CINXE.COM
Search results for: fire accidents
<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: fire accidents</title> <meta name="description" content="Search results for: fire accidents"> <meta name="keywords" content="fire accidents"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="fire accidents" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="fire accidents"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 1032</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: fire accidents</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1032</span> Study of Fire Propagation and Soot Flow in a Pantry Car of Railway Locomotive</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Juhi%20Kaushik">Juhi Kaushik</a>, <a href="https://publications.waset.org/abstracts/search?q=Abhishek%20Agarwal"> Abhishek Agarwal</a>, <a href="https://publications.waset.org/abstracts/search?q=Manoj%20Sarda"> Manoj Sarda</a>, <a href="https://publications.waset.org/abstracts/search?q=Vatsal%20Sanjay"> Vatsal Sanjay</a>, <a href="https://publications.waset.org/abstracts/search?q=Arup%20Kumar%20Das"> Arup Kumar Das</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Fire accidents in trains bring huge disaster to human life and property. Evacuation becomes a major challenge in such incidents owing to confined spaces, large passenger density and trains moving at high speeds. The pantry car in Indian Railways trains carry inflammable materials like cooking fuel and LPG and electrical fittings. The pantry car is therefore highly susceptible to fire accidents. Numerical simulations have been done in a pantry car of Indian locomotive train using computational fluid dynamics based software. Different scenarios of a fire outbreak have been explored by varying Heat Release Rate per Unit Area (HRRPUA) of the fire source, introduction of exhaust in the cooking area, and taking a case of an air conditioned pantry car. Temporal statures of flame and soot have been obtained for each scenario and differences have been studied and reported. Inputs from this study can be used to assess casualties in fire accidents in locomotive trains and development of smoke control/detection systems in Indian trains. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20propagation" title="fire propagation">fire propagation</a>, <a href="https://publications.waset.org/abstracts/search?q=flame%20contour" title=" flame contour"> flame contour</a>, <a href="https://publications.waset.org/abstracts/search?q=pantry%20fire" title=" pantry fire"> pantry fire</a>, <a href="https://publications.waset.org/abstracts/search?q=soot%20flow" title=" soot flow"> soot flow</a> </p> <a href="https://publications.waset.org/abstracts/50491/study-of-fire-propagation-and-soot-flow-in-a-pantry-car-of-railway-locomotive" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/50491.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">339</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1031</span> Fire and Explosion Consequence Modeling Using Fire Dynamic Simulator: A Case Study</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Iftekhar%20%20Hassan">Iftekhar Hassan</a>, <a href="https://publications.waset.org/abstracts/search?q=Sayedil%20Morsalin"> Sayedil Morsalin</a>, <a href="https://publications.waset.org/abstracts/search?q=Easir%20A%20Khan"> Easir A Khan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Accidents involving fire occur frequently in recent times and their causes showing a great deal of variety which require intervention methods and risk assessment strategies are unique in each case. On September 4, 2020, a fire and explosion occurred in a confined space caused by a methane gas leak from an underground pipeline in Baitus Salat Jame mosque during Night (Esha) prayer in Narayanganj District, Bangladesh that killed 34 people. In this research, this incident is simulated using Fire Dynamics Simulator (FDS) software to analyze and understand the nature of the accident and associated consequences. FDS is an advanced computational fluid dynamics (CFD) system of fire-driven fluid flow which solves numerically a large eddy simulation form of the Navier–Stokes’s equations for simulation of the fire and smoke spread and prediction of thermal radiation, toxic substances concentrations and other relevant parameters of fire. This study focuses on understanding the nature of the fire and consequence evaluation due to thermal radiation caused by vapor cloud explosion. An evacuation modeling was constructed to visualize the effect of evacuation time and fractional effective dose (FED) for different types of agents. The results were presented by 3D animation, sliced pictures and graphical representation to understand fire hazards caused by thermal radiation or smoke due to vapor cloud explosion. This study will help to design and develop appropriate respond strategy for preventing similar accidents. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=consequence%20modeling" title="consequence modeling">consequence modeling</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20and%20explosion" title=" fire and explosion"> fire and explosion</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20dynamics%20simulation%20%28FDS%29" title=" fire dynamics simulation (FDS)"> fire dynamics simulation (FDS)</a>, <a href="https://publications.waset.org/abstracts/search?q=thermal%20radiation" title=" thermal radiation "> thermal radiation </a> </p> <a href="https://publications.waset.org/abstracts/136628/fire-and-explosion-consequence-modeling-using-fire-dynamic-simulator-a-case-study" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/136628.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">225</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1030</span> A Study for the Effect of Fire Initiated Location on Evacuation Success Rate </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jin%20A%20Ryu">Jin A Ryu</a>, <a href="https://publications.waset.org/abstracts/search?q=Hee%20Sun%20Kim"> Hee Sun Kim</a> </p> <p class="card-text"><strong>Abstract:</strong></p> As the number of fire accidents is gradually raising, many studies have been reported on evacuation. Previous studies have mostly focused on evaluating the safety of evacuation and the risk of fire in particular buildings. However, studies on effects of various parameters on evacuation have not been nearly done. Therefore, this paper aims at observing evacuation time under the effect of fire initiated location. In this study, evacuation simulations are performed on a 5-floor building located in Seoul, South Korea using the commercial program, Fire Dynamics Simulator with Evacuation (FDS+EVAC). Only the fourth and fifth floors are modeled with an assumption that fire starts in a room located on the fourth floor. The parameter for evacuation simulations is location of fire initiation to observe the evacuation time and safety. Results show that the location of fire initiation is closer to exit, the more time is taken to evacuate. The case having the nearest location of fire initiation to exit has the lowest ratio of successful occupants to the total occupants. In addition, for safety evaluation, the evacuation time calculated from computer simulation model is compared with the tolerable evacuation time according to code in Japan. As a result, all cases are completed within the tolerable evacuation time. This study allows predicting evacuation time under various conditions of fire and can be used to evaluate evacuation appropriateness and fire safety of building. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20simulation" title="fire simulation">fire simulation</a>, <a href="https://publications.waset.org/abstracts/search?q=evacuation%20simulation" title=" evacuation simulation"> evacuation simulation</a>, <a href="https://publications.waset.org/abstracts/search?q=temperature" title=" temperature"> temperature</a>, <a href="https://publications.waset.org/abstracts/search?q=evacuation%20safety" title=" evacuation safety"> evacuation safety</a> </p> <a href="https://publications.waset.org/abstracts/36360/a-study-for-the-effect-of-fire-initiated-location-on-evacuation-success-rate" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/36360.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">349</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1029</span> Investigations on Pyrolysis Model for Radiatively Dominant Diesel Pool Fire Using Fire Dynamic Simulator</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Siva%20K.