CINXE.COM
Search results for: electromagnetic compatibility measurement
<!DOCTYPE html> <html lang="en" dir="ltr"> <head> <!-- Google tag (gtag.js) --> <script async src="https://www.googletagmanager.com/gtag/js?id=G-P63WKM1TM1"></script> <script> window.dataLayer = window.dataLayer || []; function gtag(){dataLayer.push(arguments);} gtag('js', new Date()); gtag('config', 'G-P63WKM1TM1'); </script> <!-- Yandex.Metrika counter --> <script type="text/javascript" > (function(m,e,t,r,i,k,a){m[i]=m[i]||function(){(m[i].a=m[i].a||[]).push(arguments)}; m[i].l=1*new Date(); for (var j = 0; j < document.scripts.length; j++) {if (document.scripts[j].src === r) { return; }} k=e.createElement(t),a=e.getElementsByTagName(t)[0],k.async=1,k.src=r,a.parentNode.insertBefore(k,a)}) (window, document, "script", "https://mc.yandex.ru/metrika/tag.js", "ym"); ym(55165297, "init", { clickmap:false, trackLinks:true, accurateTrackBounce:true, webvisor:false }); </script> <noscript><div><img src="https://mc.yandex.ru/watch/55165297" style="position:absolute; left:-9999px;" alt="" /></div></noscript> <!-- /Yandex.Metrika counter --> <!-- Matomo --> <!-- End Matomo Code --> <title>Search results for: electromagnetic compatibility measurement</title> <meta name="description" content="Search results for: electromagnetic compatibility measurement"> <meta name="keywords" content="electromagnetic compatibility measurement"> <meta name="viewport" content="width=device-width, initial-scale=1, minimum-scale=1, maximum-scale=1, user-scalable=no"> <meta charset="utf-8"> <link href="https://cdn.waset.org/favicon.ico" type="image/x-icon" rel="shortcut icon"> <link href="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/css/bootstrap.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/plugins/fontawesome/css/all.min.css" rel="stylesheet"> <link href="https://cdn.waset.org/static/css/site.css?v=150220211555" rel="stylesheet"> </head> <body> <header> <div class="container"> <nav class="navbar navbar-expand-lg navbar-light"> <a class="navbar-brand" href="https://waset.org"> <img src="https://cdn.waset.org/static/images/wasetc.png" alt="Open Science Research Excellence" title="Open Science Research Excellence" /> </a> <button class="d-block d-lg-none navbar-toggler ml-auto" type="button" data-toggle="collapse" data-target="#navbarMenu" aria-controls="navbarMenu" aria-expanded="false" aria-label="Toggle navigation"> <span class="navbar-toggler-icon"></span> </button> <div class="w-100"> <div class="d-none d-lg-flex flex-row-reverse"> <form method="get" action="https://waset.org/search" class="form-inline my-2 my-lg-0"> <input class="form-control mr-sm-2" type="search" placeholder="Search Conferences" value="electromagnetic compatibility measurement" name="q" aria-label="Search"> <button class="btn btn-light my-2 my-sm-0" type="submit"><i class="fas fa-search"></i></button> </form> </div> <div class="collapse navbar-collapse mt-1" id="navbarMenu"> <ul class="navbar-nav ml-auto align-items-center" id="mainNavMenu"> <li class="nav-item"> <a class="nav-link" href="https://waset.org/conferences" title="Conferences in 2024/2025/2026">Conferences</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/disciplines" title="Disciplines">Disciplines</a> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/committees" rel="nofollow">Committees</a> </li> <li class="nav-item dropdown"> <a class="nav-link dropdown-toggle" href="#" id="navbarDropdownPublications" role="button" data-toggle="dropdown" aria-haspopup="true" aria-expanded="false"> Publications </a> <div class="dropdown-menu" aria-labelledby="navbarDropdownPublications"> <a class="dropdown-item" href="https://publications.waset.org/abstracts">Abstracts</a> <a class="dropdown-item" href="https://publications.waset.org">Periodicals</a> <a class="dropdown-item" href="https://publications.waset.org/archive">Archive</a> </div> </li> <li class="nav-item"> <a class="nav-link" href="https://waset.org/page/support" title="Support">Support</a> </li> </ul> </div> </div> </nav> </div> </header> <main> <div class="container mt-4"> <div class="row"> <div class="col-md-9 mx-auto"> <form method="get" action="https://publications.waset.org/abstracts/search"> <div id="custom-search-input"> <div class="input-group"> <i class="fas fa-search"></i> <input type="text" class="search-query" name="q" placeholder="Author, Title, Abstract, Keywords" value="electromagnetic compatibility measurement"> <input type="submit" class="btn_search" value="Search"> </div> </div> </form> </div> </div> <div class="row mt-3"> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Commenced</strong> in January 2007</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Frequency:</strong> Monthly</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Edition:</strong> International</div> </div> </div> <div class="col-sm-3"> <div class="card"> <div class="card-body"><strong>Paper Count:</strong> 3443</div> </div> </div> </div> <h1 class="mt-3 mb-3 text-center" style="font-size:1.6rem;">Search results for: electromagnetic compatibility measurement</h1> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3443</span> EMI Radiation Prediction and Final Measurement Process Optimization by Neural Network</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hussam%20Elias">Hussam Elias</a>, <a href="https://publications.waset.org/abstracts/search?q=Ninovic%20Perez"> Ninovic Perez</a>, <a href="https://publications.waset.org/abstracts/search?q=Holger%20Hirsch"> Holger Hirsch</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The completion of the EMC regulations worldwide is growing steadily as the usage of electronics in our daily lives is increasing more than ever. In this paper, we introduce a novel method to perform the final phase of Electromagnetic compatibility (EMC) measurement and to reduce the required test time according to the norm EN 55032 by using a developed tool and the conventional neural network(CNN). The neural network was trained using real EMC measurements, which were performed in the Semi Anechoic Chamber (SAC) by CETECOM GmbH in Essen, Germany. To implement our proposed method, we wrote software to perform the radiated electromagnetic interference (EMI) measurements and use the CNN to predict and determine the position of the turntable that meets the maximum radiation value. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=conventional%20neural%20network" title="conventional neural network">conventional neural network</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement" title=" electromagnetic compatibility measurement"> electromagnetic compatibility measurement</a>, <a href="https://publications.waset.org/abstracts/search?q=mean%20absolute%20error" title=" mean absolute error"> mean absolute error</a>, <a href="https://publications.waset.org/abstracts/search?q=position%20error" title=" position error"> position error</a> </p> <a href="https://publications.waset.org/abstracts/143266/emi-radiation-prediction-and-final-measurement-process-optimization-by-neural-network" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/143266.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">200</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3442</span> A Fast Algorithm for Electromagnetic Compatibility Estimation for Radio Communication Network Equipment in a Complex Electromagnetic Environment</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=C.%20Temaneh-Nyah">C. Temaneh-Nyah </a> </p> <p class="card-text"><strong>Abstract:</strong></p> Electromagnetic compatibility (EMC) is the ability of a Radio Communication Equipment (RCE) to operate with a desired quality of service in a given Electromagnetic Environment (EME) and not to create harmful interference with other RCE. This paper presents an algorithm which improves the simulation speed of estimating EMC of RCE in a complex EME, based on a stage by stage frequency-energy criterion of filtering. This algorithm considers different interference types including: Blocking and intermodulation. It consist of the following steps: simplified energy criterion where filtration is based on comparing the free space interference level to the industrial noise, frequency criterion which checks whether the interfering emissions characteristic overlap with the receiver’s channels characteristic and lastly the detailed energy criterion where the real channel interference level is compared to the noise level. In each of these stages, some interference cases are filtered out by the relevant criteria. This reduces the total number of dual and different combinations of RCE involved in the tedious detailed energy analysis and thus provides an improved simulation speed. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility" title="electromagnetic compatibility">electromagnetic compatibility</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20environment" title=" electromagnetic environment"> electromagnetic environment</a>, <a href="https://publications.waset.org/abstracts/search?q=simulation%20of%20communication%20network" title=" simulation of communication network"> simulation of communication network</a> </p> <a href="https://publications.waset.org/abstracts/1966/a-fast-algorithm-for-electromagnetic-compatibility-estimation-for-radio-communication-network-equipment-in-a-complex-electromagnetic-environment" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/1966.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">218</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3441</span> Noise Mitigation Techniques to Minimize Electromagnetic Interference/Electrostatic Discharge Effects for the Lunar Mission Spacecraft</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Vabya%20Kumar%20Pandit">Vabya Kumar Pandit</a>, <a href="https://publications.waset.org/abstracts/search?q=Mudit%20Mittal"> Mudit Mittal</a>, <a href="https://publications.waset.org/abstracts/search?q=N.