CINXE.COM
Search results for: high voltage
<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: high voltage</title> <meta name="description" content="Search results for: high voltage"> <meta name="keywords" content="high voltage"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="high voltage" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="high voltage"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 20805</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: high voltage</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20805</span> A Study on ESD Protection Circuit Applying Silicon Controlled Rectifier-Based Stack Technology with High Holding Voltage</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hee-Guk%20Chae">Hee-Guk Chae</a>, <a href="https://publications.waset.org/abstracts/search?q=Bo-Bae%20Song"> Bo-Bae Song</a>, <a href="https://publications.waset.org/abstracts/search?q=Kyoung-Il%20Do"> Kyoung-Il Do</a>, <a href="https://publications.waset.org/abstracts/search?q=Jeong-Yun%20Seo"> Jeong-Yun Seo</a>, <a href="https://publications.waset.org/abstracts/search?q=Yong-Seo%20Koo"> Yong-Seo Koo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this study, an improved Electrostatic Discharge (ESD) protection circuit with low trigger voltage and high holding voltage is proposed. ESD has become a serious problem in the semiconductor process because the semiconductor density has become very high these days. Therefore, much research has been done to prevent ESD. The proposed circuit is a stacked structure of the new unit structure combined by the Zener Triggering (SCR ZTSCR) and the High Holding Voltage SCR (HHVSCR). The simulation results show that the proposed circuit has low trigger voltage and high holding voltage. And the stack technology is applied to adjust the various operating voltage. As the results, the holding voltage is 7.7 V for 2-stack and 10.7 V for 3-stack. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=ESD" title="ESD">ESD</a>, <a href="https://publications.waset.org/abstracts/search?q=SCR" title=" SCR"> SCR</a>, <a href="https://publications.waset.org/abstracts/search?q=latch-up" title=" latch-up"> latch-up</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20clamp" title=" power clamp"> power clamp</a>, <a href="https://publications.waset.org/abstracts/search?q=holding%20voltage" title=" holding voltage"> holding voltage</a> </p> <a href="https://publications.waset.org/abstracts/80537/a-study-on-esd-protection-circuit-applying-silicon-controlled-rectifier-based-stack-technology-with-high-holding-voltage" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/80537.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">546</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20804</span> A Silicon Controlled Rectifier-Based ESD Protection Circuit with High Holding Voltage and High Robustness Characteristics</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Kyoung-il%20Do">Kyoung-il Do</a>, <a href="https://publications.waset.org/abstracts/search?q=Byung-seok%20Lee"> Byung-seok Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Hee-guk%20Chae"> Hee-guk Chae</a>, <a href="https://publications.waset.org/abstracts/search?q=Jeong-yun%20Seo%20Yong-seo%20Koo"> Jeong-yun Seo Yong-seo Koo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, a Silicon Controlled Rectifier (SCR)-based Electrostatic Discharge (ESD) protection circuit with high holding voltage and high robustness characteristics is proposed. Unlike conventional SCR, the proposed circuit has low trigger voltage and high holding voltage and provides effective ESD protection with latch-up immunity. In addition, the TCAD simulation results show that the proposed circuit has better electrical characteristics than the conventional SCR. A stack technology was used for voltage-specific applications. Consequentially, the proposed circuit has a trigger voltage of 17.60 V and a holding voltage of 3.64 V. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=ESD" title="ESD">ESD</a>, <a href="https://publications.waset.org/abstracts/search?q=SCR" title=" SCR"> SCR</a>, <a href="https://publications.waset.org/abstracts/search?q=latch-up" title=" latch-up"> latch-up</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20clamp" title=" power clamp"> power clamp</a>, <a href="https://publications.waset.org/abstracts/search?q=holding%20voltage" title=" holding voltage"> holding voltage</a> </p> <a href="https://publications.waset.org/abstracts/89519/a-silicon-controlled-rectifier-based-esd-protection-circuit-with-high-holding-voltage-and-high-robustness-characteristics" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/89519.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">396</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20803</span> High-Quality Flavor of Black Belly Pork under Lightning Corona Discharge Using Tesla Coil for High Voltage Education</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Kyung-Hoon%20Jang">Kyung-Hoon Jang</a>, <a href="https://publications.waset.org/abstracts/search?q=Jae-Hyo%20Park"> Jae-Hyo Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Kwang-Yeop%20Jang"> Kwang-Yeop Jang</a>, <a href="https://publications.waset.org/abstracts/search?q=Dongjin%20Kim"> Dongjin Kim</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The Tesla coil is an electrical resonant transformer circuit designed by inventor Nikola Tesla in 1891. It is used to produce high voltage, low current and high frequency alternating current electricity. Tesla experimented with a number of different configurations consisting of two or sometimes three coupled resonant electric circuits. This paper focuses on development and high voltage education to apply a Tesla coil to cuisine for high quality flavor and taste conditioning as well as high voltage education under 50 kV corona discharge. The result revealed that the velocity of roasted black belly pork by Tesla coil is faster than that of conventional methods such as hot grill and steel plate etc. depending on applied voltage level and applied voltage time. Besides, carbohydrate and crude protein increased, whereas natrium and saccharides significantly decreased after lightning surge by Tesla coil. This idea will be useful in high voltage education and high voltage application. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=corona%20discharge" title="corona discharge">corona discharge</a>, <a href="https://publications.waset.org/abstracts/search?q=Tesla%20coil" title=" Tesla coil"> Tesla coil</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20voltage%20application" title=" high voltage application"> high voltage application</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20voltage%20education" title=" high voltage education"> high voltage education</a> </p> <a href="https://publications.waset.org/abstracts/77120/high-quality-flavor-of-black-belly-pork-under-lightning-corona-discharge-using-tesla-coil-for-high-voltage-education" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/77120.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">328</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20802</span> New Series Input Parallel Output LLC DC/DC Converter with the Input Voltage Balancing Capacitor for the Electric System of Electric Vehicles</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Kang%20Hyun%20Yi">Kang Hyun Yi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents a new parallel output LLC DC/DC converter for electric vehicle. The electric vehicle has two batteries. One is a high voltage battery for the powertrain of the vehicle and the other is a low voltage battery for the vehicle electric system. The low voltage is charged from the high voltage battery and the high voltage input and the high current output DC/DC converter is needed. Therefore, the new LLC converter with the input voltage compensation is proposed for the high voltage input and the low voltage output DC/DC converter. The proposed circuit has two LLC converters with the series input voltage from the battery for the powertrain and the parallel output low battery voltage for the vehicle electric system because the battery voltage for the powertrain and the electric power for the vehicle become high. Also, the input series voltage compensation capacitor is used for balancing the input current in the two LLC converters. The proposed converter has an equal electric stress of the semiconductor parts and the reactive components, high efficiency and good heat dissipation. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electric%20vehicle" title="electric vehicle">electric vehicle</a>, <a href="https://publications.waset.org/abstracts/search?q=LLC%20DC%2FDC%20converter" title=" LLC DC/DC converter"> LLC DC/DC converter</a>, <a href="https://publications.waset.org/abstracts/search?q=input%20voltage%20balancing" title=" input voltage balancing"> input voltage balancing</a>, <a href="https://publications.waset.org/abstracts/search?q=parallel%20output" title=" parallel output"> parallel output</a> </p> <a href="https://publications.waset.org/abstracts/31896/new-series-input-parallel-output-llc-dcdc-converter-with-the-input-voltage-balancing-capacitor-for-the-electric-system-of-electric-vehicles" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/31896.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">1051</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20801</span> SCR-Based Advanced ESD Protection Device for Low Voltage Application</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Bo%20Bae%20Song">Bo Bae Song</a>, <a href="https://publications.waset.org/abstracts/search?q=Byung%20Seok%20Lee"> Byung Seok Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Hyun%20young%20Kim"> Hyun young Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Chung%20Kwang%20Lee"> Chung Kwang Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Yong%20Seo%20Koo"> Yong Seo Koo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper proposed a silicon controller rectifier (SCR) based ESD protection device to protect low voltage ESD for integrated circuit. The proposed ESD protection device has low trigger voltage and high holding voltage compared with conventional SCR-based ESD protection devices. The proposed ESD protection circuit is verified and compared by TCAD simulation. This paper verified effective low voltage ESD characteristics with low trigger voltage of 5.79V and high holding voltage of 3.5V through optimization depending on design variables (D1, D2, D3, and D4). <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=ESD" title="ESD">ESD</a>, <a href="https://publications.waset.org/abstracts/search?q=SCR" title=" SCR"> SCR</a>, <a href="https://publications.waset.org/abstracts/search?q=holding%20voltage" title=" holding voltage"> holding voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=latch-up" title=" latch-up"> latch-up</a> </p> <a href="https://publications.waset.org/abstracts/21774/scr-based-advanced-esd-protection-device-for-low-voltage-application" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/21774.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">575</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20800</span> SCR-Stacking Structure with High Holding Voltage for IO and Power Clamp</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hyun%20Young%20Kim">Hyun Young Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Chung%20Kwang%20Lee"> Chung Kwang Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Han%20Hee%20Cho">Han Hee Cho</a>, <a href="https://publications.waset.org/abstracts/search?q=Sang%20Woon%20Cho"> Sang Woon Cho</a>, <a href="https://publications.waset.org/abstracts/search?q=Yong%20Seo%20Koo"> Yong Seo Koo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, we proposed a novel SCR (Silicon Controlled Rectifier) - based ESD (Electrostatic Discharge) protection device for I/O and power clamp. The proposed device has a higher holding voltage characteristic than conventional SCR. These characteristics enable to have latch-up immunity under normal operating conditions as well as superior full chip ESD protection. The proposed device was analyzed to figure out electrical characteristics and tolerance robustness in term of individual design parameters (D1, D2, D3). They are investigated by using the Synopsys TCAD simulator. As a result of simulation, holding voltage increased with different design parameters. The holding voltage of the proposed device changes from 3.3V to 7.9V. Also, N-Stack structure ESD device with the high holding voltage is proposed. In the simulation results, 2-stack has holding voltage of 6.8V and 3-stack has holding voltage of 10.5V. The simulation results show that holding voltage of stacking structure can be larger than the operation voltage of high-voltage application. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=ESD" title="ESD">ESD</a>, <a href="https://publications.waset.org/abstracts/search?q=SCR" title=" SCR"> SCR</a>, <a href="https://publications.waset.org/abstracts/search?q=holding%20voltage" title=" holding voltage"> holding voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=stack" title=" stack"> stack</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20clamp" title=" power clamp"> power clamp</a> </p> <a href="https://publications.waset.org/abstracts/30148/scr-stacking-structure-with-high-holding-voltage-for-io-and-power-clamp" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/30148.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">557</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20799</span> DC-to-DC Converters for Low-Voltage High-Power Renewable Energy Systems</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Abdar%20Ali">Abdar Ali</a>, <a href="https://publications.waset.org/abstracts/search?q=Rizwan%20Ullah"> Rizwan Ullah</a>, <a href="https://publications.waset.org/abstracts/search?q=Zahid%20Ullah"> Zahid Ullah</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper focuses on the study of DC-to-DC converters, which are suitable for low-voltage high-power applications. The output voltages generated by renewable energy sources such as photovoltaic arrays and fuel cell stacks are generally low and required to be increased to high voltage levels. Development of DC-to-DC converters, which provide high step-up voltage conversion ratios with high efficiencies and low voltage stresses is one of the main issues in the development of renewable energy systems. A procedure for three converters-conventional DC-to-DC converter, interleaved boost converter, and isolated flyback based converter, is illustrated for a given set of specifications. The selection among the converters for the given application is based on the voltage conversion ratio, efficiency, and voltage stresses. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=flyback%20converter" title="flyback converter">flyback converter</a>, <a href="https://publications.waset.org/abstracts/search?q=interleaved%20boost" title=" interleaved boost"> interleaved boost</a>, <a href="https://publications.waset.org/abstracts/search?q=photovoltaic%20array" title=" photovoltaic array"> photovoltaic array</a>, <a href="https://publications.waset.org/abstracts/search?q=fuel%20cell" title=" fuel cell"> fuel cell</a>, <a href="https://publications.waset.org/abstracts/search?q=switch%20stress" title=" switch stress"> switch stress</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20conversion%20ratio" title=" voltage conversion ratio"> voltage conversion ratio</a>, <a href="https://publications.waset.org/abstracts/search?q=renewable%20energy" title=" renewable energy"> renewable energy</a> </p> <a href="https://publications.waset.org/abstracts/32572/dc-to-dc-converters-for-low-voltage-high-power-renewable-energy-systems" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/32572.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">596</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20798</span> Analysis of SCR-Based ESD Protection Circuit on Holding Voltage Characteristics</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Yong%20Seo%20Koo">Yong Seo Koo</a>, <a href="https://publications.waset.org/abstracts/search?q=Jong%20Ho%20Nam"> Jong Ho Nam</a>, <a href="https://publications.waset.org/abstracts/search?q=Yong%20Nam%20Choi"> Yong Nam Choi</a>, <a href="https://publications.waset.org/abstracts/search?q=Dae%20Yeol%20Yoo"> Dae Yeol Yoo</a>, <a href="https://publications.waset.org/abstracts/search?q=Jung%20Woo%20Han"> Jung Woo Han</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents a silicon controller rectifier (SCR) based ESD protection circuit for IC. The proposed ESD protection circuit has low trigger voltage and high holding voltage compared with conventional SCR ESD protection circuit. Electrical characteristics of the proposed ESD protection circuit are simulated and analyzed using TCAD simulator. The proposed ESD protection circuit verified effective low voltage ESD characteristics with low trigger voltage and high holding voltage. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electro-static%20discharge%20%28ESD%29" title="electro-static discharge (ESD)">electro-static discharge (ESD)</a>, <a href="https://publications.waset.org/abstracts/search?q=silicon%20controlled%20rectifier%20%28SCR%29" title=" silicon controlled rectifier (SCR)"> silicon controlled rectifier (SCR)</a>, <a href="https://publications.waset.org/abstracts/search?q=holding%20voltage" title=" holding voltage"> holding voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=protection%20circuit" title=" protection circuit"> protection circuit</a> </p> <a href="https://publications.waset.org/abstracts/9524/analysis-of-scr-based-esd-protection-circuit-on-holding-voltage-characteristics" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/9524.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">379</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20797</span> Fast High Voltage Solid State Switch Using Insulated Gate Bipolar Transistor for Discharge-Pumped Lasers</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Nur%20Syarafina%20Binti%20Othman">Nur Syarafina Binti Othman</a>, <a href="https://publications.waset.org/abstracts/search?q=Tsubasa%20Jindo"> Tsubasa Jindo</a>, <a href="https://publications.waset.org/abstracts/search?q=Makato%20Yamada"> Makato Yamada</a>, <a href="https://publications.waset.org/abstracts/search?q=Miho%20Tsuyama"> Miho Tsuyama</a>, <a href="https://publications.waset.org/abstracts/search?q=Hitoshi%20Nakano"> Hitoshi Nakano</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A novel method to produce a fast high voltage solid states switch using Insulated Gate Bipolar Transistors (IGBTs) is presented for discharge-pumped gas lasers. The IGBTs are connected in series to achieve a high voltage rating. An avalanche transistor is used as the gate driver. The fast pulse generated by the avalanche transistor quickly charges the large input capacitance of the IGBT, resulting in a switch out of a fast high-voltage pulse. The switching characteristic of fast-high voltage solid state switch has been estimated in the multi-stage series-connected IGBT with the applied voltage of several tens of kV. Electrical circuit diagram and the mythology of fast-high voltage solid state switch as well as experimental results obtained are presented. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=high%20voltage" title="high voltage">high voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=IGBT" title=" IGBT"> IGBT</a>, <a href="https://publications.waset.org/abstracts/search?q=solid%20state%20switch" title=" solid state switch"> solid state switch</a>, <a href="https://publications.waset.org/abstracts/search?q=bipolar%20transistor" title=" bipolar transistor"> bipolar transistor</a> </p> <a href="https://publications.waset.org/abstracts/13067/fast-high-voltage-solid-state-switch-using-insulated-gate-bipolar-transistor-for-discharge-pumped-lasers" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/13067.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">552</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20796</span> Breakdown Voltage Measurement of High Voltage Transformers Oils Using an Active Microwave Resonator Sensor</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20A.%20Al-Mudhafar">Ahmed A. Al-Mudhafar</a>, <a href="https://publications.waset.org/abstracts/search?q=Ali%20A.%20Abduljabar"> Ali A. Abduljabar</a>, <a href="https://publications.waset.org/abstracts/search?q=Hayder%20Jawad%20Albattat"> Hayder Jawad Albattat</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This work suggests a new microwave resonator sensor (MRS) device for measuring the oil’s breakdown voltage of high voltage transformers. A precise high-sensitivity sensor is designed and manufactured based on a microstrip split ring resonator (SRR). To improve the sensor sensitivity, a RF amplifier of 30 dB gain is linked through a transmission line of 50Ω.The sensor operates at a microwave band (L) with a quality factor of 1.35x105 when it is loaded with an empty tube. In this work, the sensor has been tested with three samples of high voltage transformer oil of different ages (new, middle, and damaged) where the quality factor differs with each sample. A mathematical model was built to calculate the breakdown voltage of the transformer oils and the accuracy of the results was higher than 90%. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=active%20resonator%20sensor" title="active resonator sensor">active resonator sensor</a>, <a href="https://publications.waset.org/abstracts/search?q=oil%20breakdown%20voltage" title=" oil breakdown voltage"> oil breakdown voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=transformers%20oils" title=" transformers oils"> transformers oils</a>, <a href="https://publications.waset.org/abstracts/search?q=quality%20factor" title=" quality factor"> quality factor</a> </p> <a href="https://publications.waset.org/abstracts/157297/breakdown-voltage-measurement-of-high-voltage-transformers-oils-using-an-active-microwave-resonator-sensor" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/157297.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">269</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20795</span> High-Voltage Resonant Converter with Extreme Load Variation: Design Criteria and Applications</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jose%20A.%20Pomilio">Jose A. Pomilio</a>, <a href="https://publications.waset.org/abstracts/search?q=Olavo%20Bet"> Olavo Bet</a>, <a href="https://publications.waset.org/abstracts/search?q=Mateus%20P.%20Vieira"> Mateus P. Vieira</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The power converter that feeds high-frequency, high-voltage transformers must be carefully designed due to parasitic components, mainly the secondary winding capacitance and the leakage inductance, that introduces resonances in relatively low-frequency range, next to the switching frequency. This paper considers applications in which the load (resistive) has an unpredictable behavior, changing from open to short-circuit condition faster than the output voltage control loop could react. In this context, to avoid over voltage and over current situations, that could damage the converter, the transformer or the load, it is necessary to find an operation point that assure the desired output voltage in spite of the load condition. This can done adjusting the frequency response of the transformer adding an external inductance, together with selecting the switching frequency to get stable output voltage independently of the load. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=high-voltage%20transformer" title="high-voltage transformer">high-voltage transformer</a>, <a href="https://publications.waset.org/abstracts/search?q=resonant%20converter" title=" resonant converter"> resonant converter</a>, <a href="https://publications.waset.org/abstracts/search?q=soft-commutation" title=" soft-commutation"> soft-commutation</a>, <a href="https://publications.waset.org/abstracts/search?q=external%20inductance" title=" external inductance"> external inductance</a> </p> <a href="https://publications.waset.org/abstracts/11524/high-voltage-resonant-converter-with-extreme-load-variation-design-criteria-and-applications" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/11524.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">481</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20794</span> Modular Harmonic Cancellation in a Multiplier High Voltage Direct Current Generator</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ahmad%20Zahran">Ahmad Zahran</a>, <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20Herzallah"> Ahmed Herzallah</a>, <a href="https://publications.waset.org/abstracts/search?q=Ahmad%20Ahmad"> Ahmad Ahmad</a>, <a href="https://publications.waset.org/abstracts/search?q=Mahran%20Quraan"> Mahran Quraan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Generation of high DC voltages is necessary for testing the insulation material of high voltage AC transmission lines with long lengths. The harmonic and ripple contents of the output DC voltage supplied by high voltage DC circuits require the use of costly capacitors to smooth the output voltage after rectification. This paper proposes a new modular multiplier high voltage DC generator with embedded Cockcroft-Walton circuits that achieve a negligible harmonic and ripple contents of the output DC voltage without the need for costly filters to produce a nearly constant output voltage. In this new topology, Cockcroft-Walton modules are connected in series to produce a high DC output voltage. The modules are supplied by low input AC voltage sources that have the same magnitude and frequency and shifted from each other by a certain angle to eliminate the harmonics from the output voltage. The small ripple factor is provided by the smoothing column capacitors and the phase shifted input voltages of the cascaded modules. The constituent harmonics within each module are determined using Fourier analysis. The viability of the proposed DC generator for testing purposes and the effectiveness of the cascaded connection are confirmed by numerical simulations using MATLAB/Simulink. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Cockcroft-Walton%20circuit" title="Cockcroft-Walton circuit">Cockcroft-Walton circuit</a>, <a href="https://publications.waset.org/abstracts/search?q=harmonics" title=" harmonics"> harmonics</a>, <a href="https://publications.waset.org/abstracts/search?q=ripple%20factor" title=" ripple factor"> ripple factor</a>, <a href="https://publications.waset.org/abstracts/search?q=HVDC%20generator" title=" HVDC generator"> HVDC generator</a> </p> <a href="https://publications.waset.org/abstracts/93486/modular-harmonic-cancellation-in-a-multiplier-high-voltage-direct-current-generator" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/93486.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">367</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20793</span> Dielectric Properties in Frequency Domain of Main Insulation System of Printed Circuit Board</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Xize%20Dai">Xize Dai</a>, <a href="https://publications.waset.org/abstracts/search?q=Jian%20Hao"> Jian Hao</a>, <a href="https://publications.waset.org/abstracts/search?q=Claus%20Leth%20Bak"> Claus Leth Bak</a>, <a href="https://publications.waset.org/abstracts/search?q=Gian%20Carlo%20Montanari"> Gian Carlo Montanari</a>, <a href="https://publications.waset.org/abstracts/search?q=Huai%20Wang"> Huai Wang</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Printed Circuit Board (PCB) is a critical component applicable to power electronics systems, especially for high-voltage applications involving several high-voltage and high-frequency SiC/GaN devices. The insulation system of PCB is facing more challenges from high-voltage and high-frequency stress that can alter the dielectric properties. Dielectric properties of the PCB insulation system also determine the electrical field distribution that correlates with intrinsic and extrinsic aging mechanisms. Hence, investigating the dielectric properties in the frequency domain of the PCB insulation system is a must. The paper presents the frequency-dependent, temperature-dependent, and voltage-dependent dielectric properties, permittivity, conductivity, and dielectric loss tangents of PCB insulation systems. The dielectric properties mechanisms associated with frequency, temperature, and voltage are revealed from the design perspective. It can be concluded that the dielectric properties of PCB in the frequency domain show a strong dependence on voltage, frequency, and temperature. The voltage-, frequency-, and temperature-dependent dielectric properties are associated with intrinsic conduction behavior and polarization patterns from the perspective of dielectric theory. The results may provide some reference for the PCB insulation system design in high voltage, high frequency, and high-temperature power electronics applications. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electrical%20insulation%20system" title="electrical insulation system">electrical insulation system</a>, <a href="https://publications.waset.org/abstracts/search?q=dielectric%20properties" title=" dielectric properties"> dielectric properties</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20voltage%20and%20frequency" title=" high voltage and frequency"> high voltage and frequency</a>, <a href="https://publications.waset.org/abstracts/search?q=printed%20circuit%20board" title=" printed circuit board"> printed circuit board</a> </p> <a href="https://publications.waset.org/abstracts/168071/dielectric-properties-in-frequency-domain-of-main-insulation-system-of-printed-circuit-board" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/168071.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">94</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20792</span> Study on Breakdown Voltage Characteristics of Different Types of Oils with Contaminations</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=C.%20Jouhar">C. Jouhar</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Rajesh%20Kamath"> B. Rajesh Kamath</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20K.%20Veeraiah"> M. K. Veeraiah</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Z.%20Kurian"> M. Z. Kurian</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Since long time ago, petroleum-based mineral oils have been used for liquid insulation in high voltage equipments. Mineral oils are widely used as insulation for transmission and distribution power transformers, capacitors and other high voltage equipment. Petroleum-based insulating oils have excellent dielectric properties such as high electric field strength, low dielectric losses and good long-term performance. Due to environmental consideration, an attempt to search the alternate liquid insulation is required. The influence of particles on the voltage breakdown in insulating oil and other liquids has been recognized for many years. Particles influence both AC and DC voltage breakdown in insulating oil. Experiments are conducted under AC voltage. The breakdown process starts with a microscopic bubble, an area of large distance where ions or electrons initiate avalanches. Insulating liquids drive their dielectric strength from the much higher density compare to gases. Experiments are carried out under High Voltage AC (HVAC) in different types of oils namely castor oil, vegetable oil and mineral oil. The Breakdown Voltage (BDV) with presence of moisture and particle contamination in different types of oils is studied. The BDV of vegetable oil is better when compared to other oils without contamination. The BDV of mineral oil is better when compared to other types of oils in presence of contamination. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=breakdown%20voltage" title="breakdown voltage">breakdown voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20voltage%20AC" title=" high voltage AC"> high voltage AC</a>, <a href="https://publications.waset.org/abstracts/search?q=insulating%20oil" title=" insulating oil"> insulating oil</a>, <a href="https://publications.waset.org/abstracts/search?q=oil%20breakdown" title=" oil breakdown"> oil breakdown</a> </p> <a href="https://publications.waset.org/abstracts/52370/study-on-breakdown-voltage-characteristics-of-different-types-of-oils-with-contaminations" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/52370.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">341</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20791</span> Low Trigger Voltage Silicon Controlled Rectifier Stacking Structure with High Holding Voltage for High Voltage Applications</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Kyoung-Il%20Do">Kyoung-Il Do</a>, <a href="https://publications.waset.org/abstracts/search?q=Jun-Geol%20Park"> Jun-Geol Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Hee-Guk%20Chae"> Hee-Guk Chae</a>, <a href="https://publications.waset.org/abstracts/search?q=Jeong-Yun%20Seo"> Jeong-Yun Seo</a>, <a href="https://publications.waset.org/abstracts/search?q=Yong-Seo%20Koo"> Yong-Seo Koo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A SCR stacking structure is proposed to have improved Latch-up immunity. In comparison with conventional SCR (Silicon Controlled Rectifier), the proposed Electrostatic Discharge (ESD) protection circuit has a lower trigger characteristic by using the LVTSCR (Low Voltage Trigger) structure. Also the proposed ESD protection circuit has improved Holding Voltage Characteristic by using N-stack technique. These characteristics enable to have latch-up immunity in operating conditions. The simulations are accomplished by using the Synopsys TCAD. It has a trigger voltage of 8.9V and a holding voltage of 1.8V in a single structure. And when applying the stack technique, 2-stack has the holding voltage of 3.8V and 3-stack has the holding voltage of 5.1 V. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electrostatic%20discharge%20%28ESD%29" title="electrostatic discharge (ESD)">electrostatic discharge (ESD)</a>, <a href="https://publications.waset.org/abstracts/search?q=low%20voltage%20trigger%20silicon%20controlled%20rectifier%20%28LVTSCR%29" title=" low voltage trigger silicon controlled rectifier (LVTSCR)"> low voltage trigger silicon controlled rectifier (LVTSCR)</a>, <a href="https://publications.waset.org/abstracts/search?q=MVTSCR" title=" MVTSCR"> MVTSCR</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20clamp" title=" power clamp"> power clamp</a>, <a href="https://publications.waset.org/abstracts/search?q=silicon%20controlled%20rectifier%20%28SCR%29" title=" silicon controlled rectifier (SCR)"> silicon controlled rectifier (SCR)</a>, <a href="https://publications.waset.org/abstracts/search?q=latch-up" title=" latch-up"> latch-up</a> </p> <a href="https://publications.waset.org/abstracts/73702/low-trigger-voltage-silicon-controlled-rectifier-stacking-structure-with-high-holding-voltage-for-high-voltage-applications" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/73702.