., when encountering variant viruses (reviewed in [<span citationid="CR23" class="CitationRef">23</span>]). Newly developed modifications of B cell ImmunoSpot assays also permit the assessment of B<sub>mem</sub> cross-reactivity at single-cell resolution [<span citationid="CR24" class="CitationRef">24</span>] as well as the detailed investigation of the affinity distribution/maturation of an antigen-specific B<sub>mem</sub> repertoire [<span citationid="CR25" class="CitationRef">25</span>]. Although immune monitoring assays that enable the characterization of antigen-specific B cells, whether based on flow cytometry or ImmunoSpot assays, have already been available for some time in the research arena, adapting such complex assays for use in the clinical realm has been challenging at several levels. In particular, although guidelines for compliance with industry standards in a regulated environment have been developed for measurements of soluble analytes in liquids [<span citationid="CR26" class="CitationRef">26</span>], they require adaptation for cell-based test systems. This has already been accomplished for T cell ImmunoSpot assays [<span citationid="CR4" class="CitationRef">4</span>, <span citationid="CR27" class="CitationRef">27</span>] that enumerate antigen-specific T cells within PBMC by detecting cytokines secreted upon specific antigen encounter. Subsequently, T cell ImmunoSpot testing has become an assay of choice for evaluation of cell-mediated immune responses in many clinical trials [<span additionalcitationids="CR10 CR11 CR12" citationid="CR9" class="CitationRef">9</span>–<span citationid="CR13" class="CitationRef">13</span>]; however, such guidelines do not yet exist for B cell ImmunoSpot assays.</p> <p>Supplemental Fig. 1 depicts distinct types of B cell ImmunoSpot assays used for immune monitoring purposes (a link to all “Supplemental Figures” can be found at the end of this paper, under “<span refid="Sec37" class="InternalRef">Appendix</span>”). Because these assays differ fundamentally from T cell ImmunoSpot tests in many aspects, here we describe B cell ImmunoSpot assay development, qualification, and validation recommendations that build on those developed for T cell ImmunoSpot assays but take into consideration the distinguishing features of B cell biology. In doing so, we first outline these distinguishing features; then, following the definitions and experimental templates provided by Bauer <em>et al</em>. [<span citationid="CR4" class="CitationRef">4</span>] for T cell ImmunoSpot assays, we provide recommendations for B cell ImmunoSpot assay protocols. As a model for B cell ImmunoSpot assay development, qualification, and validation, we leveraged the SARS-CoV-2 Spike (S)-antigen-specific B cell response elicited following SARS-CoV-2 infection and/or COVID-19 mRNA vaccination of “naïve” subjects.</p></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">2.0 Theoretical considerations for the verification and validation of antigen-specific B cell ImmunoSpot assays.</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><div id="Sec3" class="Section2"> <h2>2.1. B cell biology-dictated implications for verification/validation</h2> <p>There is a considerable gap between the terminology used by basic scientists (in whose realm antigen-specific B cells assays are primarily used presently, and from where knowledge gained thus far needs to be transferred) and the regulated world (that increasingly attempts to adopt such cellular assays for clinical trial monitoring and diagnostics). Therefore, in this communication we will always begin with defining the terminology used in the regulated space so that it also becomes transparent to basic scientists as well.</p> <p>B cells are the only cell type capable of secreting antibody (immunoglobulin, Ig). Moreover, those B cells that have responded in a T helper cell-dependent manner can switch from secreting IgM molecules (produced by naïve B cells) to the production of the other Ig classes: namely, IgA (subclasses IgA1 and IgA2), IgE, and IgG (subclasses IgG1-IgG4) (Note 5 & 6). Importantly, B<sub>mem</sub> are resting lymphocytes that do not spontaneously secrete antibodies but can do so rapidly following (re-)activation by antigen. This is typically also dependent on antigen-specific, cognate T cell help <em>in vivo</em> but in addition it can be induced <em>in vitro</em> following stimulation with certain mitogens capable of activating all B cells polyclonally (i.e., regardless of their intrinsic antigen specificity). Such polyclonal stimulation is required to detect resting B<sub>mem</sub> by ImmunoSpot <em>ex vivo</em> (Note 7). Under these conditions, B<sub>mem</sub> transition, over the course of several days (optimally 5 days, Supplemental Fig. 2A-F), into ASC. Consequently, one can safely conclude that detecting any number of (even a single) antigen-specific ASC that produced class-switched Ig following polyclonal stimulation of PBMC identifies the presence of antigen-specific B<sub>mem</sub>. Even if cross-reactive, such B<sub>mem</sub> can give rise to a rapid-onset secondary immune response. The immune system operates very efficiently with low numbers of memory lymphocytes (Note 8).</p> <p>As resting B<sub>mem</sub> do not spontaneously secrete antibody, antigen-specific ASC are rarely detectable in freshly isolated blood (except a few weeks after initiation of an immune response, see below). This is the case even if antigen-specific B<sub>mem</sub> are found to be abundant in that sample after <em>in vitro</em> mitogenic stimulation (i.e., after the B<sub>mem</sub> have been polyclonally activated to become ASC, as illustrated on a sample isolated > 125 days following recovery from SARS-CoV-2 infection in Supplemental Fig. 3A <em>vs.</em> B). However, ~ 1 week after antigen exposure <em>in vivo</em>, ASC can be detected directly <em>ex vivo</em> in the blood (Supplemental Fig. 3C and D). Such ASC are not B<sub>mem</sub> cells; they are plasmablasts that appear in the blood as they migrate from the lymphoid tissue in which they became activated to the bone marrow and other immunological niches where they may become resident as plasma cells (PC). Such ASC can readily be detected in ImmunoSpot assays by seeding the PBMC into the test system without prior <em>in vitro</em> polyclonal stimulation. Of note, most of these plasmablasts are specific for the antigen that triggered the immune response <em>in vivo</em> (Supplemental Fig. 3C and D).</p> <p>Detecting such spontaneously antibody-secreting antigen-specific plasmablasts has considerable and thus far largely unexploited immunodiagnostic potential. In the case of B cell-mediated autoimmune conditions; for example, the appearance of these cells can reveal a flare of the disease [<span citationid="CR17" class="CitationRef">17</span>]. Similarly, it is likely to reflect on the reactivation of latent viruses in an immune compromised state (e.g., Cytomegalovirus or Epstein-Barr virus) or might indicate the initiation of transplant rejection episodes. While the appearance of peripheral blood ASC secreting Ig classes/subclasses other than IgA or IgM (see Note 9) by itself already documents an ongoing immune response, knowledge of the specificity of these ASC offers so far underutilized opportunities for identifying the antigen(s) that trigger(s) untoward immune responses. Examples are identifying the autoantigens in autoimmune diseases, environmental agents causing allergic reactions, and those responsible for flares of inflammation due to reactivation of persisting infections. Inherent challenges with such assessments are the transient appearance of such antibody-secreting plasmablasts in the blood, as well as the possibility that ASC in some conditions may reside predominantly in the tissue and therefore would not be present in the blood.</p> <p>Antigen-specific B cell ImmunoSpot assays for detecting such circulating plasmablasts or B<sub>mem</sub> differ only in the nature of the PBMC (or other cell isolate) to be tested; for the former, the cells are seeded into the ImmunoSpot test plates without any additional treatment, whereas for the latter, the cells are plated after 5 days of <em>in vitro</em> polyclonal stimulation. In both cases, the scope of the assay is the same: to determine unambiguously the number/frequency of antigen-specific ASC producing a certain Ig class/subclass within either all cells plated, or within all B cells secreting that Ig class/subclass (Note 10).</p> </div> <div id="Sec4" class="Section2"> <h2>2<em>.2. Assay optimization for detecting antigen-specific ASC at single cell resolution</em></h2> <p>The overall scope for optimizing B cell ImmunoSpot assays can be broken down into two separate components. The first can be readily accomplished: detecting plate-bound antibody secretory footprints generated by individual ASC once the capture conditions for these antibodies have been optimized. The second is more challenging: the coating of the antigen itself to the membrane at a sufficiently high density for the antigen-specific Ig released by ASC to be efficiently captured on the membrane. Fulfilling this latter requirement has caused considerable challenges in the past, but these have now been overcome by the technique of affinity coating of the antigen [<span citationid="CR14" class="CitationRef">14</span>]. (See also Supplemental Fig. 1, A <em>vs</em>. B),</p> <p>Supplemental Fig. 4A shows secretory footprints that were generated by a murine B cell hybridoma when incubated on a membrane coated with high-affinity anti-mouse Igk capture antibody (of goat origin; for a description of this type of assay refer to Supplemental Fig. 1, panel C). When high-affinity anti-mouse IgG detection antibodies are used to visualize the plate-bound murine (B cell hybridoma-derived) antibody, pristine spot-forming units (SFU) become visible. Plating the hybridoma cells in serial dilution and counting the resulting SFU using a suitable reader reveals a near perfect linear relationship between the number of hybridoma cells plated per well and the number of SFU detected per well within a defined cell input range, revealing that 56% of the hybridoma cells were capable of generating a secretory footprint during the assay incubation period (Supplemental Fig. 4C, Notes 11 & 12). Supplemental Fig. 4D shows secretory footprints generated by B cell blasts (following <em>in vitro</em> polyclonal stimulation of PBMC) detected in an analogous manner using species-specific detection reagents; with these too, cell numbers plated and SFU counts detected precisely follow a linear function (Supplemental Fig. 4F). In both instances, the spot morphologies originating from the hybridomas or the B cell blasts exhibit very similar profiles in their size, shape, and density. Such data establish that the per cell antibody productivity of the hybridomas and that of B cell blasts during the analyte capture period of the assay were both clearly detectable. Therefore, the verification that secretory footprints originating from single hybridoma cells are being visualized implies the same for the detection of human ASC. In other words, these types of tests verify that the detection reagents used indeed detect secretory footprints of individual ASC. To control for the quality of the detection reagents’ performance, we recommend the inclusion of positive controls in which polyclonally stimulated PBMC (because of the high inter-individual variability among donors, preferably pre-characterized PBMC) reference samples [<span citationid="CR27" class="CitationRef">27</span>] are tested in serial dilution after pan Ig capture for Ig class/subclass-producing ASC (See Supplemental Fig. 5).</p> <p>The real challenge for antigen-specific B cell ImmunoSpot assay development has been efficient coating of the membrane with the antigen of interest. For detecting antigen-specific ASC, the membrane must be densely coated with antigen. The membrane best suited for ImmunoSpot analysis is a PVDF fibered filter [<span citationid="CR7" class="CitationRef">7</span>] that, due to its hydrophobicity and fractal surface structure, excels in binding proteins [<span citationid="CR28" class="CitationRef">28</span>], or to be more precise in this context, to bind proteins with sufficient hydrophobic regions, such as Ig. For such hydrophobic proteins, the classic, direct membrane-absorption-based coating strategy suffices for developing antigen-specific B cell ImmunoSpot assays. However, such proteins are more the exception than the rule amongst antigens of interest; and, for the remainder, affinity capture of the antigen greatly reduces the quantity of protein required to achieve the necessary coating density. This can be accomplished by coating the membrane first with an Ig [<span citationid="CR14" class="CitationRef">14</span>, <span citationid="CR15" class="CitationRef">15</span>, <span citationid="CR29" class="CitationRef">29</span>] or with an alternative capture protein that is sufficiently hydrophobic (see Supplemental Fig. 1B). This specific “antigen-capture reagent” will then bind with high affinity to the soluble antigen in solution (Note 13). For example, recombinant proteins are commonly engineered to contain a short amino acid sequence tag (e.g., His-tag) that facilitates their purification via affinity chromatography; the same tags can be used to achieve high density protein coating via plate-bound anti-tag capture antibodies [<span citationid="CR14" class="CitationRef">14</span>]. Notably, the anti-tag capture approach is far more universal than direct antigen coating as it enables the high affinity capture of different unrelated proteins that need only to share a common affinity tag. Therefore, the recent introduction of affinity capture coating has made detection of antigen-specific ASC via B cell ImmunoSpot analysis a generalizable immune monitoring tool (Note 14); failed past attempts with direct coating are likely one reason that this simple and powerful B cell ImmunoSpot technology did not find its place in the standard immune monitoring repertoire until now.</p> <p>As a rule of thumb, coating the PVDF membrane with 10 µg/mL of antigen-capture antibody, and then adding the antigen itself at 10 µg/mL will result in high density antigen coating. However, as both reagents are unique to the type of (or even batch of) antibody and antigen used, titrating both during the assay development phase is highly recommended for obtaining optimal antigen coating while also minimizing the amount of antigen-capture antibody and antigen required. Supplemental Fig. 6 shows spot morphologies seen with suboptimal vs. optimal coating. Of note, not only does the spot morphology deteriorate with suboptimal coating (to the point of becoming vague or even undetectable), but, as the antigen-density on the membrane decreases, just the high affinity end of the antigen-specific B cell repertoire becomes detectable [<span citationid="CR25" class="CitationRef">25</span>]. When testing primary cell material containing B cells with different affinities for the antigen, coating can be considered optimal if a full spectrum of spot morphologies is detected, ranging from dense and sharp spots (produced by the high affinity end of the B cell repertoire) to small and faint, often also diffuse spots (representing the low affinity end of the repertoire); see also Supplemental Fig. 7 and Notes 15 & 16).</p> <p>For optimizing antigen coating conditions, reference PBMC are well-suited [<span citationid="CR27" class="CitationRef">27</span>] if available (Note 17). If unavailable, or when B cell reactivity to the antigen in question needs to be verified (as for autoimmunity or cancer, see Note 16), B cell hybridomas specific for that antigen can be used for antigen coating optimization. In case such hybridomas are not available, immunizing mice with the antigen of interest and testing the spleen cells of the immunized mice in a murine B cell ImmunoSpot assay is another option (Note 18). In either case, antigen coating optimization can be considered complete only if pristine spots are detected covering a wide range of sizes and morphologies (Note 19).</p> <p>We strongly advise principal investigators, study directors, auditors, and reviewers not to accept mere SFU counts as B cell ImmunoSpot data reports without visually verifying the quality of spots evaluated. Suitable analyzers will automatically retain raw well images and the results of the analysis as count overlays in a tamper-proof fashion, providing ease of access and transparent audit trails [<span citationid="CR8" class="CitationRef">8</span>].</p> </div> <div id="Sec5" class="Section2"> <h2>2.3. Count optimization for detecting secretory footprints of individual cells</h2> <div id="Sec6" class="Section3"> <h2>2.3.1. Counting parameters for machine reading</h2> <p>Once assay development for visualization of secretory footprints generated by individual antibody-secreting B cells has been accomplished, the next step is counting them by machine reading. These secretory footprints (which we also refer to as SFU) are readily countable by eye under a dissection microscope (ELISPOT) or a fluorescent microscope (FluoroSpot), but visual counting is, with these assays being high throughput and ideally high content in nature, tedious, imprecise, and leaves no audit trails. Based on theoretical modeling [<span citationid="CR30" class="CitationRef">30</span>] and as experimentally verified [<span citationid="CR25" class="CitationRef">25</span>], machine reading of direct B cell assays is needed to precisely resolve four distinct spot morphologies at the extremes and all transitions in between (see Supplemental Fig. 7D and [<span citationid="CR60" class="CitationRef">60</span>]). Regarding spot intensity (the first dimension), the brightest spots originate from ASC that produced high affinity antibodies for the antigen of interest, whereas faint or dim spots are generated by ASC secreting lower affinity antibodies. In the second dimension, spot sizes reflect per cell productivity (Note 20). Suitable software can accurately assess spot sizes and intensities (Supplemental Figs. 7B, C and D) and thus permit not only precise SFU counting, but also high content analysis for assessing the affinity spectrum of an antigen-specific B<sub>mem</sub>-derived ASC repertoire [<span citationid="CR25" class="CitationRef">25</span>] (Note 21).</p> <p>Due to clonal diversity of the naïve antigen-specific B cell repertoire originally engaged, and the subsequent emergence of subclones with diverse affinities for the antigen generated through the process of affinity maturation (Note 22), the antigen-specific B<sub>mem</sub> repertoire in most instances will include a wide spectrum of affinities. This can range from B cell receptors (BCR)/secreted antibodies with weak to very weak binding (K<sub>D</sub>>10<sup>− 4</sup>) to very strong (K<sub>D</sub><10<sup>− 11</sup>) [<span additionalcitationids="CR32 CR33 CR34 CR35 CR36 CR37" citationid="CR31" class="CitationRef">31</span>–<span citationid="CR38" class="CitationRef">38</span>], encompassing greater than a 10-million-fold potential difference in the binding strength of the BCR/antibody to antigen (Note 23). Overall, antibody affinity/avidity for antigen is (in addition to the Ig class/subclass) the critical determining factor for their biological effector potential (Note 24). As all B<sub>mem</sub> have passed an affinity-based selection criterion when the parental (germline) naïve B cell was first engaged in the immune response, and as the hypermutated subclones of those parental cells have in most cases undergone additional rounds of affinity-based positive selection (Note 22), the B<sub>mem</sub> repertoire secreting IgG, IgA, and IgE antibodies (Note 25) consists primarily of cells secreting Ig towards the higher affinity end of the spectrum. For optimized antigen-specific IgG (and IgA) assays, there are relatively few “ambiguous” spots observed in assays detecting B<sub>mem</sub>-derived ASC producing these class-switched antibodies in naïve vs immunized individuals (Supplemental Table 1 and Supplemental Fig. 8A) reflecting the individual’s antigen-primed status with near perfect accuracy. The analysis of IgM antibodies produced by broadly-reactive naïve B cells after <em>in vitro</em> polyclonal stimulation, however, provides a different level of conceptual and technical challenge (Note 26).</p> </div> </div> <div id="Sec7" class="Section2"> <h2>2.4 Accurate ASC frequency assessment</h2> <p>When measuring frequencies of B<sub>mem</sub>-derived antigen-specific ASC using the direct assay, we need to keep in mind that not only do the frequencies of ASC producing different Ig classes (and subclasses) span orders of magnitude, and additionally exhibit considerable variation among individuals [<span citationid="CR16" class="CitationRef">16</span>] and Supplemental Fig. 5), but also the number of antigen-specific B cells within each class/subclass spans a similarly wide range. A representative illustration of frequency variations for B<sub>mem</sub>–derived IgG<sup>+</sup> ASC specific for different antigens in a cohort of healthy subjects is provided in Supplemental Fig. 9. The data for this figure were obtained by seeding polyclonally stimulated PBMC at a fixed number of 3 x 10<sup>5</sup> PBMC per well for screening purposes. When analyzed in the context of Supplemental Fig. 10 (which shows that SFU counts > 100 per well are underestimating the actual number of ASC present in a sample), it becomes clear that testing samples at a single PBMC concentration precludes accurate frequency assessments; many of the data points obtained are either over or under the reliable quantification limit of the assay when a single cell concentration (e.g. 2 x 10<sup>5</sup> per well) is used for testing.</p> <div id="Sec8" class="Section3"> <h2>2.4.1 Upper quantification limit</h2> <p>The upper quantification limit of B cell ImmunoSpot assays is caused by overcrowding of the spots. While the individual ASC secretory footprints can be clearly visualized when there is sufficient space for each to be captured without overlap, this does not start to occur for antigen-specific assays until around 100 SFU per well (examples of which are shown in Supplemental Fig. 10) and for pan Ig assays (that display tighter footprints) at ~ 300 SFU per well (see Supplemental Fig. 4, and Note 27). In addition, as the number of ASC per well increases, the “ELISA effect” increases in magnitude. Specifically, the ELISA effect occurs due to an increased concentration of ASC-derived antigen-specific antibody in the supernatant that is captured on the antigen-coated membrane independent of the original cellular source. Consequently, the ELISA effect elevates the overall background staining of the assay membrane and interferes with the detection not only of faint spots, but also the outlines that define individual ASC-derived secretory footprints (Note 28). Defining the upper quantification limit (ULOQ) as the maximal number of ASC which can be detected in the assay well, is assay-dependent at ~ 100 SFU per well for antigen-specific, and ~ 300 SFU per well for pan Ig tests. However, the cells can be sufficiently diluted, as we suggest here – i.e. plating them in serial dilution as a simple and necessary solution to extend frequency measurements for PBMC samples without an upper quantification limit (Note 29). When testing PBMC for B<sub>mem</sub>-derived antigen-specific ASC, we recommend starting at 2 x 10<sup>5</sup> cells per well and progressing in a 1 + 1 dilution series (see Supplemental Fig. 5A). While SFU crowding may occur at the highest inputs of the cell titration for some test samples, in such cases the lower cell inputs will still follow a linear relationship between cell numbers plated and SFU counts. Using such a serial dilution approach also permits an accurate assessment of ASC frequency in the sample by averaging the frequencies calculated from each dilution point in the linear range (Supplemental Fig. 10) (Note 30).</p> </div> <div id="Sec9" class="Section3"> <h2>2.4.2. Lower detection limit and lower limit of quantification.</h2> <p>With regard to interpreting antigen-specific B cell ImmunoSpot test results, there are two basic questions to be answered. The first is qualitative: are there primed B<sub>mem</sub> present in an individual? The second is quantitative: what is the precise frequency of B<sub>mem</sub>-derived ASC within the PBMC test sample? Regarding the immunodiagnostic significance of the lower detection limit, it can be assumed that, if antigen-specific B<sub>mem</sub> are present, even at very low numbers, this can have a major impact for the individual host (Note 8). As antigen-specific B (and T) cells, can occur at low frequencies in antigen-primed individuals, often the aim is to lower the detection limit for antigen-specific ASC as much as possible.</p> <p>Despite not yet having studied this issue in depth, our experience gained so far indicates that if a single ASC producing antigen-specific IgG is plated, that this ASC will be reliably detected on the basis of its secretory footprint. Therefore, while the lower limit of quantification will depend on the number of PBMC assessed, and is thus specific for a particular assay protocol, there is no inherent lower limit of detection for such tests. If, for example, 10<sup>6</sup> PBMC are seeded per well into 100 replicate wells, the detection limit can be extended to be, in this case, 1 in 10<sup>8</sup> PBMC, provided there is no background noise.</p> <p>The general rule in the T cell field for detecting weak antigen-specific responses is that the mean number of antigen-specific SFU (established in 3–4 replicate wells at a single cell input) should be more than 1.65-fold the standard deviation of the SFU count in the control wells (established in 3–4 replicate wells at the same single cell input). As B cells are the only cell type capable of producing antibody, in antigen-specific B cell assays every spot counts. In future studies aiming to extend the lower detection threshold, it should be kept in mind that (unlike for T cell assays), in B cell assays, the Poisson distribution applies when analyzing low frequency ASC events (Supplemental Figs. 11 and 12). As to the lower limit of quantification for B cell ImmunoSpot assays in general, Poisson rules also apply (Supplemental Figs. 11 and 12). Here too, increasing the number of PBMC plated per well, along with the number of replicate wells, will increase the accuracy of frequencies determined in the very low frequency range.</p> <p>As frequencies of antigen-specific B<sub>mem</sub>-derived ASC span a wide range (Supplemental Fig. 9 and [<span citationid="CR16" class="CitationRef">16</span>, <span citationid="CR24" class="CitationRef">24</span>], it is recommended to test the PBMC first in a serial dilution, starting at 2 x 10<sup>5</sup> per well (Supplemental Fig. 5A); or, if the frequencies are anticipated to be lower, we recommend to start the serial dilution at 1 x 10<sup>6</sup> PBMC per well (cell material permitting) (Note 31). Should samples be outside of the range covered by this first approach and if extending the lower limit of detection is necessary for such samples, additional aliquots can be thawed (Note 32) in which the aforementioned testing of replicate wells with high cell numbers is applied to extend the lower limit of detection/qualification.</p> </div> <div id="Sec10" class="Section3"> <h2>2.4.3. Interpreting B<sub>mem</sub> presence and frequencies</h2> <p>As a first approximation, therefore, one could expect the frequency of B<sub>mem</sub> to be proportional to the magnitude of secondary antibody responses that these cells will generate upon antigen reencounter (Note 33). Similarly, even if an individual has not been exposed to a specific antigen (e.g., a new virus variant that emerges, a so-called heterotypic virus) but possesses cross-reactive B<sub>mem</sub> (e.g., induced by the original homotypic virus), such B<sub>mem</sub> can be expected to convey an elevated level of immune protection through their ability to rapidly differentiate into ASC and raise the level of specific antibody. Confirming this notion, lower B<sub>mem</sub> frequencies may correlate with the risk for vaccine breakthrough infection caused by the SARS-CoV-2 variants. Therefore, detecting any number of antigen-specific B<sub>mem</sub>-derived ASC (as identified by their production of class-switched antibodies), whether primed by the nominal antigen or a cross-reactive antigen, should be of immune diagnostic significance (Note 34). Refer to [<span citationid="CR24" class="CitationRef">24</span>] for measurements of B<sub>mem</sub> cross-reactivity at single-cell resolution using the B cell ImmunoSpot approach, and to an in-depth description of pre-formed antibody (the “first wall of B cell defense”) and B<sub>mem</sub>-mediated immunity (the “second wall of B cell defense”) as it relates to homo- vs. heterotypic immune defense [<span citationid="CR23" class="CitationRef">23</span>].</p> </div> </div> <div id="Sec11" class="Section2"> <h2>2.5. Accurate detection of Ig class</h2> <p>In addition to establishing the mere number of B<sub>mem</sub> present in the body, which reveals the existence and magnitude of immunological memory, it is also essential to define the Ig class (and/or subclass) these B<sub>mem</sub> will produce upon antigen encounter or reencounter. This is because immunoglobins of different Ig classes (and subclasses) mediate fundamentally different defense reactions, primarily due to their differential binding to Fc receptors and complement-activating properties (Note 35).</p> <p>Upon antigen (re-)encounter, and subsequent re-activation, B<sub>mem</sub> can rapidly differentiate into PC that secrete the same Ig class/subclass expressed by the parental B<sub>mem</sub>. Therefore, detecting the Ig class that B<sub>mem</sub>-derived ASC produce in ImmunoSpot assays permits the specific type(s) of antibody that will be produced following the next antigen encounter to be predicted. Knowledge of the full spectrum of Ig classes that the antigen-specific B<sub>mem</sub> repertoire will produce is essential for predicting the protective efficacy of future antibody responses to a “specific” antigen. Moreover, such B cell ImmunoSpot assays may also predict the likelihood of antibody-mediated complications occurring upon antigen re-exposure (e.g., causing allergic reactions or antibody-dependent enhancement leading to exacerbation of clinical disease [<span citationid="CR39" class="CitationRef">39</span>]. Importantly, the frequencies of antigen-specific B<sub>mem</sub> capable of secreting different Ig classes differ by orders of magnitude [<span citationid="CR16" class="CitationRef">16</span>, <span citationid="CR40" class="CitationRef">40</span>]. Thus, it is not only recommended to assess all antigen-specific Ig classes, but also to do so over a wide frequency range for each. The latter can readily be accomplished by combining the serial dilution strategy with 4-color ImmunoSpot analysis [<span citationid="CR40" class="CitationRef">40</span>] (Supplemental Figs. 5 and 13).