CINXE.COM
Off-axis and tilted element telescopes 1
<html xmlns:v="urn:schemas-microsoft-com:vml" xmlns:o="urn:schemas-microsoft-com:office:office" xmlns="http://www.w3.org/TR/REC-html40"> <head><meta name="viewport" content="width=device-width, initial-scale=1"> <meta http-equiv="Content-Type" content="text/html; charset=windows-1252"> <meta http-equiv="Content-Language" content="en-us"> <title>Off-axis and tilted element telescopes 1</title> <meta name="keywords" content="Herschelian, unobstructed reflector, tilted component telescopes"> <meta name="description" content="Herschelian reflector, description, illustration and optical formulae."> <link rel="File-List" href="tilted2_files/filelist.xml"> <style fprolloverstyle>A:hover {color: #FF8204} </style> <!--[if !mso]> <style> v\:* { behavior: url(#default#VML) } o\:* { behavior: url(#default#VML) } .shape { behavior: url(#default#VML) } div.Section1 {page:Section1;} </style> <![endif]--><!--[if gte mso 9]> <xml><o:shapedefaults v:ext="edit" spidmax="1027"/> </xml><![endif]--> </head> <body link="#0000FF" vlink="#993399" alink="#FF0000" style="font-family: Verdana; font-size: 10px" bgcolor="#F4F4DF"> <div align="center"> <table border="0" cellpadding="0" cellspacing="0" width="800" height="770" bgcolor="#FFE066"> <!-- MSTableType="layout" --> <tr> <td valign="top" height="704" style="text-indent: 21; padding-left:21px; padding-right:21px; padding-top:21px; padding-bottom:3px; border-left-style:solid; border-left-width:0px; border-right-style:solid; border-right-width:0px; border-top-style:solid; border-top-width:0px"> <!-- MSCellType="ContentBody" --> <p align="center" style="text-indent: 0"> <b><font size="3" color="#518FBD" face="Verdana">telescope</font></b><font face="Microsoft Sans Serif" size="5" color="#518FBD">Ѳ</font><b><font size="3" face="Verdana" color="#518FBD">ptics.net</font><font face="Verdana" color="#95AAA6" size="3"> </font></b> <font size="1" color="#95AAA6">▪</font><font color="#95AAA6"><b> </b> </font><b><font face="Verdana" color="#95AAA6" size="3"> </font></b> <font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font> <font size="1" color="#95AAA6">▪</font><font face="Verdana" color="#95AAA6"><b><font size="2"> </font></b><font size="1"> </font></font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪▪▪▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font size="1" color="#95AAA6">▪</font><font size="1" face="Verdana" color="#95AAA6"> </font><font face="Verdana" color="#518FBD"><b><font size="2"> </font></b></font><font face="Verdana"><span style="font-weight: 400"><font size="2"><a href="index.htm#TABLE_OF_CONTENTS">CONTENTS</a></font></span></font><font size="2"><span style="font-weight: 400"><font size="2" face="Arial"><br> </font></span></p> <p align="center" style="text-indent: 0"> <span style="font-weight: 400"> <font size="2" face="Arial" color="#336699">◄</font></span><font face="Verdana" size="2"> <a href="paul-baker_telescope.htm">8.3.1. Paul-Baker, flat-field anastigmatic aplanats</a> </font><font size="2" face="Arial"><font color="#C0C0C0"> ▐</font> </font><font face="Verdana" size="2"> <a href="tilted_component_telescopes.htm">8.4.2. Two-mirror TCT</a> </font> <font face="Arial" size="2" color="#336699">►</font><br> </p> <h1 align="center" style="text-indent: 0"> <span style="font-weight: 400"> <font face="Trebuchet MS" size="3" color="#336699"><b>8.4. <span style="text-transform: uppercase">Off-axis and tilted component telescopes; Herschelian reflector </b></span> </font></span></h1> <p align="justify" style="line-height: 150%"><font face="Verdana" size="2">Axially symmetric reflective telescopes have disadvantage of the smaller mirror being in the light path, causing additional diffraction effect degrading image quality. In order to avoid it, one or more mirrors either have to be tilted, or made as an off-axis segment of a larger system. Mirror tilt induces severe coma and astigmatism, hard to control, except at relatively small apertures. Off-axis systems, on the other side, have better control of aberrations, but are limited in size by production difficulties and/or price. Consequently, both, tilted optics and <br> off-axis section systems are limited to relatively small, long-focus systems.