CINXE.COM

Search results for: shunt active power filter

<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: shunt active power filter</title> <meta name="description" content="Search results for: shunt active power filter"> <meta name="keywords" content="shunt active power filter"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="shunt active power filter" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="shunt active power filter"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 10171</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: shunt active power filter</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10171</span> Power Quality Improvement Using Interval Type-2 Fuzzy Logic Controller for Five-Level Shunt Active Power Filter</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Yousfi%20Abdelkader">Yousfi Abdelkader</a>, <a href="https://publications.waset.org/abstracts/search?q=Chaker%20Abdelkader"> Chaker Abdelkader</a>, <a href="https://publications.waset.org/abstracts/search?q=Bot%20Youcef"> Bot Youcef</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This article proposes a five-level shunt active power filter for power quality improvement using a interval type-2 fuzzy logic controller (IT2 FLC). The reference compensating current is extracted using the P-Q theory. The majority of works previously reported are based on two-level inverters with a conventional Proportional integral (PI) controller, which requires rigorous mathematical modeling of the system. In this paper, a IT2 FLC controlled five-level active power filter is proposed to overcome the problem associated with PI controller. The IT2 FLC algorithm is applied for controlling the DC-side capacitor voltage as well as the harmonic currents of the five-level active power filter. The active power filter with a IT2 FLC is simulated in MATLAB Simulink environment. The simulated response shows that the proposed shunt active power filter controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the source voltage. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title="power quality">power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter" title=" shunt active power filter"> shunt active power filter</a>, <a href="https://publications.waset.org/abstracts/search?q=interval%20type-2%20fuzzy%20logic%20controller%20%28T2FL%29" title=" interval type-2 fuzzy logic controller (T2FL)"> interval type-2 fuzzy logic controller (T2FL)</a>, <a href="https://publications.waset.org/abstracts/search?q=multilevel%20inverter" title=" multilevel inverter"> multilevel inverter</a> </p> <a href="https://publications.waset.org/abstracts/117014/power-quality-improvement-using-interval-type-2-fuzzy-logic-controller-for-five-level-shunt-active-power-filter" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/117014.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">178</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10170</span> Using Power Flow Analysis for Understanding UPQC鈥檚 Behaviors</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=O.%20Abdelkhalek">O. Abdelkhalek</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Naimi"> A. Naimi</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Rami"> M. Rami</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20N.%20Tandjaoui"> M. N. Tandjaoui</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Kechich"> A. Kechich</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper deals with the active and reactive power flow analysis inside the unified power quality conditioner (UPQC) during several cases. The UPQC is a combination of shunt and series active power filter (APF). It is one of the best solutions towards the mitigation of voltage sags and swells problems on distribution network. This analysis can provide the helpful information to well understanding the interaction between the series filter, the shunt filter, the DC bus link and electrical network. The mathematical analysis is based on active and reactive power flow through the shunt and series active power filter. Wherein series APF can absorb or deliver the active power to mitigate a swell or sage voltage where in the both cases it absorbs a small reactive power quantity whereas the shunt active power absorbs or releases the active power for stabilizing the storage capacitor鈥檚 voltage as well as the power factor correction. The voltage sag and voltage swell are usually interpreted through the DC bus voltage curves. These two phenomena are introduced in this paper with a new interpretation based on the active and reactive power flow analysis inside the UPQC. For simplifying this study, a linear load is supposed in this digital simulation. The simulation results are carried out to confirm the analysis done. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=UPQC" title="UPQC">UPQC</a>, <a href="https://publications.waset.org/abstracts/search?q=Power%20flow%20analysis" title=" Power flow analysis"> Power flow analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=shunt%20filter" title=" shunt filter"> shunt filter</a>, <a href="https://publications.waset.org/abstracts/search?q=series%20filter." title=" series filter."> series filter.</a> </p> <a href="https://publications.waset.org/abstracts/21038/using-power-flow-analysis-for-understanding-upqcs-behaviors" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/21038.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">572</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10169</span> Self-Tuning-Filter and Fuzzy Logic Control for Shunt Active Power Filter</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Kaddari%20Faiza">Kaddari Faiza</a>, <a href="https://publications.waset.org/abstracts/search?q=Mazari%20Benyounes"> Mazari Benyounes</a>, <a href="https://publications.waset.org/abstracts/search?q=Mihoub%20Youcef"> Mihoub Youcef</a>, <a href="https://publications.waset.org/abstracts/search?q=Safa%20Ahmed"> Safa Ahmed</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Active filtering of electric power has now become a mature technology for reactive power and harmonic compensation caused by the proliferation of power electronics devices used for industrial, commercial and residential purposes. The aim of this study is to enhance the power quality by improving the performances of shunt active power filter in harmonic mitigation to obtain sinusoidal source currents with very weak ripples. A power circuit configuration and control scheme for shunt active power filter are described with an improved method for harmonics compensation using self-tuning-filter for harmonics identification and fuzzy logic control to generate reference current. Simulation results (using MATLAB/SIMULINK) illustrates the compensation characteristics of the proposed control strategy. Analysis of these results proves the feasibility and effectiveness of this method to improve the power quality and also show the performances of fuzzy logic control which provides flexibility, high precision and fast response. The total harmonic distortion (THD %) for the simulations found to be within the recommended imposed IEEE 519-1992 harmonic standard. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Active%20Powers%20Filter%20%28APF%29" title="Active Powers Filter (APF)">Active Powers Filter (APF)</a>, <a href="https://publications.waset.org/abstracts/search?q=Self-Tuning-Filter%20%28STF%29" title=" Self-Tuning-Filter (STF)"> Self-Tuning-Filter (STF)</a>, <a href="https://publications.waset.org/abstracts/search?q=fuzzy%20logic%20control" title=" fuzzy logic control"> fuzzy logic control</a>, <a href="https://publications.waset.org/abstracts/search?q=hysteresis-band%20control" title=" hysteresis-band control "> hysteresis-band control </a> </p> <a href="https://publications.waset.org/abstracts/21684/self-tuning-filter-and-fuzzy-logic-control-for-shunt-active-power-filter" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/21684.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">739</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10168</span> A Three Phase Shunt Active Power Filter for Currents Harmonics Elimination and Reactive Power Compensation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Amar%20Omeiri">Amar Omeiri</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents a three-phase shunt active power filter for current harmonics suppression and reactive power compensation using the supply current as reference. The proposed APF has a simple control circuit; it consists of detecting the supply current instead of the load current. The advantages of this APF are simplicity of control circuits and low implementation cost. The simulation results show that the proposed APF can compensate the reactive power and suppress current harmonics with two types of non-linear loads. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=active%20power%20filter" title="active power filter">active power filter</a>, <a href="https://publications.waset.org/abstracts/search?q=current%20harmonics%20and%20reactive%20power%20compensation" title=" current harmonics and reactive power compensation"> current harmonics and reactive power compensation</a>, <a href="https://publications.waset.org/abstracts/search?q=PWM%20inverter" title=" PWM inverter"> PWM inverter</a>, <a href="https://publications.waset.org/abstracts/search?q=Total%20Harmonic%20Distortion" title=" Total Harmonic Distortion"> Total Harmonic Distortion</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title=" power quality"> power quality</a> </p> <a href="https://publications.waset.org/abstracts/23921/a-three-phase-shunt-active-power-filter-for-currents-harmonics-elimination-and-reactive-power-compensation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/23921.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">588</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10167</span> Renewable Energy Interfaced Shunt Active Filter Using a Virtual Flux Direct Power Control</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20R.%20Bengourina">M. R. Bengourina</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Rahli"> M. Rahli</a>, <a href="https://publications.waset.org/abstracts/search?q=L.%20Hassaine"> L. Hassaine</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20Saadi"> S. Saadi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this study, we present a control method entitled virtual flux direct power control of a grid connected photovoltaic system associated with an active power filter. The virtual flux direct control of power (VF-DPC) is employed for the calculation of reference current generation. In this technique, the switches states of inverter are selected from a table of switching based on the immediate errors between the active and reactive powers and their reference values. The objectives of this paper are the reduction of Total Harmonic Distortion (THD) of source current, compensating reactive power and injecting the maximum active power available from the PV array into the load and/or grid. MATLAB/SIMULINK simulations are provided to demonstrate the performance of the proposed approach. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter" title="shunt active power filter">shunt active power filter</a>, <a href="https://publications.waset.org/abstracts/search?q=VF-DPC" title=" VF-DPC"> VF-DPC</a>, <a href="https://publications.waset.org/abstracts/search?q=photovoltaic" title=" photovoltaic"> photovoltaic</a>, <a href="https://publications.waset.org/abstracts/search?q=MPPT" title=" MPPT"> MPPT</a> </p> <a href="https://publications.waset.org/abstracts/74510/renewable-energy-interfaced-shunt-active-filter-using-a-virtual-flux-direct-power-control" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/74510.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">323</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10166</span> Optimal Injected Current Control for Shunt Active Power Filter Using Artificial Intelligence</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Brahim%20Berbaoui">Brahim Berbaoui</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, a new particle swarm optimization (PSO) based method is proposed for the implantation of optimal harmonic power flow in power systems. In this algorithm approach, proportional integral controller for reference compensating currents of active power filter is performed in order to minimize the total harmonic distortion (THD). The simulation results show that the new control method using PSO approach is not only easy to be implanted, but also very effective in reducing the unwanted harmonics and compensating reactive power. The studies carried out have been accomplished using the MATLAB Simulink Power System Toolbox. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter" title="shunt active power filter">shunt active power filter</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title=" power quality"> power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=current%20control" title=" current control"> current control</a>, <a href="https://publications.waset.org/abstracts/search?q=proportional%20integral%20controller" title=" proportional integral controller"> proportional integral controller</a>, <a href="https://publications.waset.org/abstracts/search?q=particle%20swarm%20optimization" title=" particle swarm optimization "> particle swarm optimization </a> </p> <a href="https://publications.waset.org/abstracts/19698/optimal-injected-current-control-for-shunt-active-power-filter-using-artificial-intelligence" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/19698.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">616</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10165</span> Nine-Level Shunt Active Power Filter Associated with a Photovoltaic Array Coupled to the Electrical Distribution Network</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Zahzouh%20Zoubir">Zahzouh Zoubir</a>, <a href="https://publications.waset.org/abstracts/search?q=Bouzaouit%20Azzeddine"> Bouzaouit Azzeddine</a>, <a href="https://publications.waset.org/abstracts/search?q=Gahgah%20Mounir"> Gahgah Mounir</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The use of more and more electronic power switches with a nonlinear behavior generates non-sinusoidal currents in distribution networks, which causes damage to domestic and industrial equipment. The multi-level shunt power active filter is subsequently shown to be an adequate solution to the problem raised. Nevertheless, the difficulty of adjusting the active filter DC supply voltage requires another technology to ensure it. In this article, a photovoltaic generator is associated with the DC bus power terminals of the active filter. The proposed system consists of a field of solar panels, three multi-level voltage inverters connected to the power grid and a non-linear load consisting of a six-diode rectifier bridge supplying a resistive-inductive load. Current control techniques of active and reactive power are used to compensate for both harmonic currents and reactive power as well as to inject active solar power into the distribution network. An algorithm of the search method of the maximum power point of type Perturb and observe is applied. Simulation results of the system proposed under the MATLAB/Simulink environment shows that the performance of control commands that reassure the solar power injection in the network, harmonic current compensation and power factor correction. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Actif%20power%20filter" title="Actif power filter">Actif power filter</a>, <a href="https://publications.waset.org/abstracts/search?q=MPPT" title=" MPPT"> MPPT</a>, <a href="https://publications.waset.org/abstracts/search?q=pertub%26observe%20algorithm" title=" pertub&amp;observe algorithm"> pertub&amp;observe algorithm</a>, <a href="https://publications.waset.org/abstracts/search?q=PV%20array" title=" PV array"> PV array</a>, <a href="https://publications.waset.org/abstracts/search?q=PWM-control" title=" PWM-control"> PWM-control</a> </p> <a href="https://publications.waset.org/abstracts/74962/nine-level-shunt-active-power-filter-associated-with-a-photovoltaic-array-coupled-to-the-electrical-distribution-network" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/74962.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">339</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10164</span> Performance Analysis of Shunt Active Power Filter for Various Reference Current Generation Techniques</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Vishal%20V.%20Choudhari">Vishal V. Choudhari</a>, <a href="https://publications.waset.org/abstracts/search?q=Gaurao%20A.%20Dongre"> Gaurao A. Dongre</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20P.%20Diwan"> S. P. Diwan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A number of reference current generation have been developed for analysis of shunt active power filter to mitigate the load compensation. Depending upon the type of load the technique has to be chosen. In this paper, six reference current generation techniques viz. instantaneous reactive power theory(IRP), Synchronous reference frame theory(SRF), Perfect harmonic cancellation(PHC), Unity power factor method(UPF), Self-tuning filter method(STF), Predictive filtering method(PFM) are compared for different operating conditions. The harmonics are introduced because of non-linear loads in the system. These harmonics are eliminated using above techniques. The results and performance of system simulated on MATLAB/Simulink platform. The system is experimentally implemented using DS1104 card of dSPACE system. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=SAPF" title="SAPF">SAPF</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title=" power quality"> power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=THD" title=" THD"> THD</a>, <a href="https://publications.waset.org/abstracts/search?q=IRP" title=" IRP"> IRP</a>, <a href="https://publications.waset.org/abstracts/search?q=SRF" title=" SRF"> SRF</a>, <a href="https://publications.waset.org/abstracts/search?q=dSPACE%20module%20DS1104" title=" dSPACE module DS1104"> dSPACE module DS1104</a> </p> <a href="https://publications.waset.org/abstracts/19083/performance-analysis-of-shunt-active-power-filter-for-various-reference-current-generation-techniques" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/19083.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">590</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10163</span> FLC with 3DSVM for 4LEG 4WIRE Shunt Active Power Filter</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Abdelhalim%20Kessal">Abdelhalim Kessal</a>, <a href="https://publications.waset.org/abstracts/search?q=Ali%20Chebabhi"> Ali Chebabhi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, a controller based on fuzzy logic control (FLC) associated to Three Dimensional Space Vector Modulation (3DSVM) is applied for shunt active filter in 伪尾o axes domain. The main goals are to improve power quality under disturbed loads, minimize source currents harmonics and reduce neutral current magnitude in the four-wire structure. FLC is used to obtain the reference current and control the DC-bus voltage at the inverter output. The switching signals of the four-leg inverter are generating through a Three Dimensional Space Vector Modulation (3DSVM). Selected simulation results have been shown to validate the proposed system. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=flc" title="flc">flc</a>, <a href="https://publications.waset.org/abstracts/search?q=3dsvm" title=" 3dsvm"> 3dsvm</a>, <a href="https://publications.waset.org/abstracts/search?q=sapf" title=" sapf"> sapf</a>, <a href="https://publications.waset.org/abstracts/search?q=harmonic" title=" harmonic"> harmonic</a>, <a href="https://publications.waset.org/abstracts/search?q=inverter" title=" inverter"> inverter</a> </p> <a href="https://publications.waset.org/abstracts/31182/flc-with-3dsvm-for-4leg-4wire-shunt-active-power-filter" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/31182.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">497</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10162</span> Artificial Neural Networks Face to Sudden Load Change for Shunt Active Power Filter</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Dehini%20Rachid">Dehini Rachid</a>, <a href="https://publications.waset.org/abstracts/search?q=Ferdi%20Brahim"> Ferdi Brahim</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The shunt active power filter (SAPF) is not destined only to improve the power factor, but also to compensate the unwanted harmonic currents produced by nonlinear loads. This paper presents a SAPF with identification and control method based on artificial neural network (ANN). To identify harmonics, many techniques are used, among them the conventional p-q theory and the relatively recent one the artificial neural network method. It is difficult to get satisfied identification and control characteristics by using a normal (ANN) due to the nonlinearity of the system (SAPF + fast nonlinear load variations). This work is an attempt to undertake a systematic study of the problem to equip the (SAPF) with the harmonics identification and DC link voltage control method based on (ANN). The latter has been applied to the (SAPF) with fast nonlinear load variations. The results of computer simulations and experiments are given, which can confirm the feasibility of the proposed active power filter. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=artificial%20neural%20networks%20%28ANN%29" title="artificial neural networks (ANN)">artificial neural networks (ANN)</a>, <a href="https://publications.waset.org/abstracts/search?q=p-q%20theory" title=" p-q theory"> p-q theory</a>, <a href="https://publications.waset.org/abstracts/search?q=harmonics" title=" harmonics"> harmonics</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20harmonic%20distortion" title=" total harmonic distortion"> total harmonic distortion</a> </p> <a href="https://publications.waset.org/abstracts/16181/artificial-neural-networks-face-to-sudden-load-change-for-shunt-active-power-filter" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/16181.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">386</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10161</span> DFIG-Based Wind Turbine with Shunt Active Power Filter Controlled by Double Nonlinear Predictive Controller</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Abderrahmane%20El%20Kachani">Abderrahmane El Kachani</a>, <a href="https://publications.waset.org/abstracts/search?q=El%20Mahjoub%20Chakir"> El Mahjoub Chakir</a>, <a href="https://publications.waset.org/abstracts/search?q=Anass%20Ait%20Laachir"> Anass Ait Laachir</a>, <a href="https://publications.waset.org/abstracts/search?q=Abdelhamid%20Niaaniaa"> Abdelhamid Niaaniaa</a>, <a href="https://publications.waset.org/abstracts/search?q=Jamal%20Zerouaoui"> Jamal Zerouaoui</a>, <a href="https://publications.waset.org/abstracts/search?q=Tarik%20Jarou"> Tarik Jarou</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents a wind turbine based on the doubly fed induction generator (DFIG) connected to the utility grid through a shunt active power filter (SAPF). The whole system is controlled by a double nonlinear predictive controller (DNPC). A Taylor series expansion is used to predict the outputs of the system. The control law is calculated by optimization of the cost function. The first nonlinear predictive controller (NPC) is designed to ensure the high performance tracking of the rotor speed and regulate the rotor current of the DFIG, while the second one is designed to control the SAPF in order to compensate the harmonic produces by the three-phase diode bridge supplied by a passive circuit (rd, Ld). As a result, we obtain sinusoidal waveforms of the stator voltage and stator current. The proposed nonlinear predictive controllers (NPCs) are validated via simulation on a 1.5 MW DFIG-based wind turbine connected to an SAPF. The results obtained appear to be satisfactory and promising. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=wind%20power" title="wind power">wind power</a>, <a href="https://publications.waset.org/abstracts/search?q=doubly%20fed%20induction%20generator" title=" doubly fed induction generator"> doubly fed induction generator</a>, <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter" title=" shunt active power filter"> shunt active power filter</a>, <a href="https://publications.waset.org/abstracts/search?q=double%20nonlinear%20predictive%20controller" title=" double nonlinear predictive controller"> double nonlinear predictive controller</a> </p> <a href="https://publications.waset.org/abstracts/37279/dfig-based-wind-turbine-with-shunt-active-power-filter-controlled-by-double-nonlinear-predictive-controller" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/37279.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">416</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10160</span> Comparative Study between Classical P-Q Method and Modern Fuzzy Controller Method to Improve the Power Quality of an Electrical Network</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=A.%20Morsli">A. Morsli</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Tlem%C3%A7ani"> A. Tlem莽ani</a>, <a href="https://publications.waset.org/abstracts/search?q=N.%20Ould%20Cherchali"> N. Ould Cherchali</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20S.%20Boucherit"> M. S. Boucherit </a> </p> <p class="card-text"><strong>Abstract:</strong></p> This article presents two methods for the compensation of harmonics generated by a nonlinear load. The first is the classic method P-Q. The second is the controller by modern method of artificial intelligence specifically fuzzy logic. Both methods are applied to an Active Power Filter shunt (APFs) based on a three-phase voltage converter at five levels NPC topology. In calculating the harmonic currents of reference, we use the algorithm P-Q and pulse generation, we use the intersective PWM. For flexibility and dynamics, we use fuzzy logic. The results give us clear that the rate of Harmonic Distortion issued by fuzzy logic is better than P-Q. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=fuzzy%20logic%20controller" title="fuzzy logic controller">fuzzy logic controller</a>, <a href="https://publications.waset.org/abstracts/search?q=P-Q%20method" title=" P-Q method"> P-Q method</a>, <a href="https://publications.waset.org/abstracts/search?q=pulse%20width%0D%0Amodulation%20%28PWM%29" title=" pulse width modulation (PWM)"> pulse width modulation (PWM)</a>, <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter%20%28sAPF%29" title=" shunt active power filter (sAPF)"> shunt active power filter (sAPF)</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20harmonic%20distortion%20%28THD%29" title=" total harmonic distortion (THD)"> total harmonic distortion (THD)</a> </p> <a href="https://publications.waset.org/abstracts/28814/comparative-study-between-classical-p-q-method-and-modern-fuzzy-controller-method-to-improve-the-power-quality-of-an-electrical-network" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/28814.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">548</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10159</span> Harmonic Assessment and Mitigation in Medical Diagonesis Equipment</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=S.%20S.%20Adamu">S. S. Adamu</a>, <a href="https://publications.waset.org/abstracts/search?q=H.%20S.%20Muhammad"> H. S. Muhammad</a>, <a href="https://publications.waset.org/abstracts/search?q=D.%20S.%20Shuaibu"> D. S. Shuaibu</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Poor power quality in electrical power systems can lead to medical equipment at healthcare centres to malfunction and present wrong medical diagnosis. Equipment such as X-rays, computerized axial tomography, etc. can pollute the system due to their high level of harmonics production, which may cause a number of undesirable effects like heating, equipment damages and electromagnetic interferences. The conventional approach of mitigation uses passive inductor/capacitor (LC) filters, which has some drawbacks such as, large sizes, resonance problems and fixed compensation behaviours. The current trends of solutions generally employ active power filters using suitable control algorithms. This work focuses on assessing the level of Total Harmonic Distortion (THD) on medical facilities and various ways of mitigation, using radiology unit of an existing hospital as a case study. The measurement of the harmonics is conducted with a power quality analyzer at the point of common coupling (PCC). The levels of measured THD are found to be higher than the IEEE 519-1992 standard limits. The system is then modelled as a harmonic current source using MATLAB/SIMULINK. To mitigate the unwanted harmonic currents a shunt active filter is developed using synchronous detection algorithm to extract the fundamental component of the source currents. Fuzzy logic controller is then developed to control the filter. The THD without the active power filter are validated using the measured values. The THD with the developed filter show that the harmonics are now within the recommended limits. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title="power quality">power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20harmonics%20distortion" title=" total harmonics distortion"> total harmonics distortion</a>, <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20filters" title=" shunt active filters"> shunt active filters</a>, <a href="https://publications.waset.org/abstracts/search?q=fuzzy%20logic" title=" fuzzy logic"> fuzzy logic</a> </p> <a href="https://publications.waset.org/abstracts/14562/harmonic-assessment-and-mitigation-in-medical-diagonesis-equipment" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/14562.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">479</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10158</span> Integration of UPQC Based on Fuzzy Controller for Power Quality Enhancement in Distributed Network</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Habab">M. Habab</a>, <a href="https://publications.waset.org/abstracts/search?q=C.%20Benachaiba"> C. Benachaiba</a>, <a href="https://publications.waset.org/abstracts/search?q=B.%20Mazari"> B. Mazari</a>, <a href="https://publications.waset.org/abstracts/search?q=H.%20Madi"> H. Madi</a>, <a href="https://publications.waset.org/abstracts/search?q=C.%20Benoudjafer"> C. Benoudjafer</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The use of Distributed Generation (DG) has been increasing in recent years to fill the gap between energy supply and demand. This paper presents the grid connected wind energy system with UPQC based on fuzzy controller to compensate for voltage and current disturbances. The proposed system can improve power quality at the point of installation on power distribution systems. Simulation results show the capability of the DG-UPQC intelligent system to compensate sags voltage and current harmonics at the Point of Common Coupling (PCC). <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20filter" title="shunt active filter">shunt active filter</a>, <a href="https://publications.waset.org/abstracts/search?q=series%20active%20filter" title=" series active filter"> series active filter</a>, <a href="https://publications.waset.org/abstracts/search?q=UPQC" title=" UPQC"> UPQC</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title=" power quality"> power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=sags%20voltage" title=" sags voltage"> sags voltage</a>, <a href="https://publications.waset.org/abstracts/search?q=distributed%20generation" title=" distributed generation"> distributed generation</a>, <a href="https://publications.waset.org/abstracts/search?q=wind%20turbine" title=" wind turbine"> wind turbine</a> </p> <a href="https://publications.waset.org/abstracts/1656/integration-of-upqc-based-on-fuzzy-controller-for-power-quality-enhancement-in-distributed-network" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/1656.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">407</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10157</span> Unified Power Quality Conditioner Presentation and Dimensioning</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Abderrahmane%20Kechich">Abderrahmane Kechich</a>, <a href="https://publications.waset.org/abstracts/search?q=Othmane%20Abdelkhalek"> Othmane Abdelkhalek</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Static converters behave as nonlinear loads that inject harmonic currents into the grid and increase the consumption of the inactive power. On the other hand, the increased use of sensitive equipment requires the application of sinusoidal voltages. As a result, the electrical power quality control has become a major concern in the field of power electronics. In this context, the active power conditioner (UPQC) was developed. It combines both serial and parallel structures; the series filter can protect sensitive loads and compensate for voltage disturbances such as voltage harmonics, voltage dips or flicker when the shunt filter compensates for current disturbances such as current harmonics, reactive currents and imbalance. This double feature is that it is one of the most appropriate devices. Calculating parameters is an important step and in the same time it鈥檚 not easy for that reason several researchers based on trial and error method for calculating parameters but this method is not easy for beginners researchers especially what about the controller鈥檚 parameters, for that reason this paper gives a mathematical way to calculate of almost all of UPQC parameters away from trial and error method. This paper gives also a new approach for calculating of PI regulators parameters for purpose to have a stable UPQC able to compensate for disturbances acting on the waveform of line voltage and load current in order to improve the electrical power quality. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=UPQC" title="UPQC">UPQC</a>, <a href="https://publications.waset.org/abstracts/search?q=Shunt%20active%20filer" title=" Shunt active filer"> Shunt active filer</a>, <a href="https://publications.waset.org/abstracts/search?q=series%20active%20filer" title=" series active filer"> series active filer</a>, <a href="https://publications.waset.org/abstracts/search?q=PI%20controller" title=" PI controller"> PI controller</a>, <a href="https://publications.waset.org/abstracts/search?q=PWM%20control" title=" PWM control"> PWM control</a>, <a href="https://publications.waset.org/abstracts/search?q=dual-loop%20control" title=" dual-loop control"> dual-loop control</a> </p> <a href="https://publications.waset.org/abstracts/21017/unified-power-quality-conditioner-presentation-and-dimensioning" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/21017.