</p> <div id="Sec12" class="Section3"> <h2>2.5.1 Four-color B cell ImmunoSpot analysis</h2> <p>Individual B cells can only express a single Ig class/subclass [<span citationid="CR41" class="CitationRef">41</span>]. Therefore (unlike T cell ImmunoSpot analysis), standard multi-color B cell ImmunoSpot analysis does not need to account for the co-expression of the different analytes (Ig classes or subclasses) studied. This basic biologic fact greatly facilitates objective identification of secretory footprints in multiplexed B cell assays, provided that the fluorochromes used only yield a signal in the corresponding detection plane and do not cross-bleed into the others (Supplemental Fig. 13 and Note 36). Such fluorochromes, which possess non-overlapping spectra, are used in CTL’s multi-color detection systems [<span citationid="CR42" class="CitationRef">42</span>]. Of note, the sensitivity of the enzymatic (single- or double-color) ELISPOT and of the (up to four-color) FluoroSpot modalities for quantifying individual B cell-derived Ig secretory footprints are similar [<span citationid="CR40" class="CitationRef">40</span>], see also Supplemental Fig. 14, and Note 37). For the comprehensive assessment of the antigen-specific B cell repertoire, we recommend performing a four-color assay to determine the major classes of secreted Ig (MAGE), and, in parallel, a four-color assay measuring individual IgG subclasses if cell material and coating antigen(s) are not limiting.</p> </div> </div> <div id="Sec13" class="Section2"> <h2>2.6. Optimization of PBMC utilization</h2> <p>The volume of blood available for cellular immune monitoring is often the limiting factor in clinical trials, particularly when it comes to obtaining PBMC from children and critically ill patients. Thus, devising the most efficient PBMC utilization protocols primarily defined our approach for comprehensive assessment of the antigen-specific B cell repertoire. Conventionally, cellular assays, including T cell ImmunoSpot tests, are performed using replicates, typically 3–4 replicate wells per test condition, from which means and standard deviations (SD) are established with the required level of precision. In the T cell assay, to become activated, very rare antigen-specific T cells must interact with antigen-presenting cells within the PBMC monolayer on the well bottom, triggering antigen-induced cytokine production. In contrast, in B cell ImmunoSpot tests, individual ASC are detected that are already producing Ig “spontaneously”, in a cell autonomous manner (no matter whether these B cells became activated <em>in vivo</em>, or whether resting B<sub>mem</sub> were subjected to <em>in vitro</em> polyclonal stimulation prior to testing in a B cell ImmunoSpot assay).</p> <p>Because pre-activated B cells do not require cell-cell contacts for secreting antibodies, the PBMC test samples can be diluted much further than in T cell assays (that strictly depend on T cell and antigen-presenting cell contacts) to obtain optimal (20–100) SFU counts. For frequency calculations, it is plausible that testing PBMC in serial dilution will provide similarly accurate ASC frequency measurements when done with a single well per cell input by calculating the frequency by averaging the results from several dilution points compared to establishing frequencies from the mean of replicate wells at each cell input. Extensive comparisons confirmed this assumption (Supplemental Fig. 15). Testing PBMC in single well serial dilutions for the initial frequency assessment in yet uncharacterized samples, therefore, allows the investigator to reduce the number of cells needed to 4.4 x 10<sup>5</sup> (with safety margin 5 x 10<sup>5</sup>) cells per antigen (when the serial dilution is started at 2 x 10<sup>5</sup> PBMC per well in a four-color IgM, IgA, IgG and IgE detection test). An illustration of a recommended well layout for such a B cell ImmunoSpot test is provided in Supplemental Fig. 5A. Note 38 provides suggestions for how to set up such serial dilutions in a streamlined manner. PBMC can be cryopreserved while maintaining full B cell functionality [<span citationid="CR43" class="CitationRef">43</span>], with 80–90% of the cells typically recovered after thawing. If the PBMC are to be tested for B<sub>mem</sub>-derived ASC reactivity after <em>in vitro</em> polyclonal stimulation, up to 50% cell loss can be expected (Supplemental Fig. 2H). Therefore, when working with cryopreserved cell material to detect B<sub>mem</sub>-derived ASC after 5 days of <em>in vitro</em> polyclonal stimulation (or plasmablasts directly <em>ex vivo</em>), cryopreserving cells at 1–2 x 10<sup>6</sup> PBMC per aliquot is minimally recommended per antigen (Note 38) – ideally, several such aliquots. The first aliquot will suffice for assessing the frequency of B<sub>mem</sub>-derived antigen-specific ASC producing one of the four Ig classes, including defining the overall numbers of ASC producing these Ig classes irrespective of their antigen specificity. Additional aliquots may be used for extending the lower detection limits, if that would be needed. Alternatively, affinity- [<span citationid="CR25" class="CitationRef">25</span>] or cross-reactivity [<span citationid="CR24" class="CitationRef">24</span>] assessments of the antigen-specific ASC repertoire could be performed using the remaining cell material, if desired. It should also be noted here that ASC survive the ImmunoSpot testing unharmed, and instead of discarding them at the end of the ImmunoSpot assay, they can be utilized for additional functional or genetic analyses.</p> </div></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">3.0. Validation of B cell ImmunoSpot Tests</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><p>According to the accepted definition, method validation is an evaluation process of the performance characteristics of an established analytical procedure through laboratory studies with all performance characteristics meeting the requirements of the intended analytical applications. In other words, an analytical method should be examined from a variety of aspects to prove that the test results can be trusted and appropriately applied to the intended quality objective.</p> <p>Following the guidelines for T cell ImmunoSpot assay validation [<span citationid="CR4" class="CitationRef">4</span>, <span citationid="CR27" class="CitationRef">27</span>], modified to accommodate the divergent features of B cell assays described above, we determined the (1) Specificity, (2) Accuracy, (3) Precision, (4) Detection Limits, (5) Qualification Limits, and (6) Linearity of our SARS-CoV-2 S-antigen-specific, 4-color Ig class (IgM/IgA/IgG/IgE, “MAGE”) B cell ImmunoSpot assay using the serial dilution variant. As B cell ImmunoSpot assays lend themselves to high throughput testing (Notes 38–43), in the following we will recommend a workflow and experimental design that permits the extraction of all the raw data needed for a full validation of the antigen-specific B cell ImmunoSpot test by performing only three relatively simple tests, requiring in total 2.2x10<sup>7</sup> PBMC; as outlined in Note 42 (see also Note 43).</p> <div id="Sec15" class="Section2"> <h2>3.1. Specificity</h2> <div id="Sec16" class="Section3"> <h2>3.1.1 Immunological specificity</h2> <p>Establishing antigen-specificity requires testing PBMC from negative control individuals (who have not been exposed yet to the antigen of interest) as compared to positive controls (those known to have been exposed). In the case of our example, the negative control tested the presence of B<sub>mem−</sub>derived ASC with reactivity for the S-antigen (representing the prototype Wuhan-Hu-1 strain of SARS-CoV-2 virus) in PBMC collected prior to the onset of the COVID pandemic (pre-COVID era). This was compared with the results of testing PBMC from individuals with PCR-verified SARS-CoV-2 infection before vaccines became available. We also tested PBMC collected from individuals 6 months after receiving two doses of COVID-19 mRNA vaccine (that encoded the Wuhan-Hu-1 S-antigen) before infections with SARS-CoV-2 variants became widespread. The non-infected status of these latter donors was verified by testing for SARS-CoV-2 Nucleocapsid (NCAP) antigen reactivity. Supplemental Table 1 shows the frequencies of Wuhan S-antigen-reactive B<sub>mem</sub>-derived ASC detected in these three cohorts. The data indicate that 100% of the vaccinated individuals and 100% of the subjects that recovered from PCR-verified SARS-CoV-2 infection, but none of the pre-COVID era samples, possessed B<sub>mem</sub>-derived IgG<sup>+</sup> ASC reactivity against the S-antigen at high or relatively high frequencies. Of note, the frequencies of pan IgG<sup>+</sup> (irrespective of antigen specificity) ASC measured in parallel were similar in the three cohorts, documenting that neither cryopreservation nor the duration of storage could account for the observed differences in S-antigen-specific IgG<sup>+</sup> ASC detected. In contrast, S-antigen “specific” IgM<sup>+</sup> ASC reactivity following polyclonal stimulation was detected in the positive and negative control cohorts alike (Supplemental Fig. 8B), implying broad reactivity and lack of specificity for <em>in vitro</em> induced IgM<sup>+</sup> ASC.</p> </div> <div id="Sec17" class="Section3"> <h2>3.1.2. Diagnostic specificity</h2> <p>The data in Supplemental Table 1 also establish the 100% diagnostic specificity of this B cell ImmunoSpot test for identifying individuals that received a COVID-19 mRNA vaccine or developed B cell memory following infection. While it may be more the exception than the rule, the S-antigen example we have selected here perfectly illustrates the immunological and diagnostic specificity of the IgG<sup>+</sup> B cell ImmunoSpot approach. Notably, in spite of some sequence conservation between the S-antigen encoded by SARS-CoV-2 and other coronaviruses causing common colds, we failed to detect B<sub>mem</sub>-derived ASC reactivity against the S-antigen of SARS-CoV-2 in any of the pre-COVID era samples. In contrast, B<sub>mem</sub>-derived IgG<sup>+</sup> ASC reactivity against recombinant hemagglutinin (rHA) antigens representing seasonal influenza vaccine strains were clearly detectable in these same assays in all cohorts (data not shown).</p> <p>Fast forwarding to the present, because most individuals have since either received multiple COVID-19 vaccinations and/or have been infected with one or more variant SARS-CoV-2 viruses, identifying an individual that is immunologically naïve to the prototype Wuhan-Hu-1 S-antigen has become quite rare in the population (Kirchenbaum, manuscript in preparation). As such, B<sub>mem</sub>-derived ASC reactivity against the S-antigen can potentially serve as a universal positive control for B cell ImmunoSpot testing, alongside influenza antigens, and probably many other antigens that originate from other viruses causing ubiquitous infections.</p> </div> <div id="Sec18" class="Section3"> <h2>3.1.3. Immunological interpretation of B<sub>mem</sub> or plasmablast specificity</h2> <p>The clarity of the data shown in Supplemental Table 1 (i.e., none of the SARS-CoV-2-naïve, but all the convalescent or vaccinated individuals display vigorous S-antigen-specific B cell memory) would imply a tremendous potential for B<sub>mem</sub> monitoring in immunodiagnostics. But to what extent are these findings likely to apply to antigens other than S-antigen of the prototype Wuhan-Hu-1 strain, where a clearly naïve vs. exposed state can be defined? And even when it comes to the S-antigen, does the marked difference seen between the naïve and antigen-primed state hold up for later time points when B cell memory has established itself, for example when desiring to monitor the impact of booster vaccinations? While these are the most fundamental questions for the immunodiagnostic interpretation of B cell ImmunoSpot results, the answers are still awaited. However, the observations we have already made anticipate some of these answers, as discussed in the following.</p> <p>Better understanding of B cell cross-reactivity <em>in vivo</em>, including affinity cut-offs, will be an issue. The B cell system has evolved to achieve remarkable specificity for the selective recognition of any given antigen. This is mediated through the enormous clonal diversity present in the naïve B cell repertoire which encodes ~ 10<sup>12</sup> BCR from which a small number of cells endowed with BCR specific for the antigen of interest (and with a sufficient affinity to be activated) are recruited into an immune response. Subsequently, the antigen-specificity of the B cell response is further improved by somatic hypermutation of the BCR expressed by the positively selected B cells participating in the germinal center reaction, which is then followed by further rounds of hypermutation and positive selection of the subclones which express BCR with the highest affinity for the antigen (a process termed “affinity maturation”) [<span citationid="CR44" class="CitationRef">44</span>]. While such highly specific B cells can immediately contribute to immune defense by differentiating into ASC and rapidly increasing the abundance of specific antibody (constituting the so-called “first wall” of B cell-mediated immunity [<span citationid="CR23" class="CitationRef">23</span>], we also need to keep in mind that the B cell system is adaptive and has evolved the ability to confer cross-reactive protection against antigenically-related pathogens in order to provide increased responsiveness to variant viruses (the so-called “second wall” of B cell-mediated immunity [<span citationid="CR23" class="CitationRef">23</span>].</p> <p>For example, as discussed above, we did not detect B<sub>mem</sub>-derived IgG<sup>+</sup> ASC with reactivity against the SARS-CoV-2 S-antigen in pre-COVID era PBMC samples (Supplemental Table 1), despite the fact that most likely everyone has been infected with related coronaviruses responsible for causing common colds [<span citationid="CR45" class="CitationRef">45</span>], and therefore could be expected to possess cross-reactive B<sub>mem</sub>. However, we found that ~ 40% of B<sub>mem</sub>-derived IgG<sup>+</sup> ASC with reactivity against the receptor binding domain (RBD) of the S-antigen expressed by the prototype Wuhan-Hu-1 strain, elicited by infection early in the COVID pandemic, cross-reacted with the RBD probe representing the BA.1 Omicron variant [<span citationid="CR24" class="CitationRef">24</span>]. Such PBMC samples were collected long before the emergence of the Omicron variant, which caused widespread infections, so this finding implies that some S-antigen epitopes targeted by such “cross-reactive” ASC remained conserved on the variant (BA.1) strain. Studies of pre-Omicron and post-Omicron PBMC using the BA.1 RBD probe are therefore not likely to provide the same clear-cut discrimination between Omicron-naïve and Omicron-exposed individuals due to the pre-existence of such cross-reactive B<sub>mem</sub>. Importantly, however, these pre-existing cross-reactive B<sub>mem</sub> also were capable of contributing to protective responses, as evidenced by reduced disease severity in cases of breakthrough Omicron infection. Therefore, while blurring the diagnostic specificity of comparisons between PBMC samples collected before or after emergence of SARS-CoV-2 variants of concern, the detection of cross-reactive B<sub>mem</sub>-derived ASC still provides valuable immune diagnostic information on the pre-existence of a primed, clonally expanded and IgG class-switched B<sub>mem</sub> repertoire reactive with the antigen being studied. What percentages of such preexisting, cross-reactive B<sub>mem</sub> are recruited into such a (secondary) B cell response, including to what extent they undergo further somatic mutation and affinity maturation, and clonal expansions, remains an open question.</p> <p>Additionally, to what extent increases of B<sub>mem</sub> frequencies reveal renewed antigen exposures is also an open question. In our preliminary studies on this issue, we found evidence for clonal expansions after each COVID-19 mRNA vaccination. In paired PBMC samples collected prior to and 14 days following the first COVID-19 mRNA vaccination, frequencies of S-antigen-reactive B<sub>mem</sub>-derived IgG<sup>+</sup> ASC went from undetectably low to an average of 20 IgG<sup>+</sup> ASC per 10<sup>6</sup> PBMC (Supplemental Fig. 8A). In a separate cohort, paired PBMC collected ~ 1 month following the second and third COVID-19 mRNA vaccinations also evidenced an increase in the frequency of S-antigen-reactive B<sub>mem</sub>-derived IgG<sup>+</sup> ASC following each COVID-19 mRNA vaccination. Following the second COVID-19 mRNA vaccination the average frequency of S-antigen-reactive B<sub>mem</sub>-derived IgG<sup>+</sup> ASC was ~ 527 IgG<sup>+</sup> ASC per 10<sup>6</sup> PBMC and it increased to ~ 3822 IgG<sup>+</sup> ASC per 10<sup>6</sup> PBMC following the third dose (~ 7.5-fold increase). Detailed assessment of PBMC samples collected following additional COVID-19 mRNA vaccinations and/or breakthrough infection with SARS-CoV-2 variants is ongoing in our group and seeks to define whether S-antigen-reactive B<sub>mem</sub>-derived ASC frequencies plateau after repeated antigen encounters. Therefore, increases in B<sub>mem</sub>-derived ASC frequencies may no longer be a reliable marker for diagnosing new antigen encounters once the memory B cell repertoire has been established.</p> <p>When frequency increases do not reveal antigen exposures, what other measures could be applied to better understand whether a new wave of B cell responses has been initiated, and whether this may have medical implications? For example, this is highly relevant to the important question of whether there is a benefit from repeated booster vaccinations, or is this merely a misinterpretation of Burnett’s clonal selection theory? While the answer to this question is still unknown, we can make some predictions, as follows.</p> <p>We must keep in mind that not all antigen-specific B<sub>mem</sub> are equal, even if they produce the same IgG class/subclass. Specifically, for example, owing to differences in the affinity of secreted antibody, a one million times higher concentration of low affinity (K<sub>D</sub>= 10<sup>− 5</sup>) antibody would be required to achieve the same degree of antigen binding as a high affinity (K<sub>D</sub>=10<sup>− 11</sup>) antibody (Note 23 & 24). Moreover, it is known that affinity maturation is reengaged with each repeated antigen encounter [<span citationid="CR44" class="CitationRef">44</span>]. Therefore, studying changes within the affinity distribution of the antigen-specific B<sub>mem</sub> repertoire (that also can readily be measured by B cell ImmunoSpot [<span citationid="CR24" class="CitationRef">24</span>]) might shed light on the beneficial effects of booster vaccinations when mere frequency increases do not provide conclusive information.</p> <p>Studying the appearance of spontaneously Ig-secreting antigen-specific plasmablasts, which appear in the blood shortly after the (re-)engagement of an immune response, may also hold great immunodiagnostic potential when simply measuring frequency increases of antigen-specific B<sub>mem</sub> no longer provides adequate resolution for detecting the induction of an immune response. Shortly following an antigen encounter, e.g. after SARS-CoV-2 mRNA vaccination, descendants of antigen-specific B cells that were engaged in the immune response appear in the blood (Supplemental Fig. 3C and D). Representing an alternative B cell fate than B<sub>mem</sub>, such plasmablasts are in the process of migrating via the bloodstream to immunological niches, such as the bone marrow, where they may take up residence and become long-lived plasma cells that contribute to maintaining antibody titers long-term. Similar to B<sub>mem</sub>, plasmablasts can also be cryopreserved while retaining their full functional activity [<span citationid="CR43" class="CitationRef">43</span>]. Importantly, plasmablasts in blood can be detected using the same direct B cell ImmunoSpot approach as described here for B<sub>mem</sub>-derived ASC, but without the need for prior <em>in vitro</em> polyclonal stimulation, by simply plating the PBMC as isolated (or after the thawing of a cryopreserved sample).</p> <p>A fascinating, but still completely underdeveloped field is the study of the B<sub>mem</sub> specific for autoantigens (including tumor-associated antigens). The following fundamental questions will need to be answered before the field of B (or T) cell immune diagnostics can progress with autoimmune diseases or cancers. In healthy individuals, and if so, to what extent, does the presence of the autoantigen (and which of the diverse autoantigens present on the target cells of interest) result in the spontaneous priming of autoantigen-specific B<sub>mem</sub>, and lead to their activation, deletion or induction of unresponsiveness? What is the situation with those tumor-associated antigens that are in fact overexpressed autoantigens? As autoantibodies specific for such autoantigens can be frequently detected in healthy individuals [<span citationid="CR46" class="CitationRef">46</span>], it might not come as a surprise if B<sub>mem</sub> will also be detected. How does this autoantigen-specific B<sub>mem</sub> repertoire change during an exacerbation of the autoimmune response in an autoimmune disease and/or cancer? Will studies of the resting B<sub>mem</sub> repertoire, or that of plasmablasts provide more insights into the underlying autoimmune responses? Owing to their exquisite sensitivity, if properly developed and validated, B cell ImmunoSpot assays are presently best positioned to provide answers to these fundamental questions. In these settings, however, a simple comparison of autoantigen/tumor associated antigen-reactive B<sub>mem</sub> frequencies between a “healthy” cohort vs. patients with the “autoimmune disease/cancer” may not always provide the expected diagnostic specificity information (primarily, if B<sub>mem</sub> are present in healthy donors), even if the antigen-specificity of the B cell ImmunoSpot test system is exquisite.</p> </div> <div id="Sec19" class="Section3"> <h2>3.1.4. Traditional definition of specificity in terms used by regulatory bodies</h2> <p>In bioanalysis, specificity refers to the ability to detect an analyte in the presence of potentially interfering substances. In the context of B cell ImmunoSpot assays, this interpretation of specificity translates into assessing whether the reliable detection of individual antigen-specific ASC in PBMC is compromised by other components present in the test sample. This could be due to absorption of antibodies by bystander cells, for example, or through restricted access to the antigen-coated membrane and lack of secretory footprint formation when large numbers of cells are plated in the assay well.</p> <p>To test the hypothesis that such interference might occur, we evaluated PBMC containing S-antigen-specific, B<sub>mem</sub>-derived IgG<sup>+</sup> ASC following polyclonal stimulation with or without the addition of autologous non-stimulated PBMC from the same blood draw (while the latter contain S-antigen-specific B<sub>mem</sub>, these cells are not actively secreting antibody). The results are shown in Supplemental Table 2, revealing negligible interference following addition of high numbers (5 x 10<sup>5</sup>) of resting autologous PBMC.</p> <p>As resting PBMC (that do not contain spontaneous ASC) were used in the above experiment, we also tested whether the addition of polyclonally activated PBMC (that contained an abundance of ASC but which lack specificity for the S-antigen) would interfere with the test results. To be able to do so, we needed to select donors for whom we had pre-COVID era PBMC cryopreserved (as the latter do not contain S-antigen-specific ASC); the addition of such autologous polyclonally stimulated pre-COVID PBMC to PBMC collected following COVID-19 mRNA vaccination resulted in an increased number of pan IgG<sup>+</sup> ASC. However, the number of S-antigen-specific B<sub>mem</sub>-derived IgG<sup>+</sup> ASC measured in the assay was not altered (Notes 45–47). The results shown in Supplemental Fig. 16 suggest that increasing the number of third-party antigen-specific ASC in the test sample does not interfere with the detection of antigen-specific ASC.</p> </div> </div> <div id="Sec20" class="Section2"> <h2>3.2. Accuracy</h2> <p>Accuracy is defined as closeness of agreement to a verifiably true value. For antigen-specific ImmunoSpot assays the true value that the assay aims to reveal is the number/frequency of antigen-specific, functional B or T cells in a test sample (Note 48). However, ImmunoSpot assay accuracy cannot be determined due to the lack of a reference standard or an alternative test that could provide an exact measurement of functional antigen-specific B or T cells in a given sample (except highly developed ImmunoSpot measurements, themselves). However, evaluating B cell hybridomas in such B cell ImmunoSpot tests, as shown in Supplemental Fig. 4, comes close to this requirement. For validated T cell ImmunoSpot assays, therefore, the emphasis has shifted towards obtaining data on the accuracy of a laboratory’s performance by participation in proficiency panels that yield information on a laboratory’s performance relative to the other laboratories testing the same reference samples (Note 49). For B cell ImmunoSpot assays, such proficiency panels do not exist yet.</p> <p>While the proficiency panel approach is certainly a work-around to the intended accuracy mandate, it is, for obvious reasons, a rather questionable one. As such proficiency panels neither require, nor encourage, the participating laboratories to harmonize through adopting standardized (best performing) protocols, reagents, or instruments, the participants, randomly utilizing a wide variety of such approaches, are likely to underperform on average. At the same time, the average itself sets the acceptance criterion for passing the accuracy assessment, which can even cause the better performing laboratories to fail (Note 50). The authors of the present communication strongly believe that expert laboratories, i.e. those that have committed extensive effort to developing in-depth expertise refining such assays, should set the standard for the performance of participating laboratories providing pre-characterized reference PBMC so other laboratories can verify their proficiency by reproducing the pre-established test results.</p> </div> <div id="Sec21" class="Section2"> <h2>3.3. Precision</h2> <p>Precision in validation is defined as determining the variability of the assay results. Precision testing has to evaluate intra-assay and inter-assay, including inter-operator, and day-to-day, variability.</p> <div id="Sec22" class="Section3"> <h2>3.3.1 Intra-assay precision</h2> <p>Intra-assay precision in regulatory language is also called “repeatability”. In T cell ImmunoSpot assays, it is measured by testing three replicates of the same PBMC sample in the same plate, whereby the PBMC samples from different donors are plated at a fixed “ideal” cell number per well that best measures a range of antigen-specific T cell frequencies (Note 51) [[<span citationid="CR4" class="CitationRef">4</span>]. This approach is valid for B cell ImmunoSpot assays only if the PBMC are seeded in numbers such that the frequencies of antigen-specific SFU are < 100 per well (or pan Ig SFU are < 300 per well), that is, before spot crowding and ELISA effects interfere with accurate SFU counting (see above, and Supplemental Figs. 4 and 10). Owing to the highly variable frequency of antigen-specific B cells in different individuals’ PBMC, there are two solutions for establishing intra-assay precision. If the numbers of antigen-specific ASC are still unknown for the samples, testing PBMC at serial dilutions with 3–4 replicate wells for each dilution step (starting e.g. at 3 x 10<sup>5</sup> PBMC per well, and progressing in a 1 + 1 dilution series) may suffice. In this case, the replicate wells containing < 100 SFU and > 20 SFU should be compared. Wells within this SFU count range provide the most accurate information on intra-assay precision, whereas lower spot counts exhibit increased variation due to the onset of Poisson noise (Supplemental Figs. 11 & 12). Results for such a S-antigen-specific ImmunoSpot test are shown in Supplemental Table 3.</p> <p>If the frequencies of antigen-specific ASC have already been pre-established for the PBMC samples, the cells can be seeded in replicates at a single cell concentration, in numbers that are expected to produce ~ 50–75 ASC per well. Fewer PBMC are needed for this second variant of intra-assay precision testing.</p> </div> <div id="Sec23" class="Section3"> <h2>3.3.2. Inter-assay precision</h2> <p>Inter-assay precision is also designated “intermediate precision”, or “plate-to-plate variability” in regulatory language. For T cell ImmunoSpot validation, it is typically established by testing two (or cells permitting, more) plates in parallel [<span citationid="CR4" class="CitationRef">4</span>], and this approach can also be adopted for B cell ImmunoSpot validation. However, as outlined above for assessing intra-assay variation, for the same reasons, PBMC have to be plated in serial dilution, and only the SFU counts in the upper linear range should be accepted.</p> <p>For establishing inter-assay precision, one approach is to seed pre-characterized PBMC in replicate wells at the fixed cell number that is expected to result in ~ 50–75 SFU per well. In this case, the coefficient of variation (CV) can be calculated for the corresponding wells. As a second option, frequency extrapolations for serially diluted PBMC for the two (or more) plates may be compared (Note 52). Results for the latter type of plate-to-plate variability testing are shown in Supplemental Table 4. For a suggestion on how to combine establishing the inter assay-precision with testing for day-to-day variability and specificity, see Note 42, and below.</p> <p>Because in the proposed inter-assay design the cells are tested in replicate wells in serial dilution, the results obtained will also permit the verification of the frequency calculations established from the means of the replicates vs. those obtained from individual wells (see Supplemental Fig. 15).</p> </div> <div id="Sec24" class="Section3"> <h2>3.3.3. Inter-investigator precision</h2> <p>Inter-investigator precision is one criterion to establish Reproducibility. It requires that the same cell samples are tested by three different investigators in parallel (Note 53). PBMC are plated at serial dilutions and frequencies are established from the linear range of the results. Supplemental Table 5 shows inter-investigator precision data for S antigen-specific B<sub>mem</sub>-derived IgG<sup>+</sup> ASC measurements. For a suggestion on how to consolidate establishing the inter-investigator precision testing with testing for day-to-day variability and specificity, see Note 42, and below.</p> </div> <div id="Sec25" class="Section3"> <h2>3.3.4. Day-to-day variability</h2> <p>Day-to-day (also called inter-assay) variability testing includes establishing the reproducibility of results obtained when the test is done on at least 3 different days by the same investigator(s). Without having to perform a separate series of tests involving extra cells, these data will be obtained as part of the 3 assay runs proposed in Note 42 for a streamlined validation effort, the only requirement being that at least one of the investigators tests the same PBMC samples (at least 3 of them) during the three occasions. Frequency extrapolations for each of the PBMC should be compared for the three independent tests.