%20Prahlad%20Rao"> N. Prahlad Rao</a>, <a href="https://publications.waset.org/abstracts/search?q=Ramnath%20Babu"> Ramnath Babu</a> </p> <p class="card-text"><strong>Abstract:</strong></p> TeamIndus is the only Indian team competing for the Google Lunar XPRIZE(GLXP). The GLXP is a global competition to challenge the private entities to soft land a rover on the moon, travel minimum 500 meters and transmit high definition images and videos to Earth. Towards this goal, the TeamIndus strategy is to design and developed lunar lander that will deliver a rover onto the surface of the moon which will accomplish GLXP mission objectives. This paper showcases the various system level noise control techniques adopted by Electrical Distribution System (EDS), to achieve the required Electromagnetic Compatibility (EMC) of the spacecraft. The design guidelines followed to control Electromagnetic Interference by proper electronic package design, grounding, shielding, filtering, and cable routing within the stipulated mass budget, are explained. The paper also deals with the challenges of achieving Electromagnetic Cleanliness in presence of various Commercial Off-The-Shelf (COTS) and In-House developed components. The methods of minimizing Electrostatic Discharge (ESD) by identifying the potential noise sources, susceptible areas for charge accumulation and the methodology to prevent arcing inside spacecraft are explained. The paper then provides the EMC requirements matrix derived from the mission requirements to meet the overall Electromagnetic compatibility of the Spacecraft. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility" title="electromagnetic compatibility">electromagnetic compatibility</a>, <a href="https://publications.waset.org/abstracts/search?q=electrostatic%20discharge" title=" electrostatic discharge"> electrostatic discharge</a>, <a href="https://publications.waset.org/abstracts/search?q=electrical%20distribution%20systems" title=" electrical distribution systems"> electrical distribution systems</a>, <a href="https://publications.waset.org/abstracts/search?q=grounding%20schemes" title=" grounding schemes"> grounding schemes</a>, <a href="https://publications.waset.org/abstracts/search?q=light%20weight%20harnessing" title=" light weight harnessing"> light weight harnessing</a> </p> <a href="https://publications.waset.org/abstracts/71198/noise-mitigation-techniques-to-minimize-electromagnetic-interferenceelectrostatic-discharge-effects-for-the-lunar-mission-spacecraft" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/71198.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">293</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3440</span> Mitigation of Electromagnetic Interference Generated by GPIB Control-Network in AC-DC Transfer Measurement System</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=M.%20M.%20Hlakola">M. M. Hlakola</a>, <a href="https://publications.waset.org/abstracts/search?q=E.%20Golovins"> E. Golovins</a>, <a href="https://publications.waset.org/abstracts/search?q=D.%20V.%20Nicolae"> D. V. Nicolae</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The field of instrumentation electronics is undergoing an explosive growth, due to its wide range of applications. The proliferation of electrical devices in a close working proximity can negatively influence each other’s performance. The degradation in the performance is due to electromagnetic interference (EMI). This paper investigates the negative effects of electromagnetic interference originating in the General Purpose Interface Bus (GPIB) control-network of the ac-dc transfer measurement system. Remedial measures of reducing measurement errors and failure of range of industrial devices due to EMI have been explored. The ac-dc transfer measurement system was analyzed for the common-mode (CM) EMI effects. Further investigation of coupling path as well as more accurate identification of noise propagation mechanism has been outlined. To prevent the occurrence of common-mode (ground loops) which was identified between the GPIB system control circuit and the measurement circuit, a microcontroller-driven GPIB switching isolator device was designed, prototyped, programmed and validated. This mitigation technique has been explored to reduce EMI effectively. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=CM" title="CM">CM</a>, <a href="https://publications.waset.org/abstracts/search?q=EMI" title=" EMI"> EMI</a>, <a href="https://publications.waset.org/abstracts/search?q=GPIB" title=" GPIB"> GPIB</a>, <a href="https://publications.waset.org/abstracts/search?q=ground%20loops" title=" ground loops"> ground loops</a> </p> <a href="https://publications.waset.org/abstracts/40477/mitigation-of-electromagnetic-interference-generated-by-gpib-control-network-in-ac-dc-transfer-measurement-system" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/40477.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">288</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3439</span> Filter for the Measurement of Supraharmonics in Distribution Networks</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sivaraman%20Karthikeyan">Sivaraman Karthikeyan</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Due to rapidly developing power electronics devices and technologies such as power line communication or self-commutating converters, voltage and current distortion, as well as interferences, have increased in the frequency range of 2 kHz to 150 kHz; there is an urgent need for regulation of electromagnetic compatibility (EMC) standards in this frequency range. Measuring or testing compliance with emission and immunity limitations necessitates the use of precise, repeatable measuring methods. Appropriate filters to minimize the fundamental component and its harmonics below 2 kHz in the measuring signal would improve the measurement accuracy in this frequency range leading to better analysis. This paper discusses filter suggestions in the current measurement standard and proposes an infinite impulse response (IIR) filter design that is optimized for a low number of poles, strong fundamental damping, and high accuracy above 2 kHz. The new filter’s transfer function is delivered as a result. An analog implementation is derived from the overall design. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=supraharmonics" title="supraharmonics">supraharmonics</a>, <a href="https://publications.waset.org/abstracts/search?q=2%20kHz" title=" 2 kHz"> 2 kHz</a>, <a href="https://publications.waset.org/abstracts/search?q=150%20kHz" title=" 150 kHz"> 150 kHz</a>, <a href="https://publications.waset.org/abstracts/search?q=filter" title=" filter"> filter</a>, <a href="https://publications.waset.org/abstracts/search?q=analog%20filter" title=" analog filter"> analog filter</a> </p> <a href="https://publications.waset.org/abstracts/157610/filter-for-the-measurement-of-supraharmonics-in-distribution-networks" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/157610.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">146</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3438</span> Mathematical Modeling of the Operating Process and a Method to Determine the Design Parameters in an Electromagnetic Hammer Using Solenoid Electromagnets</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Song%20Hyok%20Choe">Song Hyok Choe</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study presented a method to determine the optimum design parameters based on a mathematical model of the operating process in a manual electromagnetic hammer using solenoid electromagnets. The operating process of the electromagnetic hammer depends on the circuit scheme of the power controller. Mathematical modeling of the operating process was carried out by considering the energy transfer process in the forward and reverse windings and the electromagnetic force acting on the impact and brake pistons. Using the developed mathematical model, the initial design data of a manual electromagnetic hammer proposed in this paper are encoded and analyzed in Matlab. On the other hand, a measuring experiment was carried out by using a measurement device to check the accuracy of the developed mathematical model. The relative errors of the analytical results for measured stroke distance of the impact piston, peak value of forward stroke current and peak value of reverse stroke current were −4.65%, 9.08% and 9.35%, respectively. Finally, it was shown that the mathematical model of the operating process of an electromagnetic hammer is relatively accurate, and it can be used to determine the design parameters of the electromagnetic hammer. Therefore, the design parameters that can provide the required impact energy in the manual electromagnetic hammer were determined using a mathematical model developed. The proposed method will be used for the further design and development of the various types of percussion rock drills. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=solenoid%20electromagnet" title="solenoid electromagnet">solenoid electromagnet</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20hammer" title=" electromagnetic hammer"> electromagnetic hammer</a>, <a href="https://publications.waset.org/abstracts/search?q=stone%20processing" title=" stone processing"> stone processing</a>, <a href="https://publications.waset.org/abstracts/search?q=mathematical%20modeling" title=" mathematical modeling"> mathematical modeling</a> </p> <a href="https://publications.waset.org/abstracts/187061/mathematical-modeling-of-the-operating-process-and-a-method-to-determine-the-design-parameters-in-an-electromagnetic-hammer-using-solenoid-electromagnets" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/187061.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">46</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3437</span> Managing the Magnetic Protection of Workers in Magnetic Resonance Imaging</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Safoin%20Aktaou">Safoin Aktaou</a>, <a href="https://publications.waset.org/abstracts/search?q=Aya%20Al%20Masri"> Aya Al Masri</a>, <a href="https://publications.waset.org/abstracts/search?q=Kamel%20Guerchouche"> Kamel Guerchouche</a>, <a href="https://publications.waset.org/abstracts/search?q=Malorie%20Martin"> Malorie Martin</a>, <a href="https://publications.waset.org/abstracts/search?q=Fouad%20Maaloul"> Fouad Maaloul</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Introduction: In the ‘Magnetic Resonance Imaging (MRI)’ department, all workers involved in preparing the patient, setting it up, tunnel cleaning, etc. are likely to be exposed to ‘ElectroMagnetic fields (EMF)’ emitted by the MRI device. Exposure to EMF can cause adverse radio-biological effects to workers. The purpose of this study is to propose an organizational process to manage and control EMF risks. Materials and methods: The study was conducted at seven MRI departments using machines with 1.5 and 3 Tesla magnetic fields. We assessed the exposure of each one by measuring the two electromagnetic fields (static and dynamic) at different distances from the MRI machine both inside and around the examination room. Measurement values were compared with British and American references (those of the UK's ‘Medicines and Healthcare Regulatory Agency (MHRA)’ and the ‘American Radiology Society (ACR)’). Results: Following the results of EMF measurements and their comparison with the recommendations of learned societies, a zoning system that adapts to needs of different MRI services across the country has been proposed. In effect, three risk areas have been identified within the MRI services. This has led to the development of a good practice guide related to the magnetic protection of MRI workers. Conclusion: The guide established by our study is a standard that allows MRI workers to protect themselves against the risk of electromagnetic fields. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=comparison%20with%20international%20references" title="comparison with international references">comparison with international references</a>, <a href="https://publications.waset.org/abstracts/search?q=measurement%20of%20electromagnetic%20fields" title=" measurement of electromagnetic fields"> measurement of electromagnetic fields</a>, <a href="https://publications.waset.org/abstracts/search?q=magnetic%20protection%20of%20workers" title=" magnetic protection of workers"> magnetic protection of workers</a>, <a href="https://publications.waset.org/abstracts/search?q=magnetic%20resonance%20imaging" title=" magnetic resonance imaging"> magnetic resonance imaging</a> </p> <a href="https://publications.waset.org/abstracts/119063/managing-the-magnetic-protection-of-workers-in-magnetic-resonance-imaging" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/119063.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">164</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3436</span> Experimental and Theoretical Study of the Electric and Magnetic Fields Behavior in the Vicinity of High-Voltage Power Lines</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Tourab%20Wafa">Tourab Wafa</a>, <a href="https://publications.waset.org/abstracts/search?q=Nemamcha%20Mohamed"> Nemamcha Mohamed</a>, <a href="https://publications.waset.org/abstracts/search?q=Babouri%20Abdessalem"> Babouri Abdessalem</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper consists on an experimental and analytical characterization of the electromagnetic environment in the in the medium surrounding a circuit of two 220 Kv power lines running in parallel. The analysis presented in this paper is divided into two main parts. The first part concerns the experimental study of the behavior of the electric field and magnetic field generated by the selected double-circuit at ground level (0 m). While the second part simulate and calculate the fields profiles generated by the both lines at different levels above the ground, from (0 m) to the level close to the lines conductors (20 m above the ground) using the electrostatic and magneto-static modules of the COMSOL multi-physics software. The implications of the results are discussed and compared with the ICNIRP reference levels for occupational and non occupational exposures. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=HV%20power%20lines" title="HV power lines">HV power lines</a>, <a href="https://publications.waset.org/abstracts/search?q=low%20frequency%20electromagnetic%20fields" title=" low frequency electromagnetic fields"> low frequency electromagnetic fields</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility" title=" electromagnetic compatibility"> electromagnetic compatibility</a>, <a href="https://publications.waset.org/abstracts/search?q=inductive%20and%20capacitive%20coupling" title=" inductive and capacitive coupling"> inductive and capacitive coupling</a>, <a href="https://publications.waset.org/abstracts/search?q=standards" title=" standards"> standards</a> </p> <a href="https://publications.waset.org/abstracts/22336/experimental-and-theoretical-study-of-the-electric-and-magnetic-fields-behavior-in-the-vicinity-of-high-voltage-power-lines" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/22336.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">474</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3435</span> European Electromagnetic Compatibility Directive Applied to Astronomical Observatories</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Oibar%20Martinez">Oibar Martinez</a>, <a href="https://publications.waset.org/abstracts/search?q=Clara%20Oliver"> Clara Oliver</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The Cherenkov Telescope Array Project (CTA) aims to build two different observatories of Cherenkov Telescopes, located in Cerro del Paranal, Chile, and La Palma, Spain. These facilities are used in this paper as a case study to investigate how to apply standard Directives on Electromagnetic Compatibility to astronomical observatories. Cherenkov Telescopes are able to provide valuable information from both Galactic and Extragalactic sources by measuring Cherenkov radiation, which is produced by particles which travel faster than light in the atmosphere. The construction requirements demand compliance with the European Electromagnetic Compatibility Directive. The largest telescopes of these observatories, called Large Scale Telescopes (LSTs), are high precision instruments with advanced photomultipliers able to detect the faint sub-nanosecond blue light pulses produced by Cherenkov Radiation. They have a 23-meter parabolic reflective surface. This surface focuses the radiation on a camera composed of an array of high-speed photosensors which are highly sensitive to the radio spectrum pollution. The camera has a field of view of about 4.5 degrees and has been designed for maximum compactness and lowest weight, cost and power consumption. Each pixel incorporates a photo-sensor able to discriminate single photons and the corresponding readout electronics. The first LST is already commissioned and intends to be operated as a service to Scientific Community. Because of this, it must comply with a series of reliability and functional requirements and must have a Conformité Européen (CE) marking. This demands compliance with Directive 2014/30/EU on electromagnetic compatibility. The main difficulty of accomplishing this goal resides on the fact that Conformité Européen marking setups and procedures were implemented for industrial products, whereas no clear protocols have been defined for scientific installations. In this paper, we aim to give an answer to the question on how the directive should be applied to our installation to guarantee the fulfillment of all the requirements and the proper functioning of the telescope itself. Experts in Optics and Electromagnetism were both needed to make these kinds of decisions and match tests which were designed to be made over the equipment of limited dimensions on large scientific plants. An analysis of the elements and configurations most likely to be affected by external interferences and those that are most likely to cause the maximum disturbances was also performed. Obtaining the Conformité Européen mark requires knowing what the harmonized standards are and how the elaboration of the specific requirement is defined. For this type of large installations, one needs to adapt and develop the tests to be carried out. In addition, throughout this process, certification entities and notified bodies play a key role in preparing and agreeing the required technical documentation. We have focused our attention mostly on the technical aspects of each point. We believe that this contribution will be of interest for other scientists involved in applying industrial quality assurance standards to large scientific plant. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=CE%20marking" title="CE marking">CE marking</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility" title=" electromagnetic compatibility"> electromagnetic compatibility</a>, <a href="https://publications.waset.org/abstracts/search?q=european%20directive" title=" european directive"> european directive</a>, <a href="https://publications.waset.org/abstracts/search?q=scientific%20installations" title=" scientific installations"> scientific installations</a> </p> <a href="https://publications.waset.org/abstracts/107653/european-electromagnetic-compatibility-directive-applied-to-astronomical-observatories" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/107653.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">110</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3434</span> Electromagnetic Interference Shielding Characteristics for Stainless Wire Mesh and Number of Plies of Carbon Fiber Reinforced Plastic</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Min%20Sang%20Lee">Min Sang Lee</a>, <a href="https://publications.waset.org/abstracts/search?q=Hee%20Jae%20Shin"> Hee Jae Shin</a>, <a href="https://publications.waset.org/abstracts/search?q=In%20Pyo%20Cha"> In Pyo Cha</a>, <a href="https://publications.waset.org/abstracts/search?q=Hyun%20Kyung%20Yoon"> Hyun Kyung Yoon</a>, <a href="https://publications.waset.org/abstracts/search?q=Seong%20Woo%20Hong"> Seong Woo Hong</a>, <a href="https://publications.waset.org/abstracts/search?q=Min%20Jae%20Yu"> Min Jae Yu</a>, <a href="https://publications.waset.org/abstracts/search?q=Hong%20Gun%20Kim"> Hong Gun Kim</a>, <a href="https://publications.waset.org/abstracts/search?q=Lee%20Ku%20Kwac"> Lee Ku Kwac</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, the electromagnetic shielding characteristics of an up-to-date typical carbon filler material, carbon fiber used with a metal mesh were investigated. Carbon fiber 12k-prepregs, where carbon fibers were impregnated with epoxy, were laminated with wire meshes, vacuum bag-molded and hardened to manufacture hybrid-type specimens, with which an electromagnetic shield test was performed in accordance with ASTM D4935-10, through which was known as the most excellent reproducibility is obtainable among electromagnetic shield tests. In addition, glass fiber prepress whose electromagnetic shielding effect were known as insignificant were laminated and formed with wire meshes to verify the validity of the electromagnetic shield effect of wire meshes in order to confirm the electromagnetic shielding effect of metal meshes corresponding existing carbon fiber 12k-prepregs. By grafting carbon fibers, on which studies are being actively underway in the environmental aspects and electromagnetic shielding effect, with hybrid-type wire meshes that were analyzed through the tests, in this study, the applicability and possibility are proposed. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=Carbon%20Fiber%20Reinforced%20Plastic%28CFRP%29" title="Carbon Fiber Reinforced Plastic(CFRP)">Carbon Fiber Reinforced Plastic(CFRP)</a>, <a href="https://publications.waset.org/abstracts/search?q=Glass%20Fiber%20Reinforced%20Plastic%28GFRP%29" title=" Glass Fiber Reinforced Plastic(GFRP)"> Glass Fiber Reinforced Plastic(GFRP)</a>, <a href="https://publications.waset.org/abstracts/search?q=stainless%20wire%20mesh" title=" stainless wire mesh"> stainless wire mesh</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20shielding" title=" electromagnetic shielding"> electromagnetic shielding</a> </p> <a href="https://publications.waset.org/abstracts/20071/electromagnetic-interference-shielding-characteristics-for-stainless-wire-mesh-and-number-of-plies-of-carbon-fiber-reinforced-plastic" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/20071.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">415</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3433</span> Electromagnetic Radiation Absorbers on the Basis of Fibrous Materials with the Content of Allotropic Carbon Forms</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Elena%20S.%20%20Belousova">Elena S. Belousova</a>, <a href="https://publications.waset.org/abstracts/search?q=Olga%20V.%20Boiprav"> Olga V. Boiprav</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A technique for incorporating particles of allotropic forms of carbon into a fibrous material has been developed. It can be used for the manufacture of composite electromagnetic radiation absorbers. The frequency characteristics of electromagnetic radiation reflection and transmission coefficients in the microwave range of absorbers on the basis of powdered carbon black, activated carbon, shungite, graphite, manufactured in accordance with the developed technique, have been studied. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=carbon" title="carbon">carbon</a>, <a href="https://publications.waset.org/abstracts/search?q=graphite" title=" graphite"> graphite</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20radiation%20absorber" title=" electromagnetic radiation absorber"> electromagnetic radiation absorber</a>, <a href="https://publications.waset.org/abstracts/search?q=shungite" title=" shungite"> shungite</a> </p> <a href="https://publications.waset.org/abstracts/121253/electromagnetic-radiation-absorbers-on-the-basis-of-fibrous-materials-with-the-content-of-allotropic-carbon-forms" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/121253.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">163</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3432</span> Effect of Electromagnetic Field on Capacitive Deionization Performance</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Alibi%20Kilybay">Alibi Kilybay</a>, <a href="https://publications.waset.org/abstracts/search?q=Emad%20Alhseinat"> Emad Alhseinat</a>, <a href="https://publications.waset.org/abstracts/search?q=Ibrahim%20Mustafa"> Ibrahim Mustafa</a>, <a href="https://publications.waset.org/abstracts/search?q=Abdulfahim%20Arangadi"> Abdulfahim Arangadi</a>, <a href="https://publications.waset.org/abstracts/search?q=Pei%20Shui"> Pei Shui</a>, <a href="https://publications.waset.org/abstracts/search?q=Faisal%20Almarzooqi"> Faisal Almarzooqi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this work, the electromagnetic field has been used for improving the performance of the capacitive deionization process. The effect of electromagnetic fields on the efficiency of the capacitive deionization (CDI) process was investigated experimentally. The results showed that treating the feed stream of the CDI process using an electromagnetic field can enhance the electrosorption capacity from 20% up to 70%. The effect of the degree of time of exposure, concentration, and type of ions have been examined. The electromagnetic field enhanced the salt adsorption capacity (SAC) of the Ca²⁺ ions by 70%, while the SAC enhanced 20% to the Na⁺ ions. It is hypnotized that the electrometric field affects the hydration shell around the ions and thus reduces their effective size and enhances the mass transfer. This reduction in ion effective size and increase in mass transfer enhanced the electrosorption capacity and kinetics of the CDI process. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=capacitive%20deionization" title="capacitive deionization">capacitive deionization</a>, <a href="https://publications.waset.org/abstracts/search?q=desalination" title=" desalination"> desalination</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20treatment" title=" electromagnetic treatment"> electromagnetic treatment</a>, <a href="https://publications.waset.org/abstracts/search?q=water%20treatment" title=" water treatment"> water treatment</a> </p> <a href="https://publications.waset.org/abstracts/134804/effect-of-electromagnetic-field-on-capacitive-deionization-performance" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/134804.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">264</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3431</span> Electromagnetic Simulation of Underground Cable Perforation by Nail </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20Nour%20El%20Islam%20Ayad">Ahmed Nour El Islam Ayad</a>, <a href="https://publications.waset.org/abstracts/search?q=Tahar%20Rouibah"> Tahar Rouibah</a>, <a href="https://publications.waset.org/abstracts/search?q=Wafa%20Krika"> Wafa Krika</a>, <a href="https://publications.waset.org/abstracts/search?q=Houari%20Boudjella"> Houari Boudjella</a>, <a href="https://publications.waset.org/abstracts/search?q=Larab%20Moulay"> Larab Moulay</a>, <a href="https://publications.waset.org/abstracts/search?q=Farid%20Benhamida"> Farid Benhamida</a>, <a href="https://publications.waset.org/abstracts/search?q=Selma%20Benmoussa"> Selma Benmoussa</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The purpose of this study is to evaluate the electromagnetic field of an underground cable of very high voltage perforated by nail. The aim of this work shows a numerical simulation of the electromagnetic field of 400 kV line after perforation through a ferrous nail in four positions for the pinch pin at different distances. From results for a longitudinal section, we observe and evaluate the distribution and the variation of the electromagnetic field in the cable and the earth. When the nail approaches the underground power cable, the distribution of the magnetic field changes and takes several forms, the magnetic field increase and become very important when the nail breaks the metal screen and will produce a significant leak of the electric field, characterized by a large electric arc and or electric discharge to earth and then a fault in the electrical network. These electromagnetic analysis results help to detect defects in underground cables. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=underground" title="underground">underground</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic" title=" electromagnetic"> electromagnetic</a>, <a href="https://publications.waset.org/abstracts/search?q=nail" title=" nail"> nail</a>, <a href="https://publications.waset.org/abstracts/search?q=defect" title=" defect"> defect</a> </p> <a href="https://publications.waset.org/abstracts/114023/electromagnetic-simulation-of-underground-cable-perforation-by-nail" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/114023.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">231</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3430</span> Compact Optical Sensors for Harsh Environments</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Branislav%20Timotijevic">Branislav Timotijevic</a>, <a href="https://publications.waset.org/abstracts/search?q=Yves%20Petremand"> Yves Petremand</a>, <a href="https://publications.waset.org/abstracts/search?q=Markus%20Luetzelschwab"> Markus Luetzelschwab</a>, <a href="https://publications.waset.org/abstracts/search?q=Dara%20Bayat"> Dara Bayat</a>, <a href="https://publications.waset.org/abstracts/search?q=Laurent%20Aebi"> Laurent Aebi</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Optical miniaturized sensors with remote readout are required devices for the monitoring in harsh electromagnetic environments. As an example, in turbo and hydro generators, excessively high vibrations of the end-windings can lead to dramatic damages, imposing very high, additional service costs. A significant change of the generator temperature can also be an indicator of the system failure. Continuous monitoring of vibrations, temperature, humidity, and gases is therefore mandatory. The high electromagnetic fields in the generators impose the use of non-conductive devices in order to prevent electromagnetic interferences and to electrically isolate the sensing element to the electronic readout. Metal-free sensors are good candidates for such systems since they are immune to very strong electromagnetic fields and given the fact that they are non-conductive. We have realized miniature optical accelerometer and temperature sensors for a remote sensing of the harsh environments using the common, inexpensive silicon Micro Electro-Mechanical System (MEMS) platform. Both devices show highly linear response. The accelerometer has a deviation within 1% from the linear fit when tested in a range 0 – 40 g. The temperature sensor can provide the measurement accuracy better than 1 °C in a range 20 – 150 °C. The design of other type of sensors for the environments with high electromagnetic interferences has also been discussed. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=optical%20MEMS" title="optical MEMS">optical MEMS</a>, <a href="https://publications.waset.org/abstracts/search?q=temperature%20sensor" title=" temperature sensor"> temperature sensor</a>, <a href="https://publications.waset.org/abstracts/search?q=accelerometer" title=" accelerometer"> accelerometer</a>, <a href="https://publications.waset.org/abstracts/search?q=remote%20sensing" title=" remote sensing"> remote sensing</a>, <a href="https://publications.waset.org/abstracts/search?q=harsh%20environment" title=" harsh environment"> harsh environment</a> </p> <a href="https://publications.waset.org/abstracts/65332/compact-optical-sensors-for-harsh-environments" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/65332.