%20Bathina">Siva K. Bathina</a>, <a href="https://publications.waset.org/abstracts/search?q=Sudheer%20Siddapureddy"> Sudheer Siddapureddy</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Pool fires are formed when the flammable liquid accidentally spills on the ground or water and ignites. Pool fire is a kind of buoyancy-driven and diffusion flame. There have been many pool fire accidents caused during processing, handling and storing of liquid fuels in chemical and oil industries. Such kind of accidents causes enormous damage to property as well as the loss of lives. Pool fires are complex in nature due to the strong interaction among the combustion, heat and mass transfers and pyrolysis at the fuel surface. Moreover, the experimental study of such large complex fires involves fire safety issues and difficulties in performing experiments. In the present work, large eddy simulations are performed to study such complex fire scenarios using fire dynamic simulator. A 1 m diesel pool fire is considered for the studied cases, and diesel is chosen as it is most commonly involved fuel in fire accidents. Fire simulations are performed by specifying two different boundary conditions: one the fuel is in liquid state and pyrolysis model is invoked, and the other by assuming the fuel is initially in a vapor state and thereby prescribing the mass loss rate. A domain of size 11.2 m × 11.2 m × 7.28 m with uniform structured grid is chosen for the numerical simulations. Grid sensitivity analysis is performed, and a non-dimensional grid size of 12 corresponding to 8 cm grid size is considered. Flame properties like mass burning rate, irradiance, and time-averaged axial flame temperature profile are predicted. The predicted steady-state mass burning rate is 40 g/s and is within the uncertainty limits of the previously reported experimental data (39.4 g/s). Though the profile of the irradiance at a distance from the fire along the height is somewhat in line with the experimental data and the location of the maximum value of irradiance is shifted to a higher location. This may be due to the lack of sophisticated models for the species transportation along with combustion and radiation in the continuous zone. Furthermore, the axial temperatures are not predicted well (for any of the boundary conditions) in any of the zones. The present study shows that the existing models are not sufficient enough for modeling blended fuels like diesel. The predictions are strongly dependent on the experimental values of the soot yield. Future experiments are necessary for generalizing the soot yield for different fires. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=burning%20rate" title="burning rate">burning rate</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20accidents" title=" fire accidents"> fire accidents</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20dynamic%20simulator" title=" fire dynamic simulator"> fire dynamic simulator</a>, <a href="https://publications.waset.org/abstracts/search?q=pyrolysis" title=" pyrolysis"> pyrolysis</a> </p> <a href="https://publications.waset.org/abstracts/109038/investigations-on-pyrolysis-model-for-radiatively-dominant-diesel-pool-fire-using-fire-dynamic-simulator" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/109038.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">196</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1028</span> Investigating a Modern Accident Analysis Model for Textile Building Fires through Numerical Reconstruction</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohsin%20Ali%20Shaikh">Mohsin Ali Shaikh</a>, <a href="https://publications.waset.org/abstracts/search?q=Weiguo%20Song"> Weiguo Song</a>, <a href="https://publications.waset.org/abstracts/search?q=Rehmat%20Karim"> Rehmat Karim</a>, <a href="https://publications.waset.org/abstracts/search?q=Muhammad%20Kashan%20Surahio"> Muhammad Kashan Surahio</a>, <a href="https://publications.waset.org/abstracts/search?q=Muhammad%20Usman%20Shahid"> Muhammad Usman Shahid</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Fire investigations face challenges due to the complexity of fire development, and real-world accidents lack repeatability, making it difficult to apply standardized approaches. The unpredictable nature of fires and the unique conditions of each incident contribute to the complexity, requiring innovative methods and tools for effective analysis and reconstruction. This study proposes to provide the modern accident analysis model through numerical reconstruction for fire investigation in textile buildings. This method employs computer simulation to enhance the overall effectiveness of textile-building investigations. The materials and evidence collected from past incidents reconstruct fire occurrences, progressions, and catastrophic processes. The approach is demonstrated through a case study involving a tragic textile factory fire in Karachi, Pakistan, which claimed 257 lives. The reconstruction method proves invaluable for determining fire origins, assessing losses, establishing accountability, and, significantly, providing preventive insights for complex fire incidents. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20investigation" title="fire investigation">fire investigation</a>, <a href="https://publications.waset.org/abstracts/search?q=numerical%20simulation" title=" numerical simulation"> numerical simulation</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20safety" title=" fire safety"> fire safety</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20incident" title=" fire incident"> fire incident</a>, <a href="https://publications.waset.org/abstracts/search?q=textile%20building" title=" textile building"> textile building</a> </p> <a href="https://publications.waset.org/abstracts/177599/investigating-a-modern-accident-analysis-model-for-textile-building-fires-through-numerical-reconstruction" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/177599.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">65</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1027</span> History and Survey on Volunteer Fire Departments in Serbia</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mirjana%20%C4%90.%20Laban">Mirjana Đ. Laban</a>, <a href="https://publications.waset.org/abstracts/search?q=Dragan%20N.%20%C4%90urica"> Dragan N. Đurica</a>, <a href="https://publications.waset.org/abstracts/search?q=Nemanja%20M.%20Erceg"> Nemanja M. Erceg</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Volunteer fire departments (VFD) in Serbia were established as civic associations in XIX Century. The founders and members of the first VFDs were prominent members of local communities. Today, those are volunteer organizations for preventing and extinguishing fires and rescuing people and property in various accidents. The paper presents the results of research about the number and resources of active VFDs done in Autonomous Province of Vojvodina, Serbia and about activities they perform today. The survey was done based on data provided by all registered VFDs in Vojvodina. Firefighters Association of Vojvodina includes 35 municipal firefighting associations, 230 volunteer fire departments with 5,300 active members in qualified fire units and more than 15,000 supporting members. Volunteer involvement is primarily an expression of high moral values and as such it has to be respected and stimulated. Better position of the volunteers would have a major impact on the formation of safety culture concept and general public awareness of fire safety and risk reduction, and therefore the security of the society as a whole. Volunteer fire departments make a significant contribution to educate young people and prevent catastrophic consequences of fires and natural disasters. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=education" title="education">education</a>, <a href="https://publications.waset.org/abstracts/search?q=prevention" title=" prevention"> prevention</a>, <a href="https://publications.waset.org/abstracts/search?q=rescue" title=" rescue"> rescue</a>, <a href="https://publications.waset.org/abstracts/search?q=volunteer%20fire%20departments" title=" volunteer fire departments"> volunteer fire departments</a> </p> <a href="https://publications.waset.org/abstracts/72541/history-and-survey-on-volunteer-fire-departments-in-serbia" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/72541.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">200</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1026</span> Improving Fire Resistance of Wood and Wood-Based Composites and Fire Testing Systems</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Nadir%20Ayrilmis">Nadir Ayrilmis</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Wood and wood-based panels are one of the oldest structural materials used in the construction industry due to their significant advantages such as good mechanical properties, low density, renewable material, low-cost, recycling, etc. However, they burn when exposed to a flame source or high temperatures. This is very important when the wood products are used as structural or hemi-structural materials in the construction industry, furniture industry, so on. For this reason, the fire resistance is demanded property for wood products. They can be impregnated with fire retardants to improve their fire resistance. The most used fire retardants, fire-retardant mechanism, and fire-testing systems, and national and international fire-durability classifications and standard requirements for fire-durability of wood and wood-based panels were given in this study. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20resistance" title="fire resistance">fire resistance</a>, <a href="https://publications.waset.org/abstracts/search?q=wood-based%20panels" title=" wood-based panels"> wood-based panels</a>, <a href="https://publications.waset.org/abstracts/search?q=cone%20calorimeter" title=" cone calorimeter"> cone calorimeter</a>, <a href="https://publications.waset.org/abstracts/search?q=wood" title=" wood"> wood</a> </p> <a href="https://publications.waset.org/abstracts/130377/improving-fire-resistance-of-wood-and-wood-based-composites-and-fire-testing-systems" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/130377.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">165</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1025</span> The Importance of Fire Safety in Egypt</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Omar%20Shakra">Omar Shakra</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper contains a huge number of benefits that we can use it in several places and times in fire safety protection in the Middle East especially in Egypt . People here in Egypt did not consider the safety and fire protection as important as it is. But on the other hand, its very important for them to contain the fire systems and safety in every facility, the companies , hospitals , police stations , and even the super markets must use the fire system. It makes the facility safe to the visitors while they are using it.From my point of view as the owner Fire Safety Company called Deluge Egypt , i can say that not all of the companies use the fire system protection according to the high cost they prefer to build their company without the protection, and this is make the building totally unsafe to be used from the visitors or client.So, i am looking for new methods and technology to invest in Egypt, and this is through attending this Conference and let the audiences know more about the services i provide and [to let them know about the importance of the Fire Safety in Egypt. The Objectives of my research 1- The system that i used in my Company. 2- The benefits of the Fire System Protection. 3-The importance of the Fire System and safety. 4-The use of the new Technologies. 5-The hardships that i found while having new deals with new clients. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire" title="fire">fire</a>, <a href="https://publications.waset.org/abstracts/search?q=system" title=" system"> system</a>, <a href="https://publications.waset.org/abstracts/search?q=protection" title=" protection"> protection</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20hydrants" title=" fire hydrants"> fire hydrants</a>, <a href="https://publications.waset.org/abstracts/search?q=security" title=" security"> security</a>, <a href="https://publications.waset.org/abstracts/search?q=alarms" title=" alarms"> alarms</a> </p> <a href="https://publications.waset.org/abstracts/171993/the-importance-of-fire-safety-in-egypt" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/171993.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">109</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1024</span> Prediction of the Heat Transfer Characteristics of Tunnel Concrete</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Seung%20Cho%20Yang">Seung Cho Yang</a>, <a href="https://publications.waset.org/abstracts/search?q=Jae%20Sung%20Lee"> Jae Sung Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Se%20Hee%20Park"> Se Hee Park</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study suggests the analysis method to predict the damages of tunnel concrete caused by fires. The result obtained from the analyses of concrete temperatures at a fire in a tunnel using ABAQUS was compared with the test result. After the reliability of the analysis method was verified, the temperatures of a tunnel at a real fire and those of concrete during the fire were estimated to predict fire damages. The temperatures inside the tunnel were estimated by FDS, a CFD model. It was deduced that the fire performance of tunnel lining and the fire damages of the structure at an actual fire could be estimated by the analysis method. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20resistance" title="fire resistance">fire resistance</a>, <a href="https://publications.waset.org/abstracts/search?q=heat%20transfer" title=" heat transfer"> heat transfer</a>, <a href="https://publications.waset.org/abstracts/search?q=numerical%20analysis" title=" numerical analysis"> numerical analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=tunnel%20fire" title=" tunnel fire"> tunnel fire</a> </p> <a href="https://publications.waset.org/abstracts/50411/prediction-of-the-heat-transfer-characteristics-of-tunnel-concrete" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/50411.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">437</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1023</span> Numerical Assessment of Fire Characteristics with Bodies Engulfed in Hydrocarbon Pool Fire</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Siva%20Kumar%20Bathina">Siva Kumar Bathina</a>, <a href="https://publications.waset.org/abstracts/search?q=Sudheer%20Siddapureddy"> Sudheer Siddapureddy</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Fires accident becomes even worse when the hazardous equipment like reactors or radioactive waste packages are engulfed in fire. In this work, large-eddy numerical fire simulations are performed using fire dynamic simulator to predict the thermal behavior of such bodies engulfed in hydrocarbon pool fires. A radiatively dominated 0.3 m circular burner with n-heptane as the fuel is considered in this work. The fire numerical simulation results without anybody inside the fire are validated with the reported experimental data. The comparison is in good agreement for different flame properties like predicted mass burning rate, flame height, time-averaged center-line temperature, time-averaged center-line velocity, puffing frequency, the irradiance at the surroundings, and the radiative heat feedback to the pool surface. Cask of different sizes is simulated with SS304L material. The results are independent of the material of the cask simulated as the adiabatic surface temperature concept is employed in this study. It is observed that the mass burning rate increases with the blockage ratio (3% ≤ B ≤ 32%). However, the change in this increment is reduced at higher blockage ratios (B > 14%). This is because the radiative heat feedback to the fuel surface is not only from the flame but also from the cask volume. As B increases, the volume of the cask increases and thereby increases the radiative contribution to the fuel surface. The radiative heat feedback in the case of the cask engulfed in the fire is increased by 2.5% to 31% compared to the fire without cask. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=adiabatic%20surface%20temperature" title="adiabatic surface temperature">adiabatic surface temperature</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20accidents" title=" fire accidents"> fire accidents</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20dynamic%20simulator" title=" fire dynamic simulator"> fire dynamic simulator</a>, <a href="https://publications.waset.org/abstracts/search?q=radiative%20heat%20feedback" title=" radiative heat feedback"> radiative heat feedback</a> </p> <a href="https://publications.waset.org/abstracts/115684/numerical-assessment-of-fire-characteristics-with-bodies-engulfed-in-hydrocarbon-pool-fire" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/115684.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">126</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1022</span> Numerical Study of Fire Propagation in Confined and Open Area</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hadj%20Miloua">Hadj Miloua</a>, <a href="https://publications.waset.org/abstracts/search?q=Abbes%20Azzi"> Abbes Azzi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The objective of the present paper is to understand, predict and modeled the fire behavior in confined and open area in different conditions and diverse fuels such as liquid pool fire and the vegetative materials. The distinctive problems are a ventilated road tunnel used for urban transport, by the characterization installations of ventilation and his influence in the mode of smoke dispersion and the flame shape. A general investigation is relatively traditional, based on the modeling and simulation the scenario of the pool fire interacted with wind ventilation by the use of numerical software fire dynamic simulator FDS ver.5 to simulate the fire in ventilated tunnel. The second simulation by WFDS.5 is Wildland fire which is always occurs in forest and rangeland fire environments and will thus have an impact on people, property and resources. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire" title="fire">fire</a>, <a href="https://publications.waset.org/abstracts/search?q=road%20tunnel" title=" road tunnel"> road tunnel</a>, <a href="https://publications.waset.org/abstracts/search?q=simulation" title=" simulation"> simulation</a>, <a href="https://publications.waset.org/abstracts/search?q=vegetation" title=" vegetation"> vegetation</a>, <a href="https://publications.waset.org/abstracts/search?q=wildland" title=" wildland"> wildland</a> </p> <a href="https://publications.waset.org/abstracts/18967/numerical-study-of-fire-propagation-in-confined-and-open-area" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/18967.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">514</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1021</span> Impact of an Onboard Fire for the Evacuation of a Rolling Stock</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Guillaume%20Craveur">Guillaume Craveur</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study highlights the impact of an onboard fire for the evacuation of a rolling stock. Two fires models are achieved. The first one is a zone model realized with the CFAST software. Then, this fire is imported in a building EXODUS model in order to determine the evacuation time with effects of fire effluents (temperature, smoke opacity, smoke toxicity) on passengers. The second fire is achieved with Fire Dynamics Simulator software. The fire defined is directly imported in the FDS+Evac model which will permit to determine the evacuation time and effects of fire effluents on passengers. These effects will be compared with tenability criteria defined in some standards in order to see if the situation is acceptable. Different power of fire will be underlined to see from what power source the hazard become unacceptable. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20safety%20engineering" title="fire safety engineering">fire safety engineering</a>, <a href="https://publications.waset.org/abstracts/search?q=numerical%20tools" title=" numerical tools"> numerical tools</a>, <a href="https://publications.waset.org/abstracts/search?q=rolling%20stock" title=" rolling stock"> rolling stock</a>, <a href="https://publications.waset.org/abstracts/search?q=evacuation" title=" evacuation"> evacuation</a> </p> <a href="https://publications.waset.org/abstracts/73910/impact-of-an-onboard-fire-for-the-evacuation-of-a-rolling-stock" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/73910.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">201</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1020</span> An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ki%20Ok%20Choi">Ki Ok Choi</a>, <a href="https://publications.waset.org/abstracts/search?q=Sung%20Ho%20Hong"> Sung Ho Hong</a>, <a href="https://publications.waset.org/abstracts/search?q=Dong%20Suck%20Kim"> Dong Suck Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Don%20Mook%20Choi"> Don Mook Choi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Rack type warehouses are different from general buildings in the kinds, amount, and arrangement of stored goods, so the fire risk of rack type warehouses is different from those buildings. The fire pattern of rack type warehouses is different in combustion characteristic and storing condition of stored goods. The initial fire burning rate is different in the surface condition of materials, but the running time of fire is closely related with the kinds of stored materials and stored conditions. The stored goods of the warehouse are consisted of diverse combustibles, combustible liquid, and so on. Fire detection time may be delayed because the residents are less than office and commercial buildings. If fire detectors installed in rack type warehouses are inadaptable, the fire of the warehouse may be the great fire because of delaying of fire detection. In this paper, we studied what kinds of fire detectors are optimized in early detecting of rack type warehouse fire by real-scale fire tests. The fire detectors used in the tests are rate of rise type, fixed type, photo electric type, and aspirating type detectors. We considered optimum fire detecting method in rack type warehouses suggested by the response characteristic and comparative analysis of the fire detectors. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20detector" title="fire detector">fire detector</a>, <a href="https://publications.waset.org/abstracts/search?q=rack" title=" rack"> rack</a>, <a href="https://publications.waset.org/abstracts/search?q=response%20characteristic" title=" response characteristic"> response characteristic</a>, <a href="https://publications.waset.org/abstracts/search?q=warehouse" title=" warehouse"> warehouse</a> </p> <a href="https://publications.waset.org/abstracts/56376/an-experimental-study-on-the-optimum-installation-of-fire-detector-for-early-stage-fire-detecting-in-rack-type-warehouses" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/56376.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">745</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1019</span> Prediction of Fire Growth of the Office by Real-Scale Fire Experiment</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Kweon%20Oh-Sang">Kweon Oh-Sang</a>, <a href="https://publications.waset.org/abstracts/search?q=Kim%20Heung-Youl"> Kim Heung-Youl</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Estimating the engineering properties of fires is important to be prepared for the complex and various fire risks of large-scale structures such as super-tall buildings, large stadiums, and multi-purpose structures. In this study, a mock-up of a compartment which was 2.4(L) x 3.6 (W) x 2.4 (H) meter in dimensions was fabricated at the 10MW LSC (Large Scale Calorimeter) and combustible office supplies were placed in the compartment for a real-scale fire test. Maximum heat release rate was 4.1 MW and total energy release obtained through the application of t2 fire growth rate was 6705.9 MJ. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20growth" title="fire growth">fire growth</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20experiment" title=" fire experiment"> fire experiment</a>, <a href="https://publications.waset.org/abstracts/search?q=t2%20curve" title=" t2 curve"> t2 curve</a>, <a href="https://publications.waset.org/abstracts/search?q=large%20scale%20calorimeter" title=" large scale calorimeter"> large scale calorimeter</a> </p> <a href="https://publications.waset.org/abstracts/50330/prediction-of-fire-growth-of-the-office-by-real-scale-fire-experiment" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/50330.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">338</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1018</span> Human Error Analysis in the USA Marine Accidents Reports</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=J.%20S%C3%A1nchez-Beaskoetxea">J. Sánchez-Beaskoetxea</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The analysis of accidents, such as marine accidents, is one of the most useful instruments to avoid future accidents. In the case of marine accidents, from a simple collision of a small boat in a port to the wreck of a gigantic tanker ship, the study of the causes of the accidents is the basis of a great part of the marine international legislation. Some countries have official institutions who investigate all the accidents in which a ship with their flag is involved. In the case of the USA, the National Transportation Safety Board (NTSB) is responsible for these researches. The NTSB, after a deep investigation into each accident, publishes a Marine Accident Report with the possible cause of the accident. This paper analyses all the Marine Accident Reports published by the NTBS and focuses its attention especially in the Human Errors that led to reported accidents. In this research, the different Human Errors made by crew members are cataloged in 10 different groups. After a complete analysis of all the reports, the statistical analysis on the Human Errors typology in marine accidents is presented in order to use it as a tool to avoid the same errors in the future. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=human%20error" title="human error">human error</a>, <a href="https://publications.waset.org/abstracts/search?q=marine%20accidents" title=" marine accidents"> marine accidents</a>, <a href="https://publications.waset.org/abstracts/search?q=ship%20crew" title=" ship crew"> ship crew</a>, <a href="https://publications.waset.org/abstracts/search?q=USA" title=" USA"> USA</a> </p> <a href="https://publications.waset.org/abstracts/63273/human-error-analysis-in-the-usa-marine-accidents-reports" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/63273.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">418</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1017</span> Investigation of Arson Fire Incident in Textile Garment Building Using Fire Dynamic Simulation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohsin%20Ali%20Shaikh">Mohsin Ali Shaikh</a>, <a href="https://publications.waset.org/abstracts/search?q=Song%20Weiguo"> Song Weiguo</a>, <a href="https://publications.waset.org/abstracts/search?q=Muhammad%20Kashan%20Surahio"> Muhammad Kashan Surahio</a>, <a href="https://publications.waset.org/abstracts/search?q=Usman%20Shahid"> Usman Shahid</a>, <a href="https://publications.waset.org/abstracts/search?q=Rehmat%20Karim"> Rehmat Karim</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study investigated a catastrophic arson fire incident that occurred at a textile garment building in Karachi, Pakistan. Unfortunately, a catastrophic event led to the loss of 262 lives and caused 55 severe injuries. The primary objective is to analyze the aspects of the fire incident and understand the causes of arson fire disasters. The study utilized Fire Dynamic Simulation (F.D.S) was employed to simulate fire propagation, visibility, harmful gas concentration, fire temperature, and numerical results. The analysis report has determined the specific circumstances that created the unpleasant incident in the present study. The significance of the current findings lies in their potential to prevent arson fires, improve fire safety measures, and the development of safety plans in building design. The fire dynamic simulation findings can serve as a theoretical basis for the investigation of arson fires and evacuation planning in textile garment buildings. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=investigation" title="investigation">investigation</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20arson%20incident" title=" fire arson incident"> fire arson incident</a>, <a href="https://publications.waset.org/abstracts/search?q=textile%20garment" title=" textile garment"> textile garment</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20dynamic%20simulation%20%28FDS%29" title=" fire dynamic simulation (FDS)"> fire dynamic simulation (FDS)</a> </p> <a href="https://publications.waset.org/abstracts/175170/investigation-of-arson-fire-incident-in-textile-garment-building-using-fire-dynamic-simulation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/175170.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">90</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1016</span> A Small-Scale Study of Fire Whirls and Investigation of the Effects of Near-Ground Height on the Behavior of Fire Whirls</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Arabghahestani">M. Arabghahestani</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Darwish%20Ahmad"> A. Darwish Ahmad</a>, <a href="https://publications.waset.org/abstracts/search?q=N.%20K.%20Akafuah"> N. K. Akafuah</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this work, small-scale experiments of fire whirl were conducted to study the spinning fire phenomenon and to gain comprehensive understandings of fire tornadoes and the factors that affect their behavior. High speed imaging was used to track the flames at both temporal and spatial scales. This allowed us to better understand the role of the near-ground height in creating a boundary layer flow profile that, in turn contributes to formation of vortices around the fire, and consequent fire whirls. Based on the results obtained from these observations, we were able to spot the differences in the fuel burning rate of the fire itself as a function of a newly defined specific non-dimensional near-ground height. Based on our observations, there is a cutoff non-dimensional height, beyond which a normal fire can be turned into a fire whirl. Additionally, the results showed that the fire burning rate decreases by moving the fire to a height higher than the ground level. These effects were justified by the interactions between vortices formed by, the back pressure and the boundary layer velocity profile, and the vortices generated by the fire itself. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=boundary%20layer%20profile" title="boundary layer profile">boundary layer profile</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20whirls" title=" fire whirls"> fire whirls</a>, <a href="https://publications.waset.org/abstracts/search?q=near-ground%20height" title=" near-ground height"> near-ground height</a>, <a href="https://publications.waset.org/abstracts/search?q=vortex%20interactions" title=" vortex interactions"> vortex interactions</a> </p> <a href="https://publications.waset.org/abstracts/107924/a-small-scale-study-of-fire-whirls-and-investigation-of-the-effects-of-near-ground-height-on-the-behavior-of-fire-whirls" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/107924.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">163</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1015</span> Forest Fire Risk Mapping Using Analytic Hierarchy Process and GIS-Based Application: A Case Study in Hua Sai District, Thailand</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Narissara%20Nuthammachot">Narissara Nuthammachot</a>, <a href="https://publications.waset.org/abstracts/search?q=Dimitris%20Stratoulias"> Dimitris Stratoulias</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Fire is one of the main causes of environmental and ecosystem change. Therefore, it is a challenging task for fire risk assessment fire potential mapping. The study area is Hua Sai district, Nakorn Sri Thammarat province, which covers in a part of peat swamp forest areas. 55 fire points in peat swamp areas were reported from 2012 to 2016. Analytic Hierarchy Process (AHP) and Geographic Information System (GIS) methods were selected for this study. The risk fire area map was arranged on these factors; elevation, slope, aspect, precipitation, distance from the river, distance from town, and land use. The results showed that the predicted fire risk areas are found to be in appreciable reliability with past fire events. The fire risk map can be used for the planning and management of fire areas in the future. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=analytic%20hierarchy%20process" title="analytic hierarchy process">analytic hierarchy process</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20risk%20assessment" title=" fire risk assessment"> fire risk assessment</a>, <a href="https://publications.waset.org/abstracts/search?q=geographic%20information%20system" title=" geographic information system"> geographic information system</a>, <a href="https://publications.waset.org/abstracts/search?q=peat%20swamp%20forest" title=" peat swamp forest"> peat swamp forest</a> </p> <a href="https://publications.waset.org/abstracts/113447/forest-fire-risk-mapping-using-analytic-hierarchy-process-and-gis-based-application-a-case-study-in-hua-sai-district-thailand" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/113447.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">211</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1014</span> A Review on Concrete Structures in Fire</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=S.%20Iffat">S. Iffat</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Bose"> B. Bose</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Concrete as a construction material is versatile because it displays high degree of fire-resistance. Concrete’s inherent ability to combat one of the most devastating disaster that a structure can endure in its lifetime, can be attributed to its constituent materials which make it inert and have relatively poor thermal conductivity. However, concrete structures must be designed for fire effects. Structural components should be able to withstand dead and live loads without undergoing collapse. The properties of high-strength concrete must be weighed against concerns about its fire resistance and susceptibility to spalling at elevated temperatures. In this paper, the causes, effects and some remedy of deterioration in concrete due to fire hazard will be discussed. Some cost effective solutions to produce a fire resistant concrete will be conversed through this paper. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=concrete" title="concrete">concrete</a>, <a href="https://publications.waset.org/abstracts/search?q=fire" title=" fire"> fire</a>, <a href="https://publications.waset.org/abstracts/search?q=spalling" title=" spalling"> spalling</a>, <a href="https://publications.waset.org/abstracts/search?q=temperature" title=" temperature"> temperature</a>, <a href="https://publications.waset.org/abstracts/search?q=compressive%20strength" title=" compressive strength"> compressive strength</a>, <a href="https://publications.waset.org/abstracts/search?q=density" title=" density"> density</a> </p> <a href="https://publications.waset.org/abstracts/41154/a-review-on-concrete-structures-in-fire" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/41154.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">443</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1013</span> Emissivity Analysis of Hot-Dip Galvanized Steel in Fire </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Christian%20Gaigl">Christian Gaigl</a>, <a href="https://publications.waset.org/abstracts/search?q=Martin%20Mensinger"> Martin Mensinger</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Once a fire resistance rating is necessary, it has to be proofed that the load bearing behavior of a steel construction under the exposure of fire still fits the static demands. High costs of passive fire protection, which satisfies the requirements, frequently result in a concrete solution. To optimize these expenses, one method is to determine the critical temperature according to the Eurocode DIN EN 1993-1-2. For this purpose, positive effects of hot-dip galvanized surface layers on the temperature development of steel members in the accidental situation of fire exposure has been investigated. The test results show a significant better heating behavior of hot-dip galvanized steel components compared to normal steel specimen. This leads in many cases to a R30 (30 minutes of ISO-fire) fire protection requirement of unprotected steel members and therefore to an economic added value. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20resistance" title="fire resistance">fire resistance</a>, <a href="https://publications.waset.org/abstracts/search?q=hot-dip%20galvanizing" title=" hot-dip galvanizing"> hot-dip galvanizing</a>, <a href="https://publications.waset.org/abstracts/search?q=steel%20constructions" title=" steel constructions"> steel constructions</a>, <a href="https://publications.waset.org/abstracts/search?q=R30%20requirement" title=" R30 requirement"> R30 requirement</a>, <a href="https://publications.waset.org/abstracts/search?q=emissivity" title=" emissivity"> emissivity</a> </p> <a href="https://publications.waset.org/abstracts/94148/emissivity-analysis-of-hot-dip-galvanized-steel-in-fire" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/94148.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">262</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1012</span> Comparison of Injuries and Accidents Globally and in Finland</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=R.%20P%C3%A4%C3%A4kk%C3%B6nen">R. Pääkkönen</a>, <a href="https://publications.waset.org/abstracts/search?q=L.%20Korpinen"> L. Korpinen</a> </p> <p class="card-text"><strong>Abstract:</strong></p> We tried statistically to determine the biggest risks for accidents and injuries in Finland compared to other countries. We have a very high incidence of domestic falls and accidental poisoning compared to other European countries. On the other side, we have a relatively low number of accidents in traffic or at work globally, and in European scale, because we have worked hard to diminish these forms of accidents. In Finland, there is work to be done to improve attitudes and actions against domestic accidents. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=injuries" title="injuries">injuries</a>, <a href="https://publications.waset.org/abstracts/search?q=accident" title=" accident"> accident</a>, <a href="https://publications.waset.org/abstracts/search?q=comparison" title=" comparison"> comparison</a>, <a href="https://publications.waset.org/abstracts/search?q=Finland" title=" Finland"> Finland</a> </p> <a href="https://publications.waset.org/abstracts/46163/comparison-of-injuries-and-accidents-globally-and-in-finland" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/46163.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">227</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1011</span> Effect of Fire Exposure on the Ultimate Strength of Loaded Columns</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hatem%20Hamdy%20Ghieth">Hatem Hamdy Ghieth</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In the recent time many fires happened in many skeleton buildings. The fire may be continues for a long time. This fire may cause a collapse of the building. This collapse may be happened due to the time of exposure to fire as well as the rate of the loading to the carrying elements. In this research a laboratory study for reinforced concrete columns under effect of fire with temperature reaches (650 ْ C) on the behavior of columns which loaded with axial load and with exposing to fire temperature only from all sides of columns. the main parameters of this study are level of load applying to the column, and the temperature applied to the fire, this temperatures was 500oC and 650oc. Nine concrete columns with dimensions 20x20x100 cms were casted one of these columns was tested to determine the ultimate load while the least were fired according to the experimental schedule. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=columns" title="columns">columns</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20duration" title=" fire duration"> fire duration</a>, <a href="https://publications.waset.org/abstracts/search?q=concrete%20strength" title=" concrete strength"> concrete strength</a>, <a href="https://publications.waset.org/abstracts/search?q=level%20of%20loading" title=" level of loading"> level of loading</a> </p> <a href="https://publications.waset.org/abstracts/19444/effect-of-fire-exposure-on-the-ultimate-strength-of-loaded-columns" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/19444.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">440</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1010</span> Accidental Compartment Fire Dynamics: Experiment, Computational Fluid Dynamics Weakness and Expert Interview Analysis</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Timothy%20Onyenobi">Timothy Onyenobi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Accidental fires and its dynamic as it relates to building compartmentation and the impact of the compartment morphology, is still an on-going area of study; especially with the use of computational fluid dynamics (CFD) modeling methods. With better knowledge on this subject come better solution recommendations by fire engineers. Interviews were carried out for this study where it was identified that the response perspectives to accidental fire were different with the fire engineer providing qualitative data which is based on “what is expected in real fires” and the fire fighters provided information on “what actually obtains in real fires”. This further led to a study and analysis of two real and comprehensively instrumented fire experiments: the Open Plan Office Project by National Institute of Standard and Technology (NIST) USA (to study time to flashover) and the TF2000 project by the Building Research Establishment (BRE) UK (to test for conformity with Building Regulation requirements). The findings from the analysis of the experiments revealed the relative yet critical weakness of fire prediction using a CFD model (usually used by fire engineers) as well as explained the differences in response perspectives of the fire engineers and firefighters from the interview analysis. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=CFD" title="CFD">CFD</a>, <a href="https://publications.waset.org/abstracts/search?q=compartment%20fire" title=" compartment fire"> compartment fire</a>, <a href="https://publications.waset.org/abstracts/search?q=experiment" title=" experiment"> experiment</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20fighters" title=" fire fighters"> fire fighters</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20engineers" title=" fire engineers"> fire engineers</a> </p> <a href="https://publications.waset.org/abstracts/61009/accidental-compartment-fire-dynamics-experiment-computational-fluid-dynamics-weakness-and-expert-interview-analysis" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/61009.