</p> <p>Of note, the day-to-day variability in such a B cell ImmunoSpot assay is expected to be substantially higher than for all the other variability tests due to the inclusion of additional variables before the actual assay is performed. These include possible variability among individual aliquots of cryopreserved PBMC, any day-to-day differences in the thawing and washing process, the subsequent cell counting for polyclonal B cell stimulation cultures, the culture conditions themselves, and the ensuing washing steps and counting of the polyclonally stimulated cells for adjusting their concentration prior to plating -- all these variables and more can contribute to the degree of day-to-day reproducibility of the result. Despite all these possible sources of variability, and despite the fact that these tests have been performed in an R&D setting, in our hands, antigen-specific B cell ImmunoSpot assays yield data within < 20% CV (Supplemental Table 6). In the example shown here, the frequency of S-antigen-specific B<sub>mem</sub>-derived IgG<sup>+</sup> ASC was established as the percentage of pan IgG<sup>+</sup> ASC present in each sample. With maximally 23% CV, the day-to-day variability was much lower than the 50% acceptability for cellular assays [<span citationid="CR4" class="CitationRef">4</span>].</p> </div> </div></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">4.0. Detection Limits</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><div id="Sec27" class="Section2"> <h2>4.1. Limit of blank</h2> <p>In analogy to T cell ImmunoSpot tests [<span citationid="CR4" class="CitationRef">4</span>], and also applicable for B cell ImmunoSpot assays, the limit of blank (LOB) is determined by evaluating wells that are treated identically to actual test wells but which were not seeded with PBMC (i.e., the membrane is coated with the antigen, but instead of PBMC, culture medium is added for the same culture period, then the Ig class-detecting antibodies are added, and visualized with the corresponding detection reagents (see Supplemental Fig. 1). Two wells per PBMC sample are reserved in the serial dilution series for the LOB (Supplemental Fig. 5A). As typically a multitude of PBMC samples are tested in B cell ImmunoSpot assays, the number of LOB wells will add up to a significant number. By definition, the LOB must be zero. If it is not, aggregated reagents are likely the cause of background noise. This can be remedied by filtering the reagents, or better, by subjecting the detection reagents to high-speed centrifugation (Note 54). Also, the recommended back-to-front final washing step helps to eliminate non-specific retention of reagents on the membrane (Note 55).</p> </div> <div id="Sec28" class="Section2"> <h2>4.2. Lower limit of detection</h2> <p>In T cell ImmunoSpot assays, the lower limit of detection (LOD) is generally set at 1.6 (conservatively 2–3)-fold the median SFU count for the background wells for each PBMC sample tested in replicate (in that case, the number of cytokine-producing cells present in the well detected if PBMC are plated in the absence of antigen). In the case of T cell assays, such a definition is appropriate because cells of the innate immune system can also secrete the measured cytokine and generate background “noise” above which the antigen-induced cytokine production by antigen-specific T cells needs to be detected as the specific signal. This definition cannot be applied to B cell ImmunoSpot assays, however, because only B cells produce antibody. While B cell ImmunoSpot assays can detect a single SFU in a cell input of up to 1 x 10<sup>6</sup>, this only indicates a secretory footprint was generated. Without putting an equal number of cells in an alternatively coated well for comparison, this one single spot is evidence of "reactivity" but is not necessarily "specific" for the coated antigen of interest. B cell assays – in theory at least -- need to account for "chance" recognition of elements coated on the plate (antigen itself, but also potentially the anti-affinity tag capture reagent, an affinity tag if present on the antigen of interest, any components of the assay medium that could absorb to the assay membrane, and any antigens (secreted IgG included) present in the PBMC that could absorb to the membrane during the assay incubation). When frequencies of antigen-specific ASC are relatively high, such negative controls will be less necessary (and the LOB serves its function). However, when studying very rare events using high cell inputs (> 5 x 10<sup>5</sup> PBMC per well) specificity controls are needed to dissect antigen-specific SFU from such background "noise" (which is typically donor intrinsic). In our experience gained so far, such “background noise” was either entirely absent in most samples, or, when present, was often < 2 SFU per 2 x 10<sup>5</sup> PBMC. Therefore, while further lowering the LOD is one area of ongoing investigation in our group, we presently believe, without extensive additional controls being involved, it is safe to set the LOD of standard B cell ImmunoSpot assays at 10 per 10<sup>6</sup> PBMC.</p> </div> <div id="Sec29" class="Section2"> <h2>4.3 Upper detection limit</h2> <p>When performed using a serial dilution approach, antigen-specific B cell ImmunoSpot assays do not have an inherent upper detection limit: if SFU counts exceed the linear range even at the lowest cell dilutions, re-testing the sample starting with a lower cell input and/or performing larger serial dilutions (e.g. 3-5-fold) will increase the upper detection limit. This can be as high as detecting a single secretory footprint when B cell hybridomas are tested (data not shown). Thus, the upper detection limit of a B cell ImmunoSpot assay is merely a function of the cell numbers plated.</p> </div></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">5.0 Quantification limit</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><div id="Sec31" class="Section2"> <h2>5.1 Lowest limit of quantification</h2> <p>The lowest limit of quantification (LLOQ) is the lowest concentration/frequency of antigen-specific ASC within PBMC that can be defined with the minimal required level of accuracy and precision (usually 10% or 20%). For T cell ImmunoSpot assays the term LLOQ is rarely used due to the mathematical considerations of a high %CV at low spot numbers per well [<span citationid="CR4" class="CitationRef">4</span>], and because the background noise and T cell/APC contacts required for T cell activation to occur prevent Poisson’s rule from applying for the precise evaluation of rare events.</p> <p>For B cell ImmunoSpot measurements, the LLOQ depends on the actual test variant performed. If lowering the LLOQ is desired, plating the cells in multiple replicate wells at high cell numbers per well is the assay approach of choice (see Section <span refid="Sec9" class="InternalRef">2.4.2</span> above). When frequencies are measured in screening tests by serial dilution, the initial cell input and obtaining a SFU count > 5 at the third dilution point will set the LLOQ. In the type of single well serial dilution tests we show here, when starting at 3 x 10<sup>5</sup> PBMC, the LLOQ is 67 SFU per 10<sup>6</sup>. Due to the onset of Poisson noise that occurs with low frequency SFU counts, increasing the number of replicate wells in such tests will further improve the LLOQ (Supplemental Fig. 12).</p> </div> <div id="Sec32" class="Section2"> <h2>5.2. Upper limit of quantification</h2> <p>For T cell assays, the upper limit of quantification (ULOQ) has been defined as the maximum number of individual spots per well the plate reader software can discriminate. Typically, this is achieved by counting spots from PBMC samples treated with a mitogen (or peptide for a donor with a very strong peptide response) and by analyzing the linearity of SFU counts per well and cell numbers plated per well. Applying this approach for S-antigen-specific B cell ImmunoSpot analysis, the ULOQ would be reached at ~ 100 SFU per well for antigen-specific assays (see Supplemental Fig. 10). It should be noted, however, that owing to the smaller and tighter spot morphologies observed in pan Ig assays, the ULOQ is ~ 300 SFU per well. Of note, the ULOQ is also affected by the software’s ability to distinguish individual SFU over elevated background membrane staining caused by the “ELISA effect” (in which antibody captured distally from the source ASC inevitably accumulates in wells as the number of antigen-specific ASC per well increases, as noted above).</p> <p>Because antigen-specific B cell ImmunoSpot testing should always rely on PBMC tested by serial dilution to accommodate the wide range of antigen-specific B<sub>mem</sub> frequencies (Supplemental Fig. 9), the above definition of ULOQ is not sufficient. Performing the assay with serially diluted samples, this definition of ULOQ applies only for establishing the linear range between cell numbers plated and SFU counts obtained, from which the actual frequencies are calculated by extrapolation. That number will define the ULOQ of the assay performed. For B cell ImmunoSpot tests performed with serial dilutions, the ULOQ is merely a function of the cell numbers plated; by their very nature, such B cell assays’ inherent ULOQ is 100% of all cells tested.</p> </div> <div id="Sec33" class="Section2"> <h2>5.3. Linearity</h2> <p>Linearity for B cell ImmunoSpot assays requires that the numbers of PBMC plated, and the number of SFU counted per well follows a linear function. Such linearity is inherent for detection of individual ASC in solution but will only be observed in a rather narrow range in B cell ImmunoSpot tests between 100 SFU for the antigen-specific test at the high end, and around 10 SFU per well on the low end (under which the Poisson noise comes into play, and only measurements done in increasing numbers of replicate wells can reveal the precise frequency. B cell ImmunoSpot assays with serial dilutions will reveal this linear range for each PBMC sample, from which SFU frequencies are to be calculated with the R<sup>2</sup> value revealing the precision for the goodness of fit. By the very nature of the test, any significant deviation from linearity in the 10 to < 100 SFU per well range can only result (a) from imprecise pipetting while performing the cell dilution series, (b) from damaging the cells through applying vigorous sheer forces while making the dilution series and pipetting, and/or (c), by damaging the membrane during cell transfers (see Note 38), or by counting parameters set incorrectly on the reader (both of the latter being verifiable by visual inspection of the deviant wells in QC mode). While in the 10 to < 100 SFU per well range, measurements of single well serial dilutions will enable accurate frequency calculations based on linearity fits (Supplemental Fig. 15), at < 20 SFU counts the Poisson noise increasingly affects the precision of linearity/frequency calculations. Increasing the number of replicate wells can increase the precision of linearity in this low count range.</p> </div></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">6.0. Precision across different types of assays</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><p>Our analysis of SARS-CoV-2 S-antigen-specific B<sub>mem</sub> reactivity so far, whether assessed in vaccinated individuals, in unvaccinated infected people, or in those both vaccinated and infected, showed that only IgG and IgA class-determinations provided readily interpretable results (Supplemental Fig. 8, and work in progress). In polyclonally-stimulated PBMC, IgM<sup>+</sup> S-antigen-reactive SFU were detectable in naïve, pre-pandemic PBMC samples at frequencies similar to verifiably exposed individuals (Supplemental Fig. 8B), a finding we attribute to the presence of low affinity, broadly cross-reactive naïve B cells. Therefore, S-antigen-reactive IgM<sup>+</sup> ASC in polyclonally stimulated PBMC lack diagnostic specificity. In contrast, S-antigen-specific IgM<sup>+</sup> ASC can be detected in PBMC collected acutely following initiation of a COVID-19 mRNA-elicited immune response, identifying <em>in vivo</em>-induced not (yet) class-switched B cells (Note 56) [<span citationid="CR47" class="CitationRef">47</span>]. Although our four-color multiplexed assay has been optimized for detecting IgE<sup>+</sup> ASC [<span citationid="CR40" class="CitationRef">40</span>, <span citationid="CR48" class="CitationRef">48</span>], thus far we have not detected any IgE<sup>+</sup> ASC following polyclonal (TLR7/8 + rIL-2, B-Poly-S) stimulation of PBMC isolated from healthy (non-allergic) individuals (Supplemental Fig. 5B and Note 38). Therefore, one might argue that a two-color IgA/IgG ELISPOT or FluoroSpot assay would suffice for monitoring the S-antigen-specific B<sub>mem</sub> compartment.</p> <p>For pan Ig detection, we have established that single-color enzymatic, and single- or multicolor fluorescent B cell ImmunoSpot assays yield nearly identical SFU counts (Supplemental Fig. 14, and [<span citationid="CR40" class="CitationRef">40</span>]). However, such polyclonal assays fundamentally differ from antigen-specific B cell ImmunoSpot detection. In the former, the ASC-derived Ig is captured by high affinity antibodies, irrespective of the ASC-derived antibody affinity for the antigen, i.e., only the amount of Ig secreted (productivity) per ASC will define the quantity of ASC-derived Ig retained on the membrane (see Supplemental Fig. 1C). For antigen-specific assays, in contrast, the antibodies’ affinity for the antigen will decisively define their binding to the coated membrane (see Supplemental Fig. 1A & B). It could be expected that, due to enzymatic amplification, ELISPOT assays will be more sensitive in detecting “faint” secretory footprints originating from low affinity ASC than when these are detected via immunofluorescence, without amplification. Without carrying out a full validation effort, we performed preliminary assays to test the precision across these assays. Cryopreserved PBMC from an individual known to possess B<sub>mem</sub>-derived ASC secreting either IgG or IgA (at different frequencies) following <em>in vitro</em> polyclonal stimulation were re-tested in S-antigen-specific assays for secretory footprints detected in two-color enzymatic (DCE), two-color fluorescent (DCF) assays detecting IgA<sup>+</sup> and IgG<sup>+</sup> ASC, or in a four-color MAGE assay. The results are shown in Supplemental Fig. 17, revealing no major differences in SFU counts.</p></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">7.0 Pre-analytical considerations</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><p>Pre-analytical considerations refer to the (many) variables that can be present between blood collection and the actual analysis of the PBMC in the antigen-specific B cell ImmunoSpot assay. These are similar to those that can affect T cell ImmunoSpot test results, but, while they have been extensively studied for T cells, no such systematic studies exist to date on B cells. Here we also need to distinguish between circulating antigen-specific B cell plasmablasts, that are metabolically highly active cells, and resting B<sub>mem</sub>. Most of our experience has been gained studying the latter, and they are also the main focus of this paper. While working towards reliable and consistent detection of underlying B<sub>mem</sub>, thus far we have adhered to pre-analytical considerations established for detecting resting memory cells in T cell ImmunoSpot assays. Nonetheless, we have gained the overall impression that the lessons learned in the T cell field will also apply to the pre-analytical considerations for B<sub>mem</sub> testing.</p> <p>When the blood is drawn, it is important to avoid unnecessary sheer forces to prevent hemolysis or damage to the white blood cells (e.g. by using a 21G needle to avoid forceful aspiration) and using heparin as the anticoagulant. Until cryopreservation or testing, the cells should be kept in whole blood, rather than as separated PBMC, and at ambient temperature (25-35<sup>o</sup>C) in the dark (never chilled or kept on ice). Our preliminary results obtained so far showed that, stored (or shipped) in this way, B<sub>mem</sub> preserve their full functionality for at least 24 h (Yao, work in progress). Accordingly, overnight shipment of blood (at controlled ambient temperature) from clinical sites to central test facilities is not expected to interfere with the test results. For the isolation of PBMC from the blood, density gradient centrifugation over a medium with a density of 1.077g/mL (e.g. Lymphoprep™ or Ficoll-Paque™) is the method of choice for T cell assays, and also works well for B cells. In fact, B cell assays are likely to be less sensitive to the PBMC separation method, but this still needs to be confirmed. Cells should continue to be kept at ambient temperature during isolation, and for short-term storage of the PBMC after isolation until initiation of the testing, or cryopreservation.</p> <p>PBMC can be cryopreserved to maintain full T- [<span citationid="CR49" class="CitationRef">49</span>] and B memory cell activity [<span citationid="CR43" class="CitationRef">43</span>]. For T cell assays, freezing PBMC without serum has been essential to avoid the effects of suppressive effects or stimulatory effects caused by bioactive molecules present in serum. Serum-free freezing also works perfectly for B cells, and we have been routinely doing this. Any number of PBMC can be frozen at a cell density between 0.5–10 x 10<sup>6</sup> per cryovial, with B cell functionality fully retained following <em>in vitro</em> polyclonal stimulation (Becza, work in progress). This approach permits freezing multiple PBMC aliquots and facilitates careful study design (Note 42).</p> <p>Starting the freezing process by adding DMSO-containing cryopreservation medium that is warmed to the same ambient temperature as the cells is key to success (Note 57). For the actual cryopreservation, using a rate-controlled freezer is preferable, but in our hands has no detectable advantage over freezing in Mr. Frosty™ freezing containers, or even just using the “low tech” approach in which two suitable styrofoam racks are sandwiched together in a loose plastic bag wrap (containing plenty of air) prior to placing the cells in the − 80<sup>o</sup>C freezer short-term. Cryopreserved cells should be transferred to liquid nitrogen within 24 h; storing them longer in the − 80<sup>o</sup>C freezer should be avoided. Partial warming up of cryovials during storage should be avoided to prevent “glass phase” transitions from occurring, which can damage cryopreserved cells [<span citationid="CR50" class="CitationRef">50</span>]. Even before thawing, cryovials should not be kept in the − 80<sup>o</sup>C freezer for longer than 24 h [<span citationid="CR51" class="CitationRef">51</span>].</p> <p>For thawing the PBMC, follow the protocol described in [<span citationid="CR52" class="CitationRef">52</span>]. Here too, bringing the contents of the cryovial up to 37<sup>o</sup>C by placing it in a water bath (or better for sterility, in a glass bead bath) before dilution of the DMSO is advisable. The cells can be maintained at 37<sup>o</sup>C, in 10% (v/v) DMSO-containing cryopreservation medium for > 30 min without appreciable differences in functionality. Therefore, many cryovials can be thawed simultaneously to facilitate high throughput testing. The addition of warm washing medium containing Benzonase (Note 58) is required for obtaining the best result (definitively better results than following the classical protocol that suggests thawing cryovials one by one until the last ice crystal is visible in the cryovial, followed by immediate washing with ice-cold medium [<span citationid="CR49" class="CitationRef">49</span>].</p> <p>For subsequent polyclonal B cell stimulation, fetal calf serum (FCS)-containing culture medium is required. The serum-free media that work so well for T cell assays, and are ideal for standardization of assay conditions for T cell ImmunoSpot [<span citationid="CR53" class="CitationRef">53</span>], do not contain the necessary growth factors required to support the transition of resting B<sub>mem</sub> into ASC during the 5 days of <em>in vitro</em> stimulation (Note 60 and 61). Unlike T cell assays, in which different FCS batches can have profound effects on assay performance [<span citationid="CR53" class="CitationRef">53</span>], in our preliminary assessments so far, we did not find FCS to be a critical assay variable (Supplemental Fig. 18), but this notion needs additional robust verification.</p> <p>A combination of the TLR7/8 ligand R848 and recombinant human interleukin 2 (rIL-2) is commonly used to achieve potent polyclonal B cell stimulation for downstream assessment in B cell ImmunoSpot tests [<span citationid="CR54" class="CitationRef">54</span>, <span citationid="CR55" class="CitationRef">55</span>]. It is also ideal for studies of Ig class and subclass expression by B<sub>mem</sub> <em>in vivo</em>, because it does not provide signals that promote Ig class switching during the <em>in vitro</em> stimulation culture period (Note 61). Owing to the potential variable that different batches of polyclonal stimulation reagent(s) may possess different potencies, we recommend to always include a positive control PBMC sample alongside the test sample(s) to verify the potency of the polyclonal stimulation culture by establishing in a pan Ig assay that the maximal numbers of Ig-producing ASC have indeed been induced (Note 63). Supplemental Fig. 2A-C shows that maximal IgM<sup>+</sup>, IgA<sup>+</sup> and IgG<sup>+</sup> ASC activity following R848 + rIL-2 (B-Poly-S) stimulation occurred after 5 days of <em>in vitro</em> stimulation for most donors tested. Of paramount importance for performing B cell ImmunoSpot tests following <em>in vitro</em> stimulation of the test samples is the need to thoroughly wash the cells to remove any “specific” Ig present in the culture supernatant before plating into the actual assay, as this can increase the background staining of the membrane and interfere with detection of antigen-specific ASC.</p></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">8.0. Concluding remarks</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><p>In Note 42 we have provided an experimental plan for how - using only 2.2 x 10<sup>7</sup> PBMC in total – to generate all data required for the validation of an antigen-specific B cell ImmunoSpot assay. The plate layout shown in Supplemental Fig. 5A permits the subsequent high throughput testing of clinical samples requiring only 1–2 x 10<sup>6</sup> PBMC per test subject to determine the frequency of antigen-specific B<sub>mem</sub>-derived ASC secreting all four classes of Ig. Detailed protocols (a link to Supplemental Materials and Methods can be found at the end of this paper, under “<span refid="Sec37" class="InternalRef">Appendix</span>”) and in-depth technical and theoretical comments provided above should help laboratories interested in B cell immune monitoring adopt this technique to develop and validate such assays for their antigens of interest.</p> <p>The above considerations apply for testing frequencies of resting, antigen-specific B<sub>mem</sub> cells. While dramatic frequency increases are seen following primary and secondary antigen challenge, frequency changes after additional antigen encounters may no longer be as notable after B cell memory has been established. In such cases, the elicitation of a plasmablast response (Note 44) or changes in the affinity of antigen-specific ASC may provide evidence for the re-activation of a B cell response. As indicated previously above, the detection of such antigen-specific plasmablasts follows the same approach as described for B<sub>mem</sub> except that the actual B cell ImmunoSpot testing is done with freshly isolated PBMC (or after such cells are cryopreserved and thawed), without the requirement for prior polyclonal stimulation (Note 64). For in-depth studies of affinity distributions within the antigen-specific B cell repertoire, an approach described in [<span citationid="CR25" class="CitationRef">25</span>] is best suited.</p> <p>In addition to assessing the frequency of antigen-specific B<sub>mem</sub>-derived ASC (or plasmablasts), four-color ImmunoSpot assays described here are also uniquely suited to studying additional Ig class (and IgG subclass) switching that can occur with repeated antigen encounters. Recently, for example, attention has been drawn to the change within the S-antigen-specific IgG response after repeated booster immunizations: an initially IgG1/IgG3 polarized B cell response switching to a mixed IgG1/IgG4 composition [<span citationid="CR56" class="CitationRef">56</span>], a finding we have also confirmed performing four-color S-antigen-specific IgG subclass analysis. Such shifts are of major clinical significance because IgG1 and IgG4 have antagonistic immuno-biological effects (Note 65). IgG subclass-detecting four-color assays follow the same protocols described above, except that the detection reagents used are IgG subclass-, instead of Ig class-specific.</p> <p>All of these recent developments in B cell immune monitoring abilities have opened a new window onto the thus far hidden universe of B<sub>mem</sub> responses by employing B cell ImmunoSpot® analysis, greatly supplementing what can be discerned by the present, limited, techniques deployed for immune monitoring of humoral immunity.</p></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">Declarations</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><h2>Declaration of Competing Interest</h2> <p>All authors are employees of CTL and may hold stock.</p> <h2>Funding</h2> <p>All funding for this work came from CTL’s R&D budget.</p><h2>Author Contributions</h2> <p> <em>Conceptualization</em>: PVL and GAK; <em>Data Curation</em>: AVG and GAK; <em>Formal Analysis</em>: AYK, NB, LLY, JC, CW, SK, AVG and GAK; <em>Investigation</em>: NB, LLY, ZL, JC, AMP, CW, SK, AV, AVG and GAK; <em>Methodology</em>: PVL, NB, ZL, GAK; <em>Project administration</em>: PVL, AVG and GAK; <em>Resources</em>: AYK, ZL, JC and GAK; <em>Software</em>: AYK, <em>Supervision</em>: PVL, MTL and GAK; <em>Visualization</em>: AYK, NB, LLY, JC and GAK; <em>Writing</em>: PVL and GAK; <em>Review & editing</em>: PVL, AYK, MTL and GAK</p><h2>Acknowledgements</h2> <p>The authors would like to thank Dr. Graham Pawelec for critical review and editing the manuscript.</p><h2>Data availability</h2> <p>Qualified researchers may request access to test subject-related data and related documents. Such data will be anonymized, and study documents will be redacted to protect the privacy of trial participants.</p></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">References</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><div class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><div><ol><li><span>Czerkinsky CC et al (1983) A solid-phase enzyme-linked immunospot (ELISPOT) assay for enumeration of specific antibody-secreting cells. J Immunol Methods 65(1–2):109–121</span></li> <li><span>Sedgwick JD, Holt PG (1983) A solid-phase immunoenzymatic technique for the enumeration of specific antibody-secreting cells. J Immunol Methods 57(1–3):301–309</span></li> <li><span>Czerkinsky C et al (1988) Reverse ELISPOT assay for clonal analysis of cytokine production. I. Enumeration of gamma-interferon-secreting cells. J Immunol Methods 110(1):29–36</span></li> <li><span>Korber N et al (2016) Validation of an IFNgamma/IL2 FluoroSpot assay for clinical trial monitoring. J Transl Med 14(1):175</span></li> <li><span>Lehmann PV (1995) Methods for measuring T-cell cytokines. United States</span></li> <li><span>Hesse MD et al (2001) A T cell clone's avidity is a function of its activation state. J Immunol 167(3):1353–1361</span></li> <li><span>Forsthuber T, Yip HC, Lehmann PV (1996) Induction of TH1 and TH2 immunity in neonatal mice. Science 271(5256):1728–1730</span></li> <li><span>Zhang W, Lehmann PV (2012) Objective, user-independent ELISPOT data analysis based on scientifically validated principles. Methods Mol Biol 792:155–171</span></li> <li><span>Slota M et al (2011) ELISpot for measuring human immune responses to vaccines. Expert Rev Vaccines 10(3):299–306</span></li> <li><span>Shafer-Weaver K et al (2006) Application of the granzyme B ELISPOT assay for monitoring cancer vaccine trials. J Immunother 29(3):328–335</span></li> <li><span>Pass HA et al (1998) Immunization of patients with melanoma peptide vaccines: immunologic assessment using the ELISPOT assay. Cancer J Sci Am 4(5):316–323</span></li> <li><span>Malyguine A et al (2007) New approaches for monitoring CTL activity in clinical trials. Adv Exp Med Biol 601:273–284</span></li> <li><span>Ranieri E, Popescu I, Gigante M (2014) CTL ELISPOT assay. Methods Mol Biol 1186:75–86</span></li> <li><span>Koppert S et al (2021) <em>Affinity Tag Coating Enables Reliable Detection of Antigen-Specific B Cells in Immunospot Assays</em>. Cells, 10(8)</span></li> <li><span>Terlutter F et al (2018) <em>Direct Detection of T- and B-Memory Lymphocytes by ImmunoSpot(R) Assays Reveals HCMV Exposure that Serum Antibodies Fail to Identify</em>. Cells, 7(5)</span></li> <li><span>Wolf C et al (2022) <em>Antibody Levels Poorly Reflect on the Frequency of Memory B Cells Generated following SARS-CoV-2, Seasonal Influenza, or EBV Infection</em>. Cells, 11(22)</span></li> <li><span>Kuerten S et al (2014) Identification of a B cell-dependent subpopulation of multiple sclerosis by measurements of brain-reactive B cells in the blood. Clin Immunol 152(1–2):20–24</span></li> <li><span>Robinson MJ et al (2023) Intrinsically determined turnover underlies broad heterogeneity in plasma-cell lifespan. Immunity 56(7):1596–1612e4</span></li> <li><span>Long QX et al (2020) Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections. Nat Med 26(8):1200–1204</span></li> <li><span>Gaebler C et al (2021) Evolution of antibody immunity to SARS-CoV-2. Nature 591(7851):639–644</span></li> <li><span>Seow J et al (2020) Longitudinal observation and decline of neutralizing antibody responses in the three months following SARS-CoV-2 infection in humans. Nat Microbiol 5(12):1598–1607</span></li> <li><span>Xiang T et al (2021) Declining Levels of Neutralizing Antibodies Against SARS-CoV-2 in Convalescent COVID-19 Patients One Year Post Symptom Onset. Front Immunol 12:708523</span></li> <li><span>Akkaya M, Kwak K, Pierce SK (2020) B cell memory: building two walls of protection against pathogens. Nat Rev Immunol 20(4):229–238</span></li> <li><span>P.V., L., et al., <em>Monitoring memory B cells by next generation ImmunoSpot® provides insights into humoral immunity that measurements of circulating antibodies do not reveal</em>. Methods Mol Biol, (2023)</span></li> <li><span>Becza N et al (2023) <em>Assessing the affinity spectrum of the antigen-specific B cell repertoire via ImmunoSpot®</em>. Methods Mol Biol</span></li> <li><span>Administration FaD (2018) <em>Bioanalytical method validation guidance for industry</em>. 