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">367</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3429</span> Permanent Magnet Synchronous Generator: Unsymmetrical Point Operation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=P.%20Pistelok">P. Pistelok</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The article presents the concept of an electromagnetic circuit generator with permanent magnets mounted on the surface rotor core designed for single phase work. Computation field-circuit model was shown. The spectrum of time course of voltages in the idle work was presented. The cross section with graphically presentation of magnetic induction in particular parts of electromagnetic circuits was presented. Distribution of magnetic induction at the rated load point for each phase were shown. The time course of voltages and currents for each phases for rated power were displayed. An analysis of laboratory results and measurement of load characteristics of the generator was discussed. The work deals with three electromagnetic circuits of generators with permanent magnet where output voltage characteristics versus rated power were expressed. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=permanent%20magnet%20generator" title="permanent magnet generator">permanent magnet generator</a>, <a href="https://publications.waset.org/abstracts/search?q=permanent%20magnets" title=" permanent magnets"> permanent magnets</a>, <a href="https://publications.waset.org/abstracts/search?q=vibration" title=" vibration"> vibration</a>, <a href="https://publications.waset.org/abstracts/search?q=course%20of%20torque" title=" course of torque"> course of torque</a>, <a href="https://publications.waset.org/abstracts/search?q=single%20phase%20work" title=" single phase work"> single phase work</a>, <a href="https://publications.waset.org/abstracts/search?q=asymmetrical%20three%20phase%20work" title=" asymmetrical three phase work"> asymmetrical three phase work</a> </p> <a href="https://publications.waset.org/abstracts/13061/permanent-magnet-synchronous-generator-unsymmetrical-point-operation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/13061.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">288</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3428</span> Enhancement Effect of Electromagnetic Field on Separation of Edible Oil from Oil-Water Emulsion</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Olfat%20A.%20Fadali">Olfat A. Fadali</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20S.%20Mahmoud"> Mohamed S. Mahmoud</a>, <a href="https://publications.waset.org/abstracts/search?q=Omnia%20H.%20Abdelraheem"> Omnia H. Abdelraheem</a>, <a href="https://publications.waset.org/abstracts/search?q=Shimaa%20G.%20Mohammed"> Shimaa G. Mohammed </a> </p> <p class="card-text"><strong>Abstract:</strong></p> The effect of electromagnetic field (EMF) on the removal of edible oil from oil-in-water emulsion by means of electrocoagulation was investigated in rectangular batch electrochemical cell with DC current. Iron (Fe) plate anodes and stainless steel cathodes were employed as electrodes. The effect of different magnetic field intensities (1.9, 3.9 and 5.2 tesla), three different positions of EMF (below, perpendicular and parallel to the electrocoagulation cell), as well as operating time; had been investigated. The application of electromagnetic field (5.2 tesla) raises percentage of oil removal from 72.4% for traditional electrocoagulation to 90.8% after 20 min. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electrocoagulation" title="electrocoagulation">electrocoagulation</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20field" title=" electromagnetic field"> electromagnetic field</a>, <a href="https://publications.waset.org/abstracts/search?q=Oil-water%20emulsion" title=" Oil-water emulsion"> Oil-water emulsion</a>, <a href="https://publications.waset.org/abstracts/search?q=edible%20oil" title=" edible oil"> edible oil</a> </p> <a href="https://publications.waset.org/abstracts/19283/enhancement-effect-of-electromagnetic-field-on-separation-of-edible-oil-from-oil-water-emulsion" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/19283.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">532</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3427</span> Characterization of Complex Electromagnetic Environment Created by Multiple Sources of Electromagnetic Radiation</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Clement%20Temaneh-Nyah">Clement Temaneh-Nyah</a>, <a href="https://publications.waset.org/abstracts/search?q=Josiah%20Makiche"> Josiah Makiche</a>, <a href="https://publications.waset.org/abstracts/search?q=Josephine%20Nujoma"> Josephine Nujoma</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper considers the characterisation of a complex electromagnetic environment due to multiple sources of electromagnetic radiation as a five-dimensional surface which can be described by a set of several surface sections including: instant EM field intensity distribution maps at a given frequency and altitude, instantaneous spectrum at a given location in space and the time evolution of the electromagnetic field spectrum at a given point in space. This characterization if done over time can enable the exposure levels of Radio Frequency Radiation at every point in the analysis area to be determined and results interpreted based on comparison of the determined RFR exposure level with the safe guidelines for general public exposure given by recognised body such as the International commission on non-ionising radiation protection (ICNIRP), Institute of Electrical and Electronic Engineers (IEEE), the National Radiation Protection Authority (NRPA). <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=complex%20electromagnetic%20environment" title="complex electromagnetic environment">complex electromagnetic environment</a>, <a href="https://publications.waset.org/abstracts/search?q=electric%20field%20strength" title=" electric field strength"> electric field strength</a>, <a href="https://publications.waset.org/abstracts/search?q=mathematical%20models" title=" mathematical models"> mathematical models</a>, <a href="https://publications.waset.org/abstracts/search?q=multiple%20sources" title=" multiple sources"> multiple sources</a> </p> <a href="https://publications.waset.org/abstracts/16672/characterization-of-complex-electromagnetic-environment-created-by-multiple-sources-of-electromagnetic-radiation" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/16672.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">368</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3426</span> Soil Salinity Mapping using Electromagnetic Induction Measurements</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Fethi%20Bouksila">Fethi Bouksila</a>, <a href="https://publications.waset.org/abstracts/search?q=Nessrine%20Zemni"> Nessrine Zemni</a>, <a href="https://publications.waset.org/abstracts/search?q=Fairouz%20Slama"> Fairouz Slama</a>, <a href="https://publications.waset.org/abstracts/search?q=Magnus%20Persson"> Magnus Persson</a>, <a href="https://publications.waset.org/abstracts/search?q=Ronny%20%20Berndasson"> Ronny Berndasson</a>, <a href="https://publications.waset.org/abstracts/search?q=Akissa%20Bahri"> Akissa Bahri</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Electromagnetic sensor EM 38 was used to predict and map soil salinity (ECe) in arid oasis. Despite the high spatial variation of soil moisture and shallow watertable, significant ECe-EM relationships were developed. The low drainage network efficiency is the main factor of soil salinization <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=soil%20salinity%20map" title="soil salinity map">soil salinity map</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20induction" title="electromagnetic induction">electromagnetic induction</a>, <a href="https://publications.waset.org/abstracts/search?q=EM38" title=" EM38"> EM38</a>, <a href="https://publications.waset.org/abstracts/search?q=oasis" title=" oasis"> oasis</a>, <a href="https://publications.waset.org/abstracts/search?q=shallow%20watertable" title=" shallow watertable"> shallow watertable</a> </p> <a href="https://publications.waset.org/abstracts/146153/soil-salinity-mapping-using-electromagnetic-induction-measurements" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/146153.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">187</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3425</span> Biosphere Compatibility and Sustainable Development</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Zinaida%20I.%20Ivanova">Zinaida I. Ivanova</a>, <a href="https://publications.waset.org/abstracts/search?q=Olga%20V.%20Yudenkova"> Olga V. Yudenkova</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The article addresses the pressing need to implement the principle of the biosphere compatibility as the core prerequisite for sustainable development. The co-authors argue that a careful attitude towards the biosphere, termination of its overutilization, analysis of the ratio between the biospheric potential of a specific area and its population numbers, coupled with population regulation techniques represent the factors that may solve the problems of ecological depletion. However these problems may only be tackled through the employment of the high-quality human capital, capable of acting with account for the principles of nature conservation. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=biosphere%20compatibility" title="biosphere compatibility">biosphere compatibility</a>, <a href="https://publications.waset.org/abstracts/search?q=eco-centered%20conscience" title=" eco-centered conscience"> eco-centered conscience</a>, <a href="https://publications.waset.org/abstracts/search?q=human%20capital" title=" human capital"> human capital</a>, <a href="https://publications.waset.org/abstracts/search?q=sustainable%20development" title=" sustainable development"> sustainable development</a> </p> <a href="https://publications.waset.org/abstracts/9563/biosphere-compatibility-and-sustainable-development" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/9563.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">389</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3424</span> Accurate Position Electromagnetic Sensor Using Data Acquisition System</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Z.