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">337</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1009</span> Canada Deuterium Uranium Updated Fire Probabilistic Risk Assessment Model for Canadian Nuclear Plants</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hossam%20Shalabi">Hossam Shalabi</a>, <a href="https://publications.waset.org/abstracts/search?q=George%20Hadjisophocleous"> George Hadjisophocleous</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The Canadian Nuclear Power Plants (NPPs) use some portions of NUREG/CR-6850 in carrying out Fire Probabilistic Risk Assessment (PRA). An assessment for the applicability of NUREG/CR-6850 to CANDU reactors was performed and a CANDU Fire PRA was introduced. There are 19 operating CANDU reactors in Canada at five sites (Bruce A, Bruce B, Darlington, Pickering and Point Lepreau). A fire load density survey was done for all Fire Safe Shutdown Analysis (FSSA) fire zones in all CANDU sites in Canada. National Fire Protection Association (NFPA) Standard 557 proposes that a fire load survey must be conducted by either the weighing method or the inventory method or a combination of both. The combination method results in the most accurate values for fire loads. An updated CANDU Fire PRA model is demonstrated in this paper that includes the fuel survey in all Canadian CANDU stations. A qualitative screening step for the CANDU fire PRA is illustrated in this paper to include any fire events that can damage any part of the emergency power supply in addition to FSSA cables. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20safety" title="fire safety">fire safety</a>, <a href="https://publications.waset.org/abstracts/search?q=CANDU" title=" CANDU"> CANDU</a>, <a href="https://publications.waset.org/abstracts/search?q=nuclear" title=" nuclear"> nuclear</a>, <a href="https://publications.waset.org/abstracts/search?q=fuel%20densities" title=" fuel densities"> fuel densities</a>, <a href="https://publications.waset.org/abstracts/search?q=FDS" title=" FDS"> FDS</a>, <a href="https://publications.waset.org/abstracts/search?q=qualitative%20analysis" title=" qualitative analysis"> qualitative analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20probabilistic%20risk%20assessment" title=" fire probabilistic risk assessment"> fire probabilistic risk assessment</a> </p> <a href="https://publications.waset.org/abstracts/106512/canada-deuterium-uranium-updated-fire-probabilistic-risk-assessment-model-for-canadian-nuclear-plants" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/106512.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">136</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1008</span> Optimizing Fire Suppression Time in Buildings by Forming a Fire Feedback Loop</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Zhdanova%20A.%20O.">Zhdanova A. O.</a>, <a href="https://publications.waset.org/abstracts/search?q=Volkov%20R.%20S."> Volkov R. S.</a>, <a href="https://publications.waset.org/abstracts/search?q=Kuznetsov%20G.%20V."> Kuznetsov G. V.</a>, <a href="https://publications.waset.org/abstracts/search?q=Strizhak%20P.%20A."> Strizhak P. A.</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Fires in different types of facilities are a serious problem worldwide.It is still an unaccomplished science and technology objective to establish the minimum number and type of sensors in automatic systems of compartment fire suppression which would turn the fire-extinguishing agent spraying on and off in real time depending on the state of the fire, minimize the amount of agent applied, delay time in fire suppression and system response, as well as the time of combustion suppression. Based on the results of experimental studies, the conclusion was made that it is reasonable to use a gas analysis system and heat sensors (in the event of their prior activation) to determine the effectiveness of fire suppression (fire-extinguishing composition interacts with the fire). Thus, the concentration of CO in the interaction of the firefighting liquid with the fire increases to 0.7–1.2%, which indicates a slowdown in the flame combustion, and heat sensors stop responding at a gas medium temperature below 80 ºC, which shows a gradual decrease in the heat release from the fire. The evidence from this study suggests that the information received from the video recording equipment (video camera) should be used in real time as an additional parameter confirming fire suppression. Research was supported by Russian Science Foundation (project No 21-19-00009, https://rscf.ru/en/project/21-19-00009/). <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=compartment%20fires" title="compartment fires">compartment fires</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20suppression" title=" fire suppression"> fire suppression</a>, <a href="https://publications.waset.org/abstracts/search?q=continuous%20control%20of%20fire%20behavior" title=" continuous control of fire behavior"> continuous control of fire behavior</a>, <a href="https://publications.waset.org/abstracts/search?q=feedback%20systems" title=" feedback systems"> feedback systems</a> </p> <a href="https://publications.waset.org/abstracts/148653/optimizing-fire-suppression-time-in-buildings-by-forming-a-fire-feedback-loop" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/148653.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">129</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1007</span> The Trend of Injuries in Building Fire in Tehran from 2002 to 2012</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohammadreza%20Ashouri">Mohammadreza Ashouri</a>, <a href="https://publications.waset.org/abstracts/search?q=Majid%20Bayatian"> Majid Bayatian</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Analysis of fire data is a way for the implementation of any plan to improve the level of safety in cities. Such an analysis is able to reveal signs of changes in a given period and can be used as a measure of safety. The information of about 66,341 fires (from 2002 to 2012) released by Tehran Safety Services and Fire-Fighting Organization and data on the population and the number of households provided by Tehran Municipality and the Statistical Yearbook of Iran were extracted. Using the data, the fire changes, the rate of injuries, and mortality rate were determined and analyzed. The rate of injuries and mortality rate of fires per one million population of Tehran were 59.58% and 86.12%, respectively. During the study period, the number of fires and fire stations increased by 104.38% and 102.63%, respectively. Most fires (9.21%) happened in the 4th District of Tehran. The results showed that the recorded fire data have not been systematically planned for fire prevention since one of the ways to reduce injuries caused by fires is to develop a systematic plan for necessary actions in emergency situations. To determine a reliable source for fire prevention, the stages, definitions of working processes and the cause and effect chains should be considered. Therefore, a comprehensive statistical system should be developed for reported and recorded fire data. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20statistics" title="fire statistics">fire statistics</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20analysis" title=" fire analysis"> fire analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=accident%20prevention" title=" accident prevention"> accident prevention</a>, <a href="https://publications.waset.org/abstracts/search?q=Tehran" title=" Tehran"> Tehran</a> </p> <a href="https://publications.waset.org/abstracts/97571/the-trend-of-injuries-in-building-fire-in-tehran-from-2002-to-2012" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/97571.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">184</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1006</span> Blue-Collar Workers’ Accidents and Close Call Situations Connected to the Use of Cell Phones among Finns Aged 18–65</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=L.%20Korpinen">L. Korpinen</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20P%C3%A4%C3%A4kk%C3%B6nen"> R. Pääkkönen</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20Gobba"> F. Gobba</a> </p> <p class="card-text"><strong>Abstract:</strong></p> There has been discussion if the use of mobile phones causes accidents. We studied workers’ accidents and near accidents related to the use of phones. This study is part of a large cross-sectional study that was carried out on 15,000 working-age Finns. We noticed that there were 4–5 times more close call situations than accidents connected to mobile phones and also work related accidents were fewer than leisure related. There are confusing parameters like the use of mobile phones at work, differences in work content between women and men. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=blue-collar%20workers" title="blue-collar workers">blue-collar workers</a>, <a href="https://publications.waset.org/abstracts/search?q=accident" title=" accident"> accident</a>, <a href="https://publications.waset.org/abstracts/search?q=cell%20phone" title=" cell phone"> cell phone</a>, <a href="https://publications.waset.org/abstracts/search?q=close%20call%20situation" title=" close call situation"> close call situation</a> </p> <a href="https://publications.waset.org/abstracts/46166/blue-collar-workers-accidents-and-close-call-situations-connected-to-the-use-of-cell-phones-among-finns-aged-18-65" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/46166.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">250</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1005</span> The Connection between Required Safe Egress Time and Occupant Fire Safety Training</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Christina%20Knorr">Christina Knorr</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Analysis of the evacuation of occupants of a building plays a significant role in Fire Safety Engineering. One of the tools used for the analysis is the concept of the Required Safe Egress Time (RSET). It is generally accepted that RSET is measured from the time the fire ignites until the time that all occupants have evacuated to a safe location. Instructions on how RSET is determined can be found in both the International Fire Engineering Guidelines and, more recently, in the Australian Fire Engineering Guidelines. The guidelines also specify measures that could be applied to reduce the RSET and hence improve the performance of fire-safety measures of a building. Further, it is suggested that the delay period can be reduced through “training programs.” This study examined the overall level of fire-safety awareness among occupants of residential apartment buildings in Australia and investigated the possible effects of fire-safety training on the delay period and, hence, the RSET. A questionnaire, interviews, and an experiment were conducted to collect data about people’s fire-safety knowledge, people’s behaviour and nature, and the duration of activities people are likely to undertake in the event of a fire. The study led to an investigation into the delay and response time approximations and the development of a new equation to incorporate the impact of training into the RSET calculations for the general use of the fire engineering community. Regardless of the RSET, it can be concluded that fire-safety education and training for residents of apartment buildings have a direct impact on improving their behaviour and firefighting equipment usage in a fire incident. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fire%20safety%20engineering" title="fire safety engineering">fire safety engineering</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20safety%20training" title=" fire safety training"> fire safety training</a>, <a href="https://publications.waset.org/abstracts/search?q=occupant%20evacuation%20behaviour" title=" occupant evacuation behaviour"> occupant evacuation behaviour</a>, <a href="https://publications.waset.org/abstracts/search?q=required%20safe%20egress%20time" title=" required safe egress time"> required safe egress time</a> </p> <a href="https://publications.waset.org/abstracts/177752/the-connection-between-required-safe-egress-time-and-occupant-fire-safety-training" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/177752.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">38</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1004</span> A Study on the Failure Modes of Steel Moment Frame in Post-Earthquake Fire Using Coupled Mechanical-Thermal Analysis</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ehsan%20Asgari">Ehsan Asgari</a>, <a href="https://publications.waset.org/abstracts/search?q=Meisam%20Afazeli"> Meisam Afazeli</a>, <a href="https://publications.waset.org/abstracts/search?q=Nezhla%20Attarchian"> Nezhla Attarchian</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Post-earthquake fire is considered as a major threat in seismic areas. After an earthquake, fire is possible in structures. In this research, the effect of post-earthquake fire on steel moment frames with and without fireproofing coating is investigated. For this purpose, finite element method is employed. For the verification of finite element results, the results of an experimental study carried out by previous researchers are used, and the predicted FE results are compared with the test results, and good agreement is observed. After ensuring the accuracy of the predictions of finite element models, the effect of post-earthquake fire on the frames is investigated taking into account the parameters including the presence or absence of fire protection, frame design assumptions, earthquake type and different fire scenario. Ordinary fire and post-earthquake fire effect on the frames is also studied. The plastic hinges induced by earthquake in the structure are determined in the beam to the column connection and in panel zone. These areas should be accurately considered when providing fireproofing coatings. The results of the study show that the occurrence of fire beside corner columns is the most damaging scenario that results in progressive collapse of structure. It was also concluded that the behavior of structure in fire after a strong ground motion is significantly different from that in a normal fire. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=post%20earthquake%20fire" title="post earthquake fire">post earthquake fire</a>, <a href="https://publications.waset.org/abstracts/search?q=moment%20frame" title=" moment frame"> moment frame</a>, <a href="https://publications.waset.org/abstracts/search?q=finite%20element%20simulation" title=" finite element simulation"> finite element simulation</a>, <a href="https://publications.waset.org/abstracts/search?q=coupled%20temperature-displacement%20analysis" title=" coupled temperature-displacement analysis"> coupled temperature-displacement analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=fire%20scenario" title=" fire scenario"> fire scenario</a> </p> <a href="https://publications.waset.org/abstracts/98372/a-study-on-the-failure-modes-of-steel-moment-frame-in-post-earthquake-fire-using-coupled-mechanical-thermal-analysis" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/98372.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">154</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">1003</span> Risks in Forestry Operations, Analysis of Fatal Accidents</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Rino%20Gubiani">Rino Gubiani</a>, <a href="https://publications.waset.org/abstracts/search?q=Gianfranco%20Pergher"> Gianfranco Pergher</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The work focused on the statistical analysis of accidents in the forestry sector (2000-2020) in Friuli-Venezia Giulia region, located in the North-East of Italy. The aim of the work was to analyse the evolution of the casualties throughout time and to evaluate possible improvements in the sector. It was shown that even nowadays the rate of accidents in forestry work is higher compared with all the other sectors, including agriculture; moreover, it was highlighted that some accidents remained present throughout the whole analysed range, such as slipping on the soil, being hit by trees and falling down from the plants. The results showed that an increase in forestry exploitation could even increase the total number of accidents, if advanced technological machines, such as cable cranes, would not implemented, given the fact that there is also a significant number of old people (above 50 years old) working in the sector. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=safety" title="safety">safety</a>, <a href="https://publications.waset.org/abstracts/search?q=forestry%20work" title=" forestry work"> forestry work</a>, <a href="https://publications.waset.org/abstracts/search?q=accidents" title=" accidents"> accidents</a>, <a href="https://publications.waset.org/abstracts/search?q=risk%20analysis" title=" risk analysis"> risk analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=casualties" title=" casualties"> casualties</a>, <a href="https://publications.waset.org/abstracts/search?q=statistical%20analysis" title=" statistical analysis"> statistical analysis</a> </p> <a href="https://publications.waset.org/abstracts/121722/risks-in-forestry-operations-analysis-of-fatal-accidents" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/121722.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">131</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">‹</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=34">34</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=35">35</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=fire%20accidents&page=2" rel="next">›</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">© 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">×</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>