04/29/2020 [cited 2024 February 1]</span></li> <li><span>Tary-Lehmann M, Hamm CD, Lehmann PV (2008) <em>Validating Reference Samples for Comparison in a Regulated ELISPOT Assay</em>, in <em>Validation of Cell-Based Assays in the GLP Setting</em>. p. 127–146</span></li> <li><span>Weiss AJ (2012) Overview of membranes and membrane plates used in research and diagnostic ELISPOT assays. Methods Mol Biol 792:243–256</span></li> <li><span>Bisceglia H et al (2023) A FluoroSpot B assay for the detection of IgA and IgG SARS-CoV-2 spike-specific memory B cells: Optimization and qualification for use in COVID-19 vaccine trials. J Immunol Methods 515:113457</span></li> <li><span>Karulin AY, Lehmann PV (2012) How ELISPOT morphology reflects on the productivity and kinetics of cells' secretory activity. Methods Mol Biol 792:125–143</span></li> <li><span>Wysocki L, Manser T, Gefter ML (1986) Somatic evolution of variable region structures during an immune response. Proc Natl Acad Sci U S A 83(6):1847–1851</span></li> <li><span>Wrammert J et al (2008) Rapid cloning of high-affinity human monoclonal antibodies against influenza virus. Nature 453(7195):667–671</span></li> <li><span>Padlan EA et al (1989) Structure of an antibody-antigen complex: crystal structure of the HyHEL-10 Fab-lysozyme complex. Proc Natl Acad Sci U S A 86(15):5938–5942</span></li> <li><span>Moulana A et al (2023) <em>The landscape of antibody binding affinity in SARS-CoV-2 Omicron BA.1 evolution</em>. Elife, 12</span></li> <li><span>Dzimianski JV et al (2023) Structural insights into the broad protection against H1 influenza viruses by a computationally optimized hemagglutinin vaccine. Commun Biol 6(1):454</span></li> <li><span>Di Niro R et al (2015) Salmonella Infection Drives Promiscuous B Cell Activation Followed by Extrafollicular Affinity Maturation. Immunity 43(1):120–131</span></li> <li><span>Dal Porto JM et al (2002) Very low affinity B cells form germinal centers, become memory B cells, and participate in secondary immune responses when higher affinity competition is reduced. J Exp Med 195(9):1215–1221</span></li> <li><span>Liao HX et al (2013) Co-evolution of a broadly neutralizing HIV-1 antibody and founder virus. Nature 496(7446):469–476</span></li> <li><span>Wang TT et al (2017) IgG antibodies to dengue enhanced for FcgammaRIIIA binding determine disease severity. Science 355(6323):395–398</span></li> <li><span>Yao L et al (2023) Four-color ImmunoSpot® assays requiring only 1–3 mL of blood permit precise frequency measurements of antigen-specific B cells secreting immunoglobulins of all four classes and subclasses. Methods. Mol. Biol</span></li> <li><span>Stavnezer J, Guikema JE, Schrader CE (2008) Mechanism and regulation of class switch recombination. Annu Rev Immunol 26:261–292</span></li> <li><span>Karulin AY et al (2018) Multiplexing T- and B-Cell FLUOROSPOT Assays: Experimental Validation of the Multi-Color ImmunoSpot((R)) Software Based on Center of Mass Distance Algorithm. Methods Mol Biol 1808:95–113</span></li> <li><span>Fecher P et al (2018) <em>B Cells and B Cell Blasts Withstand Cryopreservation While Retaining Their Functionality for Producing Antibody</em>. Cells, 7(6)</span></li> <li><span>Victora GD, Nussenzweig MC (2022) Germinal Centers Annu Rev Immunol 40:413–442</span></li> <li><span>Nickbakhsh S et al (2020) Epidemiology of Seasonal Coronaviruses: Establishing the Context for the Emergence of Coronavirus Disease 2019. J Infect Dis 222(1):17–25</span></li> <li><span>Nagele EP et al (2013) Natural IgG autoantibodies are abundant and ubiquitous in human sera, and their number is influenced by age, gender, and disease. PLoS ONE 8(4):e60726</span></li> <li><span>Pape KA et al (2021) High-affinity memory B cells induced by SARS-CoV-2 infection produce more plasmablasts and atypical memory B cells than those primed by mRNA vaccines. Cell Rep 37(2):109823</span></li> <li><span>Franke F et al (2020) <em>IL-21 in Conjunction with Anti-CD40 and IL-4 Constitutes a Potent Polyclonal B Cell Stimulator for Monitoring Antigen-Specific Memory B Cells</em>. Cells, 9(2)</span></li> <li><span>Kreher CR et al (2003) CD4 + and CD8 + cells in cryopreserved human PBMC maintain full functionality in cytokine ELISPOT assays. J Immunol Methods 278(1–2):79–93</span></li> <li><span>Smith JG et al (2007) Establishing acceptance criteria for cell-mediated-immunity assays using frozen peripheral blood mononuclear cells stored under optimal and suboptimal conditions. Clin Vaccine Immunol 14(5):527–537</span></li> <li><span>Wunsch M et al (2015) Serial Measurements of Apoptotic Cell Numbers Provide Better Acceptance Criterion for PBMC Quality than a Single Measurement Prior to the T Cell Assay. Cells 4(1):40–55</span></li> <li><span>Ramachandran H et al (2012) Optimal thawing of cryopreserved peripheral blood mononuclear cells for use in high-throughput human immune monitoring studies. Cells 1(3):313–324</span></li> <li><span>Janetzki S et al (2010) Performance of serum-supplemented and serum-free media in IFNgamma Elispot Assays for human T cells. Cancer Immunol Immunother 59(4):609–618</span></li> <li><span>Jahnmatz M et al (2013) Optimization of a human IgG B-cell ELISpot assay for the analysis of vaccine-induced B-cell responses. J Immunol Methods 391(1–2):50–59</span></li> <li><span>Pinna D et al (2009) Clonal dissection of the human memory B-cell repertoire following infection and vaccination. Eur J Immunol 39(5):1260–1270</span></li> <li><span>Irrgang P et al (2023) Class switch toward noninflammatory, spike-specific IgG4 antibodies after repeated SARS-CoV-2 mRNA vaccination. Sci Immunol 8(79):eade2798</span></li> <li><span>Lehmann PV, Lehmann AA (2020) Aleatory epitope recognition prevails in human T cell responses? Crit Rev Immunol 40(3):225–235</span></li> <li><span>Karulin AY et al (2015) ELISPOTs produced by CD8 and CD4 cells follow log normal size distribution permitting objective counting. Cells 4(1):56–70</span></li> <li><span>Sundararaman S et al (2015) High reproducibility of ELISPOT counts from nine different laboratories. Cells 4(1):21–39</span></li> <li><span>Karulin AY et al (2023) <em>Artificial intelligence-based counting algorithm enables accurate and detailed analysis of the broad-spectrum of spot morphologies observed in antigen-specific B cell ELISPOT and FLUOROSPOT assays</em>. Methods Mol Biol</span></li> <li><span>Morell A, Terry WD, Waldmann TA (1970) Metabolic properties of IgG subclasses in man. J Clin Invest 49(4):673–680</span></li> <li><span>Blandino R, Baumgarth N (2019) Secreted IgM: New tricks for an old molecule. J Leukoc Biol 106(5):1021–1034</span></li> <li><span>van Tetering G et al (2020) <em>Fc Engineering strategies to advance IgA antibodies as therapeutic agents</em>. Antibodies (Basel), 9(4)</span></li> <li><span>Normansell R et al <em>Omalizumab for asthma in adults and children</em>. Cochrane Database Syst Rev, 2014(1): p. CD003559</span></li> <li><span>Ardeniz O et al (2015) beta2-Microglobulin deficiency causes a complex immunodeficiency of the innate and adaptive immune system. J Allergy Clin Immunol 136(2):392–401</span></li> <li><span>Stapleton NM et al (2011) Competition for FcRn-mediated transport gives rise to short half-life of human IgG3 and offers therapeutic potential. Nat Commun 2:599</span></li> <li><span>Bruhns P, Jonsson F (2015) Mouse and human FcR effector functions. Immunol Rev 268(1):25–51</span></li> <li><span>Lee CM, Oh JE (2022) Resident memory B cells in barrier tissues. Front Immunol 13:953088</span></li> <li><span>Chu RS et al (1997) CpG oligodeoxynucleotides act as adjuvants that switch on T helper 1 (Th1) immunity. J Exp Med 186(10):1623–1631</span></li> <li><span>Yip HC et al (1999) Adjuvant-guided type-1 and type-2 immunity: infectious/noninfectious dichotomy defines the class of response. J Immunol 162(7):3942–3949</span></li> <li><span>Webb NE, Bernshtein B, Alter G (2021) Tissues: the unexplored frontier of antibody mediated immunity. Curr Opin Virol 47:52–67</span></li> <li><span>Muir L et al (2017) Optimisation of ex vivo memory B cell expansion/differentiation for interrogation of rare peripheral memory B cell subset responses. Wellcome Open Res 2:97</span></li> <li><span>Mei HE et al (2009) Blood-borne human plasma cells in steady state are derived from mucosal immune responses. Blood 113(11):2461–2469</span></li> <li><span>Rispens T, Huijbers MG (2023) The unique properties of IgG4 and its roles in health and disease. Nat Rev Immunol 23(11):763–778</span></li> <li><span>Mueller SN, Ahmed R (2009) High antigen levels are the cause of T cell exhaustion during chronic viral infection. Proc Natl Acad Sci U S A 106(21):8623–8628</span></li> <li><span>Helms T et al (2000) Direct visualization of cytokine-producing recall antigen-specific CD4 memory T cells in healthy individuals and HIV patients. J Immunol 164(7):3723–3732</span></li> <li><span>Targoni OS, Lehmann PV (1998) Endogenous myelin basic protein inactivates the high avidity T cell repertoire. J Exp Med 187(12):2055–2063</span></li> <li><span>Taylor JJ et al (2012) Deletion and anergy of polyclonal B cells specific for ubiquitous membrane-bound self-antigen. J Exp Med 209(11):2065–2077</span></li> <li><span>Ross TM et al (2022) <em>Kinetic of the antibody response following AddaVax-adjuvanted immunization with recombinant influenza antigens</em>. Vaccines (Basel), 10(8)</span></li> <li><span>Czajkowsky DM, Shao Z (2009) The human IgM pentamer is a mushroom-shaped molecule with a flexural bias. Proc Natl Acad Sci U S A 106(35):14960–14965</span></li> <li><span>Diebolder CA et al (2014) Complement is activated by IgG hexamers assembled at the cell surface. Science 343(6176):1260–1263</span></li> <li><span>Reid KBM (2018) Complement component C1q: Historical perspective of a functionally versatile, and structurally unusual, serum protein. Front Immunol 9:764</span></li> <li><span>Hanson J et al (2015) ELISPOT assays in 384-well format: up to 30 data points with one million cells. Cells 4(1):71–83</span></li> <li><span>Dangi T et al (2023) Pre-existing immunity modulates responses to mRNA boosters. Cell Rep 42(3):112167</span></li> <li><span>Nunez IA et al (2017) Impact of age and pre-existing influenza immune responses in humans receiving split inactivated influenza vaccine on the induction of the breadth of antibodies to influenza A strains. PLoS ONE 12(11):e0185666</span></li> <li><span>Lu LL et al (2018) Beyond binding: antibody effector functions in infectious diseases. Nat Rev Immunol 18(1):46–61</span></li> <li><span>Moodie Z et al (2006) Statistical positivity criteria for the analysis of ELISpot assay data in HIV-1 vaccine trials. J Immunol Methods 315(1–2):121–132</span></li> <li><span>Moodie Z et al (2010) Response definition criteria for ELISPOT assays revisited. Cancer Immunol Immunother 59(10):1489–1501</span></li> <li><span>Sautto GA et al (2020) A computationally optimized broadly reactive antigen subtype-specific influenza vaccine strategy elicits unique potent broadly neutralizing antibodies against hemagglutinin. J Immunol 204(2):375–385</span></li> <li><span>Carlock MA et al (2019) Impact of age and pre-existing immunity on the induction of human antibody responses against influenza B viruses. Hum Vaccin Immunother 15(9):2030–2043</span></li> <li><span>Ecker JW et al (2020) <em>High-yield expression and purification of recombinant influenza virus proteins from stably-transfected mammalian cell lines</em>. Vaccines (Basel), 8(3)</span></li></ol></div></span></div></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">Additional Declarations</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><p class="tw-text-base tw-antialiased tw-leading-relaxed tw-text-left tw-text-black md:tw-leading-loose _fulltext-content"><span style="display:block"><p>The authors declare potential competing interests as follows: All authors are employees of CTL and may hold stock.</p></span></p></div></div><div class="tw-border-b-2 tw-border-gray-100 tw-px-4"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><button type="button" class="focus:tw-outline-none tw-group tw-min-w-full"><div class="tw-flex tw-items-start tw-justify-between"><div class="tw-py-2 tw-w-full"><h2 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-xl">Supplementary Files</h2></div><div class="tw-py-2 sm:tw-border-r-2 sm:tw-border-white"><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-ml-4 tw-h-7 tw-w-7 tw-flex-shrink-0 tw-rounded-full tw-text-gray-500 group-hover:tw-bg-gray-200 group-hover:tw-text-gray-900 tw-transform tw-duration-300 -tw-rotate-180"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-pb-1"><ul class="tw-pl-6 tw-list-disc tw-list-outside"><li class="tw-pb-2 tw-break-words"><a href="https://assets-eu.researchsquare.com/files/rs-3994852/v1/69beb5e2c44fd7825dd86117.docx" class="tw-text-blue-600 hover:tw-text-blue-800 hover:tw-underline">Appendix.docx</a></li></ul></div></div></div></div></div><div class="tw-col-span-4 lg:tw-min-h-screen xl:tw-px-0"><div class="tw-bg-gray-50 md:tw-px-1.5 tw-max-w-reading tw-mx-auto lg:tw-bg-white lg:tw-sticky lg:tw-top-0 lg:tw-flex-1 lg:tw-h-screen lg:tw-overflow-y-scroll lg:tw-overflow-visible lg:tw-mx-0 lg:tw-px-0 lg:tw-max-w-none _rs-scrollbar"><div class="tw-flex tw-w-full lg:tw-justify-end"><div class="tw-pt-6 tw-pb-24 tw-w-full sm:tw-max-w-xl lg:tw-px-4 xl:tw-px-8"><div class="tw-hidden lg:tw-flex tw-pl-3 tw-justify-end"><div class="tw-pr-3"><div class="tw-relative tw-inline-block tw-text-left"><div><button class="tw-group tw-inline-flex tw-items-center tw-px-3 tw-py-2 tw-transition-all tw-border-2 tw-rounded-md tw-group tw-bg-white tw-border-gray-100 hover:tw-bg-gray-100 focus:tw-outline-none" id="headlessui-menu-button-:R56l6:" type="button" aria-haspopup="true" aria-expanded="false"><svg xmlns="http://www.w3.org/2000/svg" class="tw-w-5 tw-h-5 tw-text-gray-600" fill="none" viewBox="0 0 24 24" stroke="currentColor"><path d="M16.6187 6.07577C17.6476 6.07404 18.4714 6.44992 19.09 7.20342C19.6858 7.97982 19.9846 8.89392 19.9864 9.94571C19.9879 10.8146 19.8292 11.6266 19.5103 12.3816C19.1915 13.1367 18.7925 13.8234 18.3134 14.4415C17.8114 15.0597 17.2864 15.5979 16.7385 16.0562C16.1676 16.5373 15.6424 16.9383 15.1628 17.2592C14.6832 17.603 14.2949 17.8552 13.998 18.0158C13.6781 18.1763 13.5296 18.2566 13.5525 18.2566L12.7619 17.1947C12.9675 17.1029 13.2416 16.9195 13.5841 16.6446C13.9266 16.3925 14.2691 16.0832 14.6114 15.7168C14.9309 15.3504 15.2161 14.9498 15.4668 14.5149C15.7177 14.1029 15.8427 13.7026 15.8421 13.3139C15.8417 13.0852 15.7041 12.8568 15.4294 12.6286C15.1546 12.4233 14.857 12.1723 14.5363 11.8756C14.2158 11.6017 13.9179 11.2593 13.6429 10.8482C13.3678 10.4599 13.2298 9.97999 13.2289 9.40837C13.228 8.90534 13.3301 8.44786 13.5352 8.03595C13.7175 7.62407 13.9684 7.26924 14.288 6.97145C14.5848 6.69657 14.9388 6.47875 15.3501 6.318C15.7614 6.15725 16.1843 6.07651 16.6187 6.07577ZM7.29256 6.02144C7.81845 6.02055 8.29881 6.13406 8.73363 6.36198C9.16845 6.58989 9.54624 6.89793 9.86701 7.28609C10.1878 7.67426 10.44 8.1197 10.6238 8.62242C10.7848 9.14805 10.8657 9.7081 10.8667 10.3026C10.8687 11.4916 10.6191 12.5895 10.1178 13.5964C9.5936 14.6262 9.02346 15.5075 8.40734 16.2402C7.67713 17.1103 6.84389 17.9006 5.90763 18.611L4.91144 17.6866C5.11699 17.5491 5.36814 17.3314 5.66488 17.0337C5.93876 16.736 6.20111 16.3811 6.45192 15.9691C6.67992 15.5801 6.88501 15.1681 7.06719 14.7334C7.22651 14.2987 7.30583 13.8756 7.30513 13.464C7.30467 13.1896 7.13279 12.9612 6.78951 12.7789C6.44623 12.5966 6.06857 12.3686 5.65653 12.0949C5.2445 11.8212 4.86663 11.4674 4.52292 11.0336C4.17925 10.6226 4.00678 10.0398 4.00551 9.28526C4.00473 8.82796 4.09548 8.4048 4.27774 8.01579C4.46 7.62677 4.71094 7.28337 5.03055 6.98559C5.32729 6.68784 5.68129 6.44716 6.09255 6.26355C6.48099 6.10283 6.88099 6.02213 7.29256 6.02144Z" stroke="currentColor" fill="currentColor"></path></svg><p class="tw-antialiased tw-hidden tw-ml-2 tw-text-sm tw-font-bold tw-text-gray-700 group-hover:tw-underline md:tw-block lg:tw-hidden xl:tw-block">Cite</p></button></div></div></div><div class="last:tw-pr-0"><div class="tw-relative tw-inline-block tw-text-left"><div><button class="tw-group tw-inline-flex tw-items-center tw-px-3 tw-py-2 tw-transition-all tw-border-2 tw-rounded-md tw-group tw-bg-white tw-border-gray-100 hover:tw-bg-gray-100 focus:tw-outline-none" id="headlessui-menu-button-:R5ml6:" type="button" aria-haspopup="true" aria-expanded="false"><svg xmlns="http://www.w3.org/2000/svg" fill="none" viewBox="0 0 24 24" stroke-width="2" stroke="currentColor" aria-hidden="true" class="tw-w-5 tw-h-5 tw-text-gray-600"><path stroke-linecap="round" stroke-linejoin="round" d="M8.684 13.342C8.886 12.938 9 12.482 9 12c0-.482-.114-.938-.316-1.342m0 2.684a3 3 0 110-2.684m0 2.684l6.632 3.316m-6.632-6l6.632-3.316m0 0a3 3 0 105.367-2.684 3 3 0 00-5.367 2.684zm0 9.316a3 3 0 105.368 2.684 3 3 0 00-5.368-2.684z"></path></svg><p class="tw-antialiased tw-hidden tw-ml-2 tw-text-sm tw-font-bold tw-text-gray-700 group-hover:tw-underline md:tw-block lg:tw-hidden xl:tw-block">Share</p></button></div></div></div><a href="https://www.researchsquare.com/article/rs-3994852/v1.pdf?c=1709236367000" target="_blank" rel="noopener noreferrer" class="tw-text-blue-600 hover:tw-text-blue-800 hover:tw-underline tw-inline-flex tw-items-center tw-px-3.5 tw-py-1.5 tw-transition-all tw-border-2 tw-rounded-md tw-group tw-border-blue-50 tw-bg-blue-50 hover:tw-bg-blue-100 hover:tw-border-blue-100 focus:tw-outline-none tw-text-blue-600 hover:tw-text-blue-800 hover:tw-underline tw-ml-3"><svg xmlns="http://www.w3.org/2000/svg" fill="none" viewBox="0 0 24 24" stroke-width="2" stroke="currentColor" aria-hidden="true" class="tw-w-5 tw-h-5"><path stroke-linecap="round" stroke-linejoin="round" d="M12 10v6m0 0l-3-3m3 3l3-3m2 8H7a2 2 0 01-2-2V5a2 2 0 012-2h5.586a1 1 0 01.707.293l5.414 5.414a1 1 0 01.293.707V19a2 2 0 01-2 2z"></path></svg><span class="tw-antialiased tw-ml-2 tw-text-sm tw-font-bold"><span class="tw-hidden xl:tw-contents">Download</span> PDF</span></a></div><div class="tw-mx-2.5 lg:tw-mx-0 tw-border-2 tw-border-gray-100 tw-bg-white tw-rounded-lg tw-hidden lg:tw-block lg:tw-mt-4"><div class="tw-px-4"><button type="button" class="tw-min-w-full focus:tw-outline-none tw-group"><div class="tw-flex tw-items-center tw-justify-between"><div class="tw-w-full tw-py-2"><div class="tw-flex tw-items-center"><h3 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-base">Status:</h3><div class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700 tw-ml-2"><p class="tw-antialiased tw-text-left tw-text-sm tw-color-gray-800">Posted</p></div></div></div><div class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700 tw-my-2 tw-flex tw-items-center tw-duration-300 tw-transform tw-bg-gray-100 group-hover:tw-bg-gray-200"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black tw-text-gray-800 group-hover:tw-text-gray-900 tw-flex"></p><svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 20 20" fill="currentColor" aria-hidden="true" class="tw-text-gray-800 group-hover:tw-text-gray-900 tw-h-6 tw-w-6 tw-flex-shrink-0 tw-rounded-full tw-transform tw-duration-300"><path fill-rule="evenodd" d="M5.293 7.293a1 1 0 011.414 0L10 10.586l3.293-3.293a1 1 0 111.414 1.414l-4 4a1 1 0 01-1.414 0l-4-4a1 1 0 010-1.414z" clip-rule="evenodd"></path></svg></div></div></button></div><div class="tw-px-4 tw-border-t-2 tw-border-gray-100"><div class="tw-flex tw-items-start tw-justify-between tw-min-w-full"><div class="tw-py-2"><div class="tw-text-left"><h3 class="tw-antialiased tw-font-bold tw-text-left tw-text-blue-900 tw-text-base">Version <!-- -->1</h3><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black tw-text-gray-700">posted<!-- --> </p></div></div></div><div class="tw-pt-1"><div class="tw-pb-1"><p class="tw-antialiased tw-text-left tw-text-sm tw-text-black"><span class="tw-rounded-xl tw-font-bold tw-px-3 tw-py-1 tw-bg-gray-100 tw-text-gray-700 tw-flex tw-justify-center tw-w-full tw-mb-2">You are reading this <!-- -->latest<!-- --> <!-- -->preprint<!-- --> version</span></p></div></div></div></div></div></div></div></div></div></div></div></div></div><div class="original-css"><footer class="section b-pb-60-d b-pb-20-m"><div class="tw-justify-between tw-block tw-p-4 tw-space-y-6 lg:tw-space-x-6 lg:tw-space-y-0 rs-container lg:tw-flex"><div class="tw-max-w-lg tw-b-mb-20"><a href="/"><img class="logo-rs" src="/static/img/logos/logo-rs.svg" alt="Research Square"/></a><p class="footer-desc b-pb-15">Research Square lets you share your work early, gain feedback from the community, and start making changes to your manuscript prior to peer review in a journal.</p><p class="footer-desc">As a division of Research Square Company, we’re committed to making research communication faster, fairer, and more useful. We do this by developing innovative software and high quality services for the global research community. Our growing team is made up of researchers and industry professionals working together to solve the most critical problems facing scientific publishing.</p><div class="icons is-flex b-pt-25 b-pb-20"><a href="https://twitter.com/researchsquare" rel="nofollow"><img src="/static/img/icons/icon-twitter.svg" alt="Twitter logo"/></a><a href="https://www.facebook.com/researchsquare" rel="nofollow"><img src="/static/img/icons/icon-facebook.svg" alt="Facebook logo"/></a><a href="https://www.youtube.com/c/researchsquare" rel="nofollow"><img src="/static/img/icons/icon-youtube.svg" alt="YouTube logo"/></a><a href="https://vimeo.com/researchsquare" rel="nofollow"><img src="/static/img/icons/icon-vimeo.svg" alt="Vimeo logo"/></a><a href="https://www.instagram.com/researchsquarecompany/" rel="nofollow"><img src="/static/img/icons/icon-instagram.svg" alt="Instagram logo"/></a><a href="https://www.linkedin.com/company/research-square-co" rel="nofollow"><img src="/static/img/icons/icon-linkedin.svg" alt="LinkedIn logo"/></a></div><div class="researcher-app"><a href="https://www.researcher-app.com/?utm_source=researchsquare&utm_medium=referral&utm_campaign=&utm_content=logo" class="align-m" target="_blank" rel="noopener noreferrer"><h6 class="color-text-90 b-pr-10">Also discoverable on</h6><img src="/static/img/logos/logo-researcher-app.svg" alt="ResearcherApp logo"/></a></div></div><div class="tw-justify-between tw-block tw-space-y-6 lg:tw-space-x-6 lg:tw-space-y-0 lg:tw-flex"><div id="platform"><h5 class="caps color-text-b4 b-mt-3 b-pb-15 b-mr-40-d">Platform</h5><p class="footer-link"><a href="/researchers/preprints">About</a></p><p class="footer-link"><a href="/about">Our Team</a></p><p class="footer-link"><a href="/researchers/in-review">In Review</a></p><p class="footer-link"><a href="/legal/editorial">Editorial Policies</a></p><p class="footer-link"><a href="/advisory-board">Advisory Board</a></p><p class="footer-link"><a target="_blank" rel="noopener noreferrer" href="https://support.researchsquare.com">Help Center</a></p></div><div id="resources"><h5 class="caps color-text-b4 b-mt-3 b-pb-15 b-mr-20-d">Resources</h5><p class="footer-link"><a href="/researchers">Author Services</a></p><p class="footer-link"><a href="/research-quality-evaluation">Research Quality Evaluation</a></p><p class="footer-link"><a href="/accessibility">Accessibility</a></p><p class="footer-link"><a href="/request-api">API Access</a></p><p class="footer-link"><a href="/rss.xml" rel="alternate" type="application/rss+xml">RSS feed</a></p><p class="footer-link"><button data-cc-action="preferences">Manage Cookie Preferences</button></p></div><div id="company"><h5 class="caps color-text-b4 b-mt-3 b-pb-15 b-mr-50-d">Company</h5><p class="footer-link"><a href="https://company.researchsquare.com/" target="_blank" rel="noopener noreferrer">About Us</a></p><p class="footer-link"><a href="https://company.researchsquare.com/careers" target="_blank" rel="noopener noreferrer">Careers</a></p><p class="footer-link"><a href="https://company.researchsquare.com/publishing-partners" target="_blank" rel="noopener noreferrer">Partner With Us</a></p><p class="footer-link"><a href="https://company.researchsquare.com/responsibility" target="_blank" rel="noopener noreferrer">Responsibility</a></p><p class="footer-link"><a href="https://company.researchsquare.com/media" target="_blank" rel="noopener noreferrer">Press</a></p></div></div></div></footer><footer class="section columns tail"><div class="column is-narrow is-paddingless"><div class="navbar"><p class="navbar-item">© Research Square <!-- -->2024<!-- --> | ISSN 2693-5015 (online)<!-- --> </p><a class="navbar-item" href="/legal/privacy">Privacy Policy</a><a class="navbar-item" href="/legal/terms-of-service">Terms of Service</a><a class="navbar-item" href="/legal/do-not-sell-my-personal-information">Do Not Sell My Personal Information</a></div></div></footer></div></div></div><script id="__NEXT_DATA__" type="application/json">{"props":{"pageProps":{"initialData":{"identity":"rs-3994852","acceptedTermsAndConditions":true,"allowDirectSubmit":true,"archivedVersions":[],"articleType":"Method Article","associatedPublications":[],"authors":[{"id":275264437,"identity":"66c740e0-fc39-40c9-ac4b-33098663dd56","order_by":0,"name":"Paul V. Lehmann","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Paul","middleName":"V.","lastName":"Lehmann","suffix":""},{"id":275264438,"identity":"2b196c32-6417-447b-ae29-b2f689d65f7c","order_by":1,"name":"Alexey Y. Karulin","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Alexey","middleName":"Y.","lastName":"Karulin","suffix":""},{"id":275264439,"identity":"6ffb771c-a0a0-4072-8bef-c9322bc5b661","order_by":2,"name":"Noémi Becza","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Noémi","middleName":"","lastName":"Becza","suffix":""},{"id":275264440,"identity":"d7a97502-ba21-40e1-a193-73b57b2d582f","order_by":3,"name":"Lingling Yao","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Lingling","middleName":"","lastName":"Yao","suffix":""},{"id":275264441,"identity":"86fee9f7-bdcb-4921-b9b6-6837319c8765","order_by":4,"name":"Zhigang Liu","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Zhigang","middleName":"","lastName":"Liu","suffix":""},{"id":275264442,"identity":"c2912f4f-bd9f-47dc-8c32-94af134d07ce","order_by":5,"name":"Jack Chepke","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Jack","middleName":"","lastName":"Chepke","suffix":""},{"id":275264443,"identity":"8491a67c-f322-42c2-8d49-3dd94ceead67","order_by":6,"name":"Andrea Maul-Pavicic","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Andrea","middleName":"","lastName":"Maul-Pavicic","suffix":""},{"id":275264444,"identity":"a4805269-839a-4774-a606-57db7552f487","order_by":7,"name":"Carla Wolf","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Carla","middleName":"","lastName":"Wolf","suffix":""},{"id":275264445,"identity":"bde5eeb9-7d07-49e6-8b72-74d1a752c437","order_by":8,"name":"Sebastian Köppert","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Sebastian","middleName":"","lastName":"Köppert","suffix":""},{"id":275264446,"identity":"f12b1321-bf9e-4d26-becf-284bb87d682d","order_by":9,"name":"Alexis V. Valente","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Alexis","middleName":"V.","lastName":"Valente","suffix":""},{"id":275264447,"identity":"22767266-85b4-4303-aa88-d989183cf1f1","order_by":10,"name":"Anton V. Gorbachev","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Anton","middleName":"V.","lastName":"Gorbachev","suffix":""},{"id":275264448,"identity":"6bd7efd3-9af2-464f-adb8-d218292118ab","order_by":11,"name":"Magdalena Tary-Lehmann","email":"","orcid":"","institution":"Cellular Technology Limited","correspondingAuthor":false,"prefix":"","firstName":"Magdalena","middleName":"","lastName":"Tary-Lehmann","suffix":""},{"id":275264449,"identity":"291bdbb7-4c0d-4d74-a496-6f26d582337f","order_by":12,"name":"Greg A. Kirchenbaum","email":"data:image/png;base64,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","orcid":"https://orcid.org/0000-0001-6463-7623","institution":"Cellular Technology Limited","correspondingAuthor":true,"prefix":"","firstName":"Greg","middleName":"A.","lastName":"Kirchenbaum","suffix":""}],"badges":[],"createdAt":"2024-02-27 21:22:04","currentVersionCode":1,"declarations":{"humanSubjects":true,"vertebrateSubjects":false,"conflictsOfInterestStatement":true,"humanSubjectEthicalGuidelines":true,"humanSubjectConsent":true,"humanSubjectClinicalTrial":false,"humanSubjectCaseReport":false,"vertebrateSubjectEthicalGuidelines":false},"doi":"10.21203/rs.3.rs-3994852/v1","doiUrl":"https://doi.org/10.21203/rs.3.rs-3994852/v1","draftVersion":[],"editorialEvents":[],"editorialNote":"","failedWorkflow":false,"files":[{"id":51816597,"identity":"31fd79ee-cde4-4c39-96b5-f9fa23d09d11","added_by":"auto","created_at":"2024-02-29 14:52:47","extension":"pdf","order_by":0,"title":"","display":"","copyAsset":false,"role":"manuscript-pdf","size":650194,"visible":true,"origin":"","legend":"","description":"","filename":"manuscript.pdf","url":"https://assets-eu.researchsquare.com/files/rs-3994852/v1/b608e950-1ad6-473a-9e87-887ceb062f49.pdf"},{"id":51815960,"identity":"8632b39d-b61e-4fc4-a27b-4276066dccc3","added_by":"auto","created_at":"2024-02-29 14:44:46","extension":"docx","order_by":1,"title":"","display":"","copyAsset":false,"role":"supplement","size":12624,"visible":true,"origin":"","legend":"","description":"","filename":"Appendix.docx","url":"https://assets-eu.researchsquare.com/files/rs-3994852/v1/69beb5e2c44fd7825dd86117.docx"}],"financialInterests":"The authors declare potential competing interests as follows: All authors are employees of CTL and may hold stock.","formattedTitle":"\u003cp\u003e\u003cem\u003e\u003cstrong\u003eTheoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays\u003c/strong\u003e\u003c/em\u003e\u003c/p\u003e","fulltext":[{"header":"1.0. Introduction","content":"\u003cp\u003eDespite the fact that the ELISPOT assay system was first developed for quantifying the abundance of antigen-specific antibody-secreting B cells (ASC) [\u003cspan citationid=\"CR1\" class=\"CitationRef\"\u003e1\u003c/span\u003e, \u003cspan citationid=\"CR2\" class=\"CitationRef\"\u003e2\u003c/span\u003e], it is the T cell ImmunoSpot assay (Note 1; a link to all \u0026ldquo;Notes\u0026rdquo; can be found at the end of this paper, under \u0026ldquo;\u003cspan refid=\"Sec37\" class=\"InternalRef\"\u003eAppendix\u003c/span\u003e\u0026rdquo;) which were introduced much later [\u003cspan citationid=\"CR3\" class=\"CitationRef\"\u003e3\u003c/span\u003e], that has become a mainstay for T cell immune monitoring [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e]. This happened after modification of the original T cell ELISPOT protocol enabled the assay to reliably reveal secretory footprints of individual antigen-specific T cells ([\u003cspan citationid=\"CR5\" class=\"CitationRef\"\u003e5\u003c/span\u003e, \u003cspan citationid=\"CR6\" class=\"CitationRef\"\u003e6\u003c/span\u003e], and Note 2), and the development of automated, objective, and validated machine reading approaches rendered the assay suitable for high throughput analysis and compliant with regulatory guidelines [\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e, \u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e] (Note 3). The urgent need for measuring the contribution of the T cell compartment to immune responses, coupled with the ease of standardization, high sensitivity, and high throughput capacity together rendered T cell ImmunoSpot assays an attractive alternative to flow cytometry-based analysis (both being used initially for basic discovery, and now increasingly for clinical analysis [\u003cspan additionalcitationids=\"CR10 CR11 CR12\" citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eIn contrast to T cell assays, to date, B cell ImmunoSpot assays have not been intensively exploited in either the basic research or clinical arenas. Perhaps the main technical reason for this is that the original B cell ImmunoSpot protocol was suitable for only a limited set of antigens. However, recently, this problem has been overcome with the implementation of an affinity capture coating approach [\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e], which enables rapid development of ImmunoSpot assays for essentially any desired antigen. On the other hand, it is also likely that there was a major conceptual reason that B cell ImmunoSpot assays were not exploited: there has been the widely-held belief that sufficient information on B cell immunity could be obtained by simple measurements of serum antibodies, a notion that rendered it unnecessary to struggle with complex, fragile, and more difficult to preserve cell samples. However, this view is no longer tenable since we have learned that detection of memory B cells (B\u003csub\u003emem\u003c/sub\u003e) reflects the existence of antigen-specific immunity in infectious- [\u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e, \u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e] and autoimmune- [\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e] settings much more reliably than measurements of serum antibodies. Moreover, with serum antibodies possessing a half-life of only weeks (Note 4), and the plasma cells that replenish them apparently also having shorter lifespans than originally believed [\u003cspan citationid=\"CR18\" class=\"CitationRef\"\u003e18\u003c/span\u003e], we now understand that in some instances serum antibodies only provide evidence of quite recent immune encounters [\u003cspan additionalcitationids=\"CR20 CR21\" citationid=\"CR19\" class=\"CitationRef\"\u003e19\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR22\" class=\"CitationRef\"\u003e22\u003c/span\u003e]. In contrast, B\u003csub\u003emem\u003c/sub\u003e are long-lived and thus not only enable a rapid antibody response upon antigen reencounter, but they can also undergo further refinement of their fine specificity to accelerate the response to new antigenic challenges, e.g., when encountering variant viruses (reviewed in [\u003cspan citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e]). Newly developed modifications of B cell ImmunoSpot assays also permit the assessment of B\u003csub\u003emem\u003c/sub\u003e cross-reactivity at single-cell resolution [\u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e] as well as the detailed investigation of the affinity distribution/maturation of an antigen-specific B\u003csub\u003emem\u003c/sub\u003e repertoire [\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e]. Although immune monitoring assays that enable the characterization of antigen-specific B cells, whether based on flow cytometry or ImmunoSpot assays, have already been available for some time in the research arena, adapting such complex assays for use in the clinical realm has been challenging at several levels. In particular, although guidelines for compliance with industry standards in a regulated environment have been developed for measurements of soluble analytes in liquids [\u003cspan citationid=\"CR26\" class=\"CitationRef\"\u003e26\u003c/span\u003e], they require adaptation for cell-based test systems. This has already been accomplished for T cell ImmunoSpot assays [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e, \u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e] that enumerate antigen-specific T cells within PBMC by detecting cytokines secreted upon specific antigen encounter. Subsequently, T cell ImmunoSpot testing has become an assay of choice for evaluation of cell-mediated immune responses in many clinical trials [\u003cspan additionalcitationids=\"CR10 CR11 CR12\" citationid=\"CR9\" class=\"CitationRef\"\u003e9\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR13\" class=\"CitationRef\"\u003e13\u003c/span\u003e]; however, such guidelines do not yet exist for B cell ImmunoSpot assays.