</font></font><p align="center" style="text-indent: 0"> <b> <font face="Trebuchet MS" color="#336699" size="3"> 8.4.1. Herschelian reflector</font></b><font size="2"> <p align="justify" style="line-height: 150%"> <font face="Verdana" size="2">The simplest unobstructed reflecting system is so-called Herschelian reflector, used by the great German/British astronomer of the late 18th and early 19th century, Sir William Herschel. In order to prevent additional light loss on an extra mirror surface of - back then - very low reflectivity, Herschel tilted the primary enough to bring the focus out of incoming light, with the eyepiece mounted on the side of an oversized tube. While it eliminates central obstruction effect and the light loss, mirror tilt results in significant image deterioration. It is possible that Herschel partly corrected for it by tilting the eyepiece, but the design still suffers from aberrations, as well as air turbulence caused by warmth off the observers head, placed next to the path of the incoming air. The more recent variant, with the side flat mirror directing image plane away from the tube eliminates that problem (<b>FIG. 132</b>), but a very long-focus mirror is still required in order to keep aberrations at an acceptable level. </font> <p><!--[if gte vml 1]><v:line id="_x0000_s1025" style='position:absolute;left:0;text-align:left;top:0;z-index:6' from="624pt,398.25pt" to="624pt,398.25pt"/><![endif]--><![if !vml]><span style='mso-ignore:vglayout; position:absolute;z-index:6;left:831px;top:530px;width:2px;height:2px'><img width=2 height=2 src="tilted2_files/image001.gif" v:shapes="_x0000_s1025"></span><![endif]><div style="padding-left:4px; padding-right:3px; background-color:#FFFFFF"> <p align="center" style="text-indent: 0"> <img border="0" src="images/29.PNG" width="717" height="162" hspace="10"> <b> <font SIZE="2" face="Arial">FIGURE </font><font face="Arial">132</font></b><font SIZE="2" face="Arial">: Modern version of the Herschelian reflector, with the primary tilted by an angle </font><b><font face="Georgia" size="2">τ</font></b><font SIZE="2" face="Arial">, and a small reflecting flat placed out of the path of incoming light to direct converging cone to the side, for more convenient eyepiece position. In order to keep tilt-induced aberrations low, the primary is of a very small relative aperture.</div> </div> </font><p align="justify" style="line-height: 150%"> <font face="Verdana" size="2">Small long-focus mirrors can be left spherical, since their spherical aberration is negligible. However, the tilt-induced center-field astigmatism and coma still can cause unacceptable image deterioration. The mirror tilt angle </font><b> <font face="Georgia" size="2">τ</font></b><font face="Verdana" size="2"> will result in the P-V wavefront error of astigmatism <b>W</b></font><b><font face="Terminal" size="1"><span style="vertical-align: sub">a</span></font><font face="Verdana" size="2">=</font><font face="Georgia" size="2">τ</font><font face="Verdana" size="1"><span style="vertical-align: super">2</span></font></b><font face="Verdana" size="2"><b>D/8F</b> (from <a href="astigmatism1.htm#(18)">Eq. 18</a>), and the coma P-V wavefront error of<b> W</b></font><b><font face="Terminal" size="1"><span style="vertical-align: sub">c</span></font><font face="Verdana" size="2">=</font><font face="Georgia" size="2">τ</font><font face="Verdana" size="2">D/48F</font><font face="Verdana" size="1"><span style="vertical-align: super">2</span></font></b><font face="Verdana" size="2"> (from <a href="coma.htm#Aberration_function">Eq. 12-15.1</a>), both at their respective diffraction foci. If <b>ζ</b> is the relative distance in units of the primary focal length at which the ray reflected from the mirror center breaks out of the path of incoming axial pencil (<b>FIG. 85</b>), then the tilt angle </font><font face="Georgia" size="2">τ</font><font face="Verdana" size="2">=1/4ζF in radians, and the two can be written as: </font> <p align="center" style="text-indent: 0"> </font> <font face="Comic Sans MS">W</font><b><font face="Terminal" size="1"><span style="vertical-align: sub">a</span></font></b><font face="Comic Sans MS">=D/128</font><b><font size="2"><font face="Verdana" size="2">ζ</font><font face="Verdana" size="1"><span style="vertical-align: super">2</span></font></font></b><font face="Comic Sans MS">F</font><b><font face="Verdana" size="1"><span style="vertical-align: super">3</span></font></b><font size="2"><font face="Verdana" size="2"> </font><font face="Comic Sans MS" size="2">and</font><font face="Verdana" size="2"> <b> </b></font></font> <font face="Comic Sans MS">W</font><font size="2"><b><font face="Terminal" size="1"><span style="vertical-align: sub">c</span></font></b></font><font face="Comic Sans MS">=D/192</font><b><font face="Verdana" size="2">ζ</font></b><font face="Comic Sans MS">F</font><b><font face="Verdana" size="1"><span style="vertical-align: super">3</span></font></b><font size="2"><font face="Verdana" size="2">. </font><font face="Comic Sans MS" size="2">(93)</font><p align="justify" style="text-indent: 0; line-height:150%"> <font face="Verdana" size="2"><b>D</b> being the aperture diameter and <b>F</b> the focal ratio. Setting the minimum flat separation at 1" between the incoming axial pencil and the flat center point (giving ~1" usable field diameter), the relative distance <b>ζ</b> is given by ζ=(f-D-4)/(D+2)F with </font><b> f</b><font face="Verdana" size="2">, <b>D</b> and <b>F</b> being the mirror focal length, diameter (in inches) and focal ratio, respectively. For mm, ζ=(f-D-100)/(D+50)F. Between 100mm </font> <font face="Tahoma" size="2">f</font><font face="Verdana" size="2">/20 and 150mm </font> <font face="Tahoma" size="2">f</font><font face="Verdana" size="2">/25, <b>ζ </b> varies from 0.6 to 0.7, respectively. </font> <p align="justify" style="line-height: 150%"> <font face="Verdana" size="2">Since ζ<1, <b>Eq. 93</b> indicates that the astigmatism is dominant, with the P-V wavefront error larger by a factor of 1.5/ζ than that for the coma. To make them comparable, the two P-V errors need to be expressed as RMS, which are smaller by a factor of </font><b><font size="2" face="Verdana">√</font></b><span style="text-decoration: overline"><font face="Verdana" size="2">24</font></span><font face="Verdana" size="2"> and </font><b><font size="2" face="Verdana">√</font></b><span style="text-decoration: overline"><font face="Verdana" size="2">32</font></span><font face="Verdana" size="2"> for astigmatism and coma, respectively. Then, needed mirror focal ratio <b>F</b> for any given RMS wavefront error <b>ω</b></font><b><font face="Terminal" size="1"><span style="vertical-align: sub">a</span></font></b><font face="Verdana" size="2"> of astigmatism introduced to the field center is given by<b> <br> F=(D/128</b></font><b><font face="Verdana" size="2">ω</font><font face="Terminal" size="1"><span style="vertical-align: sub">a</span></font><font face="Verdana" size="2">ζ</font></b><font face="Verdana" size="1"><span style="vertical-align: super; font-weight: 700">2</span></font><b><font size="2" face="Verdana">√</font></b><span style="text-decoration: overline"><font face="Verdana" size="2"><b>24</b></font></span><b><font face="Verdana" size="2">)</font><font face="Verdana" size="1"><span style="vertical-align: super">1/3</span></font></b><font face="Verdana" size="2">.</font><p align="justify" style="line-height: 150%"> <font face="Verdana" size="2">For D=100mm aperture diameter, ζ=0.6 and ω</font><font face="Terminal" size="1"><span style="vertical-align: sub">a</span></font><font face="Verdana" size="2">=λ/14 (λ=0.00055mm), needed focal ratio F=22.3. For these values of <b>D</b>, <b>ζ</b> and <b>F</b>, the coma RMS wavefront error is λ/40. Assuming the two mostly unrelated, the combined RMS wavefront error approximation, from the square root of the sum of errors squared, comes to ~λ/13.2. Still slightly below the 0.80 <a href="Strehl.htm">Strehl</a> standard (λ/13.4) in the field center, but it does exceed this level in the best portion of the field (<b>FIG. 133</b>). Since the tilt angle </font><b> <font face="Georgia" size="2">τ</font></b><font face="Verdana" size="2">=1.2°, at 0.2° off-center in the direction of mirror tilt, the actual incoming pencil angle is 1°, reducing the astigmatism wavefront error by a factor of 0.7 and coma by a factor 0.83, for the combined error of ~λ/18.5 wave RMS, and corresponding 0.89 Strehl.