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">458</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20790</span> Performance Analysis of Transformerless DC-DC Boost Converter</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Nidhi%20Vijay">Nidhi Vijay</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20K.%20Sharma"> A. K. Sharma</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Many industrial applications require power from dc source. DC-DC boost converters are now being used all over the world for rapid transit system. Although these provide high efficiency, smooth control, fast response and regeneration, conventional DC-DC boost converters are unable to provide high step up voltage gain due to effect of power switches, rectifier diodes and equivalent series resistance of inductor and capacitor. This paper proposes new transformerless dc-dc converters to achieve high step up voltage gain as compared to the conventional converter without an extremely high duty ratio. Only one power stage is used in this converter. Steady-state analysis of voltage gain is discussed in brief. Finally, a comparative analysis is given in order to verify the results. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=MATLAB" title="MATLAB">MATLAB</a>, <a href="https://publications.waset.org/abstracts/search?q=DC-DC%20boost%20converter" title=" DC-DC boost converter"> DC-DC boost converter</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20gain" title=" voltage gain"> voltage gain</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20stress" title=" voltage stress"> voltage stress</a> </p> <a href="https://publications.waset.org/abstracts/12636/performance-analysis-of-transformerless-dc-dc-boost-converter" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/12636.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">430</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20789</span> Proposed Fault Detection Scheme on Low Voltage Distribution Feeders</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Adewusi%20Adeoluwawale">Adewusi Adeoluwawale</a>, <a href="https://publications.waset.org/abstracts/search?q=Oronti%20Iyabosola%20Busola"> Oronti Iyabosola Busola</a>, <a href="https://publications.waset.org/abstracts/search?q=Akinola%20Iretiayo"> Akinola Iretiayo</a>, <a href="https://publications.waset.org/abstracts/search?q=Komolafe%20Olusola%20Aderibigbe"> Komolafe Olusola Aderibigbe</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The complex and radial structure of the low voltage distribution network (415V) makes it vulnerable to faults which are due to system and the environmental related factors. Besides these, the protective scheme employed on the low voltage network which is the fuse cannot be monitored remotely such that in the event of sustained fault, the utility will have to rely solely on the complaint brought by customers for loss of supply and this tends to increase the length of outages. A microcontroller based fault detection scheme is hereby developed to detect low voltage and high voltage fault conditions which are common faults on this network. Voltages below 198V and above 242V on the distribution feeders are classified and detected as low voltage and high voltages respectively. Results shows that the developed scheme produced a good response time in the detection of these faults. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fault%20detection" title="fault detection">fault detection</a>, <a href="https://publications.waset.org/abstracts/search?q=low%20voltage%20distribution%20feeders" title=" low voltage distribution feeders"> low voltage distribution feeders</a>, <a href="https://publications.waset.org/abstracts/search?q=outage%20times" title=" outage times"> outage times</a>, <a href="https://publications.waset.org/abstracts/search?q=sustained%20faults" title=" sustained faults"> sustained faults</a> </p> <a href="https://publications.waset.org/abstracts/8097/proposed-fault-detection-scheme-on-low-voltage-distribution-feeders" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/8097.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">543</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20788</span> UV Enhanced Hydrophilicity of the Anodized Films Formed at Low Current Density and Low Voltage</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Phanawan%20Whangdee">Phanawan Whangdee</a>, <a href="https://publications.waset.org/abstracts/search?q=Tomoaki%20Watanabe"> Tomoaki Watanabe</a>, <a href="https://publications.waset.org/abstracts/search?q=Viritpon%20Srimaneepong"> Viritpon Srimaneepong</a>, <a href="https://publications.waset.org/abstracts/search?q=Dujreutai%20Pongkao%20Kashima"> Dujreutai Pongkao Kashima</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The anodized films formed at high current density or high voltage have been widely prepared for dental implant because it can improve the hydrophilicity to the film. Our attempt is exploring whether low current density and low voltage could enhance the good hydrophilicity to the anodized films or not. Furthermore, UV irradiation would be one of the key factor to enhance their hydrophilicity. The anodized films were performed at low current density of 2 mA/cm2 in 1M H3PO4, 1 mA/cm2 in 1M MCPM and low voltage of 6 V in either 1M H3PO4 or 1M MCPM. All samples were treated with UV for various times up to 24 h. After UV irradiation, the contact angle decreased, the chemical species changed. The Ti 2p and O 1s peaks increased, while the C 1s peak decreased which might be due to removal of hydrocarbon. The functional groups of the films shown as the change of OH groups appeared at wave number 3700 cm-1 and 2900-3000 cm-1, however, the peak of H2O at 1630 cm-1disappeared. It is indicated that UV irradiation might change the stretching modes of OH groups coordinated to surface Ti4+ cation but UV did not affect to the changes in surface morphologies. The surface energies increased after UV irradiation resulting in improving of the hydrophilicity. The anodized films formed at low current density or low voltage after UV irradiation showed a low contact angle as well as the film formed at high current density or high voltage. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hydrophilicity" title="hydrophilicity">hydrophilicity</a>, <a href="https://publications.waset.org/abstracts/search?q=low%20current%20density" title=" low current density"> low current density</a>, <a href="https://publications.waset.org/abstracts/search?q=low%20voltage" title=" low voltage"> low voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=UV%20irradiation" title=" UV irradiation"> UV irradiation</a> </p> <a href="https://publications.waset.org/abstracts/22858/uv-enhanced-hydrophilicity-of-the-anodized-films-formed-at-low-current-density-and-low-voltage" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/22858.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">499</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20787</span> A High Step-Up DC-DC Converter for Renewable Energy System Applications</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sopida%20Vacharasukpo">Sopida Vacharasukpo</a>, <a href="https://publications.waset.org/abstracts/search?q=Sudarat%20Khwan-On"> Sudarat Khwan-On</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper proposes a high step-up DC-DC converter topology for renewable energy system applications. The proposed converter employs only a single power switch instead of using several switches. Compared to the conventional DC-DC step-up converters the higher voltage gain with small output ripples can be achieved by using the proposed high step-up DC-DC converter topology. It can step up the low input voltage (20-50Vdc) generated from the photovoltaic modules to the high output voltage level approximately 600Vdc in order to supply the three-phase inverter fed the three-phase motor drive. In this paper, the operating principle of the proposed converter topology and its control strategy under the continuous conduction mode (CCM) are described. Finally, simulation results are shown to demonstrate the effectiveness of the proposed high step-up DC-DC converter with its control strategy to increase the voltage step-up conversion ratio. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=DC-DC%20converter" title="DC-DC converter">DC-DC converter</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20step-up%20ratio" title=" high step-up ratio"> high step-up ratio</a>, <a href="https://publications.waset.org/abstracts/search?q=renewable%20energy" title=" renewable energy"> renewable energy</a>, <a href="https://publications.waset.org/abstracts/search?q=single%20switch" title=" single switch "> single switch </a> </p> <a href="https://publications.waset.org/abstracts/9443/a-high-step-up-dc-dc-converter-for-renewable-energy-system-applications" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/9443.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">1193</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20786</span> Electrochemical Studies of Si, Si-Ge- and Ge-Air Batteries</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=R.%20C.%20Sharma">R. C. Sharma</a>, <a href="https://publications.waset.org/abstracts/search?q=Rishabh%20Bansal"> Rishabh Bansal</a>, <a href="https://publications.waset.org/abstracts/search?q=Prajwal%20Menon"> Prajwal Menon</a>, <a href="https://publications.waset.org/abstracts/search?q=Manoj%20K.%20Sharma"> Manoj K. Sharma</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Silicon-air battery is highly promising for electric vehicles due to its high theoretical energy density (8470 Whkg⁻¹) and its discharge products are non-toxic. For the first time, pure silicon and germanium powders are used as anode material. Nickel wire meshes embedded with charcoal and manganese dioxide powder as cathode and concentrated potassium hydroxide is used as electrolyte. Voltage-time curves have been presented in this study for pure silicon and germanium powder and 5% and 10% germanium with silicon powder. Silicon powder cell assembly gives a stable voltage of 0.88 V for ~20 minutes while Si-Ge provides cell voltage of 0.80-0.76 V for ~10-12 minutes, and pure germanium cell provides cell voltage 0.80-0.76 V for ~30 minutes. The cell voltage is higher for concentrated (10%) sodium hydroxide solution (1.08 V) and it is stable for ~40 minutes. A sharp decrease in cell voltage beyond 40 min may be due to rapid corrosion. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Silicon-air%20battery" title="Silicon-air battery">Silicon-air battery</a>, <a href="https://publications.waset.org/abstracts/search?q=Germanium-air%20battery" title=" Germanium-air battery"> Germanium-air battery</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage-time%20curve" title=" voltage-time curve"> voltage-time curve</a>, <a href="https://publications.waset.org/abstracts/search?q=open%20circuit%20voltage" title=" open circuit voltage"> open circuit voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=Anodic%20corrosion" title=" Anodic corrosion"> Anodic corrosion</a> </p> <a href="https://publications.waset.org/abstracts/138312/electrochemical-studies-of-si-si-ge-and-ge-air-batteries" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/138312.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">237</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20785</span> The Design of PFM Mode DC-DC Converter with DT-CMOS Switch</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jae-Chang%20Kwak">Jae-Chang Kwak</a>, <a href="https://publications.waset.org/abstracts/search?q=Yong-Seo%20Koo"> Yong-Seo Koo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The high efficiency power management IC (PMIC) with switching device is presented in this paper. PMIC is controlled with PFM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS (DT-CMOS) with low on-resistance is designed to decrease conduction loss. The threshold voltage of DT-CMOS drops as the gate voltage increase, resulting in a much higher current handling capability than standard MOSFET. PFM control circuits consist of a generator, AND gate and comparator. The generator is made to have 1.2MHz oscillation voltage. The DC-DC converter based on PFM control circuit and low on-resistance switching device is presented in this paper. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=DT-CMOS" title="DT-CMOS">DT-CMOS</a>, <a href="https://publications.waset.org/abstracts/search?q=PMIC" title=" PMIC"> PMIC</a>, <a href="https://publications.waset.org/abstracts/search?q=PFM" title=" PFM"> PFM</a>, <a href="https://publications.waset.org/abstracts/search?q=DC-DC%20converter" title=" DC-DC converter"> DC-DC converter</a> </p> <a href="https://publications.waset.org/abstracts/11839/the-design-of-pfm-mode-dc-dc-converter-with-dt-cmos-switch" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/11839.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">451</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20784</span> DG Power Plants Placement and Evaluation of its Effect on Improving Voltage Security Margin in Radial Distribution Networks</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Atabak%20Faramarzpour">Atabak Faramarzpour</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohsen%20Mohammadian"> Mohsen Mohammadian</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this article, we introduce the stability of power system voltage and state DG power plants placement and its effect on improving voltage security margin in radial distribution networks. For this purpose, first, important definitions in voltage stability area such as small and big voltage disturbances, instability, and voltage collapse, and voltage security definitions are stated. Then, according to voltage collapse time, voltage stability is classified and each one's characteristics are stated. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=DG%20power%20plants" title="DG power plants">DG power plants</a>, <a href="https://publications.waset.org/abstracts/search?q=evaluation" title=" evaluation"> evaluation</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20security" title=" voltage security"> voltage security</a>, <a href="https://publications.waset.org/abstracts/search?q=radial%20distribution%20networks" title=" radial distribution networks"> radial distribution networks</a> </p> <a href="https://publications.waset.org/abstracts/25147/dg-power-plants-placement-and-evaluation-of-its-effect-on-improving-voltage-security-margin-in-radial-distribution-networks" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/25147.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">670</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20783</span> A Continuous Switching Technique for a Single Phase Bridgeless and Transformer-Less Active Rectifier with High Power Factor and Voltage Stabilization</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Rahul%20Ganpat%20Mapari">Rahul Ganpat Mapari</a>, <a href="https://publications.waset.org/abstracts/search?q=D.%20G.%20Wakde"> D. G. Wakde</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, a proposed approach to improve the power factor of single-phase rectifiers and to regulate the output voltage against the change in grid voltage and load is presented. This converter topology is evaluated on the basis of performance and its salient features like simplicity, low cost and high performance are discussed to analyze its applicability. The proposed control strategy is bridgeless, transformer-less and output current sensor-less and consists of only two Bi-directional IGBTs and two diodes. The voltage regulation is achieved by a simple voltage divider to communicate to a controller to control the duty cycles of PWM. A control technique and operational procedure are also developed, both theoretically and experimentally. The experimental results clearly verify the theoretical analysis from the prototype connected to grid unity. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Active%20Rectifier%20%28AC-DC%29" title="Active Rectifier (AC-DC)">Active Rectifier (AC-DC)</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20factor" title=" power factor"> power factor</a>, <a href="https://publications.waset.org/abstracts/search?q=single%20phase" title=" single phase"> single phase</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20regulation" title=" voltage regulation"> voltage regulation</a> </p> <a href="https://publications.waset.org/abstracts/3045/a-continuous-switching-technique-for-a-single-phase-bridgeless-and-transformer-less-active-rectifier-with-high-power-factor-and-voltage-stabilization" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/3045.