\u003c/p\u003e \u003cp\u003eSupplemental Fig.\u0026nbsp;1 depicts distinct types of B cell ImmunoSpot assays used for immune monitoring purposes (a link to all \u0026ldquo;Supplemental Figures\u0026rdquo; can be found at the end of this paper, under \u0026ldquo;\u003cspan refid=\"Sec37\" class=\"InternalRef\"\u003eAppendix\u003c/span\u003e\u0026rdquo;). Because these assays differ fundamentally from T cell ImmunoSpot tests in many aspects, here we describe B cell ImmunoSpot assay development, qualification, and validation recommendations that build on those developed for T cell ImmunoSpot assays but take into consideration the distinguishing features of B cell biology. In doing so, we first outline these distinguishing features; then, following the definitions and experimental templates provided by Bauer \u003cem\u003eet al\u003c/em\u003e. [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e] for T cell ImmunoSpot assays, we provide recommendations for B cell ImmunoSpot assay protocols. As a model for B cell ImmunoSpot assay development, qualification, and validation, we leveraged the SARS-CoV-2 Spike (S)-antigen-specific B cell response elicited following SARS-CoV-2 infection and/or COVID-19 mRNA vaccination of \u0026ldquo;na\u0026iuml;ve\u0026rdquo; subjects.\u003c/p\u003e"},{"header":"2.0 Theoretical considerations for the verification and validation of antigen-specific B cell ImmunoSpot assays.","content":"\u003cdiv id=\"Sec3\" class=\"Section2\"\u003e \u003ch2\u003e2.1. B cell biology-dictated implications for verification/validation\u003c/h2\u003e \u003cp\u003eThere is a considerable gap between the terminology used by basic scientists (in whose realm antigen-specific B cells assays are primarily used presently, and from where knowledge gained thus far needs to be transferred) and the regulated world (that increasingly attempts to adopt such cellular assays for clinical trial monitoring and diagnostics). Therefore, in this communication we will always begin with defining the terminology used in the regulated space so that it also becomes transparent to basic scientists as well.\u003c/p\u003e \u003cp\u003eB cells are the only cell type capable of secreting antibody (immunoglobulin, Ig). Moreover, those B cells that have responded in a T helper cell-dependent manner can switch from secreting IgM molecules (produced by na\u0026iuml;ve B cells) to the production of the other Ig classes: namely, IgA (subclasses IgA1 and IgA2), IgE, and IgG (subclasses IgG1-IgG4) (Note 5 \u0026amp; 6). Importantly, B\u003csub\u003emem\u003c/sub\u003e are resting lymphocytes that do not spontaneously secrete antibodies but can do so rapidly following (re-)activation by antigen. This is typically also dependent on antigen-specific, cognate T cell help \u003cem\u003ein vivo\u003c/em\u003e but in addition it can be induced \u003cem\u003ein vitro\u003c/em\u003e following stimulation with certain mitogens capable of activating all B cells polyclonally (i.e., regardless of their intrinsic antigen specificity). Such polyclonal stimulation is required to detect resting B\u003csub\u003emem\u003c/sub\u003e by ImmunoSpot \u003cem\u003eex vivo\u003c/em\u003e (Note 7). Under these conditions, B\u003csub\u003emem\u003c/sub\u003e transition, over the course of several days (optimally 5 days, Supplemental Fig.\u0026nbsp;2A-F), into ASC. Consequently, one can safely conclude that detecting any number of (even a single) antigen-specific ASC that produced class-switched Ig following polyclonal stimulation of PBMC identifies the presence of antigen-specific B\u003csub\u003emem\u003c/sub\u003e. Even if cross-reactive, such B\u003csub\u003emem\u003c/sub\u003e can give rise to a rapid-onset secondary immune response. The immune system operates very efficiently with low numbers of memory lymphocytes (Note 8).\u003c/p\u003e \u003cp\u003eAs resting B\u003csub\u003emem\u003c/sub\u003e do not spontaneously secrete antibody, antigen-specific ASC are rarely detectable in freshly isolated blood (except a few weeks after initiation of an immune response, see below). This is the case even if antigen-specific B\u003csub\u003emem\u003c/sub\u003e are found to be abundant in that sample after \u003cem\u003ein vitro\u003c/em\u003e mitogenic stimulation (i.e., after the B\u003csub\u003emem\u003c/sub\u003e have been polyclonally activated to become ASC, as illustrated on a sample isolated\u0026thinsp;\u0026gt;\u0026thinsp;125 days following recovery from SARS-CoV-2 infection in Supplemental Fig.\u0026nbsp;3A \u003cem\u003evs.\u003c/em\u003e B). However, ~\u0026thinsp;1 week after antigen exposure \u003cem\u003ein vivo\u003c/em\u003e, ASC can be detected directly \u003cem\u003eex vivo\u003c/em\u003e in the blood (Supplemental Fig.\u0026nbsp;3C and D). Such ASC are not B\u003csub\u003emem\u003c/sub\u003e cells; they are plasmablasts that appear in the blood as they migrate from the lymphoid tissue in which they became activated to the bone marrow and other immunological niches where they may become resident as plasma cells (PC). Such ASC can readily be detected in ImmunoSpot assays by seeding the PBMC into the test system without prior \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation. Of note, most of these plasmablasts are specific for the antigen that triggered the immune response \u003cem\u003ein vivo\u003c/em\u003e (Supplemental Fig.\u0026nbsp;3C and D).\u003c/p\u003e \u003cp\u003eDetecting such spontaneously antibody-secreting antigen-specific plasmablasts has considerable and thus far largely unexploited immunodiagnostic potential. In the case of B cell-mediated autoimmune conditions; for example, the appearance of these cells can reveal a flare of the disease [\u003cspan citationid=\"CR17\" class=\"CitationRef\"\u003e17\u003c/span\u003e]. Similarly, it is likely to reflect on the reactivation of latent viruses in an immune compromised state (e.g., Cytomegalovirus or Epstein-Barr virus) or might indicate the initiation of transplant rejection episodes. While the appearance of peripheral blood ASC secreting Ig classes/subclasses other than IgA or IgM (see Note 9) by itself already documents an ongoing immune response, knowledge of the specificity of these ASC offers so far underutilized opportunities for identifying the antigen(s) that trigger(s) untoward immune responses. Examples are identifying the autoantigens in autoimmune diseases, environmental agents causing allergic reactions, and those responsible for flares of inflammation due to reactivation of persisting infections. Inherent challenges with such assessments are the transient appearance of such antibody-secreting plasmablasts in the blood, as well as the possibility that ASC in some conditions may reside predominantly in the tissue and therefore would not be present in the blood.\u003c/p\u003e \u003cp\u003eAntigen-specific B cell ImmunoSpot assays for detecting such circulating plasmablasts or B\u003csub\u003emem\u003c/sub\u003e differ only in the nature of the PBMC (or other cell isolate) to be tested; for the former, the cells are seeded into the ImmunoSpot test plates without any additional treatment, whereas for the latter, the cells are plated after 5 days of \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation. In both cases, the scope of the assay is the same: to determine unambiguously the number/frequency of antigen-specific ASC producing a certain Ig class/subclass within either all cells plated, or within all B cells secreting that Ig class/subclass (Note 10).\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec4\" class=\"Section2\"\u003e \u003ch2\u003e2\u003cem\u003e.2. Assay optimization for detecting antigen-specific ASC at single cell resolution\u003c/em\u003e\u003c/h2\u003e \u003cp\u003eThe overall scope for optimizing B cell ImmunoSpot assays can be broken down into two separate components. The first can be readily accomplished: detecting plate-bound antibody secretory footprints generated by individual ASC once the capture conditions for these antibodies have been optimized. The second is more challenging: the coating of the antigen itself to the membrane at a sufficiently high density for the antigen-specific Ig released by ASC to be efficiently captured on the membrane. Fulfilling this latter requirement has caused considerable challenges in the past, but these have now been overcome by the technique of affinity coating of the antigen [\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e]. (See also Supplemental Fig.\u0026nbsp;1, A \u003cem\u003evs\u003c/em\u003e. B),\u003c/p\u003e \u003cp\u003eSupplemental Fig.\u0026nbsp;4A shows secretory footprints that were generated by a murine B cell hybridoma when incubated on a membrane coated with high-affinity anti-mouse Igk capture antibody (of goat origin; for a description of this type of assay refer to Supplemental Fig.\u0026nbsp;1, panel C). When high-affinity anti-mouse IgG detection antibodies are used to visualize the plate-bound murine (B cell hybridoma-derived) antibody, pristine spot-forming units (SFU) become visible. Plating the hybridoma cells in serial dilution and counting the resulting SFU using a suitable reader reveals a near perfect linear relationship between the number of hybridoma cells plated per well and the number of SFU detected per well within a defined cell input range, revealing that 56% of the hybridoma cells were capable of generating a secretory footprint during the assay incubation period (Supplemental Fig.\u0026nbsp;4C, Notes 11 \u0026amp; 12). Supplemental Fig.\u0026nbsp;4D shows secretory footprints generated by B cell blasts (following \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation of PBMC) detected in an analogous manner using species-specific detection reagents; with these too, cell numbers plated and SFU counts detected precisely follow a linear function (Supplemental Fig.\u0026nbsp;4F). In both instances, the spot morphologies originating from the hybridomas or the B cell blasts exhibit very similar profiles in their size, shape, and density. Such data establish that the per cell antibody productivity of the hybridomas and that of B cell blasts during the analyte capture period of the assay were both clearly detectable. Therefore, the verification that secretory footprints originating from single hybridoma cells are being visualized implies the same for the detection of human ASC. In other words, these types of tests verify that the detection reagents used indeed detect secretory footprints of individual ASC. To control for the quality of the detection reagents\u0026rsquo; performance, we recommend the inclusion of positive controls in which polyclonally stimulated PBMC (because of the high inter-individual variability among donors, preferably pre-characterized PBMC) reference samples [\u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e] are tested in serial dilution after pan Ig capture for Ig class/subclass-producing ASC (See Supplemental Fig.\u0026nbsp;5).\u003c/p\u003e \u003cp\u003eThe real challenge for antigen-specific B cell ImmunoSpot assay development has been efficient coating of the membrane with the antigen of interest. For detecting antigen-specific ASC, the membrane must be densely coated with antigen. The membrane best suited for ImmunoSpot analysis is a PVDF fibered filter [\u003cspan citationid=\"CR7\" class=\"CitationRef\"\u003e7\u003c/span\u003e] that, due to its hydrophobicity and fractal surface structure, excels in binding proteins [\u003cspan citationid=\"CR28\" class=\"CitationRef\"\u003e28\u003c/span\u003e], or to be more precise in this context, to bind proteins with sufficient hydrophobic regions, such as Ig. For such hydrophobic proteins, the classic, direct membrane-absorption-based coating strategy suffices for developing antigen-specific B cell ImmunoSpot assays. However, such proteins are more the exception than the rule amongst antigens of interest; and, for the remainder, affinity capture of the antigen greatly reduces the quantity of protein required to achieve the necessary coating density. This can be accomplished by coating the membrane first with an Ig [\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e, \u003cspan citationid=\"CR15\" class=\"CitationRef\"\u003e15\u003c/span\u003e, \u003cspan citationid=\"CR29\" class=\"CitationRef\"\u003e29\u003c/span\u003e] or with an alternative capture protein that is sufficiently hydrophobic (see Supplemental Fig.\u0026nbsp;1B). This specific \u0026ldquo;antigen-capture reagent\u0026rdquo; will then bind with high affinity to the soluble antigen in solution (Note 13). For example, recombinant proteins are commonly engineered to contain a short amino acid sequence tag (e.g., His-tag) that facilitates their purification via affinity chromatography; the same tags can be used to achieve high density protein coating via plate-bound anti-tag capture antibodies [\u003cspan citationid=\"CR14\" class=\"CitationRef\"\u003e14\u003c/span\u003e]. Notably, the anti-tag capture approach is far more universal than direct antigen coating as it enables the high affinity capture of different unrelated proteins that need only to share a common affinity tag. Therefore, the recent introduction of affinity capture coating has made detection of antigen-specific ASC via B cell ImmunoSpot analysis a generalizable immune monitoring tool (Note 14); failed past attempts with direct coating are likely one reason that this simple and powerful B cell ImmunoSpot technology did not find its place in the standard immune monitoring repertoire until now.\u003c/p\u003e \u003cp\u003eAs a rule of thumb, coating the PVDF membrane with 10 \u0026micro;g/mL of antigen-capture antibody, and then adding the antigen itself at 10 \u0026micro;g/mL will result in high density antigen coating. However, as both reagents are unique to the type of (or even batch of) antibody and antigen used, titrating both during the assay development phase is highly recommended for obtaining optimal antigen coating while also minimizing the amount of antigen-capture antibody and antigen required. Supplemental Fig.\u0026nbsp;6 shows spot morphologies seen with suboptimal vs. optimal coating. Of note, not only does the spot morphology deteriorate with suboptimal coating (to the point of becoming vague or even undetectable), but, as the antigen-density on the membrane decreases, just the high affinity end of the antigen-specific B cell repertoire becomes detectable [\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e]. When testing primary cell material containing B cells with different affinities for the antigen, coating can be considered optimal if a full spectrum of spot morphologies is detected, ranging from dense and sharp spots (produced by the high affinity end of the B cell repertoire) to small and faint, often also diffuse spots (representing the low affinity end of the repertoire); see also Supplemental Fig.\u0026nbsp;7 and Notes 15 \u0026amp; 16).\u003c/p\u003e \u003cp\u003eFor optimizing antigen coating conditions, reference PBMC are well-suited [\u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e] if available (Note 17). If unavailable, or when B cell reactivity to the antigen in question needs to be verified (as for autoimmunity or cancer, see Note 16), B cell hybridomas specific for that antigen can be used for antigen coating optimization. In case such hybridomas are not available, immunizing mice with the antigen of interest and testing the spleen cells of the immunized mice in a murine B cell ImmunoSpot assay is another option (Note 18). In either case, antigen coating optimization can be considered complete only if pristine spots are detected covering a wide range of sizes and morphologies (Note 19).\u003c/p\u003e \u003cp\u003eWe strongly advise principal investigators, study directors, auditors, and reviewers not to accept mere SFU counts as B cell ImmunoSpot data reports without visually verifying the quality of spots evaluated. Suitable analyzers will automatically retain raw well images and the results of the analysis as count overlays in a tamper-proof fashion, providing ease of access and transparent audit trails [\u003cspan citationid=\"CR8\" class=\"CitationRef\"\u003e8\u003c/span\u003e].\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec5\" class=\"Section2\"\u003e \u003ch2\u003e2.3. Count optimization for detecting secretory footprints of individual cells\u003c/h2\u003e \u003cdiv id=\"Sec6\" class=\"Section3\"\u003e \u003ch2\u003e2.3.1. Counting parameters for machine reading\u003c/h2\u003e \u003cp\u003eOnce assay development for visualization of secretory footprints generated by individual antibody-secreting B cells has been accomplished, the next step is counting them by machine reading. These secretory footprints (which we also refer to as SFU) are readily countable by eye under a dissection microscope (ELISPOT) or a fluorescent microscope (FluoroSpot), but visual counting is, with these assays being high throughput and ideally high content in nature, tedious, imprecise, and leaves no audit trails. Based on theoretical modeling [\u003cspan citationid=\"CR30\" class=\"CitationRef\"\u003e30\u003c/span\u003e] and as experimentally verified [\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e], machine reading of direct B cell assays is needed to precisely resolve four distinct spot morphologies at the extremes and all transitions in between (see Supplemental Fig.\u0026nbsp;7D and [\u003cspan citationid=\"CR60\" class=\"CitationRef\"\u003e60\u003c/span\u003e]). Regarding spot intensity (the first dimension), the brightest spots originate from ASC that produced high affinity antibodies for the antigen of interest, whereas faint or dim spots are generated by ASC secreting lower affinity antibodies. In the second dimension, spot sizes reflect per cell productivity (Note 20). Suitable software can accurately assess spot sizes and intensities (Supplemental Figs.\u0026nbsp;7B, C and D) and thus permit not only precise SFU counting, but also high content analysis for assessing the affinity spectrum of an antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived ASC repertoire [\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e] (Note 21).\u003c/p\u003e \u003cp\u003eDue to clonal diversity of the na\u0026iuml;ve antigen-specific B cell repertoire originally engaged, and the subsequent emergence of subclones with diverse affinities for the antigen generated through the process of affinity maturation (Note 22), the antigen-specific B\u003csub\u003emem\u003c/sub\u003e repertoire in most instances will include a wide spectrum of affinities. This can range from B cell receptors (BCR)/secreted antibodies with weak to very weak binding (K\u003csub\u003eD\u003c/sub\u003e\u0026gt;10\u003csup\u003e\u0026minus;\u0026thinsp;4\u003c/sup\u003e) to very strong (K\u003csub\u003eD\u003c/sub\u003e\u0026lt;10\u003csup\u003e\u0026minus;\u0026thinsp;11\u003c/sup\u003e) [\u003cspan additionalcitationids=\"CR32 CR33 CR34 CR35 CR36 CR37\" citationid=\"CR31\" class=\"CitationRef\"\u003e31\u003c/span\u003e\u0026ndash;\u003cspan citationid=\"CR38\" class=\"CitationRef\"\u003e38\u003c/span\u003e], encompassing greater than a 10-million-fold potential difference in the binding strength of the BCR/antibody to antigen (Note 23). Overall, antibody affinity/avidity for antigen is (in addition to the Ig class/subclass) the critical determining factor for their biological effector potential (Note 24). As all B\u003csub\u003emem\u003c/sub\u003e have passed an affinity-based selection criterion when the parental (germline) na\u0026iuml;ve B cell was first engaged in the immune response, and as the hypermutated subclones of those parental cells have in most cases undergone additional rounds of affinity-based positive selection (Note 22), the B\u003csub\u003emem\u003c/sub\u003e repertoire secreting IgG, IgA, and IgE antibodies (Note 25) consists primarily of cells secreting Ig towards the higher affinity end of the spectrum. For optimized antigen-specific IgG (and IgA) assays, there are relatively few \u0026ldquo;ambiguous\u0026rdquo; spots observed in assays detecting B\u003csub\u003emem\u003c/sub\u003e-derived ASC producing these class-switched antibodies in na\u0026iuml;ve vs immunized individuals (Supplemental Table\u0026nbsp;1 and Supplemental Fig.\u0026nbsp;8A) reflecting the individual\u0026rsquo;s antigen-primed status with near perfect accuracy. The analysis of IgM antibodies produced by broadly-reactive na\u0026iuml;ve B cells after \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation, however, provides a different level of conceptual and technical challenge (Note 26).\u003c/p\u003e \u003c/div\u003e \u003c/div\u003e \u003cdiv id=\"Sec7\" class=\"Section2\"\u003e \u003ch2\u003e2.4 Accurate ASC frequency assessment\u003c/h2\u003e \u003cp\u003eWhen measuring frequencies of B\u003csub\u003emem\u003c/sub\u003e-derived antigen-specific ASC using the direct assay, we need to keep in mind that not only do the frequencies of ASC producing different Ig classes (and subclasses) span orders of magnitude, and additionally exhibit considerable variation among individuals [\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e] and Supplemental Fig.\u0026nbsp;5), but also the number of antigen-specific B cells within each class/subclass spans a similarly wide range. A representative illustration of frequency variations for B\u003csub\u003emem\u003c/sub\u003e\u0026ndash;derived IgG\u003csup\u003e+\u003c/sup\u003e ASC specific for different antigens in a cohort of healthy subjects is provided in Supplemental Fig.\u0026nbsp;9. The data for this figure were obtained by seeding polyclonally stimulated PBMC at a fixed number of 3 x 10\u003csup\u003e5\u003c/sup\u003e PBMC per well for screening purposes. When analyzed in the context of Supplemental Fig.\u0026nbsp;10 (which shows that SFU counts\u0026thinsp;\u0026gt;\u0026thinsp;100 per well are underestimating the actual number of ASC present in a sample), it becomes clear that testing samples at a single PBMC concentration precludes accurate frequency assessments; many of the data points obtained are either over or under the reliable quantification limit of the assay when a single cell concentration (e.g. 2 x 10\u003csup\u003e5\u003c/sup\u003e per well) is used for testing.\u003c/p\u003e \u003cdiv id=\"Sec8\" class=\"Section3\"\u003e \u003ch2\u003e2.4.1 Upper quantification limit\u003c/h2\u003e \u003cp\u003eThe upper quantification limit of B cell ImmunoSpot assays is caused by overcrowding of the spots. While the individual ASC secretory footprints can be clearly visualized when there is sufficient space for each to be captured without overlap, this does not start to occur for antigen-specific assays until around 100 SFU per well (examples of which are shown in Supplemental Fig.\u0026nbsp;10) and for pan Ig assays (that display tighter footprints) at ~\u0026thinsp;300 SFU per well (see Supplemental Fig.\u0026nbsp;4, and Note 27). In addition, as the number of ASC per well increases, the \u0026ldquo;ELISA effect\u0026rdquo; increases in magnitude. Specifically, the ELISA effect occurs due to an increased concentration of ASC-derived antigen-specific antibody in the supernatant that is captured on the antigen-coated membrane independent of the original cellular source. Consequently, the ELISA effect elevates the overall background staining of the assay membrane and interferes with the detection not only of faint spots, but also the outlines that define individual ASC-derived secretory footprints (Note 28). Defining the upper quantification limit (ULOQ) as the maximal number of ASC which can be detected in the assay well, is assay-dependent at ~\u0026thinsp;100 SFU per well for antigen-specific, and ~\u0026thinsp;300 SFU per well for pan Ig tests. However, the cells can be sufficiently diluted, as we suggest here \u0026ndash; i.e. plating them in serial dilution as a simple and necessary solution to extend frequency measurements for PBMC samples without an upper quantification limit (Note 29). When testing PBMC for B\u003csub\u003emem\u003c/sub\u003e-derived antigen-specific ASC, we recommend starting at 2 x 10\u003csup\u003e5\u003c/sup\u003e cells per well and progressing in a 1\u0026thinsp;+\u0026thinsp;1 dilution series (see Supplemental Fig.\u0026nbsp;5A). While SFU crowding may occur at the highest inputs of the cell titration for some test samples, in such cases the lower cell inputs will still follow a linear relationship between cell numbers plated and SFU counts. Using such a serial dilution approach also permits an accurate assessment of ASC frequency in the sample by averaging the frequencies calculated from each dilution point in the linear range (Supplemental Fig.\u0026nbsp;10) (Note 30).\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec9\" class=\"Section3\"\u003e \u003ch2\u003e2.4.2. Lower detection limit and lower limit of quantification.\u003c/h2\u003e \u003cp\u003eWith regard to interpreting antigen-specific B cell ImmunoSpot test results, there are two basic questions to be answered. The first is qualitative: are there primed B\u003csub\u003emem\u003c/sub\u003e present in an individual? The second is quantitative: what is the precise frequency of B\u003csub\u003emem\u003c/sub\u003e-derived ASC within the PBMC test sample? Regarding the immunodiagnostic significance of the lower detection limit, it can be assumed that, if antigen-specific B\u003csub\u003emem\u003c/sub\u003e are present, even at very low numbers, this can have a major impact for the individual host (Note 8). As antigen-specific B (and T) cells, can occur at low frequencies in antigen-primed individuals, often the aim is to lower the detection limit for antigen-specific ASC as much as possible.\u003c/p\u003e \u003cp\u003eDespite not yet having studied this issue in depth, our experience gained so far indicates that if a single ASC producing antigen-specific IgG is plated, that this ASC will be reliably detected on the basis of its secretory footprint. Therefore, while the lower limit of quantification will depend on the number of PBMC assessed, and is thus specific for a particular assay protocol, there is no inherent lower limit of detection for such tests. If, for example, 10\u003csup\u003e6\u003c/sup\u003e PBMC are seeded per well into 100 replicate wells, the detection limit can be extended to be, in this case, 1 in 10\u003csup\u003e8\u003c/sup\u003e PBMC, provided there is no background noise.\u003c/p\u003e \u003cp\u003eThe general rule in the T cell field for detecting weak antigen-specific responses is that the mean number of antigen-specific SFU (established in 3\u0026ndash;4 replicate wells at a single cell input) should be more than 1.65-fold the standard deviation of the SFU count in the control wells (established in 3\u0026ndash;4 replicate wells at the same single cell input). As B cells are the only cell type capable of producing antibody, in antigen-specific B cell assays every spot counts. In future studies aiming to extend the lower detection threshold, it should be kept in mind that (unlike for T cell assays), in B cell assays, the Poisson distribution applies when analyzing low frequency ASC events (Supplemental Figs.\u0026nbsp;11 and 12). As to the lower limit of quantification for B cell ImmunoSpot assays in general, Poisson rules also apply (Supplemental Figs.