CINXE.COM

Search results for: hip arthroplasty

<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: hip arthroplasty</title> <meta name="description" content="Search results for: hip arthroplasty"> <meta name="keywords" content="hip arthroplasty"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="hip arthroplasty" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="hip arthroplasty"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 45</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: hip arthroplasty</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">45</span> Return to Work Following Knee Arthroplasty: A Retrospective Review in Urban Asian Population</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Fiona%20Tan">Fiona Tan</a>, <a href="https://publications.waset.org/abstracts/search?q=Cheryl%20Tan"> Cheryl Tan</a>, <a href="https://publications.waset.org/abstracts/search?q=Thomas%20Wong"> Thomas Wong</a>, <a href="https://publications.waset.org/abstracts/search?q=Remesh"> Remesh</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: An increasing number of working adults undergo knee arthroplasty in Singapore. There is limited data concerning Southeast Asian patients returning to work (RTW) following knee replacement surgery. Our aim was to identify and study factors influencing patients' RTW following total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA). Methods: Patients who underwent TKA or UKA between August 2017 to March 2020 in our center were included in this study. Outcomes include RTW and duration prior to RTW. Results: 441 patients underwent TKA (295 women, 146 men, mean age 67.3 years), and 69 underwent UKA (48 women, 21 men, mean age 61.1 years). Patients who underwent TKA returned to work earlier (mean 83.7 ± 27.1 days) compared to UKA (mean 94.4 ± 42.3 days). 90.0% of TKA patients RTW compared to 95.5% who underwent UKA. Of patients who RTW, 94.3% of the TKA group returned to employment of the same nature compared to 92.9% of UKA patients. Patients who RTW were of a younger age (p = 0.03), white-collared workers (p = 0.04), and had independent preoperative ambulatory status (p <0.01). Conclusion: Younger and independently ambulating patients may have a better capacity for rehabilitation and RTW post-arthroplasty surgery. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=return%20to%20work" title="return to work">return to work</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20knee%20arthroplasty" title=" total knee arthroplasty"> total knee arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=unilateral%20knee%20arthroplasty" title=" unilateral knee arthroplasty"> unilateral knee arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=employment" title=" employment"> employment</a> </p> <a href="https://publications.waset.org/abstracts/186199/return-to-work-following-knee-arthroplasty-a-retrospective-review-in-urban-asian-population" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/186199.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">38</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">44</span> The Effect of Exercise Therapy and Electroacupuncture on Some Clinical Outcomes in People with Post Total Hip Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Marzieh%20Yassin">Marzieh Yassin</a>, <a href="https://publications.waset.org/abstracts/search?q=Masoud%20Rashed"> Masoud Rashed</a>, <a href="https://publications.waset.org/abstracts/search?q=Soheil%20Mansour%20Sohani"> Soheil Mansour Sohani</a>, <a href="https://publications.waset.org/abstracts/search?q=Reza%20Salehi"> Reza Salehi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Hip arthroplasty is one of the surgical methods to improve symptoms in patients with hip osteoarthritis. The use of electroacupuncture and TENS reduces pain, increases range of motion and improves performance. Methods: In this clinical trial study, 30 patients after hip arthroplasty were randomly divided into two groups: electroacupuncture (n=16) with exercise therapy and TENS with exercise therapy (n=14). Severity of pain, quality of life, range of motion, edema and function were evaluated in two groups before and after the interventions. Interventions of 10 sessions (three sessions per week) were conducted for two groups. The significance level in all tests was below 0.05. Results: The results showed that both groups improved all of the symptoms after the intervention (p≤0.05), although there was no statistically significant difference between the two groups in terms of effectiveness (p≥0.05). Conclusion: The results showed that both methods improve symptoms in patients after surgery. According to this study, electroacupuncture is suggested as a new method effective for the treatment of people with post-Total Hip Arthroplasty. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electroacupuncture" title="electroacupuncture">electroacupuncture</a>, <a href="https://publications.waset.org/abstracts/search?q=physical%20performance" title=" physical performance"> physical performance</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20hip%20arthroplasty" title=" total hip arthroplasty"> total hip arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=TENS" title=" TENS"> TENS</a> </p> <a href="https://publications.waset.org/abstracts/174115/the-effect-of-exercise-therapy-and-electroacupuncture-on-some-clinical-outcomes-in-people-with-post-total-hip-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/174115.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">82</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">43</span> Dynamic Balance and Functional Performance in Total Hip Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mahmoud%20Ghazy">Mahmoud Ghazy</a>, <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20R.%20Z.%20Baghdadi"> Ahmed R. Z. Baghdadi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: With the perceived pain and poor function experienced following total hip Arthroplasty (THA), patients usually feel un-satisfied. Methods: Thirty patients with THA (group I) and thirty indicated for arthroplasty but weren’t operated on yet (group II) participated in the study. The mean age was 54.53±3.44 and 55.33±2.32 years and BMI 35.7±3.03 and 35.73±1.03 kg/m2 for group I and III respectively. The Berg Balance Scale (BBS), Timed Up-and-Go (TUG) and Stair-Climbing (SC) tests were used for assessment. Assessments were conducted four weeks pre- and post-operatively and three months post-operatively with the control group being assessed at the same time intervals. The post-operative rehabilitation involved hospitalization (1st week), home-based (2nd-4th weeks), and outpatient clinic (5th-12th weeks) programs. Results: group I had significantly lower TUG and SC time compared with group II four weeks and three months post-operatively. Moreover, the BBS scores increased significantly and the pain scores and TUG and SC time decreased significantly four weeks and three months post-operatively compared with four weeks pre- operatively in group. But no significant differences in BBS scores four weeks and three months post-operatively in group I compared with group II. Interpretation/Conclusion : Patients with THA still have defects in proprioception, so they needs more concentration on proprioception training. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=dynamic%20balance" title="dynamic balance">dynamic balance</a>, <a href="https://publications.waset.org/abstracts/search?q=functional%20performance" title=" functional performance"> functional performance</a>, <a href="https://publications.waset.org/abstracts/search?q=hip%20arthroplasty" title=" hip arthroplasty"> hip arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=total" title=" total "> total </a> </p> <a href="https://publications.waset.org/abstracts/34454/dynamic-balance-and-functional-performance-in-total-hip-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/34454.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">372</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">42</span> The Analgesic Impact of Adding Intrathecal Ketamine to Spinal Anaesthesia for Hip or Knee Arthroplasty: A Clinical Audit</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Carl%20Ashworth">Carl Ashworth</a>, <a href="https://publications.waset.org/abstracts/search?q=Matthys%20Campher"> Matthys Campher</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Spinal anaesthesia has been identified as the “gold standard” for primary elective total hip and knee arthroplasty, which is most commonly performed using longer-acting local anaesthetics, such as hyperbaric bupivacaine, to prolong the duration of anaesthesia and analgesia suitable for these procedures. Ketamine is known to have local anaesthetic effects with potent analgesic properties and has been evaluated as a sole anaesthetic agent via intrathecal administration; however, the use of intrathecal ketamine as an adjunct to intrathecal hyperbaric bupivacaine, morphine, and fentanyl has not been extensively studied. The objective of this study was to identify the potential analgesic effects of the addition of intrathecal ketamine to spinal anaesthesia and to compare the efficacy and safety of adding intrathecal ketamine to spinal anaesthesia for hip- or knee arthroplasty with spinal anaesthesia for hip- or knee arthroplasty without intrathecal ketamine. The medical records of patients who underwent elective hip- or knee arthroplasty under spinal anaesthesia performed by an individual anaesthetist with either intrathecal hyperbaric bupivacaine, morphine and fentanyl or intrathecal hyperbaric bupivacaine, morphine, fentanyl and ketamine between June 4, 2020, and June 4, 2022, were retrospectively reviewed. These encounters were reviewed and analyzed from a perioperative pain perspective, with the primary outcome measure as the oral morphine equivalent (OME) usage in the 48 hours post-spinal anaesthesia, and secondary outcome measures including time to breakthrough analgesia, self-reported pain scores at rest and during movement at 24 and 48 hours after surgery, adverse effects of analgesia, complications, and length of stay. There were 26 patients identified who underwent TKR between June 4, 2020, and June 4, 2022, and 25 patients who underwent THR with the same conditions. It was identified that patients who underwent traditional spinal anaesthesia with the addition of ketamine for elective hip- or knee arthroplasty had a lower mean total OME in the 48 hours immediately post-spinal anaesthesia yet had a shorter time to breakthrough analgesia administration. The proposed mechanism of action for intrathecal ketamine as an additive to traditional spinal anaesthesia for elective hip- or knee arthroplasty is that it may prolong and attenuate the analgesic effect of traditional spinal anaesthesia. There were no significant differences identified in comparing the efficacy and safety of adding intrathecal ketamine to spinal anaesthesia for hip- or knee arthroplasty with spinal anaesthesia for hip- or knee arthroplasty without intrathecal ketamine. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=anaesthesia" title="anaesthesia">anaesthesia</a>, <a href="https://publications.waset.org/abstracts/search?q=spinal" title=" spinal"> spinal</a>, <a href="https://publications.waset.org/abstracts/search?q=intra-thecal" title=" intra-thecal"> intra-thecal</a>, <a href="https://publications.waset.org/abstracts/search?q=ketamine" title=" ketamine"> ketamine</a>, <a href="https://publications.waset.org/abstracts/search?q=spinal-morphine" title=" spinal-morphine"> spinal-morphine</a>, <a href="https://publications.waset.org/abstracts/search?q=bupivacaine" title=" bupivacaine"> bupivacaine</a> </p> <a href="https://publications.waset.org/abstracts/173833/the-analgesic-impact-of-adding-intrathecal-ketamine-to-spinal-anaesthesia-for-hip-or-knee-arthroplasty-a-clinical-audit" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/173833.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">52</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">41</span> A Comparison of the Microbiology Profile for Periprosthetic Joint Infection (PJI) of Knee Arthroplasty and Lower Limb Endoprostheses in Tumour Surgery</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Amirul%20Adlan">Amirul Adlan</a>, <a href="https://publications.waset.org/abstracts/search?q=Robert%20A%20McCulloch"> Robert A McCulloch</a>, <a href="https://publications.waset.org/abstracts/search?q=Neil%20Jenkins"> Neil Jenkins</a>, <a href="https://publications.waset.org/abstracts/search?q=MIchael%20Parry"> MIchael Parry</a>, <a href="https://publications.waset.org/abstracts/search?q=Jonathan%20Stevenson"> Jonathan Stevenson</a>, <a href="https://publications.waset.org/abstracts/search?q=Lee%20Jeys"> Lee Jeys</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background and Objectives: The current antibiotic prophylaxis for oncological patients is based upon evidence from primary arthroplasty despite significant differences in both patient group and procedure. The aim of this study was to compare the microbiology organisms responsible for PJI in patients who underwent two-stage revision for infected primary knee replacement with those of infected oncological endoprostheses of the lower limb in a single institution. This will subsequently guide decision making regarding antibiotic prophylaxis at primary implantation for oncological procedures and empirical antibiotics for infected revision procedures (where the infecting organism(s) are unknown). Patient and Methods: 118 patients were treated with two-stage revision surgery for infected knee arthroplasty and lower limb endoprostheses between 1999 and 2019. 