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">580</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20782</span> Detection of Voltage Sag and Voltage Swell in Power Quality Using Wavelet Transforms</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Nor%20Asrina%20Binti%20Ramlee">Nor Asrina Binti Ramlee</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Voltage sag, voltage swell, high-frequency noise and voltage transients are kinds of disturbances in power quality. They are also known as power quality events. Equipment used in the industry nowadays has become more sensitive to these events with the increasing complexity of equipment. This leads to the importance of distributing clean power quality to the consumer. To provide better service, the best analysis on power quality is very vital. Thus, this paper presents the events detection focusing on voltage sag and swell. The method is developed by applying time domain signal analysis using wavelet transform approach in MATLAB. Four types of mother wavelet namely Haar, Dmey, Daubechies, and Symlet are used to detect the events. This project analyzed real interrupted signal obtained from 22 kV transmission line in Skudai, Johor Bahru, Malaysia. The signals will be decomposed through the wavelet mothers. The best mother is the one that is capable to detect the time location of the event accurately. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title="power quality">power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20sag" title=" voltage sag"> voltage sag</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20swell" title=" voltage swell"> voltage swell</a>, <a href="https://publications.waset.org/abstracts/search?q=wavelet%20transform" title=" wavelet transform"> wavelet transform</a> </p> <a href="https://publications.waset.org/abstracts/68643/detection-of-voltage-sag-and-voltage-swell-in-power-quality-using-wavelet-transforms" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/68643.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">372</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20781</span> High Precision 65nm CMOS Rectifier for Energy Harvesting using Threshold Voltage Minimization in Telemedicine Embedded System</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hafez%20Fouad">Hafez Fouad</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Telemedicine applications have very low voltage which required High Precision Rectifier Design with high Sensitivity to operate at minimum input Voltage. In this work, we targeted 0.2V input voltage using 65 nm CMOS rectifier for Energy Harvesting Telemedicine application. The proposed rectifier which designed at 2.4GHz using two-stage structure found to perform in a better case where minimum operation voltage is lower than previous published paper and the rectifier can work at a wide range of low input voltage amplitude. The Performance Summary of Full-wave fully gate cross-coupled rectifiers (FWFR) CMOS Rectifier at F = 2.4 GHz: The minimum and maximum output voltages generated using an input voltage amplitude of 2 V are 490.9 mV and 1.997 V, maximum VCE = 99.85 % and maximum PCE = 46.86 %. The Performance Summary of Differential drive CMOS rectifier with external bootstrapping circuit rectifier at F = 2.4 GHz: The minimum and maximum output voltages generated using an input voltage amplitude of 2V are 265.5 mV (0.265V) and 1.467 V respectively, maximum VCE = 93.9 % and maximum PCE= 15.8 %. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=energy%20harvesting" title="energy harvesting">energy harvesting</a>, <a href="https://publications.waset.org/abstracts/search?q=embedded%20system" title=" embedded system"> embedded system</a>, <a href="https://publications.waset.org/abstracts/search?q=IoT%20telemedicine%20system" title=" IoT telemedicine system"> IoT telemedicine system</a>, <a href="https://publications.waset.org/abstracts/search?q=threshold%20voltage%20minimization" title=" threshold voltage minimization"> threshold voltage minimization</a>, <a href="https://publications.waset.org/abstracts/search?q=differential%20drive%20cmos%20rectifier" title=" differential drive cmos rectifier"> differential drive cmos rectifier</a>, <a href="https://publications.waset.org/abstracts/search?q=full-wave%20fully%20gate%20cross-coupled%20rectifiers%20CMOS%20rectifier" title=" full-wave fully gate cross-coupled rectifiers CMOS rectifier"> full-wave fully gate cross-coupled rectifiers CMOS rectifier</a> </p> <a href="https://publications.waset.org/abstracts/150296/high-precision-65nm-cmos-rectifier-for-energy-harvesting-using-threshold-voltage-minimization-in-telemedicine-embedded-system" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/150296.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">162</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20780</span> Ultra-High Voltage Energization of Electrostatic Precipitators for Coal Fired Boilers</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mads%20Kirk%20Larsen">Mads Kirk Larsen</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Strict air pollution control is today high on the agenda world-wide. By reducing the particular emission, not only the mg/Nm3 will be reduced – also parts of mercury and other hazardous matters attached to the particles will be reduced. Furthermore, it is possible to catch the fine particles (PM2.5). For particulate control, the precipitators are still the preferred choice and much efforts have been done to improve the efficiencies. Many ESP’s have seen electrical upgrading by changing the traditional 1 phase power system into either 3 phase or SMPS (High Frequency) units. However, there exist a 4th type of power supply – the pulse type. This is unfortunately widely unknown, but may be of great benefit to power plants. The FLSmidth type is called COROMAX® and it is a high voltage pulse generator for precipitators using a semiconductor switch operating at medium potential. The generated high voltage pulses have rated amplitude of 80 kV and duration of 75 μs and are superimposed on a variable base voltage of 60 kV rated voltage. Hereby, achieving a peak voltage of 140 kV. COROMAX® has the ability to increase the voltage beyond the natural spark limit inside the precipitator. Voltage levels may often be twice as high after installation of COROMAX®. Hereby also the migration velocity increases and thereby the efficiency. As the collection efficiency is proportional to the voltage peak and mean values, this also increases the collection efficiency of the fine particles where test has shown 80% removal of particles less than 0.07 micron. Another great advantage is the indifference to back-corona. Simultaneously with emission reduction, the power consumption will also be reduced. Another great advantage of the COROMAX® system is that the emission can be improved without the need to change the internal parts or enlarge the ESP. Recently, more than 150 units have been installed in China, where emissions have been reduced to ultra-low levels. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=eleectrostatic%20precipitator" title="eleectrostatic precipitator">eleectrostatic precipitator</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20resistivity%20dust" title=" high resistivity dust"> high resistivity dust</a>, <a href="https://publications.waset.org/abstracts/search?q=micropulse%20energization" title=" micropulse energization"> micropulse energization</a>, <a href="https://publications.waset.org/abstracts/search?q=particulate%20removal" title=" particulate removal"> particulate removal</a> </p> <a href="https://publications.waset.org/abstracts/63153/ultra-high-voltage-energization-of-electrostatic-precipitators-for-coal-fired-boilers" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/63153.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">300</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20779</span> A Study on Unidirectional Analog Output Voltage Inverter for Capacitive Load</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sun-Ki%20Hong">Sun-Ki Hong</a>, <a href="https://publications.waset.org/abstracts/search?q=Nam-HeeByeon"> Nam-HeeByeon</a>, <a href="https://publications.waset.org/abstracts/search?q=Jung-Seop%20Lee"> Jung-Seop Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Tae-Sam%20Kang"> Tae-Sam Kang</a> </p> <p class="card-text"><strong>Abstract:</strong></p> For Common R or R-L load to apply arbitrary voltage, the bridge traditional inverters don’t have any difficulties by PWM method. However for driving some piezoelectric actuator, arbitrary voltage not a pulse but a steady voltage should be applied. Piezoelectric load is considered as R-C load and its voltage does not decrease even though the applied voltage decreases. Therefore it needs some special inverter with circuit that can discharge the capacitive energy. Especially for unidirectional arbitrary voltage driving like as sine wave, it becomes more difficult problem. In this paper, a charge and discharge circuit for unidirectional arbitrary voltage driving for piezoelectric actuator is proposed. The circuit has charging and discharging switches for increasing and decreasing output voltage. With the proposed simple circuit, the load voltage can have any unidirectional level with tens of bandwidth because the load voltage can be adjusted by switching the charging and discharging switch appropriately. The appropriateness is proved from the simulation of the proposed circuit. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=DC-DC%20converter" title="DC-DC converter">DC-DC converter</a>, <a href="https://publications.waset.org/abstracts/search?q=analog%20output%20voltage" title=" analog output voltage"> analog output voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=sinusoidal%20drive" title=" sinusoidal drive"> sinusoidal drive</a>, <a href="https://publications.waset.org/abstracts/search?q=piezoelectric%20load" title=" piezoelectric load"> piezoelectric load</a>, <a href="https://publications.waset.org/abstracts/search?q=discharging%20circuit" title=" discharging circuit "> discharging circuit </a> </p> <a href="https://publications.waset.org/abstracts/8464/a-study-on-unidirectional-analog-output-voltage-inverter-for-capacitive-load" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/8464.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">380</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20778</span> High Voltage Magnetic Pulse Generation Using Capacitor Discharge Technique</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20Adel%20Abdallah">Mohamed Adel Abdallah</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A high voltage magnetic pulse is designed by applying an electrical pulse to the coil. Capacitor banks are developed to generate a pulse current. Switching circuit consisting of DPDT switches, thyristor, and triggering circuit is built and tested. The coil current is measured using a Hall-effect current sensor. The magnetic pulse created is measured and tabulated in the graph. Simulation using FEMM is done to compare the results obtained between experiment and simulation. This technology can be applied to area such as medical equipment, measuring instrument, and military equipment. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=high%20voltage" title="high voltage">high voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=magnetic%20pulse" title=" magnetic pulse"> magnetic pulse</a>, <a href="https://publications.waset.org/abstracts/search?q=capacitor%20discharge" title=" capacitor discharge"> capacitor discharge</a>, <a href="https://publications.waset.org/abstracts/search?q=coil" title=" coil"> coil</a> </p> <a href="https://publications.waset.org/abstracts/18438/high-voltage-magnetic-pulse-generation-using-capacitor-discharge-technique" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/18438.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">680</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20777</span> A CMOS-Integrated Hall Plate with High Sensitivity</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Jin%20Sup%20Kim">Jin Sup Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Min%20Seo"> Min Seo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> An improved cross-shaped hall plate with high sensitivity is described in this paper. Among different geometries that have been simulated and measured using Helmholtz coil. The paper describes the physical hall plate design and implementation in a 0.18-µm CMOS technology. In this paper, the biasing is a constant voltage mode. In the voltage mode, magnetic field is converted into an output voltage. The output voltage is typically in the order of micro- to millivolt and therefore, it must be amplified before being transmitted to the outside world. The study, design and performance optimization of hall plate has been carried out with the COMSOL Multiphysics. It is used to estimate the voltage distribution in the hall plate with and without magnetic field and to optimize the geometry. The simulation uses the nominal bias current of 1mA. The applied magnetic field is in the range from 0 mT to 20 mT. Measured results of the one structure over the 10 available samples show for the best sensitivity of 2.5 %/T at 20mT. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=cross-shaped%20hall%20plate" title="cross-shaped hall plate">cross-shaped hall plate</a>, <a href="https://publications.waset.org/abstracts/search?q=sensitivity" title=" sensitivity"> sensitivity</a>, <a href="https://publications.waset.org/abstracts/search?q=CMOS%20technology" title=" CMOS technology"> CMOS technology</a>, <a href="https://publications.waset.org/abstracts/search?q=Helmholtz%20coil" title=" Helmholtz coil"> Helmholtz coil</a> </p> <a href="https://publications.waset.org/abstracts/79041/a-cmos-integrated-hall-plate-with-high-sensitivity" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/79041.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">197</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20776</span> Modeling and Minimizing the Effects of Ferroresonance for Medium Voltage Transformers</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohammad%20Hossein%20Mohammadi%20Sanjani">Mohammad Hossein Mohammadi Sanjani</a>, <a href="https://publications.waset.org/abstracts/search?q=Ashknaz%20Oraee"> Ashknaz Oraee</a>, <a href="https://publications.waset.org/abstracts/search?q=Arian%20Amirnia"> Arian Amirnia</a>, <a href="https://publications.waset.org/abstracts/search?q=Atena%20Taheri"> Atena Taheri</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohammadreza%20Arabi"> Mohammadreza Arabi</a>, <a href="https://publications.waset.org/abstracts/search?q=Mahmud%20Fotuhi-Firuzabad"> Mahmud Fotuhi-Firuzabad</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Ferroresonance effects cause overvoltage in medium voltage transformers and isolators used in electrical networks. Ferroresonance effects are nonlinear and occur between the network capacitor and the nonlinear inductance of the voltage transformer during saturation. This phenomenon is unwanted for transformers since it causes overheating, introduction of high dynamic forces in primary coils, and rise of voltage in primary coils for the voltage transformer. Furthermore, it results in electrical and thermal failure of the transformer. Expansion of distribution lines, design of the transformer in smaller sizes, and the increase of harmonics in distribution networks result in an increase of ferroresonance. There is limited literature available to improve the effects of ferroresonance; therefore, optimizing its effects for voltage transformers is of great importance. In this study, comprehensive modeling of a medium voltage block-type voltage transformer is performed. In addition, a recent model is proposed to improve the performance of voltage transformers during the occurrence of ferroresonance using damping oscillations. Also, transformer design optimization is presented in this study to show further improvements in the performance of the voltage transformer. The recently proposed model is experimentally tested and verified on a medium voltage transformer in the laboratory, and simulation results show a large reduction of the effects of ferroresonance. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=optimization" title="optimization">optimization</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20transformer" title=" voltage transformer"> voltage transformer</a>, <a href="https://publications.waset.org/abstracts/search?q=ferroresonance" title=" ferroresonance"> ferroresonance</a>, <a href="https://publications.waset.org/abstracts/search?q=modeling" title=" modeling"> modeling</a>, <a href="https://publications.waset.org/abstracts/search?q=damper" title=" damper"> damper</a> </p> <a href="https://publications.waset.org/abstracts/169686/modeling-and-minimizing-the-effects-of-ferroresonance-for-medium-voltage-transformers" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/169686.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">101</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">‹</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=693">693</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=694">694</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=high%20voltage&page=2" rel="next">›</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">© 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">×</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>