\u0026nbsp;11 and 12). Here too, increasing the number of PBMC plated per well, along with the number of replicate wells, will increase the accuracy of frequencies determined in the very low frequency range.\u003c/p\u003e \u003cp\u003eAs frequencies of antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived ASC span a wide range (Supplemental Fig.\u0026nbsp;9 and [\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e, \u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e], it is recommended to test the PBMC first in a serial dilution, starting at 2 x 10\u003csup\u003e5\u003c/sup\u003e per well (Supplemental Fig.\u0026nbsp;5A); or, if the frequencies are anticipated to be lower, we recommend to start the serial dilution at 1 x 10\u003csup\u003e6\u003c/sup\u003e PBMC per well (cell material permitting) (Note 31). Should samples be outside of the range covered by this first approach and if extending the lower limit of detection is necessary for such samples, additional aliquots can be thawed (Note 32) in which the aforementioned testing of replicate wells with high cell numbers is applied to extend the lower limit of detection/qualification.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec10\" class=\"Section3\"\u003e \u003ch2\u003e2.4.3. Interpreting B\u003csub\u003emem\u003c/sub\u003e presence and frequencies\u003c/h2\u003e \u003cp\u003eAs a first approximation, therefore, one could expect the frequency of B\u003csub\u003emem\u003c/sub\u003e to be proportional to the magnitude of secondary antibody responses that these cells will generate upon antigen reencounter (Note 33). Similarly, even if an individual has not been exposed to a specific antigen (e.g., a new virus variant that emerges, a so-called heterotypic virus) but possesses cross-reactive B\u003csub\u003emem\u003c/sub\u003e (e.g., induced by the original homotypic virus), such B\u003csub\u003emem\u003c/sub\u003e can be expected to convey an elevated level of immune protection through their ability to rapidly differentiate into ASC and raise the level of specific antibody. Confirming this notion, lower B\u003csub\u003emem\u003c/sub\u003e frequencies may correlate with the risk for vaccine breakthrough infection caused by the SARS-CoV-2 variants. Therefore, detecting any number of antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived ASC (as identified by their production of class-switched antibodies), whether primed by the nominal antigen or a cross-reactive antigen, should be of immune diagnostic significance (Note 34). Refer to [\u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e] for measurements of B\u003csub\u003emem\u003c/sub\u003e cross-reactivity at single-cell resolution using the B cell ImmunoSpot approach, and to an in-depth description of pre-formed antibody (the \u0026ldquo;first wall of B cell defense\u0026rdquo;) and B\u003csub\u003emem\u003c/sub\u003e-mediated immunity (the \u0026ldquo;second wall of B cell defense\u0026rdquo;) as it relates to homo- vs. heterotypic immune defense [\u003cspan citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e].\u003c/p\u003e \u003c/div\u003e \u003c/div\u003e \u003cdiv id=\"Sec11\" class=\"Section2\"\u003e \u003ch2\u003e2.5. Accurate detection of Ig class\u003c/h2\u003e \u003cp\u003eIn addition to establishing the mere number of B\u003csub\u003emem\u003c/sub\u003e present in the body, which reveals the existence and magnitude of immunological memory, it is also essential to define the Ig class (and/or subclass) these B\u003csub\u003emem\u003c/sub\u003e will produce upon antigen encounter or reencounter. This is because immunoglobins of different Ig classes (and subclasses) mediate fundamentally different defense reactions, primarily due to their differential binding to Fc receptors and complement-activating properties (Note 35).\u003c/p\u003e \u003cp\u003eUpon antigen (re-)encounter, and subsequent re-activation, B\u003csub\u003emem\u003c/sub\u003e can rapidly differentiate into PC that secrete the same Ig class/subclass expressed by the parental B\u003csub\u003emem\u003c/sub\u003e. Therefore, detecting the Ig class that B\u003csub\u003emem\u003c/sub\u003e-derived ASC produce in ImmunoSpot assays permits the specific type(s) of antibody that will be produced following the next antigen encounter to be predicted. Knowledge of the full spectrum of Ig classes that the antigen-specific B\u003csub\u003emem\u003c/sub\u003e repertoire will produce is essential for predicting the protective efficacy of future antibody responses to a \u0026ldquo;specific\u0026rdquo; antigen. Moreover, such B cell ImmunoSpot assays may also predict the likelihood of antibody-mediated complications occurring upon antigen re-exposure (e.g., causing allergic reactions or antibody-dependent enhancement leading to exacerbation of clinical disease [\u003cspan citationid=\"CR39\" class=\"CitationRef\"\u003e39\u003c/span\u003e]. Importantly, the frequencies of antigen-specific B\u003csub\u003emem\u003c/sub\u003e capable of secreting different Ig classes differ by orders of magnitude [\u003cspan citationid=\"CR16\" class=\"CitationRef\"\u003e16\u003c/span\u003e, \u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e]. Thus, it is not only recommended to assess all antigen-specific Ig classes, but also to do so over a wide frequency range for each. The latter can readily be accomplished by combining the serial dilution strategy with 4-color ImmunoSpot analysis [\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e] (Supplemental Figs.\u0026nbsp;5 and 13).\u003c/p\u003e \u003cdiv id=\"Sec12\" class=\"Section3\"\u003e \u003ch2\u003e2.5.1 Four-color B cell ImmunoSpot analysis\u003c/h2\u003e \u003cp\u003eIndividual B cells can only express a single Ig class/subclass [\u003cspan citationid=\"CR41\" class=\"CitationRef\"\u003e41\u003c/span\u003e]. Therefore (unlike T cell ImmunoSpot analysis), standard multi-color B cell ImmunoSpot analysis does not need to account for the co-expression of the different analytes (Ig classes or subclasses) studied. This basic biologic fact greatly facilitates objective identification of secretory footprints in multiplexed B cell assays, provided that the fluorochromes used only yield a signal in the corresponding detection plane and do not cross-bleed into the others (Supplemental Fig.\u0026nbsp;13 and Note 36). Such fluorochromes, which possess non-overlapping spectra, are used in CTL\u0026rsquo;s multi-color detection systems [\u003cspan citationid=\"CR42\" class=\"CitationRef\"\u003e42\u003c/span\u003e]. Of note, the sensitivity of the enzymatic (single- or double-color) ELISPOT and of the (up to four-color) FluoroSpot modalities for quantifying individual B cell-derived Ig secretory footprints are similar [\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e], see also Supplemental Fig.\u0026nbsp;14, and Note 37). For the comprehensive assessment of the antigen-specific B cell repertoire, we recommend performing a four-color assay to determine the major classes of secreted Ig (MAGE), and, in parallel, a four-color assay measuring individual IgG subclasses if cell material and coating antigen(s) are not limiting.\u003c/p\u003e \u003c/div\u003e \u003c/div\u003e \u003cdiv id=\"Sec13\" class=\"Section2\"\u003e \u003ch2\u003e2.6. Optimization of PBMC utilization\u003c/h2\u003e \u003cp\u003eThe volume of blood available for cellular immune monitoring is often the limiting factor in clinical trials, particularly when it comes to obtaining PBMC from children and critically ill patients. Thus, devising the most efficient PBMC utilization protocols primarily defined our approach for comprehensive assessment of the antigen-specific B cell repertoire. Conventionally, cellular assays, including T cell ImmunoSpot tests, are performed using replicates, typically 3\u0026ndash;4 replicate wells per test condition, from which means and standard deviations (SD) are established with the required level of precision. In the T cell assay, to become activated, very rare antigen-specific T cells must interact with antigen-presenting cells within the PBMC monolayer on the well bottom, triggering antigen-induced cytokine production. In contrast, in B cell ImmunoSpot tests, individual ASC are detected that are already producing Ig \u0026ldquo;spontaneously\u0026rdquo;, in a cell autonomous manner (no matter whether these B cells became activated \u003cem\u003ein vivo\u003c/em\u003e, or whether resting B\u003csub\u003emem\u003c/sub\u003e were subjected to \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation prior to testing in a B cell ImmunoSpot assay).\u003c/p\u003e \u003cp\u003eBecause pre-activated B cells do not require cell-cell contacts for secreting antibodies, the PBMC test samples can be diluted much further than in T cell assays (that strictly depend on T cell and antigen-presenting cell contacts) to obtain optimal (20\u0026ndash;100) SFU counts. For frequency calculations, it is plausible that testing PBMC in serial dilution will provide similarly accurate ASC frequency measurements when done with a single well per cell input by calculating the frequency by averaging the results from several dilution points compared to establishing frequencies from the mean of replicate wells at each cell input. Extensive comparisons confirmed this assumption (Supplemental Fig.\u0026nbsp;15). Testing PBMC in single well serial dilutions for the initial frequency assessment in yet uncharacterized samples, therefore, allows the investigator to reduce the number of cells needed to 4.4 x 10\u003csup\u003e5\u003c/sup\u003e (with safety margin 5 x 10\u003csup\u003e5\u003c/sup\u003e) cells per antigen (when the serial dilution is started at 2 x 10\u003csup\u003e5\u003c/sup\u003e PBMC per well in a four-color IgM, IgA, IgG and IgE detection test). An illustration of a recommended well layout for such a B cell ImmunoSpot test is provided in Supplemental Fig.\u0026nbsp;5A. Note 38 provides suggestions for how to set up such serial dilutions in a streamlined manner. PBMC can be cryopreserved while maintaining full B cell functionality [\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e], with 80\u0026ndash;90% of the cells typically recovered after thawing. If the PBMC are to be tested for B\u003csub\u003emem\u003c/sub\u003e-derived ASC reactivity after \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation, up to 50% cell loss can be expected (Supplemental Fig.\u0026nbsp;2H). Therefore, when working with cryopreserved cell material to detect B\u003csub\u003emem\u003c/sub\u003e-derived ASC after 5 days of \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation (or plasmablasts directly \u003cem\u003eex vivo\u003c/em\u003e), cryopreserving cells at 1\u0026ndash;2 x 10\u003csup\u003e6\u003c/sup\u003e PBMC per aliquot is minimally recommended per antigen (Note 38) \u0026ndash; ideally, several such aliquots. The first aliquot will suffice for assessing the frequency of B\u003csub\u003emem\u003c/sub\u003e-derived antigen-specific ASC producing one of the four Ig classes, including defining the overall numbers of ASC producing these Ig classes irrespective of their antigen specificity. Additional aliquots may be used for extending the lower detection limits, if that would be needed. Alternatively, affinity- [\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e] or cross-reactivity [\u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e] assessments of the antigen-specific ASC repertoire could be performed using the remaining cell material, if desired. It should also be noted here that ASC survive the ImmunoSpot testing unharmed, and instead of discarding them at the end of the ImmunoSpot assay, they can be utilized for additional functional or genetic analyses.\u003c/p\u003e \u003c/div\u003e"},{"header":"3.0. Validation of B cell ImmunoSpot Tests","content":"\u003cp\u003eAccording to the accepted definition, method validation is an evaluation process of the performance characteristics of an established analytical procedure through laboratory studies with all performance characteristics meeting the requirements of the intended analytical applications. In other words, an analytical method should be examined from a variety of aspects to prove that the test results can be trusted and appropriately applied to the intended quality objective.\u003c/p\u003e \u003cp\u003eFollowing the guidelines for T cell ImmunoSpot assay validation [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e, \u003cspan citationid=\"CR27\" class=\"CitationRef\"\u003e27\u003c/span\u003e], modified to accommodate the divergent features of B cell assays described above, we determined the (1) Specificity, (2) Accuracy, (3) Precision, (4) Detection Limits, (5) Qualification Limits, and (6) Linearity of our SARS-CoV-2 S-antigen-specific, 4-color Ig class (IgM/IgA/IgG/IgE, \u0026ldquo;MAGE\u0026rdquo;) B cell ImmunoSpot assay using the serial dilution variant. As B cell ImmunoSpot assays lend themselves to high throughput testing (Notes 38\u0026ndash;43), in the following we will recommend a workflow and experimental design that permits the extraction of all the raw data needed for a full validation of the antigen-specific B cell ImmunoSpot test by performing only three relatively simple tests, requiring in total 2.2x10\u003csup\u003e7\u003c/sup\u003e PBMC; as outlined in Note 42 (see also Note 43).\u003c/p\u003e \u003cdiv id=\"Sec15\" class=\"Section2\"\u003e \u003ch2\u003e3.1. Specificity\u003c/h2\u003e \u003cdiv id=\"Sec16\" class=\"Section3\"\u003e \u003ch2\u003e3.1.1 Immunological specificity\u003c/h2\u003e \u003cp\u003eEstablishing antigen-specificity requires testing PBMC from negative control individuals (who have not been exposed yet to the antigen of interest) as compared to positive controls (those known to have been exposed). In the case of our example, the negative control tested the presence of B\u003csub\u003emem\u0026minus;\u003c/sub\u003ederived ASC with reactivity for the S-antigen (representing the prototype Wuhan-Hu-1 strain of SARS-CoV-2 virus) in PBMC collected prior to the onset of the COVID pandemic (pre-COVID era). This was compared with the results of testing PBMC from individuals with PCR-verified SARS-CoV-2 infection before vaccines became available. We also tested PBMC collected from individuals 6 months after receiving two doses of COVID-19 mRNA vaccine (that encoded the Wuhan-Hu-1 S-antigen) before infections with SARS-CoV-2 variants became widespread. The non-infected status of these latter donors was verified by testing for SARS-CoV-2 Nucleocapsid (NCAP) antigen reactivity. Supplemental Table\u0026nbsp;1 shows the frequencies of Wuhan S-antigen-reactive B\u003csub\u003emem\u003c/sub\u003e-derived ASC detected in these three cohorts. The data indicate that 100% of the vaccinated individuals and 100% of the subjects that recovered from PCR-verified SARS-CoV-2 infection, but none of the pre-COVID era samples, possessed B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC reactivity against the S-antigen at high or relatively high frequencies. Of note, the frequencies of pan IgG\u003csup\u003e+\u003c/sup\u003e (irrespective of antigen specificity) ASC measured in parallel were similar in the three cohorts, documenting that neither cryopreservation nor the duration of storage could account for the observed differences in S-antigen-specific IgG\u003csup\u003e+\u003c/sup\u003e ASC detected. In contrast, S-antigen \u0026ldquo;specific\u0026rdquo; IgM\u003csup\u003e+\u003c/sup\u003e ASC reactivity following polyclonal stimulation was detected in the positive and negative control cohorts alike (Supplemental Fig.\u0026nbsp;8B), implying broad reactivity and lack of specificity for \u003cem\u003ein vitro\u003c/em\u003e induced IgM\u003csup\u003e+\u003c/sup\u003e ASC.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec17\" class=\"Section3\"\u003e \u003ch2\u003e3.1.2. Diagnostic specificity\u003c/h2\u003e \u003cp\u003eThe data in Supplemental Table\u0026nbsp;1 also establish the 100% diagnostic specificity of this B cell ImmunoSpot test for identifying individuals that received a COVID-19 mRNA vaccine or developed B cell memory following infection. While it may be more the exception than the rule, the S-antigen example we have selected here perfectly illustrates the immunological and diagnostic specificity of the IgG\u003csup\u003e+\u003c/sup\u003e B cell ImmunoSpot approach. Notably, in spite of some sequence conservation between the S-antigen encoded by SARS-CoV-2 and other coronaviruses causing common colds, we failed to detect B\u003csub\u003emem\u003c/sub\u003e-derived ASC reactivity against the S-antigen of SARS-CoV-2 in any of the pre-COVID era samples. In contrast, B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC reactivity against recombinant hemagglutinin (rHA) antigens representing seasonal influenza vaccine strains were clearly detectable in these same assays in all cohorts (data not shown).\u003c/p\u003e \u003cp\u003eFast forwarding to the present, because most individuals have since either received multiple COVID-19 vaccinations and/or have been infected with one or more variant SARS-CoV-2 viruses, identifying an individual that is immunologically na\u0026iuml;ve to the prototype Wuhan-Hu-1 S-antigen has become quite rare in the population (Kirchenbaum, manuscript in preparation). As such, B\u003csub\u003emem\u003c/sub\u003e-derived ASC reactivity against the S-antigen can potentially serve as a universal positive control for B cell ImmunoSpot testing, alongside influenza antigens, and probably many other antigens that originate from other viruses causing ubiquitous infections.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec18\" class=\"Section3\"\u003e \u003ch2\u003e3.1.3. Immunological interpretation of B\u003csub\u003emem\u003c/sub\u003e or plasmablast specificity\u003c/h2\u003e \u003cp\u003eThe clarity of the data shown in Supplemental Table\u0026nbsp;1 (i.e., none of the SARS-CoV-2-na\u0026iuml;ve, but all the convalescent or vaccinated individuals display vigorous S-antigen-specific B cell memory) would imply a tremendous potential for B\u003csub\u003emem\u003c/sub\u003e monitoring in immunodiagnostics. But to what extent are these findings likely to apply to antigens other than S-antigen of the prototype Wuhan-Hu-1 strain, where a clearly na\u0026iuml;ve vs. exposed state can be defined? And even when it comes to the S-antigen, does the marked difference seen between the na\u0026iuml;ve and antigen-primed state hold up for later time points when B cell memory has established itself, for example when desiring to monitor the impact of booster vaccinations? While these are the most fundamental questions for the immunodiagnostic interpretation of B cell ImmunoSpot results, the answers are still awaited. However, the observations we have already made anticipate some of these answers, as discussed in the following.\u003c/p\u003e \u003cp\u003eBetter understanding of B cell cross-reactivity \u003cem\u003ein vivo\u003c/em\u003e, including affinity cut-offs, will be an issue. The B cell system has evolved to achieve remarkable specificity for the selective recognition of any given antigen. This is mediated through the enormous clonal diversity present in the na\u0026iuml;ve B cell repertoire which encodes\u0026thinsp;~\u0026thinsp;10\u003csup\u003e12\u003c/sup\u003e BCR from which a small number of cells endowed with BCR specific for the antigen of interest (and with a sufficient affinity to be activated) are recruited into an immune response. Subsequently, the antigen-specificity of the B cell response is further improved by somatic hypermutation of the BCR expressed by the positively selected B cells participating in the germinal center reaction, which is then followed by further rounds of hypermutation and positive selection of the subclones which express BCR with the highest affinity for the antigen (a process termed \u0026ldquo;affinity maturation\u0026rdquo;) [\u003cspan citationid=\"CR44\" class=\"CitationRef\"\u003e44\u003c/span\u003e]. While such highly specific B cells can immediately contribute to immune defense by differentiating into ASC and rapidly increasing the abundance of specific antibody (constituting the so-called \u0026ldquo;first wall\u0026rdquo; of B cell-mediated immunity [\u003cspan citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e], we also need to keep in mind that the B cell system is adaptive and has evolved the ability to confer cross-reactive protection against antigenically-related pathogens in order to provide increased responsiveness to variant viruses (the so-called \u0026ldquo;second wall\u0026rdquo; of B cell-mediated immunity [\u003cspan citationid=\"CR23\" class=\"CitationRef\"\u003e23\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eFor example, as discussed above, we did not detect B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC with reactivity against the SARS-CoV-2 S-antigen in pre-COVID era PBMC samples (Supplemental Table\u0026nbsp;1), despite the fact that most likely everyone has been infected with related coronaviruses responsible for causing common colds [\u003cspan citationid=\"CR45\" class=\"CitationRef\"\u003e45\u003c/span\u003e], and therefore could be expected to possess cross-reactive B\u003csub\u003emem\u003c/sub\u003e. However, we found that ~\u0026thinsp;40% of B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC with reactivity against the receptor binding domain (RBD) of the S-antigen expressed by the prototype Wuhan-Hu-1 strain, elicited by infection early in the COVID pandemic, cross-reacted with the RBD probe representing the BA.1 Omicron variant [\u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e]. Such PBMC samples were collected long before the emergence of the Omicron variant, which caused widespread infections, so this finding implies that some S-antigen epitopes targeted by such \u0026ldquo;cross-reactive\u0026rdquo; ASC remained conserved on the variant (BA.1) strain. Studies of pre-Omicron and post-Omicron PBMC using the BA.1 RBD probe are therefore not likely to provide the same clear-cut discrimination between Omicron-na\u0026iuml;ve and Omicron-exposed individuals due to the pre-existence of such cross-reactive B\u003csub\u003emem\u003c/sub\u003e. Importantly, however, these pre-existing cross-reactive B\u003csub\u003emem\u003c/sub\u003e also were capable of contributing to protective responses, as evidenced by reduced disease severity in cases of breakthrough Omicron infection. Therefore, while blurring the diagnostic specificity of comparisons between PBMC samples collected before or after emergence of SARS-CoV-2 variants of concern, the detection of cross-reactive B\u003csub\u003emem\u003c/sub\u003e-derived ASC still provides valuable immune diagnostic information on the pre-existence of a primed, clonally expanded and IgG class-switched B\u003csub\u003emem\u003c/sub\u003e repertoire reactive with the antigen being studied. What percentages of such preexisting, cross-reactive B\u003csub\u003emem\u003c/sub\u003e are recruited into such a (secondary) B cell response, including to what extent they undergo further somatic mutation and affinity maturation, and clonal expansions, remains an open question.\u003c/p\u003e \u003cp\u003eAdditionally, to what extent increases of B\u003csub\u003emem\u003c/sub\u003e frequencies reveal renewed antigen exposures is also an open question. In our preliminary studies on this issue, we found evidence for clonal expansions after each COVID-19 mRNA vaccination. In paired PBMC samples collected prior to and 14 days following the first COVID-19 mRNA vaccination, frequencies of S-antigen-reactive B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC went from undetectably low to an average of 20 IgG\u003csup\u003e+\u003c/sup\u003e ASC per 10\u003csup\u003e6\u003c/sup\u003e PBMC (Supplemental Fig.\u0026nbsp;8A). In a separate cohort, paired PBMC collected\u0026thinsp;~\u0026thinsp;1 month following the second and third COVID-19 mRNA vaccinations also evidenced an increase in the frequency of S-antigen-reactive B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC following each COVID-19 mRNA vaccination. Following the second COVID-19 mRNA vaccination the average frequency of S-antigen-reactive B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC was ~\u0026thinsp;527 IgG\u003csup\u003e+\u003c/sup\u003e ASC per 10\u003csup\u003e6\u003c/sup\u003e PBMC and it increased to ~\u0026thinsp;3822 IgG\u003csup\u003e+\u003c/sup\u003e ASC per 10\u003csup\u003e6\u003c/sup\u003e PBMC following the third dose (~\u0026thinsp;7.5-fold increase). Detailed assessment of PBMC samples collected following additional COVID-19 mRNA vaccinations and/or breakthrough infection with SARS-CoV-2 variants is ongoing in our group and seeks to define whether S-antigen-reactive B\u003csub\u003emem\u003c/sub\u003e-derived ASC frequencies plateau after repeated antigen encounters. Therefore, increases in B\u003csub\u003emem\u003c/sub\u003e-derived ASC frequencies may no longer be a reliable marker for diagnosing new antigen encounters once the memory B cell repertoire has been established.\u003c/p\u003e \u003cp\u003eWhen frequency increases do not reveal antigen exposures, what other measures could be applied to better understand whether a new wave of B cell responses has been initiated, and whether this may have medical implications? For example, this is highly relevant to the important question of whether there is a benefit from repeated booster vaccinations, or is this merely a misinterpretation of Burnett\u0026rsquo;s clonal selection theory? While the answer to this question is still unknown, we can make some predictions, as follows.\u003c/p\u003e \u003cp\u003eWe must keep in mind that not all antigen-specific B\u003csub\u003emem\u003c/sub\u003e are equal, even if they produce the same IgG class/subclass. Specifically, for example, owing to differences in the affinity of secreted antibody, a one million times higher concentration of low affinity (K\u003csub\u003eD\u003c/sub\u003e= 10\u003csup\u003e\u0026minus;\u0026thinsp;5\u003c/sup\u003e) antibody would be required to achieve the same degree of antigen binding as a high affinity (K\u003csub\u003eD\u003c/sub\u003e=10\u003csup\u003e\u0026minus;\u0026thinsp;11\u003c/sup\u003e) antibody (Note 23 \u0026amp; 24). Moreover, it is known that affinity maturation is reengaged with each repeated antigen encounter [\u003cspan citationid=\"CR44\" class=\"CitationRef\"\u003e44\u003c/span\u003e]. Therefore, studying changes within the affinity distribution of the antigen-specific B\u003csub\u003emem\u003c/sub\u003e repertoire (that also can readily be measured by B cell ImmunoSpot [\u003cspan citationid=\"CR24\" class=\"CitationRef\"\u003e24\u003c/span\u003e]) might shed light on the beneficial effects of booster vaccinations when mere frequency increases do not provide conclusive information.\u003c/p\u003e \u003cp\u003eStudying the appearance of spontaneously Ig-secreting antigen-specific plasmablasts, which appear in the blood shortly after the (re-)engagement of an immune response, may also hold great immunodiagnostic potential when simply measuring frequency increases of antigen-specific B\u003csub\u003emem\u003c/sub\u003e no longer provides adequate resolution for detecting the induction of an immune response. Shortly following an antigen encounter, e.g. after SARS-CoV-2 mRNA vaccination, descendants of antigen-specific B cells that were engaged in the immune response appear in the blood (Supplemental Fig.\u0026nbsp;3C and D). Representing an alternative B cell fate than B\u003csub\u003emem\u003c/sub\u003e, such plasmablasts are in the process of migrating via the bloodstream to immunological niches, such as the bone marrow, where they may take up residence and become long-lived plasma cells that contribute to maintaining antibody titers long-term. Similar to B\u003csub\u003emem\u003c/sub\u003e, plasmablasts can also be cryopreserved while retaining their full functional activity [\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e]. Importantly, plasmablasts in blood can be detected using the same direct B cell ImmunoSpot approach as described here for B\u003csub\u003emem\u003c/sub\u003e-derived ASC, but without the need for prior \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation, by simply plating the PBMC as isolated (or after the thawing of a cryopreserved sample).\u003c/p\u003e \u003cp\u003eA fascinating, but still completely underdeveloped field is the study of the B\u003csub\u003emem\u003c/sub\u003e specific for autoantigens (including tumor-associated antigens). The following fundamental questions will need to be answered before the field of B (or T) cell immune diagnostics can progress with autoimmune diseases or cancers. In healthy individuals, and if so, to what extent, does the presence of the autoantigen (and which of the diverse autoantigens present on the target cells of interest) result in the spontaneous priming of autoantigen-specific B\u003csub\u003emem\u003c/sub\u003e, and lead to their activation, deletion or induction of unresponsiveness? What is the situation with those tumor-associated antigens that are in fact overexpressed autoantigens? As autoantibodies specific for such autoantigens can be frequently detected in healthy individuals [\u003cspan citationid=\"CR46\" class=\"CitationRef\"\u003e46\u003c/span\u003e], it might not come as a surprise if B\u003csub\u003emem\u003c/sub\u003e will also be detected. How does this autoantigen-specific B\u003csub\u003emem\u003c/sub\u003e repertoire change during an exacerbation of the autoimmune response in an autoimmune disease and/or cancer? Will studies of the resting B\u003csub\u003emem\u003c/sub\u003e repertoire, or that of plasmablasts provide more insights into the underlying autoimmune responses? Owing to their exquisite sensitivity, if properly developed and validated, B cell ImmunoSpot assays are presently best positioned to provide answers to these fundamental questions. In these settings, however, a simple comparison of autoantigen/tumor associated antigen-reactive B\u003csub\u003emem\u003c/sub\u003e frequencies between a \u0026ldquo;healthy\u0026rdquo; cohort vs. patients with the \u0026ldquo;autoimmune disease/cancer\u0026rdquo; may not always provide the expected diagnostic specificity information (primarily, if B\u003csub\u003emem\u003c/sub\u003e are present in healthy donors), even if the antigen-specificity of the B cell ImmunoSpot test system is exquisite.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec19\" class=\"Section3\"\u003e \u003ch2\u003e3.1.4. Traditional definition of specificity in terms used by regulatory bodies\u003c/h2\u003e \u003cp\u003eIn bioanalysis, specificity refers to the ability to detect an analyte in the presence of potentially interfering substances. In the context of B cell ImmunoSpot assays, this interpretation of specificity translates into assessing whether the reliable detection of individual antigen-specific ASC in PBMC is compromised by other components present in the test sample. This could be due to absorption of antibodies by bystander cells, for example, or through restricted access to the antigen-coated membrane and lack of secretory footprint formation when large numbers of cells are plated in the assay well.\u003c/p\u003e \u003cp\u003eTo test the hypothesis that such interference might occur, we evaluated PBMC containing S-antigen-specific, B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC following polyclonal stimulation with or without the addition of autologous non-stimulated PBMC from the same blood draw (while the latter contain S-antigen-specific B\u003csub\u003emem\u003c/sub\u003e, these cells are not actively secreting antibody). The results are shown in Supplemental Table\u0026nbsp;2, revealing negligible interference following addition of high numbers (5 x 10\u003csup\u003e5\u003c/sup\u003e) of resting autologous PBMC.