74 patients had two-stage revision for PJI of knee arthroplasty, and 44 had two-stage revision of lower limb endoprostheses. There were 68 males and 50 females. The mean age for the knee arthroplasty cohort and lower limb endoprostheses cohort were 70.2 years (50-89) and 36.1 years (12-78), respectively (p<0.01). Patient host and extremity criteria were categorised according to the MSIS Host and Extremity Staging System. Patient microbiological culture, the incidence of polymicrobial infection and multi-drug resistance (MDR) were analysed and recorded. Results: Polymicrobial infection was reported in 16% (12 patients) from knee arthroplasty PJI and 14.5% (8 patients) in endoprostheses PJI (p=0.783). There was a significantly higher incidence of MDR in endoprostheses PJI, isolated in 36.4% of cultures, compared to knee arthroplasty PJI (17.2%) (p=0.01). Gram-positive organisms were isolated in more than 80% of cultures from both cohorts. Coagulase-negative Staphylococcus (CoNS) was the commonest gram-positive organism, and Escherichia coli was the commonest Gram-negative organism in both groups. According to the MSIS staging system, the host and extremity grade of knee arthroplasty PJI cohort were significantly better than endoprostheses PJI(p<0.05). Conclusion: Empirical antibiotic management of PJI in orthopaedic oncology is based upon PJI in arthroplasty despite differences in both host and microbiology. Our results show a significant increase in MDR pathogens within the oncological group despite CoNS being the most common infective organism in both groups. Endoprosthetic patients presented with poorer host and extremity criteria. These factors should be considered when managing this complex patient group, emphasising the importance of broad-spectrum antibiotic prophylaxis and preoperative sampling to ensure appropriate perioperative antibiotic cover. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=microbiology" title="microbiology">microbiology</a>, <a href="https://publications.waset.org/abstracts/search?q=periprosthetic%20Joint%20infection" title=" periprosthetic Joint infection"> periprosthetic Joint infection</a>, <a href="https://publications.waset.org/abstracts/search?q=knee%20arthroplasty" title=" knee arthroplasty"> knee arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=endoprostheses" title=" endoprostheses"> endoprostheses</a> </p> <a href="https://publications.waset.org/abstracts/152707/a-comparison-of-the-microbiology-profile-for-periprosthetic-joint-infection-pji-of-knee-arthroplasty-and-lower-limb-endoprostheses-in-tumour-surgery" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/152707.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">115</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">40</span> Gait Analysis in Total Knee Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Neeraj%20Vij">Neeraj Vij</a>, <a href="https://publications.waset.org/abstracts/search?q=Christian%20Leber"> Christian Leber</a>, <a href="https://publications.waset.org/abstracts/search?q=Kenneth%20Schmidt"> Kenneth Schmidt</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: Total knee arthroplasty is a common procedure. It is well known that the biomechanics of the knee do not fully return to their normal state. Motion analysis has been used to study the biomechanics of the knee after total knee arthroplasty. The purpose of this scoping review is to summarize the current use of gait analysis in total knee arthroplasty and to identify the preoperative motion analysis parameters for which a systematic review aimed at determining the reliability and validity may be warranted. Materials and Methods: This IRB-exempt scoping review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) checklist strictly. Five search engines were searched for a total of 279 articles. Articles underwent a title and abstract screening process followed by full-text screening. Included articles were placed in the following sections: the role of gait analysis as a research tool for operative decisions, other research applications for motion analysis in total knee arthroplasty, gait analysis as a tool in predicting radiologic outcomes, gait analysis as a tool in predicting clinical outcomes. Results: Eleven articles studied gait analysis as a research tool in studying operative decisions. Motion analysis is currently used to study surgical approaches, surgical techniques, and implant choice. Five articles studied other research applications for motion analysis in total knee arthroplasty. Other research applications for motion analysis currently include studying the role of the unicompartmental knee arthroplasty and novel physical therapy protocols aimed at optimizing post-operative care. Two articles studied motion analysis as a tool for predicting radiographic outcomes. Preoperative gait analysis has identified parameters than can predict postoperative tibial component migration. 15 articles studied motion analysis in conjunction with clinical scores. Conclusions: There is a broad range of applications within the research domain of total knee arthroplasty. The potential application is likely larger. However, the current literature is limited by vague definitions of ‘gait analysis’ or ‘motion analysis’ and a limited number of articles with preoperative and postoperative functional and clinical measures. Knee adduction moment, knee adduction impulse, total knee range of motion, varus angle, cadence, stride length, and velocity have the potential for integration into composite clinical scores. A systematic review aimed at determining the validity, reliability, sensitivities, and specificities of these variables is warranted. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=motion%20analysis" title="motion analysis">motion analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=joint%20replacement" title=" joint replacement"> joint replacement</a>, <a href="https://publications.waset.org/abstracts/search?q=patient-reported%20outcomes" title=" patient-reported outcomes"> patient-reported outcomes</a>, <a href="https://publications.waset.org/abstracts/search?q=knee%20surgery" title=" knee surgery"> knee surgery</a> </p> <a href="https://publications.waset.org/abstracts/149376/gait-analysis-in-total-knee-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/149376.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">94</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">39</span> Long-Term Follow-Up of Dynamic Balance, Pain and Functional Performance in Cruciate Retaining, Posterior Stabilized Total Knee Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20R.%20Z.%20Baghdadi">Ahmed R. Z. Baghdadi</a>, <a href="https://publications.waset.org/abstracts/search?q=%C2%A0Mona%20H.%20Gamal%20Eldein"> Mona H. Gamal Eldein</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: With the perceived pain and poor function experienced following knee arthroplasty, patients usually feel unsatisfied. Yet, a controversy still persists on the appropriate operative technique that doesn’t affect proprioception much. Purpose: This study compared the effects of Cruciate Retaining (CR) and Posterior Stabilized (PS) total knee arthroplasty (TKA on dynamic balance, pain and functional performance following rehabilitation. Methods: Thirty patients with CRTKA (group I), thirty with PSTKA (group II) and fifteen indicated for arthroplasty but weren’t operated on yet (group III) participated in the study. The mean age was 54.53±3.44, 55.13±3.48 and 55.33±2.32 years and BMI 35.7±3.03, 35.7±1.99 and 35.73±1.03 kg/m2 for group I, II, and III respectively. The Berg Balance Scale (BBS), WOMAC pain subscale and Timed-Up-and-Go (TUG) and Stair-Climbing (SC) tests were used for assessment. Assessments were conducted four weeks pre- and post-operatively, three, six and twelve months post-operatively with the control group being assessed at the same time intervals. The post-operative rehabilitation involved hospitalization (1st week), home-based (2nd-4th weeks), and outpatient clinic (5th-12th weeks) programs, follow-up to all groups for twelve months. Results: The Mixed design MANOVA revealed that group I had significantly lower pain scores and SC time compared with group II three, six and twelve months post-operatively. Moreover, the BBS scores increased significantly and the pain scores and TUG and SC time decreased significantly six months post-operatively compared with four weeks pre- and post-operatively and three months post-operatively in group I and II with the opposite being true four weeks post-operatively. But no significant differences in BBS scores, pain scores and TUG and SC time between six and twelve months post-operatively in group I and II. Interpretation/Conclusion: CRTKA is preferable to PSTKA, possibly due to the preserved human proprioceptors in the un-excised PCL. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=dynamic%20balance" title="dynamic balance">dynamic balance</a>, <a href="https://publications.waset.org/abstracts/search?q=functional%20performance" title=" functional performance"> functional performance</a>, <a href="https://publications.waset.org/abstracts/search?q=knee%20arthroplasty" title=" knee arthroplasty"> knee arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=long-term" title=" long-term"> long-term</a> </p> <a href="https://publications.waset.org/abstracts/18917/long-term-follow-up-of-dynamic-balance-pain-and-functional-performance-in-cruciate-retaining-posterior-stabilized-total-knee-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/18917.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">411</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">38</span> Computer Aided Shoulder Prosthesis Design and Manufacturing </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Didem%20Venus%20Yildiz">Didem Venus Yildiz</a>, <a href="https://publications.waset.org/abstracts/search?q=Murat%20Hocaoglu"> Murat Hocaoglu</a>, <a href="https://publications.waset.org/abstracts/search?q=Murat%20Dursun"> Murat Dursun</a>, <a href="https://publications.waset.org/abstracts/search?q=Taner%20Akkan"> Taner Akkan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The shoulder joint is a more complex structure than the hip or knee joints. In addition to the overall complexity of the shoulder joint, two different factors influence the insufficient outcome of shoulder replacement: the shoulder prosthesis design is far from fully developed and it is difficult to place these shoulder prosthesis due to shoulder anatomy. The glenohumeral joint is the most complex joint of the human shoulder. There are various treatments for shoulder failures such as total shoulder arthroplasty, reverse total shoulder arthroplasty. Due to its reverse design than normal shoulder anatomy, reverse total shoulder arthroplasty has different physiological and biomechanical properties. Post-operative achievement of this arthroplasty is depend on improved design of reverse total shoulder prosthesis. Designation achievement can be increased by several biomechanical and computational analysis. In this study, data of human both shoulders with right side fracture was collected by 3D Computer Tomography (CT) machine in dicom format. This data transferred to 3D medical image processing software (Mimics Materilise, Leuven, Belgium) to reconstruct patient’s left and right shoulders’ bones geometry. Provided 3D geometry model of the fractured shoulder was used to constitute of reverse total shoulder prosthesis by 3-matic software. Finite element (FE) analysis was conducted for comparison of intact shoulder and prosthetic shoulder in terms of stress distribution and displacements. Body weight physiological reaction force of 800 N loads was applied. Resultant values of FE analysis was compared for both shoulders. The analysis of the performance of the reverse shoulder prosthesis could enhance the knowledge of the prosthetic design. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=reverse%20shoulder%20prosthesis" title="reverse shoulder prosthesis">reverse shoulder prosthesis</a>, <a href="https://publications.waset.org/abstracts/search?q=biomechanics" title=" biomechanics"> biomechanics</a>, <a href="https://publications.waset.org/abstracts/search?q=finite%20element%20analysis" title=" finite element analysis"> finite element analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=3D%20printing" title=" 3D printing"> 3D printing</a> </p> <a href="https://publications.waset.org/abstracts/116132/computer-aided-shoulder-prosthesis-design-and-manufacturing" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/116132.