%20Ezzouine">Z. Ezzouine</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Nakheli"> A. Nakheli</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents a high position electromagnetic sensor system (HPESS) that is applicable for moving object detection. The authors have developed a high-performance position sensor prototype dedicated to students’ laboratory. The challenge was to obtain a highly accurate and real-time sensor that is able to calculate position, length or displacement. An electromagnetic solution based on a two coil induction principal was adopted. The HPESS converts mechanical motion to electric energy with direct contact. The output signal can then be fed to an electronic circuit. The voltage output change from the sensor is captured by data acquisition system using LabVIEW software. The displacement of the moving object is determined. The measured data are transmitted to a PC in real-time via a DAQ (NI USB -6281). This paper also describes the data acquisition analysis and the conditioning card developed specially for sensor signal monitoring. The data is then recorded and viewed using a user interface written using National Instrument LabVIEW software. On-line displays of time and voltage of the sensor signal provide a user-friendly data acquisition interface. The sensor provides an uncomplicated, accurate, reliable, inexpensive transducer for highly sophisticated control systems. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20sensor" title="electromagnetic sensor">electromagnetic sensor</a>, <a href="https://publications.waset.org/abstracts/search?q=accurately" title=" accurately"> accurately</a>, <a href="https://publications.waset.org/abstracts/search?q=data%20acquisition" title=" data acquisition"> data acquisition</a>, <a href="https://publications.waset.org/abstracts/search?q=position%20measurement" title=" position measurement"> position measurement</a> </p> <a href="https://publications.waset.org/abstracts/66493/accurate-position-electromagnetic-sensor-using-data-acquisition-system" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/66493.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">285</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3423</span> Estimation of Relative Subsidence of Collapsible Soils Using Electromagnetic Measurements</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Henok%20Hailemariam">Henok Hailemariam</a>, <a href="https://publications.waset.org/abstracts/search?q=Frank%20Wuttke"> Frank Wuttke</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Collapsible soils are weak soils that appear to be stable in their natural state, normally dry condition, but rapidly deform under saturation (wetting), thus generating large and unexpected settlements which often yield disastrous consequences for structures unwittingly built on such deposits. In this study, a prediction model for the relative subsidence of stressed collapsible soils based on dielectric permittivity measurement is presented. Unlike most existing methods for soil subsidence prediction, this model does not require moisture content as an input parameter, thus providing the opportunity to obtain accurate estimation of the relative subsidence of collapsible soils using dielectric measurement only. The prediction model is developed based on an existing relative subsidence prediction model (which is dependent on soil moisture condition) and an advanced theoretical frequency and temperature-dependent electromagnetic mixing equation (which effectively removes the moisture content dependence of the original relative subsidence prediction model). For large scale sub-surface soil exploration purposes, the spatial sub-surface soil dielectric data over wide areas and high depths of weak (collapsible) soil deposits can be obtained using non-destructive high frequency electromagnetic (HF-EM) measurement techniques such as ground penetrating radar (GPR). For laboratory or small scale in-situ measurements, techniques such as an open-ended coaxial line with widely applicable time domain reflectometry (TDR) or vector network analysers (VNAs) are usually employed to obtain the soil dielectric data. By using soil dielectric data obtained from small or large scale non-destructive HF-EM investigations, the new model can effectively predict the relative subsidence of weak soils without the need to extract samples for moisture content measurement. Some of the resulting benefits are the preservation of the undisturbed nature of the soil as well as a reduction in the investigation costs and analysis time in the identification of weak (problematic) soils. The accuracy of prediction of the presented model is assessed by conducting relative subsidence tests on a collapsible soil at various initial soil conditions and a good match between the model prediction and experimental results is obtained. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=collapsible%20soil" title="collapsible soil">collapsible soil</a>, <a href="https://publications.waset.org/abstracts/search?q=dielectric%20permittivity" title=" dielectric permittivity"> dielectric permittivity</a>, <a href="https://publications.waset.org/abstracts/search?q=moisture%20content" title=" moisture content"> moisture content</a>, <a href="https://publications.waset.org/abstracts/search?q=relative%20subsidence" title=" relative subsidence"> relative subsidence</a> </p> <a href="https://publications.waset.org/abstracts/65451/estimation-of-relative-subsidence-of-collapsible-soils-using-electromagnetic-measurements" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/65451.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">363</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3422</span> Design of Process Parameters in Electromagnetic Forming Apparatus by FEM</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Hyeong-Gyu%20Park">Hyeong-Gyu Park</a>, <a href="https://publications.waset.org/abstracts/search?q=Hak-Gon%20Noh"> Hak-Gon Noh</a>, <a href="https://publications.waset.org/abstracts/search?q=Beom-Soo%20Kang"> Beom-Soo Kang</a>, <a href="https://publications.waset.org/abstracts/search?q=Jeong%20Kim"> Jeong Kim</a> </p> <p class="card-text"><strong>Abstract:</strong></p> Electromagnetic forming (EMF) process is one of a high-speed forming process, which uses an electromagnetic body (Lorentz) force to deform work-piece. Advantages of EMF are summarized as improvement of formability, reduction in wrinkling, non-contact forming. In this study, the spiral coil is considered to evaluate formability in terms of pressure distribution of the forming process. It also is represented forming results of numerical analysis using ANSYS code. In the numerical simulation, RLC circuit coupled with spiral coil was made to consider the design parameters such as system input current and electromagnetic force. The simulation results show that even though input peak currents level are same level in each case, forming condition is certainly different because of frequency of input current and magnitude of current density and magnetic flux density. Finally, the simulation results appear that electromagnetic forming force apparently affected by input current frequency which determines magnitude of current density and magnetic flux density. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20forming" title="electromagnetic forming">electromagnetic forming</a>, <a href="https://publications.waset.org/abstracts/search?q=high-speed%20forming" title=" high-speed forming"> high-speed forming</a>, <a href="https://publications.waset.org/abstracts/search?q=RLC%20circuit" title=" RLC circuit"> RLC circuit</a>, <a href="https://publications.waset.org/abstracts/search?q=Lorentz%20force" title=" Lorentz force"> Lorentz force</a> </p> <a href="https://publications.waset.org/abstracts/7042/design-of-process-parameters-in-electromagnetic-forming-apparatus-by-fem" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/7042.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">455</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3421</span> A Proposed Algorithm for Obtaining the Map of Subscribers’ Density Distribution for a Mobile Wireless Communication Network</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=C.%20Temaneh-Nyah">C. Temaneh-Nyah</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20A.%20Phiri"> F. A. Phiri</a>, <a href="https://publications.waset.org/abstracts/search?q=D.%20Karegeya"> D. Karegeya</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This paper presents an algorithm for obtaining the map of subscriber’s density distribution for a mobile wireless communication network based on the actual subscriber's traffic data obtained from the base station. This is useful in statistical characterization of the mobile wireless network. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility" title="electromagnetic compatibility">electromagnetic compatibility</a>, <a href="https://publications.waset.org/abstracts/search?q=statistical%20analysis" title=" statistical analysis"> statistical analysis</a>, <a href="https://publications.waset.org/abstracts/search?q=simulation%20of%20communication%20network" title=" simulation of communication network"> simulation of communication network</a>, <a href="https://publications.waset.org/abstracts/search?q=subscriber%20density" title=" subscriber density"> subscriber density</a> </p> <a href="https://publications.waset.org/abstracts/2453/a-proposed-algorithm-for-obtaining-the-map-of-subscribers-density-distribution-for-a-mobile-wireless-communication-network" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/2453.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">309</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3420</span> Application of MoM-GEC Method for Electromagnetic Study of Planar Microwave Structures: Shielding Application</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Ahmed%20Nouainia">Ahmed Nouainia</a>, <a href="https://publications.waset.org/abstracts/search?q=Mohamed%20Hajji"> Mohamed Hajji</a>, <a href="https://publications.waset.org/abstracts/search?q=Taoufik%20Aguili"> Taoufik Aguili</a> </p> <p class="card-text"><strong>Abstract:</strong></p> In this paper, an electromagnetic analysis is presented for describing the influence of shielding in a rectangular waveguide. A hybridization based on the method of moments combined to the generalized equivalent circuit MoM-GEC is used to model the problem. This is validated by applying the MoM-GEC hybridization to investigate a diffraction structure. It consists of electromagnetic diffraction by an iris in a rectangular waveguide. Numerical results are shown and discussed and a comparison with FEM and Marcuvitz methods is achieved. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=method%20MoM-GEC" title="method MoM-GEC">method MoM-GEC</a>, <a href="https://publications.waset.org/abstracts/search?q=waveguide" title=" waveguide"> waveguide</a>, <a href="https://publications.waset.org/abstracts/search?q=shielding" title=" shielding"> shielding</a>, <a href="https://publications.waset.org/abstracts/search?q=equivalent%20circuit" title=" equivalent circuit"> equivalent circuit</a> </p> <a href="https://publications.waset.org/abstracts/62267/application-of-mom-gec-method-for-electromagnetic-study-of-planar-microwave-structures-shielding-application" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/62267.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">374</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3419</span> Continuous Dyeing of Graphene and Polyaniline on Textiles for Electromagnetic Interference Shielding: An Application of Intelligent Fabrics</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Mourad%20%20Makhlouf">Mourad Makhlouf</a>, <a href="https://publications.waset.org/abstracts/search?q=Meriem%20Boutamine"> Meriem Boutamine</a>, <a href="https://publications.waset.org/abstracts/search?q=Hachemi%20Hichem"> Hachemi Hichem</a>, <a href="https://publications.waset.org/abstracts/search?q=Zoubir%20Benmaamar"> Zoubir Benmaamar</a>, <a href="https://publications.waset.org/abstracts/search?q=Didier%20Villemin"> Didier Villemin</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study explores the use of intelligent textiles for electromagnetic shielding through the continuous dyeing of graphene and polyaniline onto cotton fabric. Graphene was obtained by recycling graphite from spent batteries, and polyaniline was obtained in situ using H2O2. Graphene and polyaniline were bottom-modified on the fiber surface to improve adhesion and achieve a uniform distribution. This study evaluated the effect of the specific gravity percentage on sheet performance and active shielding against electromagnetic interference (EMI). Results showed that the dyed fabrics of graphene, polyaniline, and graphene/polyaniline demonstrated higher conductivity and EMI SE values of 9 to 16 dB in the 8 to 9 GHz range of the X-band, with potential applications in electromagnetic shielding. The use of intelligent textiles offers a sustainable and effective approach to achieving EMI shielding, with the added benefits of recycling waste materials and improving the properties of cotton fabrics. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=%27ntelligent%20textiles" title="'ntelligent textiles">'ntelligent textiles</a>, <a href="https://publications.waset.org/abstracts/search?q=graphene" title=" graphene"> graphene</a>, <a href="https://publications.waset.org/abstracts/search?q=polyaniline" title=" polyaniline"> polyaniline</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20shielding" title=" electromagnetic shielding"> electromagnetic shielding</a>, <a href="https://publications.waset.org/abstracts/search?q=conductivity" title=" conductivity"> conductivity</a>, <a href="https://publications.waset.org/abstracts/search?q=recycling." title=" recycling."> recycling.</a> </p> <a href="https://publications.waset.org/abstracts/190791/continuous-dyeing-of-graphene-and-polyaniline-on-textiles-for-electromagnetic-interference-shielding-an-application-of-intelligent-fabrics" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/190791.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">39</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3418</span> Improvement of the Calciferous Minerals Floatability through the Application of High-Power Electromagnetic Pulses</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Valentine%20A.%20Chanturiya">Valentine A. Chanturiya</a>, <a href="https://publications.waset.org/abstracts/search?q=Igor%20Zh.%20Bunin"> Igor Zh. Bunin</a>, <a href="https://publications.waset.org/abstracts/search?q=Maria%20V.%20Ryazantseva"> Maria V. Ryazantseva</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The modification of structural and chemical properties of fluorite, scheelite and calcite under the impact of high-power electromagnetic pulses (HPEMP-treatment) were studied with the help of adsorption of acid-base indicators and atomic – force microscopy (AFM). The HPEMP-treatment during the space of 30 seconds resulted in the intensification of fluorite surface the electron-donating ability and acceptor properties of calcite and scheelite surfaces. High-power electromagnetic treatment of the single minerals resulted in the improvement of the calciferous minerals floatability. The rising of the scheelite recovery is 10 – 12%, fluorite – 5 – 6%, calcite – 7 – 8%. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=calcite" title="calcite">calcite</a>, <a href="https://publications.waset.org/abstracts/search?q=fluorite" title=" fluorite"> fluorite</a>, <a href="https://publications.waset.org/abstracts/search?q=scheelite" title=" scheelite"> scheelite</a>, <a href="https://publications.waset.org/abstracts/search?q=high%20power%20electromagnetic%20pulses" title=" high power electromagnetic pulses"> high power electromagnetic pulses</a>, <a href="https://publications.waset.org/abstracts/search?q=floatability" title=" floatability"> floatability</a> </p> <a href="https://publications.waset.org/abstracts/64752/improvement-of-the-calciferous-minerals-floatability-through-the-application-of-high-power-electromagnetic-pulses" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/64752.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">288</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3417</span> Electromagnetic Tuned Mass Damper Approach for Regenerative Suspension</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=S.%20Kopylov">S. Kopylov</a>, <a href="https://publications.waset.org/abstracts/search?q=C.%20Z.%20Bo"> C. Z. Bo</a> </p> <p class="card-text"><strong>Abstract:</strong></p> This study is aimed at exploring the possibility of energy recovery through the suppression of vibrations. The article describes design of electromagnetic dynamic damper. The magnetic part of the device performs the function of a tuned mass damper, thereby providing both energy regeneration and damping properties to the protected mass. According to the theory of tuned mass damper, equations of mathematical models were obtained. Then, under given properties of current system, amplitude frequency response was investigated. Therefore, main ideas and methods for further research were defined. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20damper" title="electromagnetic damper">electromagnetic damper</a>, <a href="https://publications.waset.org/abstracts/search?q=oscillations%20with%20two%20degrees%20of%20freedom" title=" oscillations with two degrees of freedom"> oscillations with two degrees of freedom</a>, <a href="https://publications.waset.org/abstracts/search?q=regeneration%20systems" title=" regeneration systems"> regeneration systems</a>, <a href="https://publications.waset.org/abstracts/search?q=tuned%20mass%20damper" title=" tuned mass damper"> tuned mass damper</a> </p> <a href="https://publications.waset.org/abstracts/81403/electromagnetic-tuned-mass-damper-approach-for-regenerative-suspension" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/81403.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">208</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3416</span> Absorption of Ultrashort Electromagnetic Pulses on Gold Nanospheres in Various Dielectric Media</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Sergey%20Svita">Sergey Svita</a>, <a href="https://publications.waset.org/abstracts/search?q=Valeriy%20Astapenko"> Valeriy Astapenko</a> </p> <p class="card-text"><strong>Abstract:</strong></p> The study is devoted to theoretical analysis of ultrashort electromagnetic pulses (USP) absorption on gold nanospheres. Dependencies of USP energy absorption on nanospheres placed in various matrix are compared. The results of calculation of absorbed energy on gold nanospheres as a function of ultrashort electromagnetic pulse carrier frequency and number of pulse cycles of carrier frequency show strong non-linear dependence of absorbed energy on number of cycles of carrier frequency, but for relatively large number of cycles on USP carrier frequency it goes to linear dependence. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=ultrashort%20electromagnetic%20pulses" title="ultrashort electromagnetic pulses">ultrashort electromagnetic pulses</a>, <a href="https://publications.waset.org/abstracts/search?q=absorption" title=" absorption"> absorption</a>, <a href="https://publications.waset.org/abstracts/search?q=nanospheres" title=" nanospheres"> nanospheres</a>, <a href="https://publications.waset.org/abstracts/search?q=theoretical%20research" title=" theoretical research"> theoretical research</a> </p> <a href="https://publications.waset.org/abstracts/53141/absorption-of-ultrashort-electromagnetic-pulses-on-gold-nanospheres-in-various-dielectric-media" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/53141.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">256</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3415</span> Induction Heating and Electromagnetic Stirring of Bi-Phasic Metal/Glass Molten Bath for Mixed Nuclear Waste Treatment</h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=P.%20Charvin">P. Charvin</a>, <a href="https://publications.waset.org/abstracts/search?q=R.%20Bourrou"> R. Bourrou</a>, <a href="https://publications.waset.org/abstracts/search?q=F.%20Lemont"> F. Lemont</a>, <a href="https://publications.waset.org/abstracts/search?q=C.%20Lafon"> C. Lafon</a>, <a href="https://publications.waset.org/abstracts/search?q=A.