\u003c/p\u003e \u003cp\u003eAs resting PBMC (that do not contain spontaneous ASC) were used in the above experiment, we also tested whether the addition of polyclonally activated PBMC (that contained an abundance of ASC but which lack specificity for the S-antigen) would interfere with the test results. To be able to do so, we needed to select donors for whom we had pre-COVID era PBMC cryopreserved (as the latter do not contain S-antigen-specific ASC); the addition of such autologous polyclonally stimulated pre-COVID PBMC to PBMC collected following COVID-19 mRNA vaccination resulted in an increased number of pan IgG\u003csup\u003e+\u003c/sup\u003e ASC. However, the number of S-antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC measured in the assay was not altered (Notes 45\u0026ndash;47). The results shown in Supplemental Fig.\u0026nbsp;16 suggest that increasing the number of third-party antigen-specific ASC in the test sample does not interfere with the detection of antigen-specific ASC.\u003c/p\u003e \u003c/div\u003e \u003c/div\u003e \u003cdiv id=\"Sec20\" class=\"Section2\"\u003e \u003ch2\u003e3.2. Accuracy\u003c/h2\u003e \u003cp\u003eAccuracy is defined as closeness of agreement to a verifiably true value. For antigen-specific ImmunoSpot assays the true value that the assay aims to reveal is the number/frequency of antigen-specific, functional B or T cells in a test sample (Note 48). However, ImmunoSpot assay accuracy cannot be determined due to the lack of a reference standard or an alternative test that could provide an exact measurement of functional antigen-specific B or T cells in a given sample (except highly developed ImmunoSpot measurements, themselves). However, evaluating B cell hybridomas in such B cell ImmunoSpot tests, as shown in Supplemental Fig.\u0026nbsp;4, comes close to this requirement. For validated T cell ImmunoSpot assays, therefore, the emphasis has shifted towards obtaining data on the accuracy of a laboratory\u0026rsquo;s performance by participation in proficiency panels that yield information on a laboratory\u0026rsquo;s performance relative to the other laboratories testing the same reference samples (Note 49). For B cell ImmunoSpot assays, such proficiency panels do not exist yet.\u003c/p\u003e \u003cp\u003eWhile the proficiency panel approach is certainly a work-around to the intended accuracy mandate, it is, for obvious reasons, a rather questionable one. As such proficiency panels neither require, nor encourage, the participating laboratories to harmonize through adopting standardized (best performing) protocols, reagents, or instruments, the participants, randomly utilizing a wide variety of such approaches, are likely to underperform on average. At the same time, the average itself sets the acceptance criterion for passing the accuracy assessment, which can even cause the better performing laboratories to fail (Note 50). The authors of the present communication strongly believe that expert laboratories, i.e. those that have committed extensive effort to developing in-depth expertise refining such assays, should set the standard for the performance of participating laboratories providing pre-characterized reference PBMC so other laboratories can verify their proficiency by reproducing the pre-established test results.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec21\" class=\"Section2\"\u003e \u003ch2\u003e3.3. Precision\u003c/h2\u003e \u003cp\u003ePrecision in validation is defined as determining the variability of the assay results. Precision testing has to evaluate intra-assay and inter-assay, including inter-operator, and day-to-day, variability.\u003c/p\u003e \u003cdiv id=\"Sec22\" class=\"Section3\"\u003e \u003ch2\u003e3.3.1 Intra-assay precision\u003c/h2\u003e \u003cp\u003eIntra-assay precision in regulatory language is also called \u0026ldquo;repeatability\u0026rdquo;. In T cell ImmunoSpot assays, it is measured by testing three replicates of the same PBMC sample in the same plate, whereby the PBMC samples from different donors are plated at a fixed \u0026ldquo;ideal\u0026rdquo; cell number per well that best measures a range of antigen-specific T cell frequencies (Note 51) [[\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e]. This approach is valid for B cell ImmunoSpot assays only if the PBMC are seeded in numbers such that the frequencies of antigen-specific SFU are \u0026lt;\u0026thinsp;100 per well (or pan Ig SFU are \u0026lt;\u0026thinsp;300 per well), that is, before spot crowding and ELISA effects interfere with accurate SFU counting (see above, and Supplemental Figs.\u0026nbsp;4 and 10). Owing to the highly variable frequency of antigen-specific B cells in different individuals\u0026rsquo; PBMC, there are two solutions for establishing intra-assay precision. If the numbers of antigen-specific ASC are still unknown for the samples, testing PBMC at serial dilutions with 3\u0026ndash;4 replicate wells for each dilution step (starting e.g. at 3 x 10\u003csup\u003e5\u003c/sup\u003e PBMC per well, and progressing in a 1\u0026thinsp;+\u0026thinsp;1 dilution series) may suffice. In this case, the replicate wells containing\u0026thinsp;\u0026lt;\u0026thinsp;100 SFU and \u0026gt;\u0026thinsp;20 SFU should be compared. Wells within this SFU count range provide the most accurate information on intra-assay precision, whereas lower spot counts exhibit increased variation due to the onset of Poisson noise (Supplemental Figs.\u0026nbsp;11 \u0026amp; 12). Results for such a S-antigen-specific ImmunoSpot test are shown in Supplemental Table\u0026nbsp;3.\u003c/p\u003e \u003cp\u003eIf the frequencies of antigen-specific ASC have already been pre-established for the PBMC samples, the cells can be seeded in replicates at a single cell concentration, in numbers that are expected to produce\u0026thinsp;~\u0026thinsp;50\u0026ndash;75 ASC per well. Fewer PBMC are needed for this second variant of intra-assay precision testing.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec23\" class=\"Section3\"\u003e \u003ch2\u003e3.3.2. Inter-assay precision\u003c/h2\u003e \u003cp\u003eInter-assay precision is also designated \u0026ldquo;intermediate precision\u0026rdquo;, or \u0026ldquo;plate-to-plate variability\u0026rdquo; in regulatory language. For T cell ImmunoSpot validation, it is typically established by testing two (or cells permitting, more) plates in parallel [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e], and this approach can also be adopted for B cell ImmunoSpot validation. However, as outlined above for assessing intra-assay variation, for the same reasons, PBMC have to be plated in serial dilution, and only the SFU counts in the upper linear range should be accepted.\u003c/p\u003e \u003cp\u003eFor establishing inter-assay precision, one approach is to seed pre-characterized PBMC in replicate wells at the fixed cell number that is expected to result in ~\u0026thinsp;50\u0026ndash;75 SFU per well. In this case, the coefficient of variation (CV) can be calculated for the corresponding wells. As a second option, frequency extrapolations for serially diluted PBMC for the two (or more) plates may be compared (Note 52). Results for the latter type of plate-to-plate variability testing are shown in Supplemental Table\u0026nbsp;4. For a suggestion on how to combine establishing the inter assay-precision with testing for day-to-day variability and specificity, see Note 42, and below.\u003c/p\u003e \u003cp\u003eBecause in the proposed inter-assay design the cells are tested in replicate wells in serial dilution, the results obtained will also permit the verification of the frequency calculations established from the means of the replicates vs. those obtained from individual wells (see Supplemental Fig.\u0026nbsp;15).\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec24\" class=\"Section3\"\u003e \u003ch2\u003e3.3.3. Inter-investigator precision\u003c/h2\u003e \u003cp\u003eInter-investigator precision is one criterion to establish Reproducibility. It requires that the same cell samples are tested by three different investigators in parallel (Note 53). PBMC are plated at serial dilutions and frequencies are established from the linear range of the results. Supplemental Table\u0026nbsp;5 shows inter-investigator precision data for S antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC measurements. For a suggestion on how to consolidate establishing the inter-investigator precision testing with testing for day-to-day variability and specificity, see Note 42, and below.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec25\" class=\"Section3\"\u003e \u003ch2\u003e3.3.4. Day-to-day variability\u003c/h2\u003e \u003cp\u003eDay-to-day (also called inter-assay) variability testing includes establishing the reproducibility of results obtained when the test is done on at least 3 different days by the same investigator(s). Without having to perform a separate series of tests involving extra cells, these data will be obtained as part of the 3 assay runs proposed in Note 42 for a streamlined validation effort, the only requirement being that at least one of the investigators tests the same PBMC samples (at least 3 of them) during the three occasions. Frequency extrapolations for each of the PBMC should be compared for the three independent tests.\u003c/p\u003e \u003cp\u003eOf note, the day-to-day variability in such a B cell ImmunoSpot assay is expected to be substantially higher than for all the other variability tests due to the inclusion of additional variables before the actual assay is performed. These include possible variability among individual aliquots of cryopreserved PBMC, any day-to-day differences in the thawing and washing process, the subsequent cell counting for polyclonal B cell stimulation cultures, the culture conditions themselves, and the ensuing washing steps and counting of the polyclonally stimulated cells for adjusting their concentration prior to plating -- all these variables and more can contribute to the degree of day-to-day reproducibility of the result. Despite all these possible sources of variability, and despite the fact that these tests have been performed in an R\u0026amp;D setting, in our hands, antigen-specific B cell ImmunoSpot assays yield data within \u0026lt;\u0026thinsp;20% CV (Supplemental Table\u0026nbsp;6). In the example shown here, the frequency of S-antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived IgG\u003csup\u003e+\u003c/sup\u003e ASC was established as the percentage of pan IgG\u003csup\u003e+\u003c/sup\u003e ASC present in each sample. With maximally 23% CV, the day-to-day variability was much lower than the 50% acceptability for cellular assays [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e].\u003c/p\u003e \u003c/div\u003e \u003c/div\u003e"},{"header":"4.0. Detection Limits","content":"\u003cdiv id=\"Sec27\" class=\"Section2\"\u003e \u003ch2\u003e4.1. Limit of blank\u003c/h2\u003e \u003cp\u003eIn analogy to T cell ImmunoSpot tests [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e], and also applicable for B cell ImmunoSpot assays, the limit of blank (LOB) is determined by evaluating wells that are treated identically to actual test wells but which were not seeded with PBMC (i.e., the membrane is coated with the antigen, but instead of PBMC, culture medium is added for the same culture period, then the Ig class-detecting antibodies are added, and visualized with the corresponding detection reagents (see Supplemental Fig.\u0026nbsp;1). Two wells per PBMC sample are reserved in the serial dilution series for the LOB (Supplemental Fig.\u0026nbsp;5A). As typically a multitude of PBMC samples are tested in B cell ImmunoSpot assays, the number of LOB wells will add up to a significant number. By definition, the LOB must be zero. If it is not, aggregated reagents are likely the cause of background noise. This can be remedied by filtering the reagents, or better, by subjecting the detection reagents to high-speed centrifugation (Note 54). Also, the recommended back-to-front final washing step helps to eliminate non-specific retention of reagents on the membrane (Note 55).\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec28\" class=\"Section2\"\u003e \u003ch2\u003e4.2. Lower limit of detection\u003c/h2\u003e \u003cp\u003eIn T cell ImmunoSpot assays, the lower limit of detection (LOD) is generally set at 1.6 (conservatively 2\u0026ndash;3)-fold the median SFU count for the background wells for each PBMC sample tested in replicate (in that case, the number of cytokine-producing cells present in the well detected if PBMC are plated in the absence of antigen). In the case of T cell assays, such a definition is appropriate because cells of the innate immune system can also secrete the measured cytokine and generate background \u0026ldquo;noise\u0026rdquo; above which the antigen-induced cytokine production by antigen-specific T cells needs to be detected as the specific signal. This definition cannot be applied to B cell ImmunoSpot assays, however, because only B cells produce antibody. While B cell ImmunoSpot assays can detect a single SFU in a cell input of up to 1 x 10\u003csup\u003e6\u003c/sup\u003e, this only indicates a secretory footprint was generated. Without putting an equal number of cells in an alternatively coated well for comparison, this one single spot is evidence of \"reactivity\" but is not necessarily \"specific\" for the coated antigen of interest. B cell assays \u0026ndash; in theory at least -- need to account for \"chance\" recognition of elements coated on the plate (antigen itself, but also potentially the anti-affinity tag capture reagent, an affinity tag if present on the antigen of interest, any components of the assay medium that could absorb to the assay membrane, and any antigens (secreted IgG included) present in the PBMC that could absorb to the membrane during the assay incubation). When frequencies of antigen-specific ASC are relatively high, such negative controls will be less necessary (and the LOB serves its function). However, when studying very rare events using high cell inputs (\u0026gt;\u0026thinsp;5 x 10\u003csup\u003e5\u003c/sup\u003e PBMC per well) specificity controls are needed to dissect antigen-specific SFU from such background \"noise\" (which is typically donor intrinsic). In our experience gained so far, such \u0026ldquo;background noise\u0026rdquo; was either entirely absent in most samples, or, when present, was often\u0026thinsp;\u0026lt;\u0026thinsp;2 SFU per 2 x 10\u003csup\u003e5\u003c/sup\u003e PBMC. Therefore, while further lowering the LOD is one area of ongoing investigation in our group, we presently believe, without extensive additional controls being involved, it is safe to set the LOD of standard B cell ImmunoSpot assays at 10 per 10\u003csup\u003e6\u003c/sup\u003e PBMC.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec29\" class=\"Section2\"\u003e \u003ch2\u003e4.3 Upper detection limit\u003c/h2\u003e \u003cp\u003eWhen performed using a serial dilution approach, antigen-specific B cell ImmunoSpot assays do not have an inherent upper detection limit: if SFU counts exceed the linear range even at the lowest cell dilutions, re-testing the sample starting with a lower cell input and/or performing larger serial dilutions (e.g. 3-5-fold) will increase the upper detection limit. This can be as high as detecting a single secretory footprint when B cell hybridomas are tested (data not shown). Thus, the upper detection limit of a B cell ImmunoSpot assay is merely a function of the cell numbers plated.\u003c/p\u003e \u003c/div\u003e"},{"header":"5.0 Quantification limit","content":"\u003cdiv id=\"Sec31\" class=\"Section2\"\u003e \u003ch2\u003e5.1 Lowest limit of quantification\u003c/h2\u003e \u003cp\u003eThe lowest limit of quantification (LLOQ) is the lowest concentration/frequency of antigen-specific ASC within PBMC that can be defined with the minimal required level of accuracy and precision (usually 10% or 20%). For T cell ImmunoSpot assays the term LLOQ is rarely used due to the mathematical considerations of a high %CV at low spot numbers per well [\u003cspan citationid=\"CR4\" class=\"CitationRef\"\u003e4\u003c/span\u003e], and because the background noise and T cell/APC contacts required for T cell activation to occur prevent Poisson\u0026rsquo;s rule from applying for the precise evaluation of rare events.\u003c/p\u003e \u003cp\u003eFor B cell ImmunoSpot measurements, the LLOQ depends on the actual test variant performed. If lowering the LLOQ is desired, plating the cells in multiple replicate wells at high cell numbers per well is the assay approach of choice (see Section \u003cspan refid=\"Sec9\" class=\"InternalRef\"\u003e2.4.2\u003c/span\u003e above). When frequencies are measured in screening tests by serial dilution, the initial cell input and obtaining a SFU count\u0026thinsp;\u0026gt;\u0026thinsp;5 at the third dilution point will set the LLOQ. In the type of single well serial dilution tests we show here, when starting at 3 x 10\u003csup\u003e5\u003c/sup\u003e PBMC, the LLOQ is 67 SFU per 10\u003csup\u003e6\u003c/sup\u003e. Due to the onset of Poisson noise that occurs with low frequency SFU counts, increasing the number of replicate wells in such tests will further improve the LLOQ (Supplemental Fig.\u0026nbsp;12).\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec32\" class=\"Section2\"\u003e \u003ch2\u003e5.2. Upper limit of quantification\u003c/h2\u003e \u003cp\u003eFor T cell assays, the upper limit of quantification (ULOQ) has been defined as the maximum number of individual spots per well the plate reader software can discriminate. Typically, this is achieved by counting spots from PBMC samples treated with a mitogen (or peptide for a donor with a very strong peptide response) and by analyzing the linearity of SFU counts per well and cell numbers plated per well. Applying this approach for S-antigen-specific B cell ImmunoSpot analysis, the ULOQ would be reached at ~\u0026thinsp;100 SFU per well for antigen-specific assays (see Supplemental Fig.\u0026nbsp;10). It should be noted, however, that owing to the smaller and tighter spot morphologies observed in pan Ig assays, the ULOQ is ~\u0026thinsp;300 SFU per well. Of note, the ULOQ is also affected by the software\u0026rsquo;s ability to distinguish individual SFU over elevated background membrane staining caused by the \u0026ldquo;ELISA effect\u0026rdquo; (in which antibody captured distally from the source ASC inevitably accumulates in wells as the number of antigen-specific ASC per well increases, as noted above).\u003c/p\u003e \u003cp\u003eBecause antigen-specific B cell ImmunoSpot testing should always rely on PBMC tested by serial dilution to accommodate the wide range of antigen-specific B\u003csub\u003emem\u003c/sub\u003e frequencies (Supplemental Fig.\u0026nbsp;9), the above definition of ULOQ is not sufficient. Performing the assay with serially diluted samples, this definition of ULOQ applies only for establishing the linear range between cell numbers plated and SFU counts obtained, from which the actual frequencies are calculated by extrapolation. That number will define the ULOQ of the assay performed. For B cell ImmunoSpot tests performed with serial dilutions, the ULOQ is merely a function of the cell numbers plated; by their very nature, such B cell assays\u0026rsquo; inherent ULOQ is 100% of all cells tested.\u003c/p\u003e \u003c/div\u003e \u003cdiv id=\"Sec33\" class=\"Section2\"\u003e \u003ch2\u003e5.3. Linearity\u003c/h2\u003e \u003cp\u003eLinearity for B cell ImmunoSpot assays requires that the numbers of PBMC plated, and the number of SFU counted per well follows a linear function. Such linearity is inherent for detection of individual ASC in solution but will only be observed in a rather narrow range in B cell ImmunoSpot tests between 100 SFU for the antigen-specific test at the high end, and around 10 SFU per well on the low end (under which the Poisson noise comes into play, and only measurements done in increasing numbers of replicate wells can reveal the precise frequency. B cell ImmunoSpot assays with serial dilutions will reveal this linear range for each PBMC sample, from which SFU frequencies are to be calculated with the R\u003csup\u003e2\u003c/sup\u003e value revealing the precision for the goodness of fit. By the very nature of the test, any significant deviation from linearity in the 10 to \u0026lt;\u0026thinsp;100 SFU per well range can only result (a) from imprecise pipetting while performing the cell dilution series, (b) from damaging the cells through applying vigorous sheer forces while making the dilution series and pipetting, and/or (c), by damaging the membrane during cell transfers (see Note 38), or by counting parameters set incorrectly on the reader (both of the latter being verifiable by visual inspection of the deviant wells in QC mode). While in the 10 to \u0026lt;\u0026thinsp;100 SFU per well range, measurements of single well serial dilutions will enable accurate frequency calculations based on linearity fits (Supplemental Fig.\u0026nbsp;15), at \u0026lt;\u0026thinsp;20 SFU counts the Poisson noise increasingly affects the precision of linearity/frequency calculations. Increasing the number of replicate wells can increase the precision of linearity in this low count range.\u003c/p\u003e \u003c/div\u003e"},{"header":"6.0. Precision across different types of assays","content":"\u003cp\u003eOur analysis of SARS-CoV-2 S-antigen-specific B\u003csub\u003emem\u003c/sub\u003e reactivity so far, whether assessed in vaccinated individuals, in unvaccinated infected people, or in those both vaccinated and infected, showed that only IgG and IgA class-determinations provided readily interpretable results (Supplemental Fig.\u0026nbsp;8, and work in progress). In polyclonally-stimulated PBMC, IgM\u003csup\u003e+\u003c/sup\u003e S-antigen-reactive SFU were detectable in na\u0026iuml;ve, pre-pandemic PBMC samples at frequencies similar to verifiably exposed individuals (Supplemental Fig.\u0026nbsp;8B), a finding we attribute to the presence of low affinity, broadly cross-reactive na\u0026iuml;ve B cells. Therefore, S-antigen-reactive IgM\u003csup\u003e+\u003c/sup\u003e ASC in polyclonally stimulated PBMC lack diagnostic specificity. In contrast, S-antigen-specific IgM\u003csup\u003e+\u003c/sup\u003e ASC can be detected in PBMC collected acutely following initiation of a COVID-19 mRNA-elicited immune response, identifying \u003cem\u003ein vivo\u003c/em\u003e-induced not (yet) class-switched B cells (Note 56) [\u003cspan citationid=\"CR47\" class=\"CitationRef\"\u003e47\u003c/span\u003e]. Although our four-color multiplexed assay has been optimized for detecting IgE\u003csup\u003e+\u003c/sup\u003e ASC [\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e, \u003cspan citationid=\"CR48\" class=\"CitationRef\"\u003e48\u003c/span\u003e], thus far we have not detected any IgE\u003csup\u003e+\u003c/sup\u003e ASC following polyclonal (TLR7/8\u0026thinsp;+\u0026thinsp;rIL-2, B-Poly-S) stimulation of PBMC isolated from healthy (non-allergic) individuals (Supplemental Fig.\u0026nbsp;5B and Note 38). Therefore, one might argue that a two-color IgA/IgG ELISPOT or FluoroSpot assay would suffice for monitoring the S-antigen-specific B\u003csub\u003emem\u003c/sub\u003e compartment.\u003c/p\u003e \u003cp\u003eFor pan Ig detection, we have established that single-color enzymatic, and single- or multicolor fluorescent B cell ImmunoSpot assays yield nearly identical SFU counts (Supplemental Fig.\u0026nbsp;14, and [\u003cspan citationid=\"CR40\" class=\"CitationRef\"\u003e40\u003c/span\u003e]). However, such polyclonal assays fundamentally differ from antigen-specific B cell ImmunoSpot detection. In the former, the ASC-derived Ig is captured by high affinity antibodies, irrespective of the ASC-derived antibody affinity for the antigen, i.e., only the amount of Ig secreted (productivity) per ASC will define the quantity of ASC-derived Ig retained on the membrane (see Supplemental Fig.\u0026nbsp;1C). For antigen-specific assays, in contrast, the antibodies\u0026rsquo; affinity for the antigen will decisively define their binding to the coated membrane (see Supplemental Fig.\u0026nbsp;1A \u0026amp; B). It could be expected that, due to enzymatic amplification, ELISPOT assays will be more sensitive in detecting \u0026ldquo;faint\u0026rdquo; secretory footprints originating from low affinity ASC than when these are detected via immunofluorescence, without amplification. Without carrying out a full validation effort, we performed preliminary assays to test the precision across these assays. Cryopreserved PBMC from an individual known to possess B\u003csub\u003emem\u003c/sub\u003e-derived ASC secreting either IgG or IgA (at different frequencies) following \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation were re-tested in S-antigen-specific assays for secretory footprints detected in two-color enzymatic (DCE), two-color fluorescent (DCF) assays detecting IgA\u003csup\u003e+\u003c/sup\u003e and IgG\u003csup\u003e+\u003c/sup\u003e ASC, or in a four-color MAGE assay. The results are shown in Supplemental Fig.\u0026nbsp;17, revealing no major differences in SFU counts.\u003c/p\u003e"},{"header":"7.0 Pre-analytical considerations","content":"\u003cp\u003ePre-analytical considerations refer to the (many) variables that can be present between blood collection and the actual analysis of the PBMC in the antigen-specific B cell ImmunoSpot assay. These are similar to those that can affect T cell ImmunoSpot test results, but, while they have been extensively studied for T cells, no such systematic studies exist to date on B cells. Here we also need to distinguish between circulating antigen-specific B cell plasmablasts, that are metabolically highly active cells, and resting B\u003csub\u003emem\u003c/sub\u003e. Most of our experience has been gained studying the latter, and they are also the main focus of this paper. While working towards reliable and consistent detection of underlying B\u003csub\u003emem\u003c/sub\u003e, thus far we have adhered to pre-analytical considerations established for detecting resting memory cells in T cell ImmunoSpot assays. Nonetheless, we have gained the overall impression that the lessons learned in the T cell field will also apply to the pre-analytical considerations for B\u003csub\u003emem\u003c/sub\u003e testing.\u003c/p\u003e \u003cp\u003eWhen the blood is drawn, it is important to avoid unnecessary sheer forces to prevent hemolysis or damage to the white blood cells (e.g. by using a 21G needle to avoid forceful aspiration) and using heparin as the anticoagulant. Until cryopreservation or testing, the cells should be kept in whole blood, rather than as separated PBMC, and at ambient temperature (25-35\u003csup\u003eo\u003c/sup\u003eC) in the dark (never chilled or kept on ice). Our preliminary results obtained so far showed that, stored (or shipped) in this way, B\u003csub\u003emem\u003c/sub\u003e preserve their full functionality for at least 24 h (Yao, work in progress). Accordingly, overnight shipment of blood (at controlled ambient temperature) from clinical sites to central test facilities is not expected to interfere with the test results. For the isolation of PBMC from the blood, density gradient centrifugation over a medium with a density of 1.077g/mL (e.g. Lymphoprep\u0026trade; or Ficoll-Paque\u0026trade;) is the method of choice for T cell assays, and also works well for B cells. In fact, B cell assays are likely to be less sensitive to the PBMC separation method, but this still needs to be confirmed. Cells should continue to be kept at ambient temperature during isolation, and for short-term storage of the PBMC after isolation until initiation of the testing, or cryopreservation.\u003c/p\u003e \u003cp\u003ePBMC can be cryopreserved to maintain full T- [\u003cspan citationid=\"CR49\" class=\"CitationRef\"\u003e49\u003c/span\u003e] and B memory cell activity [\u003cspan citationid=\"CR43\" class=\"CitationRef\"\u003e43\u003c/span\u003e]. For T cell assays, freezing PBMC without serum has been essential to avoid the effects of suppressive effects or stimulatory effects caused by bioactive molecules present in serum. Serum-free freezing also works perfectly for B cells, and we have been routinely doing this. Any number of PBMC can be frozen at a cell density between 0.5\u0026ndash;10 x 10\u003csup\u003e6\u003c/sup\u003e per cryovial, with B cell functionality fully retained following \u003cem\u003ein vitro\u003c/em\u003e polyclonal stimulation (Becza, work in progress). This approach permits freezing multiple PBMC aliquots and facilitates careful study design (Note 42).\u003c/p\u003e \u003cp\u003eStarting the freezing process by adding DMSO-containing cryopreservation medium that is warmed to the same ambient temperature as the cells is key to success (Note 57). For the actual cryopreservation, using a rate-controlled freezer is preferable, but in our hands has no detectable advantage over freezing in Mr. Frosty\u0026trade; freezing containers, or even just using the \u0026ldquo;low tech\u0026rdquo; approach in which two suitable styrofoam racks are sandwiched together in a loose plastic bag wrap (containing plenty of air) prior to placing the cells in the \u0026minus;\u0026thinsp;80\u003csup\u003eo\u003c/sup\u003eC freezer short-term. Cryopreserved cells should be transferred to liquid nitrogen within 24 h; storing them longer in the \u0026minus;\u0026thinsp;80\u003csup\u003eo\u003c/sup\u003eC freezer should be avoided. Partial warming up of cryovials during storage should be avoided to prevent \u0026ldquo;glass phase\u0026rdquo; transitions from occurring, which can damage cryopreserved cells [\u003cspan citationid=\"CR50\" class=\"CitationRef\"\u003e50\u003c/span\u003e]. Even before thawing, cryovials should not be kept in the \u0026minus;\u0026thinsp;80\u003csup\u003eo\u003c/sup\u003eC freezer for longer than 24 h [\u003cspan citationid=\"CR51\" class=\"CitationRef\"\u003e51\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eFor thawing the PBMC, follow the protocol described in [\u003cspan citationid=\"CR52\" class=\"CitationRef\"\u003e52\u003c/span\u003e]. Here too, bringing the contents of the cryovial up to 37\u003csup\u003eo\u003c/sup\u003eC by placing it in a water bath (or better for sterility, in a glass bead bath) before dilution of the DMSO is advisable. The cells can be maintained at 37\u003csup\u003eo\u003c/sup\u003eC, in 10% (v/v) DMSO-containing cryopreservation medium for \u0026gt;\u0026thinsp;30 min without appreciable differences in functionality. Therefore, many cryovials can be thawed simultaneously to facilitate high throughput testing. The addition of warm washing medium containing Benzonase (Note 58) is required for obtaining the best result (definitively better results than following the classical protocol that suggests thawing cryovials one by one until the last ice crystal is visible in the cryovial, followed by immediate washing with ice-cold medium [\u003cspan citationid=\"CR49\" class=\"CitationRef\"\u003e49\u003c/span\u003e].