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">156</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">37</span> Hip Resurfacing Makes for Easier Surgery with Better Functional Outcomes at Time of Revision: A Case Controlled Study</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=O.%20O.%20Onafowokan">O. O. Onafowokan</a>, <a href="https://publications.waset.org/abstracts/search?q=K.%20Anderson"> K. Anderson</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20R.%20Norton"> M. R. Norton</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20G.%20Middleton"> R. G. Middleton</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Revision total hip arthroplasty (THA) is known to be a challenging procedure with potential for poor outcomes. Due to its lack of metaphyseal encroachment, hip resurfacing arthroplasty (HRA) is classified as a bone conserving procedure. Although the literature postulates that this is an advantage at time of revision surgery, there is no evidence to either support or refute this claim. We identified 129 hips that had undergone HRA and 129 controls undergoing first revision THA. We recorded the clinical assessment and survivorship of implants in a multi-surgeon, single centre, retrospective case control series for both arms. These were matched for age and sex. Data collected included demographics, indications for surgery, Oxford Hip Score (OHS), length of surgery, length of hospital stay, blood transfusion, implant complexity and further surgical procedures. Significance was taken as p < 0.05. Mean follow up was 7.5 years (1 to 15). There was a significant 6 point difference in postoperative OHS in favour of the revision resurfacing group (p=0.0001). The revision HRA group recorded 48 minutes less length of surgery (p<0.0001), 2 days less in length of hospital stay (p=0.018), a reduced need for blood transfusion (p=0.0001), a need for less complexity in revision implants (p=0.001) and a reduced probability of further surgery being required (P=0.003). Whilst we acknowledge the limitations of this study our results suggest that, in contrast to THA, the bone conservation element of HRA may make for a less traumatic revision procedure with better functional outcomes. Use of HRA has seen a dramatic decline as a result of concerns regarding metallosis. However, this information remains of relevance when counselling young active patients about their arthroplasty options and may become pertinent in the future if the promise of ceramic hip resurfacing is ever realized. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hip%20resurfacing" title="hip resurfacing">hip resurfacing</a>, <a href="https://publications.waset.org/abstracts/search?q=metallosis" title=" metallosis"> metallosis</a>, <a href="https://publications.waset.org/abstracts/search?q=revision%20surgery" title=" revision surgery"> revision surgery</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20hip%20arthroplasty" title=" total hip arthroplasty"> total hip arthroplasty</a> </p> <a href="https://publications.waset.org/abstracts/155848/hip-resurfacing-makes-for-easier-surgery-with-better-functional-outcomes-at-time-of-revision-a-case-controlled-study" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/155848.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">88</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">36</span> Morphometric Study of Human Anterior and Posterior Meniscofemoral Ligaments of the Knee Joint on Thiel Embalmed Cadavers</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohammad%20Alobaidy">Mohammad Alobaidy</a>, <a href="https://publications.waset.org/abstracts/search?q=David%20Nicoll"> David Nicoll</a>, <a href="https://publications.waset.org/abstracts/search?q=Tracey%20Wilkinson"> Tracey Wilkinson</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Many patients suffer postoperative knee stability after total knee arthroplasty (joint replacement) involving posterior cruciate ligament (PCL) sacrificing or retaining, but is not clear whether the meniscofemoral ligaments (MFLs) are retained during these procedures; their function in terms of knee stability is not well established in the literature. Purpose: Macroscopic, detailed, morphometric investigation of the anterior and posterior MFLs of the knee joint was undertaken to assist understanding of knee stability after total knee arthroplasty and ligament reconstruction. Methods: Dissection of eighty Thiel embalmed knees from 19 male and 21 female cadavers was conducted, mean age 77 (range 47-99 years). The origin and insertion of the anterior and posterior MFLs were measured using high accuracy, calibrated, digital Vernier calipers at 0.01mm. Results: The means were: anterior meniscofemoral ligament (aMFL) length 28.4 ± 2.7mm; posterior meniscofemoral ligament (pMFL) length 29 ± 3.7mm; aMFL femoral width 6.4 ± 1.7mm, mid-distance ligament width 4 ± 1.1mm, meniscal ligament width 3.9 ± 1.2mm; pMFL femoral width 5.6 ± 1.5mm, mid-distance ligament width 4.1 ± 1.1mm, meniscal ligament width 4.1 ± 1.3mm. Some of the male measurements were larger than female, with significant differences in the length of the aMFL femoral length p<0.01 and pMFL femoral length p<0.007, and width of the pMFL mid-distance p<0.04. Conclusion: This study may help explore the role of the meniscofemoral ligaments in knee stability after total knee arthroplasty with a posterior cruciate ligament retaining prosthesis. Anatomical information for Thiel embalmed knees may aid orthopaedic surgeons in ligament reconstruction. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=anterior%20and%20posterior%20meniscofemoral%20ligaments" title="anterior and posterior meniscofemoral ligaments">anterior and posterior meniscofemoral ligaments</a>, <a href="https://publications.waset.org/abstracts/search?q=morphometric%20analysis" title=" morphometric analysis"> morphometric analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=Thiel%20embalmed%20knees" title=" Thiel embalmed knees"> Thiel embalmed knees</a>, <a href="https://publications.waset.org/abstracts/search?q=knee%20arthroplasty" title=" knee arthroplasty"> knee arthroplasty</a> </p> <a href="https://publications.waset.org/abstracts/63427/morphometric-study-of-human-anterior-and-posterior-meniscofemoral-ligaments-of-the-knee-joint-on-thiel-embalmed-cadavers" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/63427.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">377</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">35</span> Revision of Arthroplasty in Rheumatoid and Osteoarthritis: Methotrexate and Radiographic Lucency in RA Patients</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mike%20T.%20Wei">Mike T. Wei</a>, <a href="https://publications.waset.org/abstracts/search?q=Douglas%20N.%20Mintz"> Douglas N. Mintz</a>, <a href="https://publications.waset.org/abstracts/search?q=Lisa%20A.%20Mandl"> Lisa A. Mandl</a>, <a href="https://publications.waset.org/abstracts/search?q=Arielle%20W.%20Fein"> Arielle W. Fein</a>, <a href="https://publications.waset.org/abstracts/search?q=Jayme%20C.%20Burket"> Jayme C. Burket</a>, <a href="https://publications.waset.org/abstracts/search?q=Yuo-Yu%20Lee"> Yuo-Yu Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Wei-Ti%20Huang"> Wei-Ti Huang</a>, <a href="https://publications.waset.org/abstracts/search?q=Vivian%20P.%20Bykerk"> Vivian P. Bykerk</a>, <a href="https://publications.waset.org/abstracts/search?q=Mark%20P.%20Figgie"> Mark P. Figgie</a>, <a href="https://publications.waset.org/abstracts/search?q=Edward%20F.%20Di%20Carlo"> Edward F. Di Carlo</a>, <a href="https://publications.waset.org/abstracts/search?q=Bruce%20N.%20Cronstein"> Bruce N. Cronstein</a>, <a href="https://publications.waset.org/abstracts/search?q=Susan%20M.%20Goodman"> Susan M. Goodman</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background/Purpose: Rheumatoid arthritis (RA) patients have excellent total hip arthroplasty (THA) survival, and methotrexate (MTX), an anti-inflammatory disease modifying drug which may affect bone reabsorption, may play a role. The purpose of this study is to determine the diagnosis leading to revision THA (rTHA) in RA patients and to assess the association of radiographic lucency with MTX use. Methods: All patients with validated diagnosis of RA in the institution’s THA registry undergoing rTHA from May 2007 - February 2011 were eligible. Diagnosis leading to rTHA and medication use was determined by chart review. Osteolysis was evaluated on available radiographs by measuring maximum lucency in each Gruen zone. Differences within RA patients with/without MTX in osteolysis, demographics, and medications were assessed with chi-squared, Fisher's exact tests or Mann-Whitney U tests as appropriate. The error rate for multiple comparisons of lucency in the different Gruen zones was corrected via false discovery rate methods. A secondary analysis was performed to determine differences in diagnoses leading to revision between RA and matched OA controls (2:1 match by sex age +/- 5 years). OA exclusion criteria included presence of rheumatic diseases, use of MTX, and lack of records. Results: 51 RA rTHA were identified and compared with 103 OA. Mean age for RA was 57.7 v 59.4 years for OA (p = 0.240). 82.4% RA were female v 83.5% OA (p = 0.859). RA had lower BMI than OA (25.5 v 28.2; p = 0.166). There was no difference in diagnosis leading to rTHA, including infection (RA 3.9 v OA 6.8%; p = 0.719) or dislocation (RA 23.5 v OA 23.3%; p = 0.975). There was no significant difference in the length of time the implant was in before revision: RA 11.0 v OA 8.8 years (p = 0.060). Among RA with/without MTX, there was no difference in use of biologics (30.0 v 43.3%, p = 0.283), steroids (47.6 v 50.0%, p = 0.867) or bisphosphonates (23.8 v 33.3%, p = 0.543). There was no difference in rTHA diagnosis with/without MTX, including loosening (52.4 v 56.7%, p = 0.762). There was no significant difference in lucencies with MTX use in any Gruen zone. Patients with MTX had femoral stem subsidence of 3.7mm v no subsidence without MTX (p = 0.006). Conclusion: There was no difference in the diagnosis leading to rTHR in RA and OA, although RA trended longer prior to rTHA. In this small retrospective study, there were no significant differences associated with MTX exposure or radiographic lucency among RA patients. The significance of subsidence is not clear. Further study of arthroplasty survival in RA patients is warranted. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hip%20arthroplasty" title="hip arthroplasty">hip arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=methotrexate" title=" methotrexate"> methotrexate</a>, <a href="https://publications.waset.org/abstracts/search?q=revision%20arthroplasty" title=" revision arthroplasty"> revision arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=rheumatoid%20arthritis" title=" rheumatoid arthritis"> rheumatoid arthritis</a> </p> <a href="https://publications.waset.org/abstracts/42197/revision-of-arthroplasty-in-rheumatoid-and-osteoarthritis-methotrexate-and-radiographic-lucency-in-ra-patients" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/42197.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">247</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">34</span> Impact of Preoperative Physiotherapy Care in Total Hip Arthroplasty in Slovakia and Austria</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Peter%20Kutis">Peter Kutis</a>, <a href="https://publications.waset.org/abstracts/search?q=Vladimir%20Littva"> Vladimir Littva</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Nowadays, it is necessary to ensure that this reduction in costs is not at the expense of the quality of health care and future medical success. In general, physiotherapy for total hip joint arthroplasty is considered to be a routine matter that deals mainly with mobility training, increased muscular strength, and basic day-to-day activities such as bed-to-chair transition, standing, and walking. Within the KEGA project no. 003KU-4-2021, we decided to investigate preoperative physiotherapy care in Slovakia and Austria in total hip arthroplasty patients to shortened overall recovery. Research Sample and Methods: The sample comprised 498 respondents –patients who were indicated to total hip arthroplasty on the territory of Slovakia and Austria. There were 130 women in Slovakia and 135 women in Austria. The numbers of men were 120 in Slovakia and 113 men in Austria. The age of respondents was between 40 and 85 years of age. As a method of our research, we chose a non-standardized questionnaire, which consisted of three parts. The first part for the initial examination of the patient contained the identification of the patient according to the assigned number and subsequently 19 questions conditioned by the physical examination and evaluation of the patients. The second part of our questionnaire was completed after the patient's hospitalization and contained 10 questions that were conditioned by the patient's examination. The last third part for the overall assessment of the patient's state of health consisted of 12 questions conditioned by the patient's examination. This part was performed at the last meeting with the patient at the end of the treatment. All data were statistically processed by SPSS 25. Results: All data were evaluated at a significance level of p = 0.05. From the comparison of patients who underwent preoperative preparation, we can clearly state that the total duration of treatment is significantly shorter. A t-test of two mean values with uneven variance was used to verify the validity of the assumption. The total duration of treatment in patients with preoperative preparation was on average 92,635 days and without preoperative preparation was on average 135,884 days (t-Stat = 44,52784, t Critical one-tail = 1,648187415, t Critical two-tail = 1,965157). Conclusion: The results obtained during the research show the importance of adequate preoperative physiotherapeutic preparation of the patient. The results of total hip joint arthroplasty studies showed a significant reduction in a hospital stay as well as shortened total treatment time. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=THA" title="THA">THA</a>, <a href="https://publications.waset.org/abstracts/search?q=physiotherapy" title=" physiotherapy"> physiotherapy</a>, <a href="https://publications.waset.org/abstracts/search?q=recovery" title=" recovery"> recovery</a>, <a href="https://publications.waset.org/abstracts/search?q=preoperative%20physiotherapy%20care" title=" preoperative physiotherapy care"> preoperative physiotherapy care</a> </p> <a href="https://publications.waset.org/abstracts/141859/impact-of-preoperative-physiotherapy-care-in-total-hip-arthroplasty-in-slovakia-and-austria" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/141859.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">178</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">33</span> The ‘Quartered Head Technique’: A Simple, Reliable Way of Maintaining Leg Length and Offset during Total Hip Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20Haruna">M. Haruna</a>, <a href="https://publications.waset.org/abstracts/search?q=O.%20O.%20Onafowokan"> O. O. Onafowokan</a>, <a href="https://publications.waset.org/abstracts/search?q=G.%20Holt"> G. Holt</a>, <a href="https://publications.waset.org/abstracts/search?q=K.%20Anderson"> K. Anderson</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20G.%20Middleton"> R. G. Middleton</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Requirements for satisfactory outcomes following total hip arthroplasty (THA) include restoration of femoral offset, version, and leg length. Various techniques have been described for restoring these biomechanical parameters, with leg length restoration being the most predominantly described. We describe a “quartered head technique” (QHT) which uses a stepwise series of femoral head osteotomies to identify and preserve the centre of rotation of the femoral head during THA in order to ensure reconstruction of leg length, offset and stem version, such that hip biomechanics are restored as near to normal as possible. This study aims to identify whether using the QHT during hip arthroplasty effectively restores leg length and femoral offset to within acceptable parameters. Methods: A retrospective review of 206 hips was carried out, leaving 124 hips in the final analysis. Power analysis indicated a minimum of 37 patients required. All operations were performed using an anterolateral approach by a single surgeon. All femoral implants were cemented, collarless, polished double taper CPT® stems (Zimmer, Swindon, UK). Both cemented, and uncemented acetabular components were used (Zimmer, Swindon, UK). Leg length, version, and offset were assessed intra-operatively and reproduced using the QHT. Post-operative leg length and femoral offset were determined and compared with the contralateral native hip, and the difference was then calculated. For the determination of leg length discrepancy (LLD), we used the method described by Williamson & Reckling, which has been shown to be reproducible with a measurement error of ±1mm. As a reference, the inferior margin of the acetabular teardrop and the most prominent point of the lesser trochanter were used. A discrepancy of less than 6mm LLD was chosen as acceptable. All peri-operative radiographs were assessed by two independent observers. Results: The mean absolute post-operative difference in leg length from the contralateral leg was +3.58mm. 84% of patients (104/124) had LLD within ±6mm of the contralateral limb. The mean absolute post-operative difference in offset from contralateral leg was +3.88mm (range -15 to +9mm, median 3mm). 90% of patients (112/124) were within ±6mm offset of the contralateral limb. There was no statistical difference noted between observer measurements. Conclusion: The QHT provides a simple, inexpensive yet effective method of maintaining femoral leg length and offset during total hip arthroplasty. Combining this technique with pre-operative templating or other techniques described may enable surgeons to reduce even further the discrepancies between pre-operative state and post-operative outcome. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=leg%20length%20discrepancy" title="leg length discrepancy">leg length discrepancy</a>, <a href="https://publications.waset.org/abstracts/search?q=technical%20tip" title=" technical tip"> technical tip</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20hip%20arthroplasty" title=" total hip arthroplasty"> total hip arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=operative%20technique" title=" operative technique"> operative technique</a> </p> <a href="https://publications.waset.org/abstracts/155846/the-quartered-head-technique-a-simple-reliable-way-of-maintaining-leg-length-and-offset-during-total-hip-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/155846.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">81</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">32</span> The Importance of a Coating and Architecture of the Surface Metal on the Survival of Uncemented Total Knee Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Raymond%20Puijk">Raymond Puijk</a>, <a href="https://publications.waset.org/abstracts/search?q=Rachid%20Rassir"> Rachid Rassir</a>, <a href="https://publications.waset.org/abstracts/search?q=Inger%20N.%20Sierevelt"> Inger N. Sierevelt</a>, <a href="https://publications.waset.org/abstracts/search?q=Anneke%20Spekenbrink-Sporen"> Anneke Spekenbrink-Sporen</a>, <a href="https://publications.waset.org/abstracts/search?q=Bart%20G.%20C.%20W.%20Pijls"> Bart G. C. W. Pijls</a>, <a href="https://publications.waset.org/abstracts/search?q=Rob%20G.%20H.%20H.%20Nelissen"> Rob G. H. H. Nelissen</a>, <a href="https://publications.waset.org/abstracts/search?q=Peter%20A.%20Nolte"> Peter A. Nolte</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Among uncemented total knee arthroplasty (TKA), a wide variety of metal surface structures (MSS) and coatings exist to enhance implants' biological properties (i.e., bone ingrowth). This study explores the variety of MSS-coating combinations and compares their mid-long-term survivorships with cemented TKAs, by using data from the Dutch Arthroplasty Register. Methods: A total of 235,500 cemented and 11,132 uncemented primary TKAs with a median follow-up of 5.1 years were included. MSS-coating combinations were (1) Porous-uncoated (n=8986), (2) Beaded-hydroxyapatite (HA)(n=1093), (3) Matte-uncoated (n=846), (4) Matte-Titanium-nitride (TiN) (n=207). Five- and 10-year revision-free survival for all-cause revisions, and aseptic loosening of the tibial component, were calculated and compared by using Kaplan-Meier, Log-rank tests, and multivariable Cox proportional hazard regression analyses. Results: Ten-year survival rates with all-cause revisions as an endpoint, were 94.2% for cement, and 94.7%, 96.3%, 92.1%, and 79.0% for porous-uncoated, beaded-HA, matte-uncoated, and Matte-TiN, respectively (p<0.01). Rates for aseptic loosening were 98.8% for cemented, and 98.7%, 99.8%, 97.2%, and 94.9% for the uncemented, respectively (p<0.01).The beaded-HA implants were half the risk for an all-cause revision compared to cemented implants (p<0.01). Matte-uncoated and matte-TiN implants were at more risk of an all-cause revision than cemented implants (p=0.01, p<0.01). Proportions of revisions for aseptic loosening were comparable among most groups. Conclusion: Based on Dutch registry data, four main MSS-coating combinations among uncemented TKAs were found. survivorships for all-cause revisions and aseptic release differed widely between groups. Beaded-HA and porous-uncoated implants had the best survival rates among the uncemented TKAs and were non-inferior to the cemented TKAs. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=total%20knee%20arthroplasty" title="total knee arthroplasty">total knee arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=cement" title=" cement"> cement</a>, <a href="https://publications.waset.org/abstracts/search?q=uncemented" title=" uncemented"> uncemented</a>, <a href="https://publications.waset.org/abstracts/search?q=cementless%3B" title=" cementless;"> cementless;</a>, <a href="https://publications.waset.org/abstracts/search?q=metal%20surface%20structure" title=" metal surface structure"> metal surface structure</a>, <a href="https://publications.waset.org/abstracts/search?q=coating" title=" coating"> coating</a> </p> <a href="https://publications.waset.org/abstracts/156589/the-importance-of-a-coating-and-architecture-of-the-surface-metal-on-the-survival-of-uncemented-total-knee-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/156589.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">152</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">31</span> Ultrasonography of Low Extremities Veins Before and After Replacement of Knee Joint by Endoprosthesis </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=A.%20V.%20Alabut">A. V. Alabut</a>, <a href="https://publications.waset.org/abstracts/search?q=V.%20D.%20Sikilinda"> V. D. Sikilinda</a>, <a href="https://publications.waset.org/abstracts/search?q=N.%20J.%20Nelasov"> N. J. Nelasov</a>, <a href="https://publications.waset.org/abstracts/search?q=O.%20L.%20Eroshenko"> O. L. Eroshenko</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20N.%20Morgunov"> M. N. Morgunov</a>, <a href="https://publications.waset.org/abstracts/search?q=I.%20V.%20Koroleva"> I. V. Koroleva </a> </p> <p class="card-text"><strong>Abstract:</strong></p> We have analyzed the results of treatment of 204 patients with knee prosthetic arthroplasty. For the purpose of active delineation of vascular pathology triplex sonography of arterial and venous vessels of low extremities was performed in all cases in the preoperative period. When it was necessary, reconstructive vascular surgery was implemented to improve peripheral circulation and reduce the hazard of thrombosis after knee replacement. The combination of specific and nonspecific methods of thromboprophylaxis was used in perioperative period. On 7-10 day and 2.5-3 month after prosthetic arthroplasty, all patients iteratively underwent triple sonography. In case of detection of floating thrombus, urgent venous ligation was performed. Active diagnostics of venous thrombosis gave the opportunity to avoid fatal pulmonary embolism. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=knee%20replacement" title="knee replacement">knee replacement</a>, <a href="https://publications.waset.org/abstracts/search?q=venous%20thrombosis" title=" venous thrombosis"> venous thrombosis</a>, <a href="https://publications.waset.org/abstracts/search?q=pulmonary%20embolism" title=" pulmonary embolism"> pulmonary embolism</a>, <a href="https://publications.waset.org/abstracts/search?q=vascular%20surgery" title=" vascular surgery "> vascular surgery </a> </p> <a href="https://publications.waset.org/abstracts/5218/ultrasonography-of-low-extremities-veins-before-and-after-replacement-of-knee-joint-by-endoprosthesis" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/5218.