</font><div style="background-color: #FFFFFF; padding-left:3px; padding-right:3px"> <p align="center" style="text-indent: 0"> <font face="Arial" size="2"><b> <img border="0" src="images/hersch.png" width="300" height="263" align="left" vspace="4">FIGURE 133</b>: Ray spot diagram for a 100mm f/22.3 Herschelian with the mirror tilt </font><font face="Georgia" size="2">τ</font><font face="Arial" size="2">=0.021 radians (1.2°). The circle represents the Airy disc diameter. The field is aberrated asymmetrically, due to the wavefronts coming at the mirror from the direction of the tilt finding it inclined at a smaller angle than wavefronts coming from the radially opposite direction. The aberration diminishes going from the field center in the direction of mirror tilt (which is toward the location of the flat mirror ). The size of aberration is fairly sensitive to changes in the mirror F-number. Neglecting the change in <b>ζ</b> as relatively insignificant compared to change in the ratio number F, from <b>Eq.93</b>, to a first approximation the wavefront error for both, coma and astigmatism changes in inverse proportion to the cube of F- number. Thus, 10% slower mirror would have the aberrations lower by a factor of ~0.7. On the other hand, relatively small 10% gain in shortening the focal length would come at the price of both aberrations increased by about a third. As with all tilted-mirror systems, the image field is also tilted, although with the effect being negligible due to usually very low tilt angles. The field center aberrations are comparable to the effect of 33% central obstruction.</font></div> <p align="justify" style="line-height: 150%"> <font size="2" face="Verdana">The wavefront error of a tilted concave mirror can also be expressed in terms of the mirror tilt </font><b> <font face="Verdana">τ</font></b><font face="Verdana"> in degrees. For the aperture <b>D</b> in mm, the astigmatism RMS wavefront error in units of 550nm wavelength is given by w</font><font size="1" face="Terminal"><span style="vertical-align: sub">a</span></font><font face="Verdana">~D</font><b><font size="2" face="Verdana">τ</font></b><font face="Verdana" size="1"><span style="vertical-align: super; ">2</span></font><font face="Verdana">/71.4F, and that for the coma by w</font><font size="1" face="Terminal"><span style="vertical-align: sub">c</span></font><font face="Verdana">~D</font><b><font face="Verdana">τ</font></b><font face="Verdana">/8.6F</font><font face="Verdana" size="1"><span style="vertical-align: super; ">2</span></font><font face="Verdana">. For <b>D</b> in inches, w</font><font size="1" face="Terminal"><span style="vertical-align: sub">a</span></font><font face="Verdana">~D</font><b><font size="2" face="Verdana">τ</font></b><font face="Verdana" size="1"><span style="vertical-align: super; ">2</span></font><font face="Verdana">/2.8F, and w</font><font size="1" face="Terminal"><span style="vertical-align: sub">c</span></font><font face="Verdana">~3D</font><b><font face="Verdana">τ</font></b><font face="Verdana">/F</font><font face="Verdana" size="1"><span style="vertical-align: super; ">2</span></font><font face="Verdana"> (expressions are slightly rounded, but accurate to within a couple of percent).</font><p align="justify" style="line-height: 150%"> Herschelian<font face="Verdana">-type telescope can gain significantly in correction level, compactness, aperture size and/or relative aperture if some type of lens corrector is used to minimize tilt-induced aberrations. The usual choice is wedged lens, or wedged meniscus, inserted at an angle to the axis in the optical path in the converging light cone. A single BK7 meniscus with unequal radii (R</font><font size="1" face="Terminal"><span style="vertical-align: sub">1</span></font><font face="Verdana">=80mm, R</font><font size="1" face="Terminal"><span style="vertical-align: sub">2</span></font><font face="Verdana">=88.4mm, concave toward mirror, 9.8mm center thickness, front surface at 1450mm from mirror vertex, 3.8mm positive vertical axial decenter), reduces center-field aberration of a 2.3° tilted 200mm diameter </font>f<font face="Verdana">/8 sphere to 0.042 wave RMS. Despite some lateral color, it makes for quite useable unobstructed aperture, with better part of its strong field astigmatism offset by astigmatism of the eyepiece. Better results are possible with more sophisticated - and complex - corrective lenses.