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">403</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10156</span> Artificial Neural Networks Controller for Active Power Filter Connected to a Photovoltaic Array </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Rachid%20Dehini">Rachid Dehini</a>, <a href="https://publications.waset.org/abstracts/search?q=Brahim%20Berbaoui"> Brahim Berbaoui</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The main objectives of shunt active power filter (SAPF) is to preserve the power system from unwanted harmonic currents produced by nonlinear loads, as well as to compensate the reactive power. The aim of this paper is to present a (PAPF) supplied by the Photovoltaic cells ,in such a way that the (PAPF) feeds the linear and nonlinear loads by harmonics currents and the excess of the energy is injected into the power system. In order to improve the performances of conventional (PAPF) This paper also proposes artificial neural networks (ANN) for harmonics identification and DC link voltage control. The simulation study results of the new (SAPF) identification technique are found quite satisfactory by assuring good filtering characteristics and high system stability. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=SAPF" title="SAPF">SAPF</a>, <a href="https://publications.waset.org/abstracts/search?q=harmonics%20current" title=" harmonics current"> harmonics current</a>, <a href="https://publications.waset.org/abstracts/search?q=photovoltaic%0D%0Acells" title=" photovoltaic cells"> photovoltaic cells</a>, <a href="https://publications.waset.org/abstracts/search?q=MPPT" title=" MPPT"> MPPT</a>, <a href="https://publications.waset.org/abstracts/search?q=artificial%20neural%20networks%20%28ANN%29" title=" artificial neural networks (ANN)"> artificial neural networks (ANN)</a> </p> <a href="https://publications.waset.org/abstracts/40570/artificial-neural-networks-controller-for-active-power-filter-connected-to-a-photovoltaic-array" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/40570.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">331</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10155</span> Effect of Parameters for Exponential Loads on Voltage Transmission Line with Compensation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Benalia%20Nadia">Benalia Nadia</a>, <a href="https://publications.waset.org/abstracts/search?q=Bensiali%20Nadia"> Bensiali Nadia</a>, <a href="https://publications.waset.org/abstracts/search?q=Zerzouri%20Noura"> Zerzouri Noura</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents an analysis of the effects of parameters np and nq for exponential load on the transmission line voltage profile, transferred power and transmission losses for different shunt compensation size. For different values for np and nq in which active and reactive power vary with it is terminal voltages as in exponential form, variations of the load voltage for different sizes of shunt capacitors are simulated with a simple two-bus power system using Matlab SimPowerSystems Toolbox. It is observed that the compensation level is significantly affected by the voltage sensitivities of loads. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=static%20load%20model" title="static load model">static load model</a>, <a href="https://publications.waset.org/abstracts/search?q=shunt%20compensation" title=" shunt compensation"> shunt compensation</a>, <a href="https://publications.waset.org/abstracts/search?q=transmission%20system" title=" transmission system"> transmission system</a>, <a href="https://publications.waset.org/abstracts/search?q=exponentiel%20load%20model" title=" exponentiel load model"> exponentiel load model</a> </p> <a href="https://publications.waset.org/abstracts/41469/effect-of-parameters-for-exponential-loads-on-voltage-transmission-line-with-compensation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/41469.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">368</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10154</span> Synchronous Reference Frame and Instantaneous P-Q Theory Based Control of Unified Power Quality Conditioner for Power Quality Improvement of Distribution System</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ambachew%20Simreteab%20Gebremedhn">Ambachew Simreteab Gebremedhn</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Context: The paper explores the use of synchronous reference frame theory (SRFT) and instantaneous reactive power theory (IRPT) based control of Unified Power Quality Conditioner (UPQC) for improving power quality in distribution systems. Research Aim: To investigate the performance of different control configurations of UPQC using SRFT and IRPT for mitigating power quality issues in distribution systems. Methodology: The study compares three control techniques (SRFT-IRPT, SRFT-SRFT, IRPT-IRPT) implemented in series and shunt active filters of UPQC. Data is collected under various control algorithms to analyze UPQC performance. Findings: Results indicate the effectiveness of SRFT and IRPT based control techniques in addressing power quality problems such as voltage sags, swells, unbalance, harmonics, and current harmonics in distribution systems. Theoretical Importance: The study provides insights into the application of SRFT and IRPT in improving power quality, specifically in mitigating unbalanced voltage sags, where conventional methods fall short. Data Collection: Data is collected under various control algorithms using simulation in MATLAB Simulink and real-time operation executed with experimental results obtained using RT-LAB. Analysis Procedures: Performance analysis of UPQC under different control algorithms is conducted to evaluate the effectiveness of SRFT and IRPT based control techniques in mitigating power quality issues. Questions Addressed: How do SRFT and IRPT based control techniques compare in improving power quality in distribution systems? What is the impact of using different control configurations on the performance of UPQC? Conclusion: The study demonstrates the efficacy of SRFT and IRPT based control of UPQC in mitigating power quality issues in distribution systems, highlighting their potential for enhancing voltage and current quality. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title="power quality">power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=UPQC" title=" UPQC"> UPQC</a>, <a href="https://publications.waset.org/abstracts/search?q=shunt%20active%20filter" title=" shunt active filter"> shunt active filter</a>, <a href="https://publications.waset.org/abstracts/search?q=series%20active%20filter" title=" series active filter"> series active filter</a>, <a href="https://publications.waset.org/abstracts/search?q=non-linear%20load" title=" non-linear load"> non-linear load</a>, <a href="https://publications.waset.org/abstracts/search?q=RT-LAB" title=" RT-LAB"> RT-LAB</a>, <a href="https://publications.waset.org/abstracts/search?q=MATLAB" title=" MATLAB"> MATLAB</a> </p> <a href="https://publications.waset.org/abstracts/193840/synchronous-reference-frame-and-instantaneous-p-q-theory-based-control-of-unified-power-quality-conditioner-for-power-quality-improvement-of-distribution-system" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/193840.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">9</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10153</span> A Model Predictive Control Based Virtual Active Power Filter Using V2G Technology</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mahdi%20Zolfaghari">Mahdi Zolfaghari</a>, <a href="https://publications.waset.org/abstracts/search?q=Seyed%20Hossein%20Hosseinian"> Seyed Hossein Hosseinian</a>, <a href="https://publications.waset.org/abstracts/search?q=Hossein%20Askarian%20Abyaneh"> Hossein Askarian Abyaneh</a>, <a href="https://publications.waset.org/abstracts/search?q=Mehrdad%20Abedi"> Mehrdad Abedi </a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents a virtual active power filter (VAPF) using vehicle to grid (V2G) technology to maintain power quality requirements. The optimal discrete operation of the power converter of electric vehicle (EV) is based on recognizing desired switching states using the model predictive control (MPC) algorithm. A fast dynamic response, lower total harmonic distortion (THD) and good reference tracking performance are realized through the presented control strategy. The simulation results using MATLAB/Simulink validate the effectiveness of the scheme in improving power quality as well as good dynamic response in power transferring capability. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electric%20vehicle" title="electric vehicle">electric vehicle</a>, <a href="https://publications.waset.org/abstracts/search?q=model%20predictive%20control" title=" model predictive control"> model predictive control</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title=" power quality"> power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=V2G%20technology" title=" V2G technology"> V2G technology</a>, <a href="https://publications.waset.org/abstracts/search?q=virtual%20active%20power%20filter" title=" virtual active power filter"> virtual active power filter</a> </p> <a href="https://publications.waset.org/abstracts/70930/a-model-predictive-control-based-virtual-active-power-filter-using-v2g-technology" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/70930.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">430</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10152</span> Compact Microstrip Ultra-Wideband Bandstop Filter With Quasi-Elliptic Function Response</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hussein%20Shaman">Hussein Shaman</a>, <a href="https://publications.waset.org/abstracts/search?q=Faris%20Almansour"> Faris Almansour</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper proposes a modified optimum bandstop filter with ultra-wideband stopband. The filter consists of three shunt open-circuited stubs and two non-redundant unit elements. The proposed bandstop filter is designed with unequal electrical lengths of the open-circuited stubs at the mid-stopband. Therefore, the filter can exhibit a quasi-elliptic function response that improves the selectivity and enhances the rejection bandwidth. The filter is designed to exhibit a fractional bandwidth of about 114% at a mid-stopband frequency of 3.0 GHz. The filter is successfully realized in theory, simulated, fabricated and measured. An excellent agreement is obtained between calculated, simulated and measured. The fabricated filter has a compact size with a low insertion loss in the passbands, high selectivity and good attenuation level inside the desired stopband <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=microstrip%20filter" title="microstrip filter">microstrip filter</a>, <a href="https://publications.waset.org/abstracts/search?q=bandstop%20filter" title=" bandstop filter"> bandstop filter</a>, <a href="https://publications.waset.org/abstracts/search?q=UWB%20filter" title=" UWB filter"> UWB filter</a>, <a href="https://publications.waset.org/abstracts/search?q=transmission%20line%20filter" title=" transmission line filter"> transmission line filter</a> </p> <a href="https://publications.waset.org/abstracts/151305/compact-microstrip-ultra-wideband-bandstop-filter-with-quasi-elliptic-function-response" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/151305.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">148</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10151</span> Optimal Capacitor Placement in Distribution Using Cuckoo Optimization Algorithm</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ali%20Ravangard">Ali Ravangard</a>, <a href="https://publications.waset.org/abstracts/search?q=S.%20Mohammadi"> S. Mohammadi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Shunt Capacitors have several uses in the electric power systems. They are utilized as sources of reactive power by connecting them in line-to-neutral. Electric utilities have also connected capacitors in series with long lines in order to reduce its impedance. This is particularly common in the transmission level, where the lines have length in several hundreds of kilometers. However, this post will generally discuss shunt capacitors. In distribution systems, shunt capacitors are used to reduce power losses, to improve voltage profile, and to increase the maximum flow through cables and transformers. This paper presents a new method to determine the optimal locations and economical sizing of fixed and/or switched shunt capacitors with a view to power losses reduction and voltage stability enhancement. For solving the problem, a new enhanced cuckoo optimization algorithm is presented.The proposed method is tested on distribution test system and the results show that the algorithm suitable for practical implementation on real systems with any size. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=capacitor%20placement" title="capacitor placement">capacitor placement</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20losses" title=" power losses"> power losses</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20stability" title=" voltage stability"> voltage stability</a>, <a href="https://publications.waset.org/abstracts/search?q=radial%20distribution%20systems" title=" radial distribution systems"> radial distribution systems</a> </p> <a href="https://publications.waset.org/abstracts/44037/optimal-capacitor-placement-in-distribution-using-cuckoo-optimization-algorithm" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/44037.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">377</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10150</span> Design and Simulation of Unified Power Quality Conditioner based on Adaptive Fuzzy PI Controller</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Brahim%20Ferdi">Brahim Ferdi</a>, <a href="https://publications.waset.org/abstracts/search?q=Samira%20Dib"> Samira Dib</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The unified power quality conditioner (UPQC), a combination of shunt and series active power filter, is one of the best solutions towards the mitigation of voltage and current harmonics problems in distribution power system. PI controller is very common in the control of UPQC. However, one disadvantage of this conventional controller is the difficulty in tuning its gains (Kp and Ki). To overcome this problem, an adaptive fuzzy logic PI controller is proposed. The controller is composed of fuzzy controller and PI controller. According to the error and error rate of the control system and fuzzy control rules, the fuzzy controller can online adjust the two gains of the PI controller to get better performance of UPQC. Simulations using MATLAB/SIMULINK are carried out to verify the performance of the proposed controller. The results show that the proposed controller has fast dynamic response and high accuracy of tracking the current and voltage references. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=adaptive%20fuzzy%20PI%20controller" title="adaptive fuzzy PI controller">adaptive fuzzy PI controller</a>, <a href="https://publications.waset.org/abstracts/search?q=current%20harmonics" title=" current harmonics"> current harmonics</a>, <a href="https://publications.waset.org/abstracts/search?q=PI%20controller" title=" PI controller"> PI controller</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20harmonics" title=" voltage harmonics"> voltage harmonics</a>, <a href="https://publications.waset.org/abstracts/search?q=UPQC" title=" UPQC"> UPQC</a> </p> <a href="https://publications.waset.org/abstracts/16996/design-and-simulation-of-unified-power-quality-conditioner-based-on-adaptive-fuzzy-pi-controller" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/16996.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">556</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10149</span> Variable Shunt Reactors for Reactive Power Compensation of HV Subsea Cables</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Saeed%20A.%20AlGhamdi">Saeed A. AlGhamdi</a>, <a href="https://publications.waset.org/abstracts/search?q=Nabil%20Habli"> Nabil Habli</a>, <a href="https://publications.waset.org/abstracts/search?q=Vinoj%20Somasanran"> Vinoj Somasanran</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents an application of 230 kV Variable Shunt Reactors (VSR) used to compensate reactive power of dual 90 KM subsea cables. VSR integrates an on-load tap changer (OLTC) that adjusts reactive power compensation to maintain acceptable bus voltages under variable load profile and network configuration. An automatic voltage regulator (AVR) or a power management system (PMS) that allows VSR rating to be changed in discrete steps typically controls the OLTC. Typical regulation range start as minimum as 20% up to 100% and are available for systems up to 550kV. The regulation speed is normally in the order of seconds per step and approximately a minute from maximum to minimum rating. VSR can be bus or line connected depending on line/cable length and compensation requirements. The flexible reactive compensation ranges achieved by recent VSR technologies have enabled newer facilities design to deploy line connected VSR through either disconnect switches, which saves space and cost, or through circuit breakers. Lines with VSR are typically energized with lower taps (reduced reactive compensation) to minimize or remove the presence of delayed zero crossing. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=power%20management" title="power management">power management</a>, <a href="https://publications.waset.org/abstracts/search?q=reactive%20power" title=" reactive power"> reactive power</a>, <a href="https://publications.waset.org/abstracts/search?q=subsea%20cables" title=" subsea cables"> subsea cables</a>, <a href="https://publications.waset.org/abstracts/search?q=variable%20shunt%20reactors" title=" variable shunt reactors"> variable shunt reactors</a> </p> <a href="https://publications.waset.org/abstracts/143206/variable-shunt-reactors-for-reactive-power-compensation-of-hv-subsea-cables" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/143206.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">251</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10148</span> Ventriculo-Gallbladder Shunt: Case Series and Literature Review</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sandrieli%20Afornali">Sandrieli Afornali</a>, <a href="https://publications.waset.org/abstracts/search?q=Adriano%20Keijiro%20Maeda"> Adriano Keijiro Maeda</a>, <a href="https://publications.waset.org/abstracts/search?q=Renato%20Fedatto%20Beraldo"> Renato Fedatto Beraldo</a>, <a href="https://publications.waset.org/abstracts/search?q=Carlos%20Alberto%20Mattozo"> Carlos Alberto Mattozo</a>, <a href="https://publications.waset.org/abstracts/search?q=Ricardo%20Nascimento%20Brito"> Ricardo Nascimento Brito</a> </p> <p class="card-text"><strong>Abstract:</strong></p> BACKGROUND: The most used variety in hydrocephalus treatment is the ventriculoperitoneal shunt (VPS). However, it may fails in 20 to 70% of cases. It makes necessary to have alternative cavities for the implantation of the distal catheter. Ventriculo-atrial shunting (VAS) is described as the second option. To our knowledge, there are 121 reported cases of VGB shunt in children until 2020 and a highly variable success rate, from 25 to 100%, with an average of 63% of patients presenting good long-term results. Our goal is to evaluate the epidemiological profile of patients submitted to ventriculo-gallbladder (VGB) shunt and, through a review of literature, to compare our results with others series. METHODS: a retrospective cross-sectional observational study of a case series of nine patients. The medical records of all patients were reviewed, who underwent VGB shunt at the Hospital Pequeno Pr铆ncipe from Curitiba, Paran谩, Brazil, from January 2014 to October 2022. The inclusion criteria were: patients under 17 years of age with hydrocephalus of any etiology, currently using or prior to VGB shunt. RESULTS: There were 6 (66,7%) male and 3 (33,3%) female. The average age of 73.6 months or 6.1 years at the time of surgery. They were submitted on average 5.1 VPS reviews previous to VGB shunt. Five (55,5%) had complications of VGB shunt: infection (11.1%), atony (11.1%), hypodrainage due to kinking the distal catheter in the solution (11.1%) and ventriculoenteric fistula (22.2%); all these patients were cured at surgical reapproach, and in 2 of them the VGB shunt was reimplanted. Two patients died (22.2%), and five (55,5%) patients maintained the use of VGB shunt in the follow-up period; and in 4 (44.4%) there was never need for review. CONCLUSION: VGB shunt tends to be underestimated because it is still unconventional and little publicized in literature. Our article shows a lower risk of death and similar risk of complications when compared to others altenatives shunts. We emphasize VGB shunt as a safe procedure to be the second option when VPS fails or has contraindications. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hydrocephalus" title="hydrocephalus">hydrocephalus</a>, <a href="https://publications.waset.org/abstracts/search?q=ventricular-gallbladder%20shunt" title=" ventricular-gallbladder shunt"> ventricular-gallbladder shunt</a>, <a href="https://publications.waset.org/abstracts/search?q=VGB%20shunt" title=" VGB shunt"> VGB shunt</a>, <a href="https://publications.waset.org/abstracts/search?q=VPS" title=" VPS"> VPS</a>, <a href="https://publications.waset.org/abstracts/search?q=ventriculoperitoneal%20shunt" title=" ventriculoperitoneal shunt"> ventriculoperitoneal shunt</a>, <a href="https://publications.waset.org/abstracts/search?q=ventriculoatrial%20shunt" title=" ventriculoatrial shunt"> ventriculoatrial shunt</a> </p> <a href="https://publications.waset.org/abstracts/163987/ventriculo-gallbladder-shunt-case-series-and-literature-review" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/163987.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">72</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10147</span> Improving Power Quality in Wind Power Generation System </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=A.%20Omeiri">A. Omeiri</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Djellad"> A. Djellad</a>, <a href="https://publications.waset.org/abstracts/search?q=P.%20O.%20Logerais"> P. O. Logerais</a>, <a href="https://publications.waset.org/abstracts/search?q=O.%20Riou"> O. Riou</a>, <a href="https://publications.waset.org/abstracts/search?q=J.%20F.%20Durastanti"> J. F. Durastanti</a> </p> <p class="card-text"><strong>Abstract:</strong></p> With the growing of electrical energy demand, wind power capacity has experienced tremendous growth in the past decade, thanks to wind power鈥檚 environmental benefits. Direct driven permanent magnet synchronous generator (PMSG) with a full size back-to-back converter set is one of the promising technologies employed with wind power generation. Wind grid integration brings the problems of voltage fluctuation and harmonic pollution. In the present study, the filter is placed between the wind system and the network to reduce the total harmonic distortion (THD) and enhance power quality during disturbances. The models of wind turbine, PMSG, power electronic converters and the filter are implemented in MATLAB/SIMULINK environment. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=wind%20energy%20conversion%20system" title="wind energy conversion system">wind energy conversion system</a>, <a href="https://publications.waset.org/abstracts/search?q=PMSG" title=" PMSG"> PMSG</a>, <a href="https://publications.waset.org/abstracts/search?q=PWM" title=" PWM"> PWM</a>, <a href="https://publications.waset.org/abstracts/search?q=THD" title=" THD"> THD</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title=" power quality"> power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=passive%20filter" title=" passive filter"> passive filter</a> </p> <a href="https://publications.waset.org/abstracts/21899/improving-power-quality-in-wind-power-generation-system" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/21899.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">648</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10146</span> Simulink Library for Reference Current Generation in Active DC Traction Substations</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mihaela%20Popescu">Mihaela Popescu</a>, <a href="https://publications.waset.org/abstracts/search?q=Alexandru%20Bitoleanu"> Alexandru Bitoleanu</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper is focused on the reference current calculation in the compensation mode of the active DC traction substations. The so-called p-q theory of the instantaneous reactive power is used as theoretical foundation. The compensation goal of total compensation is taken into consideration for the operation under both sinusoidal and nonsinusoidal voltage conditions, through the two objectives of unity power factor and perfect harmonic cancelation. Four blocks of reference current generation implement the conceived algorithms and they are included in a specific Simulink library, which is useful in a DSP dSPACE-based platform working under Matlab/Simulink. The simulation results validate the correctness of the implementation and fulfillment of the compensation tasks. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=active%20power%20filter" title="active power filter">active power filter</a>, <a href="https://publications.waset.org/abstracts/search?q=DC%20traction" title=" DC traction"> DC traction</a>, <a href="https://publications.waset.org/abstracts/search?q=p-q%20theory" title=" p-q theory"> p-q theory</a>, <a href="https://publications.waset.org/abstracts/search?q=Simulink%20library" title=" Simulink library"> Simulink library</a> </p> <a href="https://publications.waset.org/abstracts/27955/simulink-library-for-reference-current-generation-in-active-dc-traction-substations" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/27955.