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">369</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">30</span> The Effects of Inferior Tilt Fixation on a Glenoid Components in Reverse Shoulder-Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Soo%20Min%20Kim">Soo Min Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Soo-Won%20Chae"> Soo-Won Chae</a>, <a href="https://publications.waset.org/abstracts/search?q=Soung-Yon%20Kim"> Soung-Yon Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Haea%20Lee"> Haea Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Ju%20Yong%20Kang"> Ju Yong Kang</a>, <a href="https://publications.waset.org/abstracts/search?q=Juneyong%20Lee"> Juneyong Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Seung-Ho%20Han"> Seung-Ho Han</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Reverse total shoulder arthroplasty (RTSA) has become an effective treatment option for cuff tear arthropathy and massive, irreparable rotator cuff tears and indications for its use are expanding. Numerous methods for optimal fixation of the glenoid component have been suggested, such as inferior overhang, inferior tilt, to maximize initial fixation and prevent glenoid component loosening. The inferior tilt fixation of a glenoid component has been suggested, which is expected to decrease scapular notching and to improve the stability of a glenoid component fixation in reverse total shoulder arthroplasty. Inferior tilt fixation of the glenoid component has been suggested, which can improve stability and, because it provides the most uniform compressive forces and imparts the least amount of tensile forces and micromotion, reduce the likelihood of mechanical failure. Another study reported that glenoid component inferior tilt improved impingement-free range of motion as well as minimized the scapular notching. Several authors have shown that inferior tilt of a glenoid component reduces scapular notching. However, controversy still exists regarding its importance in the literature. In this study the influence of inferior tilt fixation on the primary stability of a glenoid component has been investigated. Finite element models were constructed from cadaveric scapulae and glenoid components were implanted with neutral and 10° inferior tilts. Most previous biomechanical studies regarding the effect of glenoid component inferior tilt used a solid rigid polyurethane foam or sawbones block, not cadaveric scapulae, to evaluate the stability of the RTSA. Relative micromotions at the bone-glenoid component interface, and the distribution of bone stresses under the glenoid component and around the screws were analyzed and compared between neutral and 10° inferior tilt groups. Contact area between bone and screws and cut surface area of the cancellous bone exposed after reaming of the glenoid have also been investigated because of the fact that cancellous and cortical bone thickness vary depending on the resection level of the inferior glenoid bone. The greater relative micromotion of the bone-glenoid component interface occurred in the 10° inferior tilt group than in the neutral tilt group, especially at the inferior area of the bone-glenoid component interface. Bone stresses under the glenoid component and around the screws were also higher in the 10° inferior tilt group than in the neutral tilt group, especially at the inferior third of the glenoid bone surface under the glenoid component and inferior scapula. Thus inferior tilt fixation of the glenoid component may adversely affect the primary stability and longevity of the reverse total shoulder arthroplasty. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=finite%20element%20analysis" title="finite element analysis">finite element analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=glenoid%20component" title=" glenoid component"> glenoid component</a>, <a href="https://publications.waset.org/abstracts/search?q=inferior%20tilt" title=" inferior tilt"> inferior tilt</a>, <a href="https://publications.waset.org/abstracts/search?q=reverse%20total%20shoulder%20arthroplasty" title=" reverse total shoulder arthroplasty"> reverse total shoulder arthroplasty</a> </p> <a href="https://publications.waset.org/abstracts/44422/the-effects-of-inferior-tilt-fixation-on-a-glenoid-components-in-reverse-shoulder-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/44422.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">286</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">29</span> Malposition of Femoral Component in Total Hip Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Renate%20Krassnig">Renate Krassnig</a>, <a href="https://publications.waset.org/abstracts/search?q=Gloria%20M.%20Hohenberger"> Gloria M. Hohenberger</a>, <a href="https://publications.waset.org/abstracts/search?q=Uldis%20Berzins"> Uldis Berzins</a>, <a href="https://publications.waset.org/abstracts/search?q=Stefen%20Fischerauer"> Stefen Fischerauer</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Only a few reports discuss the effectiveness of intraoperative radiographs for placing femoral components. Therefore there is no international standard in using intraoperative imaging in the proceeding of total hip replacement. Method: Case report; an 84-year-old female patient underwent changing the components of the Total hip arthroplasty (THA) because of aseptic loosening. Due to circumstances, the surgeon decided to implant a cemented femoral component. The procedure was without any significant abnormalities. The first postoperative radiograph was planned after recovery – as usual. The x-ray imaging showed a misplaced femoral component. Therefore a CT-scan was performed additionally and the malposition of the cemented femoral component was confirmed. The patient had to undergo another surgery – removing of the cemented femoral component and implantation of a new well placed one. Conclusion: Intraoperative imaging of the femoral component is not a common standard but this case shows that intraoperative imaging is a useful method for detecting errors and gives the surgeon the opportunity to correct errors intraoperatively. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=femoral%20component" title="femoral component">femoral component</a>, <a href="https://publications.waset.org/abstracts/search?q=intraoperative%20imaging" title=" intraoperative imaging"> intraoperative imaging</a>, <a href="https://publications.waset.org/abstracts/search?q=malplacement" title=" malplacement"> malplacement</a>, <a href="https://publications.waset.org/abstracts/search?q=revison" title=" revison"> revison</a> </p> <a href="https://publications.waset.org/abstracts/88535/malposition-of-femoral-component-in-total-hip-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/88535.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">201</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">28</span> Analgesic Efficacy of IPACK Block in Primary Total Knee Arthroplasty (90 CASES)</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Fedili%20Benamar">Fedili Benamar</a>, <a href="https://publications.waset.org/abstracts/search?q=Beloulou%20Mohamed%20Lamine"> Beloulou Mohamed Lamine</a>, <a href="https://publications.waset.org/abstracts/search?q=Ouahes%20Hassane"> Ouahes Hassane</a>, <a href="https://publications.waset.org/abstracts/search?q=Ghattas%20Samir"> Ghattas Samir</a> </p> <p class="card-text"><strong>Abstract:</strong></p>  Background and aims: Peripheral regional anesthesia has been integrated into most analgesia protocols for total knee arthroplasty which considered among the most painful surgeries with a huge potential for chronicization. The adductor canal block (ACB) has gained popularity. Similarly, the IPACK block has been described to provide analgesia of the posterior knee capsule. This study aimed to evaluate the analgesic efficacy of this block in patients undergoing primary PTG. Methods: 90 patients were randomized to receive either an IPACK, an anterior sciatic block, or a sham block (30 patients in each group + multimodal analgesia and a catheter in the KCA adductor canal). GROUP 1 KCA GROUP 2 KCA+BSA GROUP 3 KCA+IPACK The analgesic blocks were done under echo-guidance preoperatively respecting the safety rules, the dose administered was 20 cc of ropivacaine 0.25% was used. We were to assess posterior knee pain 6 hours after surgery. Other endpoints included quality of recovery after surgery, pain scores, opioid requirements (PCA morphine)(EPI info 7.2 analysis). Results: -groups were matched -A predominance of women (4F/1H). -average age: 68 +/-7 years -the average BMI =31.75 kg/m2 +/- 4. -70% of patients ASA2 ,20% ASA3. -The average duration of the intervention: 89 +/- 19 minutes. -Morphine consumption (PCA) significantly higher in group 1 (16mg) & group 2 (8mg) group 3 (4mg) - The groups were matched . -There was a correlation between the use of the ipack block and postoperative pain Conclusions :In a multimodal analgesic protocol, the addition of IPACK block decreased pain scores and morphine consumption , <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=regional%20anesthesia" title="regional anesthesia">regional anesthesia</a>, <a href="https://publications.waset.org/abstracts/search?q=analgesia" title=" analgesia"> analgesia</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20knee%20arthroplasty" title=" total knee arthroplasty"> total knee arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=the%20adductor%20canal%20block%20%28acb%29" title=" the adductor canal block (acb)"> the adductor canal block (acb)</a>, <a href="https://publications.waset.org/abstracts/search?q=the%20ipack%20block" title=" the ipack block"> the ipack block</a>, <a href="https://publications.waset.org/abstracts/search?q=pain" title=" pain"> pain</a> </p> <a href="https://publications.waset.org/abstracts/174505/analgesic-efficacy-of-ipack-block-in-primary-total-knee-arthroplasty-90-cases" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/174505.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">73</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">27</span> A Next-Generation Pin-On-Plate Tribometer for Use in Arthroplasty Material Performance Research</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Lewis%20J.%20Woollin">Lewis J. Woollin</a>, <a href="https://publications.waset.org/abstracts/search?q=Robert%20I.%20Davidson"> Robert I. Davidson</a>, <a href="https://publications.waset.org/abstracts/search?q=Paul%20Watson"> Paul Watson</a>, <a href="https://publications.waset.org/abstracts/search?q=Philip%20J.%20Hyde"> Philip J. Hyde</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: In-vitro testing of arthroplasty materials is of paramount importance when ensuring that they can withstand the performance requirements encountered in-vivo. One common machine used for in-vitro testing is a pin-on-plate tribometer, an early stage screening device that generates data on the wear characteristics of arthroplasty bearing materials. These devices test vertically loaded rotating cylindrical pins acting against reciprocating plates, representing the bearing surfaces. In this study, a pin-on-plate machine has been developed that provides several improvements over current technology, thereby progressing arthroplasty bearing research. Historically, pin-on-plate tribometers have been used to investigate the performance of arthroplasty bearing materials under conditions commonly encountered during a standard gait cycle; nominal operating pressures of 2-6 MPa and an operating frequency of 1 Hz are typical. There has been increased interest in using pin-on-plate machines to test more representative in-vivo conditions, due to the drive to test 'beyond compliance', as well as their testing speed and economic advantages over hip simulators. Current pin-on-plate machines do not accommodate the increased performance requirements associated with more extreme kinematic conditions, therefore a next-generation pin-on-plate tribometer has been developed to bridge the gap between current technology and future research requirements. Methodology: The design was driven by several physiologically relevant requirements. Firstly, an increased loading capacity was essential to replicate the peak pressures that occur in the natural hip joint during running and chair-rising, as well as increasing the understanding of wear rates in obese patients. Secondly, the introduction of mid-cycle load variation was of paramount importance, as this allows for an approximation of the loads present in a gait cycle to be applied and to test the fatigue properties of materials. Finally, the rig must be validated against previous-generation pin-on-plate and arthroplasty wear data. Results: The resulting machine is a twelve station device that is split into three sets of four stations, providing an increased testing capacity compared to most current pin-on-plate tribometers. The loading of the pins is generated using a pneumatic system, which can produce contact pressures of up to 201 MPa on a 3.2 mm² round pin face. This greatly exceeds currently achievable contact pressures in literature and opens new research avenues such as testing rim wear of mal-positioned hip implants. Additionally, the contact pressure of each set can be changed independently of the others, allowing multiple loading conditions to be tested simultaneously. Using pneumatics also allows the applied pressure to be switched ON/OFF mid-cycle, another feature not currently reported elsewhere, which allows for investigation into intermittent loading and material fatigue. The device is currently undergoing a series of validation tests using Ultra-High-Molecular-Weight-Polyethylene pins and 316L Stainless Steel Plates (polished to a Ra < 0.05 µm). The operating pressures will be between 2-6 MPa, operating at 1 Hz, allowing for validation of the machine against results reported previously in the literature. The successful production of this next-generation pin-on-plate tribometer will, following its validation, unlock multiple previously unavailable research avenues. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=arthroplasty" title="arthroplasty">arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=mechanical%20design" title=" mechanical design"> mechanical design</a>, <a href="https://publications.waset.org/abstracts/search?q=pin-on-plate" title=" pin-on-plate"> pin-on-plate</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20joint%20replacement" title=" total joint replacement"> total joint replacement</a>, <a href="https://publications.waset.org/abstracts/search?q=wear%20testing" title=" wear testing"> wear testing</a> </p> <a href="https://publications.waset.org/abstracts/108967/a-next-generation-pin-on-plate-tribometer-for-use-in-arthroplasty-material-performance-research" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/108967.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">94</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">26</span> Cup-Cage Construct for Treatment of Severe Acetabular Bone Loss in Revision Total Hip Arthroplasty: Midterm Clinical and Radiographic Outcomes</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Faran%20Chaudhry">Faran Chaudhry</a>, <a href="https://publications.waset.org/abstracts/search?q=Anser%20Daud"> Anser Daud</a>, <a href="https://publications.waset.org/abstracts/search?q=Doris%20Braunstein"> Doris Braunstein</a>, <a href="https://publications.waset.org/abstracts/search?q=Oleg%20Safir"> Oleg Safir</a>, <a href="https://publications.waset.org/abstracts/search?q=Allan%20Gross"> Allan Gross</a>, <a href="https://publications.waset.org/abstracts/search?q=Paul%20Kuzyk"> Paul Kuzyk</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Acetabular reconstruction in the context of massive acetabular bone loss is challenging. In rare scenarios where the extent of bone loss precludes shell placement (cup-cage), reconstruction at our center consisted of a cage combined with highly porous metal augments. This study evaluates survivorship, complications, and functional outcomes using this technique. Methods: A total of 131 cup-cage implants (129 patients) were included in our retrospective review of revisions of total hip arthroplasty from January 2003 to January 2022. Among these cases, 100/131 (76.3%) were women, the mean age at surgery time was 68.7 years (range, 29.0 to 92.0; SD, 12.4), and the mean follow-up was 7.7 years (range, 0.02 to 20.3; SD, 5.1). Kaplan-Meier survivorship analysis was conducted with failure defined as revision surgery and/or failure of the cup-cage reconstruction. Results: A total of 30 implants (23%) reached the study endpoint involving all-cause revision. Overall survivorship was 74.8% at 10 years and 69.8% at 15 years. Reasons for revision included infection 12/131 (9.1%), dislocation 10/131 (7.6%), aseptic loosening of cup and/or cage 5/131 (3.8%), and aseptic loosening of the femoral stem 2/131 (1.5%). The mean LLD improved from 12.2 ± 15.9 mm to 3.9 ± 11.8 (p<0.05). The horizontal and vertical hip centres on plain film radiographs were significantly improved (p<0.05). Functionally, there was a decrease in the number of patients requiring the use of gait aids, with fewer patients (34, 25.9%) using a cane, walker, or wheelchair post-operatively compared to pre-operatively (58, 44%). There was a significant increase in the number of independent ambulators from 24 to 47 (36%). Conclusion: The cup-cage construct is a reliable treatment option for the treatment of various acetabular defects. There are favourable survivorship, clinical and radiographic outcomes, with a satisfactory complication rate. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=revision%20total%20hip%20arthroplasty" title="revision total hip arthroplasty">revision total hip arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=acetabular%20defect" title=" acetabular defect"> acetabular defect</a>, <a href="https://publications.waset.org/abstracts/search?q=pelvic%20discontinuity" title=" pelvic discontinuity"> pelvic discontinuity</a>, <a href="https://publications.waset.org/abstracts/search?q=trabecular%20metal%20augment" title=" trabecular metal augment"> trabecular metal augment</a>, <a href="https://publications.waset.org/abstracts/search?q=cup-cage" title=" cup-cage"> cup-cage</a> </p> <a href="https://publications.waset.org/abstracts/179286/cup-cage-construct-for-treatment-of-severe-acetabular-bone-loss-in-revision-total-hip-arthroplasty-midterm-clinical-and-radiographic-outcomes" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/179286.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">67</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">25</span> Revising Our Ideas on Revisions: Non-Contact Bridging Plate Fixation of Vancouver B1 and B2 Periprosthetic Femoral Fractures</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=S.%20Ayeko">S. Ayeko</a>, <a href="https://publications.waset.org/abstracts/search?q=J.%20Milton"> J. Milton</a>, <a href="https://publications.waset.org/abstracts/search?q=C.%20Hughes"> C. Hughes</a>, <a href="https://publications.waset.org/abstracts/search?q=K.%20Anderson"> K. Anderson</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20G.%20Middleton"> R. G. Middleton</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background: Periprosthetic femoral fractures (PFF) in association with hip hemiarthroplasty or total hip arthroplasty is a common and serious complication. In the Vancouver Classification system algorithm, B1 fractures should be treated with Open Reduction and Internal Fixation (ORIF) and preferentially revised in combination with ORIF if B2 or B3. This study aims to assess patient outcomes after plate osteosynthesis alone for Vancouver B1 and B2 fractures. The main outcome is the 1-year re-revision rate, and secondary outcomes are 30-day and 1-year mortality. Method: This is a retrospective single-centre case-series review from January 2016 to June 2021. Vancouver B1 and B2, non-malignancy fractures in adults over 18 years of age treated with polyaxial Non-Contact Bridging plate osteosynthesis, have been included. Outcomes were gathered from electronic notes and radiographs. Results: There were 50 B1 and 64 B2 fractures. 26 B2 fractures were managed with ORIF and revision, 39 ORIF alone. Of the revision group, one died within 30 days (3.8%), one at one year (3.8%), and two were revised within one year (7.7). Of the B2 ORIF group, three died within 30-day mortality (7.96%), eight at one year (21.1%), and 0 were revised in 1 year. Conclusion: This study has demonstrated that satisfactory outcomes can be achieved with ORIF, excluding revision in the management of B2 fractures. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=arthroplasty" title="arthroplasty">arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=bridging%20plate" title=" bridging plate"> bridging plate</a>, <a href="https://publications.waset.org/abstracts/search?q=periprosthetic%20fracture" title=" periprosthetic fracture"> periprosthetic fracture</a>, <a href="https://publications.waset.org/abstracts/search?q=revision%20surgery" title=" revision surgery"> revision surgery</a> </p> <a href="https://publications.waset.org/abstracts/155838/revising-our-ideas-on-revisions-non-contact-bridging-plate-fixation-of-vancouver-b1-and-b2-periprosthetic-femoral-fractures" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/155838.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">101</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">24</span> Advantages of Computer Navigation in Knee Arthroplasty</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohammad%20Ali%20Al%20Qatawneh">Mohammad Ali Al Qatawneh</a>, <a href="https://publications.waset.org/abstracts/search?q=Bespalchuk%20Pavel%20Ivanovich"> Bespalchuk Pavel Ivanovich</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Computer navigation has been introduced in total knee arthroplasty to improve the accuracy of the procedure. Computer navigation improves the accuracy of bone resection in the coronal and sagittal planes. It was also noted that it normalizes the rotational alignment of the femoral component and fully assesses and balances the deformation of soft tissues in the coronal plane. The work is devoted to the advantages of using computer navigation technology in total knee arthroplasty in 62 patients (11 men and 51 women) suffering from gonarthrosis, aged 51 to 83 years, operated using a computer navigation system, followed up to 3 years from the moment of surgery. During the examination, the deformity variant was determined, and radiometric parameters of the knee joints were measured using the Knee Society Score (KSS), Functional Knee Society Score (FKSS), and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) scales. Also, functional stress tests were performed to assess the stability of the knee joint in the frontal plane and functional indicators of the range of motion. After surgery, improvement was observed in all scales; firstly, the WOMAC values decreased by 5.90 times, and the median value to 11 points (p < 0.001), secondly KSS increased by 3.91 times and reached 86 points (p < 0.001), and the third one is that FKSS data increased by 2.08 times and reached 94 points (p < 0.001). After TKA, the axis deviation of the lower limbs of more than 3 degrees was observed in 4 patients at 6.5% and frontal instability of the knee joint just in 2 cases at 3.2%., The lower incidence of sagittal instability of the knee joint after the operation was 9.6%. The range of motion increased by 1.25 times; the volume of movement averaged 125 degrees (p < 0.001). Computer navigation increases the accuracy of the spatial orientation of the endoprosthesis components in all planes, reduces the variability of the axis of the lower limbs within ± 3 °, allows you to achieve the best results of surgical interventions, and can be used to solve most basic tasks, allowing you to achieve excellent and good outcomes of operations in 100% of cases according to the WOMAC scale. With diaphyseal deformities of the femur and/or tibia, as well as with obstruction of their medullary canal, the use of computer navigation is the method of choice. The use of computer navigation prevents the occurrence of flexion contracture and hyperextension of the knee joint during the distal sawing of the femur. Using the navigation system achieves high-precision implantation for the endoprosthesis; in addition, it achieves an adequate balance of the ligaments, which contributes to the stability of the joint, reduces pain, and allows for the achievement of a good functional result of the treatment. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=knee%20joint" title="knee joint">knee joint</a>, <a href="https://publications.waset.org/abstracts/search?q=arthroplasty" title=" arthroplasty"> arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=computer%20navigation" title=" computer navigation"> computer navigation</a>, <a href="https://publications.waset.org/abstracts/search?q=advantages" title=" advantages"> advantages</a> </p> <a href="https://publications.waset.org/abstracts/155605/advantages-of-computer-navigation-in-knee-arthroplasty" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/155605.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">90</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">23</span> Total Knee Arthroplasty in a Haemophilia: A Patient with High Titre of Inhibitor Using Recombinant Factor VIIa</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mohammad%20J.%20Mortazavi">Mohammad J. Mortazavi</a>, <a href="https://publications.waset.org/abstracts/search?q=Arvin%20Najafi"> Arvin Najafi</a>, <a href="https://publications.waset.org/abstracts/search?q=Pejman%20Mansouri"> Pejman Mansouri </a> </p> <p class="card-text"><strong>Abstract:</strong></p> Hemophilia A is simply described as deficiency of factor VIII(FVIII) and patients with this disorder have bleeding complications in different organs. By using the recombinant factor VIII in these patients, elective orthopedic surgeries have been done approximately in 40 last years. About 10-30 % of these patients have bleeding complications in their surgeries even by using recombinant factor VIII because of their inhibitor against FVIII molecule. Preoperative haemostatic management in these patients is challenging. We treated a 28-year-old male patient with hemophilia A with FVIII inhibitor which had been detected when he was14 years old (with the titer 54 Bethesda unit(BU)) scheduled for total knee arthroplasty (TKA). We use 90 µg/kg rFVIIa just before the surgery and every 2 hours during surgery. The patient did not have any significant hemorrhage during the surgery and after that. For the 2 days after surgery, the rFVIIa repeated every 2 hours as the same as preoperative dosage(90 µg/kg) and for another 2 days of postoperative admission it continued every 4 hours. After 4th day, the rFVIIa continued every 6 hours with the same dosage until the sixth day from the surgery, and finally the patient were discharged about two weeks after surgery. Seven days after the discharge, he came back for the follow up visit. On the follow up examination, the site of the surgery had neither infection hemarthroses signs. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hemophilia" title="hemophilia">hemophilia</a>, <a href="https://publications.waset.org/abstracts/search?q=factor%20VIII%20inhibitor" title=" factor VIII inhibitor"> factor VIII inhibitor</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20knee%20replacement" title=" total knee replacement"> total knee replacement</a>, <a href="https://publications.waset.org/abstracts/search?q=rFVIIa" title=" rFVIIa"> rFVIIa</a> </p> <a href="https://publications.waset.org/abstracts/37428/total-knee-arthroplasty-in-a-haemophilia-a-patient-with-high-titre-of-inhibitor-using-recombinant-factor-viia" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/37428.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">440</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">22</span> Outcomes of the Gastrocnemius Flap Performed by Orthopaedic Surgeons in Salvage Revision Knee Arthroplasty: A Retrospective Study at a Tertiary Orthopaedic Centre</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Amirul%20Adlan">Amirul Adlan</a>, <a href="https://publications.waset.org/abstracts/search?q=Robert%20McCulloch"> Robert McCulloch</a>, <a href="https://publications.waset.org/abstracts/search?q=Scott%20Evans"> Scott Evans</a>, <a href="https://publications.waset.org/abstracts/search?q=Michael%20Parry"> Michael Parry</a>, <a href="https://publications.waset.org/abstracts/search?q=Jonathan%20Stevenson"> Jonathan Stevenson</a>, <a href="https://publications.waset.org/abstracts/search?q=Lee%20Jeys"> Lee Jeys</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Background and Objectives: The gastrocnemius myofascial flap is used to manage soft-tissue defects over the anterior aspect of the knee in the context of a patient presenting with a sinus and periprosthetic joint infection (PJI) or extensor mechanism failure. The aim of this study was twofold: firstly, to evaluate the outcomes of gastrocnemius flaps performed by appropriately trained orthopaedic surgeons in the context of PJI and, secondly, to evaluate the infection-free survival of this patient group. Methods: We retrospectively reviewed 30 patients who underwent gastrocnemius flap reconstruction during staged revision total knee arthroplasty for prosthetic joint infection (PJI). All flaps were performed by an orthopaedic surgeon with orthoplastics training. Patients had a mean age of 68.9 years (range 50–84) and were followed up for a mean of 50.4 months (range 2–128 months). A total of 29 patients (97 %) were categorized into Musculoskeletal Infection Society (MSIS) local extremity grade 3 (greater than two compromising factors), and 52 % of PJIs were polymicrobial. The primary outcome measure was flap failure, and the secondary outcome measure was a recurrent infection. Results: Flap survival was 100% with no failures or early returns to theatre for flap problems such as necrosis or haematoma. Overall infection-free survival during the study period was 48% (13 of 27 infected cases). Using limb salvage as the outcome, 77% (23 of 30 patients) retained the limb. Infection recurrence occurred in 48% (10 patients) in the type B3 cohort and 67% (4 patients) in the type C3 cohort (p = 0.65). Conclusion: The surgical technique for a gastrocnemius myofascial flap is reliable and reproducible when performed by appropriately trained orthopaedic surgeons, even in high-risk groups. However, the risks of recurrent infection and amputation remain high within our series due to poor host and extremity factors. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=gastrocnemius%20flap" title="gastrocnemius flap">gastrocnemius flap</a>, <a href="https://publications.waset.org/abstracts/search?q=limb%20salvage" title=" limb salvage"> limb salvage</a>, <a href="https://publications.waset.org/abstracts/search?q=revision%20arthroplasty" title=" revision arthroplasty"> revision arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=outcomes" title=" outcomes"> outcomes</a> </p> <a href="https://publications.waset.org/abstracts/152704/outcomes-of-the-gastrocnemius-flap-performed-by-orthopaedic-surgeons-in-salvage-revision-knee-arthroplasty-a-retrospective-study-at-a-tertiary-orthopaedic-centre" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/152704.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">111</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">21</span> Hybrid versus Cemented Fixation in Total Knee Arthroplasty: Mid-Term Follow-Up</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Pedro%20Gomes">Pedro Gomes</a>, <a href="https://publications.waset.org/abstracts/search?q=Lu%C3%ADs%20S%C3%A1%20Castelo"> Luís Sá Castelo</a>, <a href="https://publications.waset.org/abstracts/search?q=Ant%C3%B3nio%20Lopes"> António Lopes</a>, <a href="https://publications.waset.org/abstracts/search?q=Marta%20Maio"> Marta Maio</a>, <a href="https://publications.waset.org/abstracts/search?q=Pedro%20Mota"> Pedro Mota</a>, <a href="https://publications.waset.org/abstracts/search?q=Ad%C3%A9lia%20Avelar"> Adélia Avelar</a>, <a href="https://publications.waset.org/abstracts/search?q=Ant%C3%B3nio%20Marques%20Dias"> António Marques Dias</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: Total Knee Arthroplasty (TKA) has contributed to improvement of patient`s quality of life, although it has been associated with some complications including component loosening and polyethylene wear. To prevent these complications various fixation techniques have been employed. Hybrid TKA with cemented tibial and cementless femoral components have shown favourable outcomes, although it still lack of consensus in the literature. Objectives: To evaluate the clinical and radiographic results of hybrid versus cemented TKA with an average 5 years follow-up and analyse the survival rates. Methods: A retrospective study of 125 TKAs performed in 92 patients at our institution, between 2006 to 2008, with a minimum follow-up of 2 years. The same prosthesis was used in all knees. Hybrid TKA fixation was performed in 96 knees, with a mean follow-up of 4,8±1,7 years (range, 2–8,3 years) and 29 TKAs received fully cemented fixation with a mean follow-up of 4,9±1,9 years (range, 2-8,3 years). Selection for hybrid fixation was nonrandomized and based on femoral component fit. The Oxford Knee Score (OKS 0-48) was evaluated for clinical assessment and Knee Society Roentgenographic Evaluation Scoring System was used for radiographic outcome. The survival rate was calculated using the Kaplan-Meier method, with failures defined as revision of either the tibial or femoral component for aseptic failures and all-causes (aseptic and infection). Analysis of survivorship data was performed using the log-rank test. SPSS (v22) was the computer program used for statistical analysis. Results: The hybrid group consisted of 72 females (75%) and 24 males (25%), with mean age 64±7 years (range, 50-78 years). The preoperative diagnosis was osteoarthritis (OA) in 94 knees (98%), rheumatoid arthritis (RA) in 1 knee (1%) and Posttraumatic arthritis (PTA) in 1 Knee (1%). The fully cemented group consisted of 23 females (79%) and 6 males (21%), with mean age 65±7 years (range, 47-78 years). The preoperative diagnosis was OA in 27 knees (93%), PTA in 2 knees (7%). The Oxford Knee Scores were similar between the 2 groups (hybrid 40,3±2,8 versus cemented 40,2±3). The percentage of radiolucencies seen on the femoral side was slightly higher in the cemented group 20,7% than the hybrid group 11,5% p0.223. In the cemented group there were significantly more Zone 4 radiolucencies compared to the hybrid group (13,8% versus 2,1% p0,026). Revisions for all causes were performed in 4 of the 96 hybrid TKAs (4,2%) and 1 of the 29 cemented TKAs (3,5%). The reason for revision was aseptic loosening in 3 hybrid TKAs and 1 of the cemented TKAs. Revision was performed for infection in 1 hybrid TKA. The hybrid group demonstrated a 7 years survival rate of 93% for all-cause failures and 94% for aseptic loosening. No significant difference in survivorship was seen between the groups for all-cause failures or aseptic failures. Conclusions: Hybrid TKA yields similar intermediate-term results and survival rates as fully cemented total knee arthroplasty and remains a viable option in knee joint replacement surgery. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=hybrid" title="hybrid">hybrid</a>, <a href="https://publications.waset.org/abstracts/search?q=survival%20rate" title=" survival rate"> survival rate</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20knee%20arthroplasty" title=" total knee arthroplasty"> total knee arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=orthopaedic%20surgery" title=" orthopaedic surgery"> orthopaedic surgery</a> </p> <a href="https://publications.waset.org/abstracts/25219/hybrid-versus-cemented-fixation-in-total-knee-arthroplasty-mid-term-follow-up" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/25219.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">594</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">20</span> Surgical Prep-Related Burns in Laterally Positioned Hip Procedures</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=B.%20Kenny">B. Kenny</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20%20Dixon"> M. Dixon</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Boshell"> A. Boshell</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The use of alcoholic surgical prep was recently introduced into the Royal Newcastle Center for elective procedures. In the past 3 months there have been a significant number of burns believed to be related to ‘pooling’ of this surgical prep in patients undergoing procedures where they are placed in the lateral position with hip bolsters. The aim of the audit was to determine the reason for the burns, analyze what pre-existing factors may contribute to the development of the burns and what can be changed to prevent further burns occurring. All patients undergoing a procedure performed on the hip who were placed in the lateral position with sacral and anterior, superior iliac spine (ASIS) support with ‘bolsters’ were included in the audit. Patients who developed a ‘burn’ were recorded, details of the surgery, demographics, surgical prep used and length of surgery were obtained as well as photographs taken to document the burn. Measures were then taken to prevent further burns and the efficacy was documented. Overall 14 patients developed burns over the ipsilateral ASIS. Of these, 13 were Total Hip Arthroplasty (THA) and 1 was a removal of femoral nail. All patients had Chlorhexidine 0.5% in Alcohol 70% Tinted Red surgical preparation or Betadine Alcoholic Skin Prep (70% etoh). Patients were set up in the standard lateral decubitus position with sacral and bilateral ASIS bolsters with a valband covering. 86% of patients were found to have pre-existing hypersensitivities to various substances. There is very little literature besides a few case reports on surgical prep-related burns. The case reports that do exist are related to the use of tourniquet-related burns and there is no mention in the literature examining ‘bolster’ related burns. The burns are hypothesized to be caused by pooling of the alcoholic solution which is amplified by the use of Valband. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=arthroplasty" title="arthroplasty">arthroplasty</a>, <a href="https://publications.waset.org/abstracts/search?q=chemical%20burns" title=" chemical burns"> chemical burns</a>, <a href="https://publications.waset.org/abstracts/search?q=wounds" title=" wounds"> wounds</a>, <a href="https://publications.waset.org/abstracts/search?q=rehabilitation" title=" rehabilitation"> rehabilitation</a> </p> <a href="https://publications.waset.org/abstracts/20980/surgical-prep-related-burns-in-laterally-positioned-hip-procedures" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/20980.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">300</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">19</span> Plantar Neuro-Receptor Activation in Total Knee Arthroplasty Patients: Impact on Clinical Function, Pain, and Stiffness - A Randomized Controlled Trial</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Woolfrey%20K.">Woolfrey K.</a>, <a href="https://publications.waset.org/abstracts/search?q=Woolfrey%20M."> Woolfrey M.</a>, <a href="https://publications.waset.org/abstracts/search?q=Bolton%20C.%20L."> Bolton C. L.</a>, <a href="https://publications.waset.org/abstracts/search?q=Warchuk%20D."> Warchuk D.