%20Russello"> A. Russello</a> </p> <p class="card-text"><strong>Abstract:</strong></p> For nuclear waste treatment and confinement, a specific IN-CAN melting module based on low-frequency induction heating have been designed. The frequency of 50Hz has been chosen to improve penetration length through metal. In this design, the liquid metal, strongly stirred by electromagnetic effects, presents shape of a dome caused by strong Laplace forces developing in the bulk of bath. Because of a lower density, the glass phase is located above the metal phase and is heated and stirred by metal through interface. Electric parameters (Intensity, frequency) give precious information about metal load and composition (resistivity of alloy) through impedance modification. Then, power supply can be adapted to energy transfer efficiency for suitable process supervision. Modeling of this system allows prediction of metal dome shape (in agreement with experimental measurement with a specific device), glass and metal velocity, heat and motion transfer through interface. MHD modeling is achieved with COMSOL and Fluent. First, a simplified model is used to obtain the shape of the metal dome. Then the shape is fixed to calculate the fluid flow and the thermal part. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20stirring" title="electromagnetic stirring">electromagnetic stirring</a>, <a href="https://publications.waset.org/abstracts/search?q=induction%20heating" title=" induction heating"> induction heating</a>, <a href="https://publications.waset.org/abstracts/search?q=interface%20modeling" title=" interface modeling"> interface modeling</a>, <a href="https://publications.waset.org/abstracts/search?q=metal%20load" title=" metal load"> metal load</a> </p> <a href="https://publications.waset.org/abstracts/83643/induction-heating-and-electromagnetic-stirring-of-bi-phasic-metalglass-molten-bath-for-mixed-nuclear-waste-treatment" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/83643.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">267</span> </span> </div> </div> <div class="card paper-listing mb-3 mt-3"> <h5 class="card-header" style="font-size:.9rem"><span class="badge badge-info">3414</span> A Review of Protocols and Guidelines Addressing the Exposure of Occupants to Electromagnetic Field (EMF) Radiation in Buildings </h5> <div class="card-body"> <p class="card-text"><strong>Authors:</strong> <a href="https://publications.waset.org/abstracts/search?q=Shabnam%20Monadizadeh">Shabnam Monadizadeh</a>, <a href="https://publications.waset.org/abstracts/search?q=Charles%20Kibert"> Charles Kibert</a>, <a href="https://publications.waset.org/abstracts/search?q=Jiaxuan%20Li"> Jiaxuan Li</a>, <a href="https://publications.waset.org/abstracts/search?q=Janghoon%20Woo"> Janghoon Woo</a>, <a href="https://publications.waset.org/abstracts/search?q=Ashish%20Asutosh"> Ashish Asutosh</a>, <a href="https://publications.waset.org/abstracts/search?q=Samira%20Roostaei"> Samira Roostaei</a>, <a href="https://publications.waset.org/abstracts/search?q=Maryam%20Kouhirostami"> Maryam Kouhirostami</a> </p> <p class="card-text"><strong>Abstract:</strong></p> A significant share of the technology that has emerged over the past several decades produces electromagnetic field (EMF) radiation. Communications devices, household appliances, industrial equipment, and medical devices all produce EMF radiation with a variety of frequencies, strengths, and ranges. Some EMF radiation, such as Extremely Low Frequency (ELF), Radio Frequency (RF), and the ionizing range have been shown to have harmful effects on human health. Depending on the frequency and strength of the radiation, EMF radiation can have health effects at the cellular level as well as at brain, nervous, and cardiovascular levels. Health authorities have enacted regulations locally and globally to set critical values to limit the adverse effects of EMF radiation. By introducing a more comprehensive field of EMF radiation study and practice, architects and designers can design for a safer electromagnetic (EM) indoor environment, and, as building and construction specialists, will be able to monitor and reduce EM radiation. This paper identifies the nature of EMF radiation in the built environment, the various EMF radiation sources, and its human health effects. It addresses European and US regulations for EMF radiation in buildings and provides a preliminary action plan. The challenges of developing measurement protocols for the various EMF radiation frequency ranges and determining the effects of EMF radiation on building occupants are discussed. This paper argues that a mature method for measuring EMF radiation in building environments and linking these measurements to human health impacts occupant health should be developed to provide adequate safeguards for human occupants of buildings for future research. <p class="card-text"><strong>Keywords:</strong> <a href="https://publications.waset.org/abstracts/search?q=biological%20affection" title="biological affection">biological affection</a>, <a href="https://publications.waset.org/abstracts/search?q=electromagnetic%20field" title=" electromagnetic field"> electromagnetic field</a>, <a href="https://publications.waset.org/abstracts/search?q=building%20regulation" title=" building regulation"> building regulation</a>, <a href="https://publications.waset.org/abstracts/search?q=human%20health" title=" human health"> human health</a>, <a href="https://publications.waset.org/abstracts/search?q=healthy%20building" title=" healthy building"> healthy building</a>, <a href="https://publications.waset.org/abstracts/search?q=clean%20construction" title=" clean construction "> clean construction </a> </p> <a href="https://publications.waset.org/abstracts/129637/a-review-of-protocols-and-guidelines-addressing-the-exposure-of-occupants-to-electromagnetic-field-emf-radiation-in-buildings" class="btn btn-primary btn-sm">Procedia</a> <a href="https://publications.waset.org/abstracts/129637.pdf" target="_blank" class="btn btn-primary btn-sm">PDF</a> <span class="bg-info text-light px-1 py-1 float-right rounded"> Downloads <span class="badge badge-light">181</span> </span> </div> </div> <ul class="pagination"> <li class="page-item disabled"><span class="page-link">‹</span></li> <li class="page-item active"><span class="page-link">1</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=2">2</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=3">3</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=4">4</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=5">5</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=6">6</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=7">7</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=8">8</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=9">9</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=10">10</a></li> <li class="page-item disabled"><span class="page-link">...</span></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=114">114</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=115">115</a></li> <li class="page-item"><a class="page-link" href="https://publications.waset.org/abstracts/search?q=electromagnetic%20compatibility%20measurement&page=2" rel="next">›</a></li> </ul> </div> </main> <footer> <div id="infolinks" class="pt-3 pb-2"> <div class="container"> <div style="background-color:#f5f5f5;" class="p-3"> <div class="row"> <div class="col-md-2"> <ul class="list-unstyled"> About <li><a href="https://waset.org/page/support">About Us</a></li> <li><a href="https://waset.org/page/support#legal-information">Legal</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/WASET-16th-foundational-anniversary.pdf">WASET celebrates its 16th foundational anniversary</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Account <li><a href="https://waset.org/profile">My Account</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Explore <li><a href="https://waset.org/disciplines">Disciplines</a></li> <li><a href="https://waset.org/conferences">Conferences</a></li> <li><a href="https://waset.org/conference-programs">Conference Program</a></li> <li><a href="https://waset.org/committees">Committees</a></li> <li><a href="https://publications.waset.org">Publications</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Research <li><a href="https://publications.waset.org/abstracts">Abstracts</a></li> <li><a href="https://publications.waset.org">Periodicals</a></li> <li><a href="https://publications.waset.org/archive">Archive</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Open Science <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Philosophy.pdf">Open Science Philosophy</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Science-Award.pdf">Open Science Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Open-Society-Open-Science-and-Open-Innovation.pdf">Open Innovation</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Postdoctoral-Fellowship-Award.pdf">Postdoctoral Fellowship Award</a></li> <li><a target="_blank" rel="nofollow" href="https://publications.waset.org/static/files/Scholarly-Research-Review.pdf">Scholarly Research Review</a></li> </ul> </div> <div class="col-md-2"> <ul class="list-unstyled"> Support <li><a href="https://waset.org/page/support">Support</a></li> <li><a href="https://waset.org/profile/messages/create">Contact Us</a></li> <li><a href="https://waset.org/profile/messages/create">Report Abuse</a></li> </ul> </div> </div> </div> </div> </div> <div class="container text-center"> <hr style="margin-top:0;margin-bottom:.3rem;"> <a href="https://creativecommons.org/licenses/by/4.0/" target="_blank" class="text-muted small">Creative Commons Attribution 4.0 International License</a> <div id="copy" class="mt-2">© 2024 World Academy of Science, Engineering and Technology</div> </div> </footer> <a href="javascript:" id="return-to-top"><i class="fas fa-arrow-up"></i></a> <div class="modal" id="modal-template"> <div class="modal-dialog"> <div class="modal-content"> <div class="row m-0 mt-1"> <div class="col-md-12"> <button type="button" class="close" data-dismiss="modal" aria-label="Close"><span aria-hidden="true">×</span></button> </div> </div> <div class="modal-body"></div> </div> </div> </div> <script src="https://cdn.waset.org/static/plugins/jquery-3.3.1.min.js"></script> <script src="https://cdn.waset.org/static/plugins/bootstrap-4.2.1/js/bootstrap.bundle.min.js"></script> <script src="https://cdn.waset.org/static/js/site.js?v=150220211556"></script> <script> jQuery(document).ready(function() { /*jQuery.get("https://publications.waset.org/xhr/user-menu", function (response) { jQuery('#mainNavMenu').append(response); });*/ jQuery.get({ url: "https://publications.waset.org/xhr/user-menu", cache: false }).then(function(response){ jQuery('#mainNavMenu').append(response); }); }); </script> </body> </html>