</font><p align="justify" style="line-height: 150%"> The question is, is there a prac<font face="Verdana">tical benefit from it? What is common to all these compensating lens correctors is that they have very tight tolerances for spacing, tilt angle, surface curvature and center thickness, due to an enormous load of compensatory aberrations (mainly astigmatism). It requires very accurate mounting and adjustment mechanism, and even then it is questionable how close to its optimum such a system can be objectively maintained. </font> <p align="justify" style="line-height: 150%"> On the other hand, a<font face="Verdana"> 200mm </font>f<font face="Verdana">/8 mirror in a regular Newtonian arrangement can work with central obstruction in the 0.15 to 0.25 of the aperture diameter range, satisfying requirements from high-contrast planetary to a wider illuminated field deep-sky instrument. Its particular advantage is comparatively low sensitivity to misalignment, thus likely better field performance than what optical data per se indicates. Considering this, a tilted-mirror telescope is an alternative mainly for those who find in it values other than its optical quality and practicality of use.</font></font><p align="center" style="text-indent:0"> <font face="Trebuchet MS" color="#336699">Catadioptric Herschelian with full aperture Houghton corrector</font><font size="2"><p align="justify" style="line-height: 150%"> <font face="Verdana" size="2"> A catadioptric variant of Herschelian that offers good overall correction, while making possible to use significantly faster mirror, uses the simplest form of a zero-power Houghton corrector: two full aperture plano (PCX and PCV) lenses of equal radii placed at nearly the focal length separation in front of the mirror. This is a slightly modified design originally proposed by D. Shafer (Telescope Making 41, as presented in "<i>Reflective and catadioptric objectives</i>" chapter by Lloyd Jones, University of Arizona). It is an all-spherical 150mm </font> <font face="Tahoma" size="2">f</font><font face="Verdana" size="2">/8 system.</font><p align="center" style="line-height: 150%; text-indent: 0"> <img border="0" src="images/catadioptric_Herschelian.PNG" width="722" height="555"><p align="justify" style="line-height: 150%; text-indent: 22px"> The two tilted elements are the rear lens and the mirror. Correction of aberrations is very good over flat field, with the diffraction field diameter exceeding 1 degree. Axial chromatism easily passes the "true apo" requirement; Lateral color is well controlled, with all the wavelengths remaining within the Airy disc. Image tilt (about 5.5° with left side being lower than the right side on the system diagram shown), results in 3.6 waves of defocus at 0.5° field angle. Linearly, it is nearly 1mm away from the plane containing field center. Since that field height (10-11 mm) corresponds to the field edge in a standard 20mm Plossl, the accommodation required is nearly 2.5 diopters (from one diopter of accommodation given by f<sup>2</sup>/1000, <b>f</b> being the eyepiece focal length), or from infinity to 0.4m. However, required field edge accommodation would double with 10mm f.l. eyepiece, which is still only a medium magnification range for the aperture. Note that the above system is not fully optimized, so nearly all aberrations can be a bit lower, but it wouldn't bring tangible practical gains. <p align="justify" style="line-height: 150%; text-indent: 22px"> For the system to approach its design correction level, the two tilted elements have to meet very tight tolerances, with respect to the tilt angle. Also all three elements (the diagonal flat is optional, and optically passive) have to be very well centered around optical axis. In other words, this system requires a high quality mechanical assembly - optical tube in general, and lens and mirror cells in particular.<p align="center"> <font face="Verdana" size="2"> <br> </font><span style="font-weight: 400"> <font size="2" face="Arial" color="#336699">◄</font></span><font face="Verdana" size="2"> <a href="paul-baker_telescope.htm">8.3.1. Paul-Baker, flat-field anastigmatic aplanats</a> </font><font size="2" face="Arial"><font color="#C0C0C0"> ▐</font> </font><font face="Verdana" size="2"> <a href="tilted_component_telescopes.htm">8.4.2. Two-mirror TCT</a> </font> <font face="Arial" size="2" color="#336699">►</font><p align="center" style="text-indent: 0"> <a href="index.htm">Home</a> | <a href="mailto:webpub@fastmail.com">Comments</a><p> </font></td> </tr> </table> </div> </body> </html>