</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Objectives: Osteoarthritis is the most common joint disease of adults worldwide. Despite total knee arthroplasty (TKA) demonstrating high levels of success, 20% of patients report dissatisfaction with their result. VOXX Wellness Stasis Socks are embedded with a proprietary pattern of neuro-receptor activation points that have been proven to activate a precise neuro-response, according to the pattern theory of haptic perception, which stimulates improvements in pain and function. The use of this technology in TKA patients may prove beneficial as an adjunct to recovery as many patients suffer from deficits to their proprioceptive system caused by ligamentous damage and alterations to mechanoreceptors during the procedure. We hypothesized that VOXX Wellness Stasis Socks are a safe, cost-effective, and easily scalable strategy to support TKA patients through their recovery. Design: Double-blinded, placebo-controlled randomized trial. Participants: Patients scheduled to receive TKA were considered eligible for inclusion in the trial. Interventions: Intervention group (I): VOXX Wellness Stasis socks containing receptor point-activation technology. Control group (C): VOXX Wellness Stasis socks without receptor point-activation technology. Sock use during the waking hours x 6 weeks. Main Outcome Measures: Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) questionnaire completed at baseline, 2 weeks, and 6 weeks to assess pain, stiffness, and physical function. Results: Data analysis using SPSS software. P-values, effect sizes, and confidence intervals are reported to assess clinical relevance of the finding. Physical status classifications were compared using t-test. Within-subject and between-subject differences in the mean WOMAC were analyzed by ANOVA. Effect size was analyzed using Cramer’s V. Consistent improvement in WOMAC scores for pain and stiffness at 2 weeks post op in the I over the C group. The womac scores assessing physical function showed a consistent improvement at both 2 and 6 weeks post op in the I group compared to C group. Conclusions: VOXX proved to be a low cost, safe intervention in TKA to help patients improve with regard to pain, stiffness, and physical function. Disclosures: None <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=osteoarthritis" title="osteoarthritis">osteoarthritis</a>, <a href="https://publications.waset.org/abstracts/search?q=RCT" title=" RCT"> RCT</a>, <a href="https://publications.waset.org/abstracts/search?q=pain%20management" title=" pain management"> pain management</a>, <a href="https://publications.waset.org/abstracts/search?q=total%20knee%20arthroplasty" title=" total knee arthroplasty"> total knee arthroplasty</a> </p> <a href="https://publications.waset.org/abstracts/149308/plantar-neuro-receptor-activation-in-total-knee-arthroplasty-patients-impact-on-clinical-function-pain-and-stiffness-a-randomized-controlled-trial" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/149308.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">531</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">18</span> A Comparison and Discussion of Modern Anaesthetic Techniques in Elective Lower Limb Arthroplasties</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=P.%20T.%20Collett">P. T. Collett</a>, <a href="https://publications.waset.org/abstracts/search?q=M.%20Kershaw"> M. Kershaw</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: The discussion regarding which method of anesthesia provides better results for lower limb arthroplasty is a continuing debate. Multiple meta-analysis has been performed with no clear consensus. The current recommendation is to use neuraxial anesthesia for lower limb arthroplasty; however, the evidence to support this decision is weak. The Enhanced Recovery After Surgery (ERAS) society has recommended, either technique can be used as part of a multimodal anesthetic regimen. A local study was performed to see if the current anesthetic practice correlates with the current recommendations and to evaluate the efficacy of the different techniques utilized. Method: 90 patients who underwent total hip or total knee replacements at Nevill Hall Hospital between February 2019 to July 2019 were reviewed. Data collected included the anesthetic technique, day one opiate use, pain score, and length of stay. The data was collected from anesthetic charts, and the pain team follows up forms. Analysis: The average of patients undergoing lower limb arthroplasty was 70. Of those 83% (n=75) received a spinal anaesthetic and 17% (n=15) received a general anaesthetic. For patients undergoing knee replacement under general anesthetic the average day, one pain score was 2.29 and 1.94 if a spinal anesthetic was performed. For hip replacements, the scores were 1.87 and 1.8, respectively. There was no statistical significance between these scores. Day 1 opiate usage was significantly higher in knee replacement patients who were given a general anesthetic (45.7mg IV morphine equivalent) vs. those who were operated on under spinal anesthetic (19.7mg). This difference was not noticeable in hip replacement patients. There was no significant difference in length of stay between the two anesthetic techniques. Discussion: There was no significant difference in the day one pain score between the patients who received a general or spinal anesthetic for either knee or hip replacements. The higher pain scores in the knee replacement group overall are consistent with this being a more painful procedure. This is a small patient population, which means any difference between the two groups is unlikely to be representative of a larger population. The pain scale has 4 points, which means it is difficult to identify a significant difference between pain scores. Conclusion: There is currently little standardization between the different anesthetic approaches utilized in Nevill Hall Hospital. This is likely due to the lack of adherence to a standardized anesthetic regimen. In accordance with ERAS recommends a standard anesthetic protocol is a core component. The results of this study and the guidance from the ERAS society will support the implementation of a new health board wide ERAS protocol. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=anaesthesia" title="anaesthesia">anaesthesia</a>, <a href="https://publications.waset.org/abstracts/search?q=orthopaedics" title=" orthopaedics"> orthopaedics</a>, <a href="https://publications.waset.org/abstracts/search?q=intensive%20care" title=" intensive care"> intensive care</a>, <a href="https://publications.waset.org/abstracts/search?q=patient%20centered%20decision%20making" title=" patient centered decision making"> patient centered decision making</a>, <a href="https://publications.waset.org/abstracts/search?q=treatment%20escalation" title=" treatment escalation"> treatment escalation</a> </p> <a href="https://publications.waset.org/abstracts/128806/a-comparison-and-discussion-of-modern-anaesthetic-techniques-in-elective-lower-limb-arthroplasties" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/128806.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">127</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">17</span> Comparison of the Proprioception Sense and Standing Balance in Patients with Osteoarthritis Before and After Total Knee Arthroplasty Surgery</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=S.%20Daneshi">S. Daneshi</a>, <a href="https://publications.waset.org/abstracts/search?q=G.%20Shahcheraghi"> G. Shahcheraghi</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20Ghaffarinejad"> F. Ghaffarinejad</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Back ground: Osteoarthritis (OA) is the most common form of arthritis, affecting millions of people around the world during the aging process. Knee joint proprioception sense decrease with OA and Total Knee Arthroplasty (TKA) surgery may affect them. We investigated two parameters of proprioception sense (the joint position sense and kinesthesia) and standing balance in affected limbs before and after TKA, in patient with Knee OA. Methods and Materials: In this Analytic study, 10 patients who were candidate for TKA during two months in Dena Hospital of Shiraz, selected for further analysis. All of cases were female in range of 55-70 years old. Participants assessed before and two weeks after TKA using three instruments: electrogoniometer and continuous passive motion (CPM) to assess Knee joint position sense and kinesthesia in 20 and 45 degrees; and chronometer to assess duration of standing balance on affected leg with open and closed eyes. Results: To examine differences between before and after of TKA scorings Willcoxon Signed Rank and Mann-Whitney was performed which indicated no significant differences between knee joint position sense and kinesthesia in 20 and 45 degrees (P>0.05) and no significant differences between Standing Balance in a patient with knee OA before and after TKA (P>0.05). Conclusion: The study indicates that, OA can affect proprioception sense and standing balance but TKA doesn’t have any effect on these parameters. Intra articular structures such as cruciate ligaments and mines are responsible for proprioception sense in normal knee joint. Since in severe knee OA the number of mechanoreceptors in these intra articular structures decrease and their function reduce more than normal knee joint, so the anterior cruciate ligaments (ACL) become defected, thus after TKA surgery which this ligament is removed no significant change was found in proprioception sense. As a result of involving proprioception sense, muscles strength and the function of vestibular system in balance, standing balance did not show significant difference before and after TKA. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=knee%20joint" title="knee joint">knee joint</a>, <a href="https://publications.waset.org/abstracts/search?q=proprioception%20sense" title=" proprioception sense"> proprioception sense</a>, <a href="https://publications.waset.org/abstracts/search?q=standing%20balance" title=" standing balance"> standing balance</a>, <a href="https://publications.waset.org/abstracts/search?q=rehabilitation%20sciences" title=" rehabilitation sciences"> rehabilitation sciences</a> </p> <a href="https://publications.waset.org/abstracts/3742/comparison-of-the-proprioception-sense-and-standing-balance-in-patients-with-osteoarthritis-before-and-after-total-knee-arthroplasty-surgery" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/3742.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">380</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">16</span> An Intelligent Steerable Drill System for Orthopedic Surgery</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Wei%20Yao">Wei Yao</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A steerable and flexible drill is needed in orthopaedic surgery. For example, osteoarthritis is a common condition affecting millions of people for which joint replacement is an effective treatment which improves the quality and duration of life in elderly sufferers. Conventional surgery is not very accurate. Computer navigation and robotics can help increase the accuracy. For example, In Total Hip Arthroplasty (THA), robotic surgery is currently practiced mainly on acetabular side helping cup positioning and orientation. However, femoral stem positioning mostly uses hand-rasping method rather than robots for accurate positioning. The other case for using a flexible drill in surgery is Anterior Cruciate Ligament (ACL) Reconstruction. The majority of ACL Reconstruction failures are primarily caused by technical mistakes and surgical errors resulting from drilling the anatomical bone tunnels required to accommodate the ligament graft. The proposed new steerable drill system will perform orthopedic surgery through curved tunneling leading to better accuracy and patient outcomes. It may reduce intra-operative fractures, dislocations, early failure and leg length discrepancy by making possible a new level of precision. This technology is based on a robotically assisted, steerable, hand-held flexible drill, with a drill-tip tracking device and a multi-modality navigation system. The critical differentiator is that this robotically assisted surgical technology now allows the surgeon to prepare 'patient specific' and more anatomically correct 'curved' bone tunnels during orthopedic surgery rather than drilling straight holes as occurs currently with existing surgical tools. The flexible and steerable drill and its navigation system for femoral milling in total hip arthroplasty had been tested on sawbones to evaluate the accuracy of the positioning and orientation of femoral stem relative to the pre-operative plan. The data show the accuracy of the navigation system is better than traditional hand-rasping method. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=navigation" title="navigation">navigation</a>, <a href="https://publications.waset.org/abstracts/search?q=robotic%20orthopedic%20surgery" title=" robotic orthopedic surgery"> robotic orthopedic surgery</a>, <a href="https://publications.waset.org/abstracts/search?q=steerable%20drill" title=" steerable drill"> steerable drill</a>, <a href="https://publications.waset.org/abstracts/search?q=tracking" title=" tracking"> tracking</a> </p> <a href="https://publications.waset.org/abstracts/94187/an-intelligent-steerable-drill-system-for-orthopedic-surgery" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/94187.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">167</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">&lsaquo;</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=hip%20arthroplasty&amp;page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=hip%20arthroplasty&amp;page=2" rel="next">&rsaquo;</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">&copy; 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">&times;</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>

Pages: 1 2 3 4 5 6 7 8 9 10