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">674</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10145</span> Optimal Capacitor Placement in Distribution Systems </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sana%20Ansari">Sana Ansari</a>, <a href="https://publications.waset.org/abstracts/search?q=Sirus%20Mohammadi"> Sirus Mohammadi </a> </p> <p class="card-text"><strong>Abstract:</strong></p> In distribution systems, shunt capacitors are used to reduce power losses, to improve voltage profile, and to increase the maximum flow through cables and transformers. This paper presents a new method to determine the optimal locations and economical sizing of fixed and/or switched shunt capacitors with a view to power losses reduction and voltage stability enhancement. General Algebraic Modeling System (GAMS) has been used to solve the maximization modules using the MINOS optimization software with Linear Programming (LP). The proposed method is tested on 33 node distribution system and the results show that the algorithm suitable for practical implementation on real systems with any size. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=power%20losses" title="power losses">power losses</a>, <a href="https://publications.waset.org/abstracts/search?q=voltage%20stability" title=" voltage stability"> voltage stability</a>, <a href="https://publications.waset.org/abstracts/search?q=radial%20distribution%20systems" title=" radial distribution systems"> radial distribution systems</a>, <a href="https://publications.waset.org/abstracts/search?q=capacitor" title=" capacitor"> capacitor</a> </p> <a href="https://publications.waset.org/abstracts/19576/optimal-capacitor-placement-in-distribution-systems" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/19576.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">647</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10144</span> Optimization of Multiplier Extraction Digital Filter On FPGA</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Shiksha%20Jain">Shiksha Jain</a>, <a href="https://publications.waset.org/abstracts/search?q=Ramesh%20Mishra"> Ramesh Mishra</a> </p> <p class="card-text"><strong>Abstract:</strong></p> One of the most widely used complex signals processing operation is filtering. The most important FIR digital filter are widely used in DSP for filtering to alter the spectrum according to some given specifications. Power consumption and Area complexity in the algorithm of Finite Impulse Response (FIR) filter is mainly caused by multipliers. So we present a multiplier less technique (DA technique). In this technique, precomputed value of inner product is stored in LUT. Which are further added and shifted with number of iterations equal to the precision of input sample. But the exponential growth of LUT with the order of FIR filter, in this basic structure, makes it prohibitive for many applications. The significant area and power reduction over traditional Distributed Arithmetic (DA) structure is presented in this paper, by the use of slicing of LUT to the desired length. An architecture of 16 tap FIR filter is presented, with different length of slice of LUT. The result of FIR Filter implementation on Xilinx ISE synthesis tool (XST) vertex-4 FPGA Tool by using proposed method shows the increase of the maximum frequency, the decrease of the resources as usage saving in area with more number of slices and the reduction dynamic power. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=multiplier%20less%20technique" title="multiplier less technique">multiplier less technique</a>, <a href="https://publications.waset.org/abstracts/search?q=linear%20phase%20symmetric%20FIR%20filter" title=" linear phase symmetric FIR filter"> linear phase symmetric FIR filter</a>, <a href="https://publications.waset.org/abstracts/search?q=FPGA%20tool" title=" FPGA tool"> FPGA tool</a>, <a href="https://publications.waset.org/abstracts/search?q=look%20up%20table" title=" look up table"> look up table</a> </p> <a href="https://publications.waset.org/abstracts/17093/optimization-of-multiplier-extraction-digital-filter-on-fpga" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/17093.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">390</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10143</span> Filter for the Measurement of Supraharmonics in Distribution Networks</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sivaraman%20Karthikeyan">Sivaraman Karthikeyan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Due to rapidly developing power electronics devices and technologies such as power line communication or self-commutating converters, voltage and current distortion, as well as interferences, have increased in the frequency range of 2 kHz to 150 kHz; there is an urgent need for regulation of electromagnetic compatibility (EMC) standards in this frequency range. Measuring or testing compliance with emission and immunity limitations necessitates the use of precise, repeatable measuring methods. Appropriate filters to minimize the fundamental component and its harmonics below 2 kHz in the measuring signal would improve the measurement accuracy in this frequency range leading to better analysis. This paper discusses filter suggestions in the current measurement standard and proposes an infinite impulse response (IIR) filter design that is optimized for a low number of poles, strong fundamental damping, and high accuracy above 2 kHz. The new filter鈥檚 transfer function is delivered as a result. An analog implementation is derived from the overall design. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=supraharmonics" title="supraharmonics">supraharmonics</a>, <a href="https://publications.waset.org/abstracts/search?q=2%20kHz" title=" 2 kHz"> 2 kHz</a>, <a href="https://publications.waset.org/abstracts/search?q=150%20kHz" title=" 150 kHz"> 150 kHz</a>, <a href="https://publications.waset.org/abstracts/search?q=filter" title=" filter"> filter</a>, <a href="https://publications.waset.org/abstracts/search?q=analog%20filter" title=" analog filter"> analog filter</a> </p> <a href="https://publications.waset.org/abstracts/157610/filter-for-the-measurement-of-supraharmonics-in-distribution-networks" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/157610.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">146</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">10142</span> Design of Active Power Filters for Harmonics on Power System and Reducing Harmonic Currents</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=D%C3%BCzg%C3%BCn%20Akmaz">D眉zg眉n Akmaz</a>, <a href="https://publications.waset.org/abstracts/search?q=H%C3%BCseyin%20Eri%C5%9Fti"> H眉seyin Eri艧ti</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In the last few years, harmonics have been occurred with the increasing use of nonlinear loads, and these harmonics have been an ever increasing problem for the line systems. This situation importantly affects the quality of power and gives large losses to the network. An efficient way to solve these problems is providing harmonic compensation through parallel active power filters. Many methods can be used in the control systems of the parallel active power filters which provide the compensation. These methods efficiently affect the performance of the active power filters. For this reason, the chosen control method is significant. In this study, Fourier analysis (FA) control method and synchronous reference frame (SRF) control method are discussed. These control methods are designed for both eliminate harmonics and perform reactive power compensation in MATLAB/Simulink pack program and are tested. The results have been compared for each two methods. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=parallel%20active%20power%20filters" title="parallel active power filters">parallel active power filters</a>, <a href="https://publications.waset.org/abstracts/search?q=harmonic%20compensation" title=" harmonic compensation"> harmonic compensation</a>, <a href="https://publications.waset.org/abstracts/search?q=power%20quality" title=" power quality"> power quality</a>, <a href="https://publications.waset.org/abstracts/search?q=harmonics" title=" harmonics"> harmonics</a> </p> <a href="https://publications.waset.org/abstracts/11639/design-of-active-power-filters-for-harmonics-on-power-system-and-reducing-harmonic-currents" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/11639.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">459</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">&lsaquo;</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=339">339</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=340">340</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=shunt%20active%20power%20filter&amp;page=2" rel="next">&rsaquo;</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">&copy; 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">&times;</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>

Pages: 1 2 3 4 5 6 7 8 9 10