\u003c/p\u003e \u003cp\u003eFor subsequent polyclonal B cell stimulation, fetal calf serum (FCS)-containing culture medium is required. The serum-free media that work so well for T cell assays, and are ideal for standardization of assay conditions for T cell ImmunoSpot [\u003cspan citationid=\"CR53\" class=\"CitationRef\"\u003e53\u003c/span\u003e], do not contain the necessary growth factors required to support the transition of resting B\u003csub\u003emem\u003c/sub\u003e into ASC during the 5 days of \u003cem\u003ein vitro\u003c/em\u003e stimulation (Note 60 and 61). Unlike T cell assays, in which different FCS batches can have profound effects on assay performance [\u003cspan citationid=\"CR53\" class=\"CitationRef\"\u003e53\u003c/span\u003e], in our preliminary assessments so far, we did not find FCS to be a critical assay variable (Supplemental Fig.\u0026nbsp;18), but this notion needs additional robust verification.\u003c/p\u003e \u003cp\u003eA combination of the TLR7/8 ligand R848 and recombinant human interleukin 2 (rIL-2) is commonly used to achieve potent polyclonal B cell stimulation for downstream assessment in B cell ImmunoSpot tests [\u003cspan citationid=\"CR54\" class=\"CitationRef\"\u003e54\u003c/span\u003e, \u003cspan citationid=\"CR55\" class=\"CitationRef\"\u003e55\u003c/span\u003e]. It is also ideal for studies of Ig class and subclass expression by B\u003csub\u003emem\u003c/sub\u003e \u003cem\u003ein vivo\u003c/em\u003e, because it does not provide signals that promote Ig class switching during the \u003cem\u003ein vitro\u003c/em\u003e stimulation culture period (Note 61). Owing to the potential variable that different batches of polyclonal stimulation reagent(s) may possess different potencies, we recommend to always include a positive control PBMC sample alongside the test sample(s) to verify the potency of the polyclonal stimulation culture by establishing in a pan Ig assay that the maximal numbers of Ig-producing ASC have indeed been induced (Note 63). Supplemental Fig.\u0026nbsp;2A-C shows that maximal IgM\u003csup\u003e+\u003c/sup\u003e, IgA\u003csup\u003e+\u003c/sup\u003e and IgG\u003csup\u003e+\u003c/sup\u003e ASC activity following R848\u0026thinsp;+\u0026thinsp;rIL-2 (B-Poly-S) stimulation occurred after 5 days of \u003cem\u003ein vitro\u003c/em\u003e stimulation for most donors tested. Of paramount importance for performing B cell ImmunoSpot tests following \u003cem\u003ein vitro\u003c/em\u003e stimulation of the test samples is the need to thoroughly wash the cells to remove any \u0026ldquo;specific\u0026rdquo; Ig present in the culture supernatant before plating into the actual assay, as this can increase the background staining of the membrane and interfere with detection of antigen-specific ASC.\u003c/p\u003e"},{"header":"8.0. Concluding remarks","content":"\u003cp\u003eIn Note 42 we have provided an experimental plan for how - using only 2.2 x 10\u003csup\u003e7\u003c/sup\u003e PBMC in total \u0026ndash; to generate all data required for the validation of an antigen-specific B cell ImmunoSpot assay. The plate layout shown in Supplemental Fig.\u0026nbsp;5A permits the subsequent high throughput testing of clinical samples requiring only 1\u0026ndash;2 x 10\u003csup\u003e6\u003c/sup\u003e PBMC per test subject to determine the frequency of antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived ASC secreting all four classes of Ig. Detailed protocols (a link to Supplemental Materials and Methods can be found at the end of this paper, under \u0026ldquo;\u003cspan refid=\"Sec37\" class=\"InternalRef\"\u003eAppendix\u003c/span\u003e\u0026rdquo;) and in-depth technical and theoretical comments provided above should help laboratories interested in B cell immune monitoring adopt this technique to develop and validate such assays for their antigens of interest.\u003c/p\u003e \u003cp\u003eThe above considerations apply for testing frequencies of resting, antigen-specific B\u003csub\u003emem\u003c/sub\u003e cells. While dramatic frequency increases are seen following primary and secondary antigen challenge, frequency changes after additional antigen encounters may no longer be as notable after B cell memory has been established. In such cases, the elicitation of a plasmablast response (Note 44) or changes in the affinity of antigen-specific ASC may provide evidence for the re-activation of a B cell response. As indicated previously above, the detection of such antigen-specific plasmablasts follows the same approach as described for B\u003csub\u003emem\u003c/sub\u003e except that the actual B cell ImmunoSpot testing is done with freshly isolated PBMC (or after such cells are cryopreserved and thawed), without the requirement for prior polyclonal stimulation (Note 64). For in-depth studies of affinity distributions within the antigen-specific B cell repertoire, an approach described in [\u003cspan citationid=\"CR25\" class=\"CitationRef\"\u003e25\u003c/span\u003e] is best suited.\u003c/p\u003e \u003cp\u003eIn addition to assessing the frequency of antigen-specific B\u003csub\u003emem\u003c/sub\u003e-derived ASC (or plasmablasts), four-color ImmunoSpot assays described here are also uniquely suited to studying additional Ig class (and IgG subclass) switching that can occur with repeated antigen encounters. Recently, for example, attention has been drawn to the change within the S-antigen-specific IgG response after repeated booster immunizations: an initially IgG1/IgG3 polarized B cell response switching to a mixed IgG1/IgG4 composition [\u003cspan citationid=\"CR56\" class=\"CitationRef\"\u003e56\u003c/span\u003e], a finding we have also confirmed performing four-color S-antigen-specific IgG subclass analysis. Such shifts are of major clinical significance because IgG1 and IgG4 have antagonistic immuno-biological effects (Note 65). IgG subclass-detecting four-color assays follow the same protocols described above, except that the detection reagents used are IgG subclass-, instead of Ig class-specific.\u003c/p\u003e \u003cp\u003eAll of these recent developments in B cell immune monitoring abilities have opened a new window onto the thus far hidden universe of B\u003csub\u003emem\u003c/sub\u003e responses by employing B cell ImmunoSpot\u0026reg; analysis, greatly supplementing what can be discerned by the present, limited, techniques deployed for immune monitoring of humoral immunity.\u003c/p\u003e"},{"header":"Declarations","content":"\u003ch2\u003eDeclaration of Competing Interest\u003c/h2\u003e \u003cp\u003eAll authors are employees of CTL and may hold stock.\u003c/p\u003e \u003ch2\u003eFunding\u003c/h2\u003e \u003cp\u003eAll funding for this work came from CTL\u0026rsquo;s R\u0026amp;D budget.\u003c/p\u003e\u003ch2\u003eAuthor Contributions\u003c/h2\u003e \u003cp\u003e \u003cem\u003eConceptualization\u003c/em\u003e: PVL and GAK; \u003cem\u003eData Curation\u003c/em\u003e: AVG and GAK; \u003cem\u003eFormal Analysis\u003c/em\u003e: AYK, NB, LLY, JC, CW, SK, AVG and GAK; \u003cem\u003eInvestigation\u003c/em\u003e: NB, LLY, ZL, JC, AMP, CW, SK, AV, AVG and GAK; \u003cem\u003eMethodology\u003c/em\u003e: PVL, NB, ZL, GAK; \u003cem\u003eProject administration\u003c/em\u003e: PVL, AVG and GAK; \u003cem\u003eResources\u003c/em\u003e: AYK, ZL, JC and GAK; \u003cem\u003eSoftware\u003c/em\u003e: AYK, \u003cem\u003eSupervision\u003c/em\u003e: PVL, MTL and GAK; \u003cem\u003eVisualization\u003c/em\u003e: AYK, NB, LLY, JC and GAK; \u003cem\u003eWriting\u003c/em\u003e: PVL and GAK; \u003cem\u003eReview \u0026amp; editing\u003c/em\u003e: PVL, AYK, MTL and GAK\u003c/p\u003e\u003ch2\u003eAcknowledgements\u003c/h2\u003e \u003cp\u003eThe authors would like to thank Dr. Graham Pawelec for critical review and editing the manuscript.\u003c/p\u003e\u003ch2\u003eData availability\u003c/h2\u003e \u003cp\u003eQualified researchers may request access to test subject-related data and related documents. Such data will be anonymized, and study documents will be redacted to protect the privacy of trial participants.\u003c/p\u003e"},{"header":"References","content":"\u003col\u003e\u003cli\u003e\u003cspan\u003eCzerkinsky CC et al (1983) A solid-phase enzyme-linked immunospot (ELISPOT) assay for enumeration of specific antibody-secreting cells. J Immunol Methods 65(1\u0026ndash;2):109\u0026ndash;121\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSedgwick JD, Holt PG (1983) A solid-phase immunoenzymatic technique for the enumeration of specific antibody-secreting cells. J Immunol Methods 57(1\u0026ndash;3):301\u0026ndash;309\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCzerkinsky C et al (1988) Reverse ELISPOT assay for clonal analysis of cytokine production. I. Enumeration of gamma-interferon-secreting cells. J Immunol Methods 110(1):29\u0026ndash;36\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKorber N et al (2016) Validation of an IFNgamma/IL2 FluoroSpot assay for clinical trial monitoring. J Transl Med 14(1):175\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLehmann PV (1995) Methods for measuring T-cell cytokines. United States\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHesse MD et al (2001) A T cell clone's avidity is a function of its activation state. J Immunol 167(3):1353\u0026ndash;1361\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eForsthuber T, Yip HC, Lehmann PV (1996) Induction of TH1 and TH2 immunity in neonatal mice. Science 271(5256):1728\u0026ndash;1730\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eZhang W, Lehmann PV (2012) Objective, user-independent ELISPOT data analysis based on scientifically validated principles. Methods Mol Biol 792:155\u0026ndash;171\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSlota M et al (2011) ELISpot for measuring human immune responses to vaccines. Expert Rev Vaccines 10(3):299\u0026ndash;306\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eShafer-Weaver K et al (2006) Application of the granzyme B ELISPOT assay for monitoring cancer vaccine trials. J Immunother 29(3):328\u0026ndash;335\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePass HA et al (1998) Immunization of patients with melanoma peptide vaccines: immunologic assessment using the ELISPOT assay. Cancer J Sci Am 4(5):316\u0026ndash;323\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMalyguine A et al (2007) New approaches for monitoring CTL activity in clinical trials. Adv Exp Med Biol 601:273\u0026ndash;284\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRanieri E, Popescu I, Gigante M (2014) CTL ELISPOT assay. Methods Mol Biol 1186:75\u0026ndash;86\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKoppert S et al (2021) \u003cem\u003eAffinity Tag Coating Enables Reliable Detection of Antigen-Specific B Cells in Immunospot Assays\u003c/em\u003e. Cells, 10(8)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eTerlutter F et al (2018) \u003cem\u003eDirect Detection of T- and B-Memory Lymphocytes by ImmunoSpot(R) Assays Reveals HCMV Exposure that Serum Antibodies Fail to Identify\u003c/em\u003e. Cells, 7(5)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWolf C et al (2022) \u003cem\u003eAntibody Levels Poorly Reflect on the Frequency of Memory B Cells Generated following SARS-CoV-2, Seasonal Influenza, or EBV Infection\u003c/em\u003e. Cells, 11(22)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKuerten S et al (2014) Identification of a B cell-dependent subpopulation of multiple sclerosis by measurements of brain-reactive B cells in the blood. Clin Immunol 152(1\u0026ndash;2):20\u0026ndash;24\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRobinson MJ et al (2023) Intrinsically determined turnover underlies broad heterogeneity in plasma-cell lifespan. Immunity 56(7):1596\u0026ndash;1612e4\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLong QX et al (2020) Clinical and immunological assessment of asymptomatic SARS-CoV-2 infections. Nat Med 26(8):1200\u0026ndash;1204\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eGaebler C et al (2021) Evolution of antibody immunity to SARS-CoV-2. Nature 591(7851):639\u0026ndash;644\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSeow J et al (2020) Longitudinal observation and decline of neutralizing antibody responses in the three months following SARS-CoV-2 infection in humans. Nat Microbiol 5(12):1598\u0026ndash;1607\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eXiang T et al (2021) Declining Levels of Neutralizing Antibodies Against SARS-CoV-2 in Convalescent COVID-19 Patients One Year Post Symptom Onset. Front Immunol 12:708523\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAkkaya M, Kwak K, Pierce SK (2020) B cell memory: building two walls of protection against pathogens. Nat Rev Immunol 20(4):229\u0026ndash;238\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eP.V., L., et al., \u003cem\u003eMonitoring memory B cells by next generation ImmunoSpot\u0026reg; provides insights into humoral immunity that measurements of circulating antibodies do not reveal\u003c/em\u003e. Methods Mol Biol, (2023)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBecza N et al (2023) \u003cem\u003eAssessing the affinity spectrum of the antigen-specific B cell repertoire via ImmunoSpot\u0026reg;\u003c/em\u003e. Methods Mol Biol\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eAdministration FaD (2018) \u003cem\u003eBioanalytical method validation guidance for industry\u003c/em\u003e. 04/29/2020 [cited 2024 February 1]\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eTary-Lehmann M, Hamm CD, Lehmann PV (2008) \u003cem\u003eValidating Reference Samples for Comparison in a Regulated ELISPOT Assay\u003c/em\u003e, in \u003cem\u003eValidation of Cell-Based Assays in the GLP Setting\u003c/em\u003e. p. 127\u0026ndash;146\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWeiss AJ (2012) Overview of membranes and membrane plates used in research and diagnostic ELISPOT assays. Methods Mol Biol 792:243\u0026ndash;256\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBisceglia H et al (2023) A FluoroSpot B assay for the detection of IgA and IgG SARS-CoV-2 spike-specific memory B cells: Optimization and qualification for use in COVID-19 vaccine trials. J Immunol Methods 515:113457\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKarulin AY, Lehmann PV (2012) How ELISPOT morphology reflects on the productivity and kinetics of cells' secretory activity. Methods Mol Biol 792:125\u0026ndash;143\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWysocki L, Manser T, Gefter ML (1986) Somatic evolution of variable region structures during an immune response. Proc Natl Acad Sci U S A 83(6):1847\u0026ndash;1851\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWrammert J et al (2008) Rapid cloning of high-affinity human monoclonal antibodies against influenza virus. Nature 453(7195):667\u0026ndash;671\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePadlan EA et al (1989) Structure of an antibody-antigen complex: crystal structure of the HyHEL-10 Fab-lysozyme complex. Proc Natl Acad Sci U S A 86(15):5938\u0026ndash;5942\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMoulana A et al (2023) \u003cem\u003eThe landscape of antibody binding affinity in SARS-CoV-2 Omicron BA.1 evolution\u003c/em\u003e. Elife, 12\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDzimianski JV et al (2023) Structural insights into the broad protection against H1 influenza viruses by a computationally optimized hemagglutinin vaccine. Commun Biol 6(1):454\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDi Niro R et al (2015) Salmonella Infection Drives Promiscuous B Cell Activation Followed by Extrafollicular Affinity Maturation. Immunity 43(1):120\u0026ndash;131\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDal Porto JM et al (2002) Very low affinity B cells form germinal centers, become memory B cells, and participate in secondary immune responses when higher affinity competition is reduced. J Exp Med 195(9):1215\u0026ndash;1221\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLiao HX et al (2013) Co-evolution of a broadly neutralizing HIV-1 antibody and founder virus. Nature 496(7446):469\u0026ndash;476\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWang TT et al (2017) IgG antibodies to dengue enhanced for FcgammaRIIIA binding determine disease severity. Science 355(6323):395\u0026ndash;398\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYao L et al (2023) Four-color ImmunoSpot\u0026reg; assays requiring only 1\u0026ndash;3 mL of blood permit precise frequency measurements of antigen-specific B cells secreting immunoglobulins of all four classes and subclasses. Methods. Mol. Biol\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eStavnezer J, Guikema JE, Schrader CE (2008) Mechanism and regulation of class switch recombination. Annu Rev Immunol 26:261\u0026ndash;292\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKarulin AY et al (2018) Multiplexing T- and B-Cell FLUOROSPOT Assays: Experimental Validation of the Multi-Color ImmunoSpot((R)) Software Based on Center of Mass Distance Algorithm. Methods Mol Biol 1808:95\u0026ndash;113\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eFecher P et al (2018) \u003cem\u003eB Cells and B Cell Blasts Withstand Cryopreservation While Retaining Their Functionality for Producing Antibody\u003c/em\u003e. Cells, 7(6)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eVictora GD, Nussenzweig MC (2022) Germinal Centers Annu Rev Immunol 40:413\u0026ndash;442\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNickbakhsh S et al (2020) Epidemiology of Seasonal Coronaviruses: Establishing the Context for the Emergence of Coronavirus Disease 2019. J Infect Dis 222(1):17\u0026ndash;25\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNagele EP et al (2013) Natural IgG autoantibodies are abundant and ubiquitous in human sera, and their number is influenced by age, gender, and disease. PLoS ONE 8(4):e60726\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePape KA et al (2021) High-affinity memory B cells induced by SARS-CoV-2 infection produce more plasmablasts and atypical memory B cells than those primed by mRNA vaccines. Cell Rep 37(2):109823\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eFranke F et al (2020) \u003cem\u003eIL-21 in Conjunction with Anti-CD40 and IL-4 Constitutes a Potent Polyclonal B Cell Stimulator for Monitoring Antigen-Specific Memory B Cells\u003c/em\u003e. Cells, 9(2)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKreher CR et al (2003) CD4\u0026thinsp;+\u0026thinsp;and CD8\u0026thinsp;+\u0026thinsp;cells in cryopreserved human PBMC maintain full functionality in cytokine ELISPOT assays. J Immunol Methods 278(1\u0026ndash;2):79\u0026ndash;93\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSmith JG et al (2007) Establishing acceptance criteria for cell-mediated-immunity assays using frozen peripheral blood mononuclear cells stored under optimal and suboptimal conditions. Clin Vaccine Immunol 14(5):527\u0026ndash;537\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWunsch M et al (2015) Serial Measurements of Apoptotic Cell Numbers Provide Better Acceptance Criterion for PBMC Quality than a Single Measurement Prior to the T Cell Assay. Cells 4(1):40\u0026ndash;55\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRamachandran H et al (2012) Optimal thawing of cryopreserved peripheral blood mononuclear cells for use in high-throughput human immune monitoring studies. Cells 1(3):313\u0026ndash;324\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eJanetzki S et al (2010) Performance of serum-supplemented and serum-free media in IFNgamma Elispot Assays for human T cells. Cancer Immunol Immunother 59(4):609\u0026ndash;618\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eJahnmatz M et al (2013) Optimization of a human IgG B-cell ELISpot assay for the analysis of vaccine-induced B-cell responses. J Immunol Methods 391(1\u0026ndash;2):50\u0026ndash;59\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003ePinna D et al (2009) Clonal dissection of the human memory B-cell repertoire following infection and vaccination. Eur J Immunol 39(5):1260\u0026ndash;1270\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eIrrgang P et al (2023) Class switch toward noninflammatory, spike-specific IgG4 antibodies after repeated SARS-CoV-2 mRNA vaccination. Sci Immunol 8(79):eade2798\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLehmann PV, Lehmann AA (2020) Aleatory epitope recognition prevails in human T cell responses? Crit Rev Immunol 40(3):225\u0026ndash;235\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKarulin AY et al (2015) ELISPOTs produced by CD8 and CD4 cells follow log normal size distribution permitting objective counting. Cells 4(1):56\u0026ndash;70\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSundararaman S et al (2015) High reproducibility of ELISPOT counts from nine different laboratories. Cells 4(1):21\u0026ndash;39\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eKarulin AY et al (2023) \u003cem\u003eArtificial intelligence-based counting algorithm enables accurate and detailed analysis of the broad-spectrum of spot morphologies observed in antigen-specific B cell ELISPOT and FLUOROSPOT assays\u003c/em\u003e. Methods Mol Biol\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMorell A, Terry WD, Waldmann TA (1970) Metabolic properties of IgG subclasses in man. J Clin Invest 49(4):673\u0026ndash;680\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBlandino R, Baumgarth N (2019) Secreted IgM: New tricks for an old molecule. J Leukoc Biol 106(5):1021\u0026ndash;1034\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003evan Tetering G et al (2020) \u003cem\u003eFc Engineering strategies to advance IgA antibodies as therapeutic agents\u003c/em\u003e. Antibodies (Basel), 9(4)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNormansell R et al \u003cem\u003eOmalizumab for asthma in adults and children\u003c/em\u003e. Cochrane Database Syst Rev, 2014(1): p. CD003559\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eArdeniz O et al (2015) beta2-Microglobulin deficiency causes a complex immunodeficiency of the innate and adaptive immune system. J Allergy Clin Immunol 136(2):392\u0026ndash;401\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eStapleton NM et al (2011) Competition for FcRn-mediated transport gives rise to short half-life of human IgG3 and offers therapeutic potential. Nat Commun 2:599\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eBruhns P, Jonsson F (2015) Mouse and human FcR effector functions. Immunol Rev 268(1):25\u0026ndash;51\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLee CM, Oh JE (2022) Resident memory B cells in barrier tissues. Front Immunol 13:953088\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eChu RS et al (1997) CpG oligodeoxynucleotides act as adjuvants that switch on T helper 1 (Th1) immunity. J Exp Med 186(10):1623\u0026ndash;1631\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eYip HC et al (1999) Adjuvant-guided type-1 and type-2 immunity: infectious/noninfectious dichotomy defines the class of response. J Immunol 162(7):3942\u0026ndash;3949\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eWebb NE, Bernshtein B, Alter G (2021) Tissues: the unexplored frontier of antibody mediated immunity. Curr Opin Virol 47:52\u0026ndash;67\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMuir L et al (2017) Optimisation of ex vivo memory B cell expansion/differentiation for interrogation of rare peripheral memory B cell subset responses. Wellcome Open Res 2:97\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMei HE et al (2009) Blood-borne human plasma cells in steady state are derived from mucosal immune responses. Blood 113(11):2461\u0026ndash;2469\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRispens T, Huijbers MG (2023) The unique properties of IgG4 and its roles in health and disease. Nat Rev Immunol 23(11):763\u0026ndash;778\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMueller SN, Ahmed R (2009) High antigen levels are the cause of T cell exhaustion during chronic viral infection. Proc Natl Acad Sci U S A 106(21):8623\u0026ndash;8628\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHelms T et al (2000) Direct visualization of cytokine-producing recall antigen-specific CD4 memory T cells in healthy individuals and HIV patients. J Immunol 164(7):3723\u0026ndash;3732\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eTargoni OS, Lehmann PV (1998) Endogenous myelin basic protein inactivates the high avidity T cell repertoire. J Exp Med 187(12):2055\u0026ndash;2063\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eTaylor JJ et al (2012) Deletion and anergy of polyclonal B cells specific for ubiquitous membrane-bound self-antigen. J Exp Med 209(11):2065\u0026ndash;2077\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eRoss TM et al (2022) \u003cem\u003eKinetic of the antibody response following AddaVax-adjuvanted immunization with recombinant influenza antigens\u003c/em\u003e. Vaccines (Basel), 10(8)\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCzajkowsky DM, Shao Z (2009) The human IgM pentamer is a mushroom-shaped molecule with a flexural bias. Proc Natl Acad Sci U S A 106(35):14960\u0026ndash;14965\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDiebolder CA et al (2014) Complement is activated by IgG hexamers assembled at the cell surface. Science 343(6176):1260\u0026ndash;1263\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eReid KBM (2018) Complement component C1q: Historical perspective of a functionally versatile, and structurally unusual, serum protein. Front Immunol 9:764\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eHanson J et al (2015) ELISPOT assays in 384-well format: up to 30 data points with one million cells. Cells 4(1):71\u0026ndash;83\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eDangi T et al (2023) Pre-existing immunity modulates responses to mRNA boosters. Cell Rep 42(3):112167\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eNunez IA et al (2017) Impact of age and pre-existing influenza immune responses in humans receiving split inactivated influenza vaccine on the induction of the breadth of antibodies to influenza A strains. PLoS ONE 12(11):e0185666\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eLu LL et al (2018) Beyond binding: antibody effector functions in infectious diseases. Nat Rev Immunol 18(1):46\u0026ndash;61\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMoodie Z et al (2006) Statistical positivity criteria for the analysis of ELISpot assay data in HIV-1 vaccine trials. J Immunol Methods 315(1\u0026ndash;2):121\u0026ndash;132\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eMoodie Z et al (2010) Response definition criteria for ELISPOT assays revisited. Cancer Immunol Immunother 59(10):1489\u0026ndash;1501\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eSautto GA et al (2020) A computationally optimized broadly reactive antigen subtype-specific influenza vaccine strategy elicits unique potent broadly neutralizing antibodies against hemagglutinin. J Immunol 204(2):375\u0026ndash;385\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eCarlock MA et al (2019) Impact of age and pre-existing immunity on the induction of human antibody responses against influenza B viruses. Hum Vaccin Immunother 15(9):2030\u0026ndash;2043\u003c/span\u003e\u003c/li\u003e \u003cli\u003e\u003cspan\u003eEcker JW et al (2020) \u003cem\u003eHigh-yield expression and purification of recombinant influenza virus proteins from stably-transfected mammalian cell lines\u003c/em\u003e. Vaccines (Basel), 8(3)\u003c/span\u003e\u003c/li\u003e\u003c/ol\u003e"}],"fulltextSource":"","fullText":"","funders":[],"hasOptedInToPreprint":true,"hasPassedJournalQc":"","hideJournal":true,"highlight":"","institution":"Cellular Technology Limited","isAuthorSuppliedPdf":false,"isDeskRejected":"","isHiddenFromSearch":false,"isInQc":false,"isInWorkflow":false,"isPdf":false,"isPdfUpToDate":true,"journal":{"display":true,"email":"info@researchsquare.com","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true},"keywords":"ELISPOT, FluoroSpot, B cells, immune monitoring, immune memory, Ig class, IgG subclass, high throughput, antibody-secreting cell","license":{"name":"CC BY 4.0","url":"https://creativecommons.org/licenses/by/4.0/"},"manuscriptAbstract":"\u003cp\u003eOwing to their ability to reliably detect even very rare antigen-specific B cells in cellular isolates such as peripheral blood mononuclear cells (PBMC), and doing so robustly in a high throughput-compatible manner, B cell ELISPOT/FluoroSpot (collectively \u0026ldquo;B cell ImmunoSpot\u0026rdquo;) tests have become increasingly attractive for immune monitoring in regulated settings. Presently, there are no guidelines for the qualification and validation of B cell ImmunoSpot assay results. Here, we propose such guidelines, building on the experience acquired from T cell ImmunoSpot testing in an environment adhering to the requirements of regulatory bodies yet taking the unique features of B cell assays into account. A streamlined protocol is proposed that permits the performance of all tests needed for the formal validation of an antigen-specific B cell ImmunoSpot assay in only three experiments, utilizing 2.2 x 10\u003csup\u003e7\u003c/sup\u003e PBMC per donor. Subsequently, utilizing only 1\u0026ndash;2 x 10\u003csup\u003e6\u003c/sup\u003e PBMC per sample (obtainable from 1\u0026ndash;2 mL of blood), a validated multiplexed assay enables accurate quantification of the frequency of antigen-specific memory B cell-derived blasts secreting IgM, IgG, IgA or IgE antibodies. Collectively, such multiplexed B cell ImmunoSpot assays offer immense value for B cell immune monitoring programs due to their ease of implementation, scalability, applicability to essentially any antigenic system, economy of PBMC utilization, and last but not least, the high content information gained.\u003c/p\u003e","manuscriptTitle":"Theoretical and practical considerations for validating antigen-specific B cell ImmunoSpot assays","msid":"","msnumber":"","nonDraftVersions":[{"code":1,"date":"2024-02-29 14:44:42","doi":"10.21203/rs.3.rs-3994852/v1","editorialEvents":[{"type":"communityComments","content":0}],"status":"published","journal":{"display":true,"email":"info@researchsquare.com","identity":"researchsquare","isNatureJournal":false,"hasQc":true,"allowDirectSubmit":true,"externalIdentity":"","sideBox":"","snPcode":"","submissionUrl":"/submission","title":"Research Square","twitterHandle":"researchsquare","acdcEnabled":true,"dfaEnabled":false,"editorialSystem":"","reportingPortfolio":"","inReviewEnabled":false,"inReviewRevisionsEnabled":true}}],"origin":"","ownerIdentity":"3ca79f17-8db8-4d99-bbae-090c2bdb9b39","owner":[],"postedDate":"February 29th, 2024","published":true,"rejectedJournal":[],"revision":"","amendment":"","status":"posted","subjectAreas":[{"id":29014593,"name":"Immunology"}],"tags":[],"versionOfRecord":[],"versionCreatedAt":"2024-02-29 14:44:42","video":"","vorDoi":"","vorDoiUrl":"","workflowStages":[]},"version":"v1","identity":"rs-3994852","journalConfig":"researchsquare"},"__N_SSP":true},"page":"/article/[identity]/[[...version]]","query":{"identity":"rs-3994852","version":["v1"]},"buildId":"BY0jLfL5JqTU-Xr7tfWvz","isFallback":false,"dynamicIds":[59267],"gssp":true,"scriptLoader":[]}</script><div hidden="" id="snipcart" data-api-key="ODA3NTlmNDUtYjRjNy00MzE2LTgzNmYtYjUwY2Y4MWFkOWRlNjM3MTQwMjI1MDM0NDU2MjEx"></div></body></html>